id	sid	tid	token	lemma	pos
ap-2293	1	1	acta	acta	PROPN
ap-2293	1	2	polytechnica	polytechnica	PROPN
ap-2293	1	3	doi:10.14311	doi:10.14311	PROPN
ap-2293	1	4	/	/	SYM
ap-2293	1	5	ap.2015.55.0140	ap.2015.55.0140	PROPN
ap-2293	1	6	acta	acta	PROPN
ap-2293	1	7	polytechnica	polytechnica	PROPN
ap-2293	1	8	55(3):140–145	55(3):140–145	PROPN
ap-2293	1	9	,	,	PUNCT
ap-2293	1	10	2015	2015	NUM
ap-2293	1	11	©	©	PROPN
ap-2293	1	12	czech	czech	PROPN
ap-2293	1	13	technical	technical	PROPN
ap-2293	1	14	university	university	PROPN
ap-2293	1	15	in	in	ADP
ap-2293	1	16	prague	prague	PROPN
ap-2293	1	17	,	,	PUNCT
ap-2293	1	18	2015	2015	NUM
ap-2293	1	19	available	available	ADJ
ap-2293	1	20	online	online	ADV
ap-2293	1	21	at	at	ADP
ap-2293	1	22	http://ojs.cvut.cz/ojs/index.php/ap	http://ojs.cvut.cz/ojs/index.php/ap	PROPN
ap-2293	1	23	simulation	simulation	NOUN
ap-2293	1	24	of	of	ADP
ap-2293	1	25	heat	heat	NOUN
ap-2293	1	26	transport	transport	NOUN
ap-2293	1	27	during	during	ADP
ap-2293	1	28	the	the	DET
ap-2293	1	29	process	process	NOUN
ap-2293	1	30	of	of	ADP
ap-2293	1	31	cooling	cool	VERB
ap-2293	1	32	a	a	DET
ap-2293	1	33	sugar	sugar	NOUN
ap-2293	1	34	solution	solution	NOUN
ap-2293	1	35	in	in	ADP
ap-2293	1	36	a	a	DET
ap-2293	1	37	recuperation	recuperation	NOUN
ap-2293	1	38	exchanger	exchanger	NOUN
ap-2293	1	39	tomáš	tomáš	NOUN
ap-2293	1	40	brestoviča	brestoviča	PROPN
ap-2293	1	41	,	,	PUNCT
ap-2293	1	42	mária	mária	PROPN
ap-2293	1	43	čarnogurskáa,∗	čarnogurskáa,∗	PROPN
ap-2293	1	44	,	,	PUNCT
ap-2293	1	45	miroslav	miroslav	ADJ
ap-2293	1	46	příhodab	příhodab	PROPN
ap-2293	1	47	,	,	PUNCT
ap-2293	1	48	michal	michal	PROPN
ap-2293	1	49	kubíka	kubíka	VERB
ap-2293	1	50	a	a	DET
ap-2293	1	51	faculty	faculty	NOUN
ap-2293	1	52	of	of	ADP
ap-2293	1	53	mechanical	mechanical	ADJ
ap-2293	1	54	engineering	engineering	NOUN
ap-2293	1	55	,	,	PUNCT
ap-2293	1	56	technical	technical	ADJ
ap-2293	1	57	university	university	PROPN
ap-2293	1	58	of	of	ADP
ap-2293	1	59	košice	košice	PROPN
ap-2293	1	60	,	,	PUNCT
ap-2293	1	61	department	department	NOUN
ap-2293	1	62	of	of	ADP
ap-2293	1	63	power	power	NOUN
ap-2293	1	64	engineering	engineering	NOUN
ap-2293	1	65	,	,	PUNCT
ap-2293	1	66	vysokoškolská	vysokoškolská	NOUN
ap-2293	1	67	4	4	NUM
ap-2293	1	68	,	,	PUNCT
ap-2293	1	69	042	042	NUM
ap-2293	1	70	00	00	NUM
ap-2293	1	71	košice	košice	NOUN
ap-2293	1	72	,	,	PUNCT
ap-2293	1	73	slovak	slovak	ADJ
ap-2293	1	74	republic	republic	NOUN
ap-2293	1	75	b	b	PROPN
ap-2293	1	76	faculty	faculty	NOUN
ap-2293	1	77	of	of	ADP
ap-2293	1	78	metallurgy	metallurgy	NOUN
ap-2293	1	79	and	and	CCONJ
ap-2293	1	80	materials	material	NOUN
ap-2293	1	81	engineering	engineering	NOUN
ap-2293	1	82	,	,	PUNCT
ap-2293	1	83	všb	všb	ADJ
ap-2293	1	84	–	–	PUNCT
ap-2293	1	85	technical	technical	ADJ
ap-2293	1	86	university	university	PROPN
ap-2293	1	87	of	of	ADP
ap-2293	1	88	ostrava	ostrava	PROPN
ap-2293	1	89	,	,	PUNCT
ap-2293	1	90	department	department	PROPN
ap-2293	1	91	of	of	ADP
ap-2293	1	92	thermal	thermal	ADJ
ap-2293	1	93	engineering	engineering	NOUN
ap-2293	1	94	,	,	PUNCT
ap-2293	1	95	17	17	NUM
ap-2293	1	96	.	.	PUNCT
ap-2293	2	1	listopadu	listopadu	ADJ
ap-2293	2	2	15	15	NUM
ap-2293	2	3	,	,	PUNCT
ap-2293	2	4	708	708	NUM
ap-2293	2	5	33	33	NUM
ap-2293	2	6	ostrava	ostrava	PROPN
ap-2293	2	7	-	-	PUNCT
ap-2293	2	8	poruba	poruba	PROPN
ap-2293	2	9	,	,	PUNCT
ap-2293	2	10	czech	czech	PROPN
