id	author	title	date	pages	extension	mime	words	sentence	flesch	summary	cache	txt
ap-602	Brož, J.; Fořt, I.; Sperling, R.; Jambere, S.; Heiser, M.; Rieger, F.	Pumping Capacity of Pitched Blade Impellers in a Tall Vessel with a Draught Tube	2004	6	.pdf	application/pdf	3988	156	63	The PBT pumping capacity will be calculated from the radial profile of the axial compo- 48 © Czech Technical University Publishing House http://ctn.cvut.cz/ap/ Acta Polytechnica Vol. 44 No. 4/2004 Pumping Capacity of Pitched Blade Impellers in a Tall Vessel with a Draught Tube J. Brož, I. Fořt, R. Sperling, S. Jambere, M. Heiser, F. Rieger A study was made of the pumping capacity of pitched blade impellers (two, three, four, five and six blade pitched blade impellers with pitch angles � � 35° and 45°) coaxially located in a cylindrical pilot plant vessel with cylindrical draught tube provided with a standard dished bottom. For all the tested pitched blade impellers the impeller power number when � � 45° exceeds the value of this quantity when pitch angle � � 35°, while the flow rate number when � � 35° exceeds this quantity when � � 45°.	cache/ap-602.pdf	txt/ap-602.txt