id	author	title	date	pages	extension	mime	words	sentence	flesch	summary	cache	txt
ajst-20179	Luo, Xiong; Mo, Li; Xiao, Shenbin	Effect of Different Outlet Structure of Axial Flow Cyclone Separator in Drying Tower	2024	5	.pdf	application/pdf	3393	165	53	Effect of dust outlet diameter on separation efficiency Through the analysis of models 1, 2 and 3, it is found that when the diameter of the dust outlet increases from 800mm (which is equivalent to the diameter of the cylinder) to 880mm and 960mm, the air volume of the dust outlet is 0.509kg/s, 0.538kg/s and 0.544kg/s, respectively. Geometric model and parameters In order to reduce the complexity of the study and improve the accuracy of the simulation, this paper conducted 1:1 solid modeling of the guide vane, diameter reduction, cylinder, air outlet and dust outlet of the axial flow cyclone with three types of dust outlet.	cache/ajst-20179.pdf	txt/ajst-20179.txt