ap-2293	2	11	republic	republic	NOUN
ap-2293	2	12	∗	∗	NOUN
ap-2293	2	13	corresponding	correspond	VERB
ap-2293	2	14	author	author	NOUN
ap-2293	2	15	:	:	PUNCT
ap-2293	2	16	maria.carnogurska@tuke.sk	maria.carnogurska@tuke.sk	NOUN
ap-2293	2	17	abstract	abstract	NOUN
ap-2293	2	18	.	.	PUNCT
ap-2293	3	1	the	the	DET
ap-2293	3	2	paper	paper	NOUN
ap-2293	3	3	describes	describe	VERB
ap-2293	3	4	a	a	DET
ap-2293	3	5	mathematical	mathematical	ADJ
ap-2293	3	6	model	model	NOUN
ap-2293	3	7	of	of	ADP
ap-2293	3	8	the	the	DET
ap-2293	3	9	cooling	cool	VERB
ap-2293	3	10	process	process	NOUN
ap-2293	3	11	of	of	ADP
ap-2293	3	12	a	a	DET
ap-2293	3	13	highly	highly	ADV
ap-2293	3	14	concentrated	concentrated	ADJ
ap-2293	3	15	sugar	sugar	NOUN
ap-2293	3	16	solution	solution	NOUN
ap-2293	3	17	in	in	ADP
ap-2293	3	18	an	an	DET
ap-2293	3	19	exchanger	exchanger	NOUN
ap-2293	3	20	with	with	ADP
ap-2293	3	21	a	a	DET
ap-2293	3	22	specifically	specifically	ADV
ap-2293	3	23	shaped	shape	VERB
ap-2293	3	24	heat	heat	NOUN
ap-2293	3	25	exchanging	exchange	VERB
ap-2293	3	26	surface	surface	NOUN
ap-2293	3	27	of	of	ADP
ap-2293	3	28	the	the	DET
ap-2293	3	29	cooling	cool	VERB
ap-2293	3	30	panels	panel	NOUN
ap-2293	3	31	.	.	PUNCT
ap-2293	4	1	an	an	DET
ap-2293	4	2	analysis	analysis	NOUN
ap-2293	4	3	of	of	ADP
ap-2293	4	4	the	the	DET
ap-2293	4	5	individual	individual	ADJ
ap-2293	4	6	parts	part	NOUN
ap-2293	4	7	of	of	ADP
ap-2293	4	8	the	the	DET
ap-2293	4	9	stum	stum	NOUN
ap-2293	4	10	cooling	cool	VERB
ap-2293	4	11	line	line	NOUN
ap-2293	4	12	is	be	AUX
ap-2293	4	13	made	make	VERB
ap-2293	4	14	,	,	PUNCT
ap-2293	4	15	dealing	deal	VERB
ap-2293	4	16	with	with	ADP
ap-2293	4	17	the	the	DET
ap-2293	4	18	cooling	cool	VERB
ap-2293	4	19	performance	performance	NOUN
ap-2293	4	20	of	of	ADP
ap-2293	4	21	the	the	DET
ap-2293	4	22	cooling	cool	VERB
ap-2293	4	23	panels	panel	NOUN
ap-2293	4	24	located	locate	VERB
ap-2293	4	25	in	in	ADP
ap-2293	4	26	the	the	DET
ap-2293	4	27	stum	stum	NOUN
ap-2293	4	28	tanks	tank	NOUN
ap-2293	4	29	,	,	PUNCT
ap-2293	4	30	whose	whose	DET
ap-2293	4	31	volume	volume	NOUN
ap-2293	4	32	is	be	AUX
ap-2293	4	33	3230	3230	NUM
ap-2293	4	34	litres	litre	NOUN
ap-2293	4	35	or	or	CCONJ
ap-2293	4	36	1430	1430	NUM
ap-2293	4	37	litres	litre	NOUN
ap-2293	4	38	.	.	PUNCT
ap-2293	5	1	one	one	NUM
ap-2293	5	2	of	of	ADP
ap-2293	5	3	the	the	DET
ap-2293	5	4	monitored	monitored	ADJ
ap-2293	5	5	parameters	parameter	NOUN
ap-2293	5	6	is	be	AUX
ap-2293	5	7	the	the	DET
ap-2293	5	8	cooling	cool	VERB
ap-2293	5	9	performance	performance	NOUN
ap-2293	5	10	of	of	ADP
ap-2293	5	11	the	the	DET
ap-2293	5	12	jn30	jn30	PROPN
ap-2293	5	13	aggregate	aggregate	NOUN
ap-2293	5	14	.	.	PUNCT
ap-2293	6	1	the	the	DET
ap-2293	6	2	article	article	NOUN
ap-2293	6	3	also	also	ADV
ap-2293	6	4	deals	deal	VERB
ap-2293	6	5	with	with	ADP
ap-2293	6	6	the	the	DET
ap-2293	6	7	appropriateness	appropriateness	NOUN
ap-2293	6	8	of	of	ADP
ap-2293	6	9	the	the	DET
ap-2293	6	10	aggregate	aggregate	NOUN
ap-2293	6	11	for	for	ADP
ap-2293	6	12	cooling	cool	VERB
ap-2293	6	13	the	the	DET
ap-2293	6	14	stum	stum	NOUN
ap-2293	6	15	with	with	ADP
ap-2293	6	16	a	a	DET
ap-2293	6	17	total	total	ADJ
ap-2293	6	18	volume	volume	NOUN
ap-2293	6	19	78.21m3	78.21m3	NUM
ap-2293	6	20	,	,	PUNCT
ap-2293	6	21	from	from	ADP
ap-2293	6	22	the	the	DET
ap-2293	6	23	real	real	ADJ
ap-2293	6	24	operation	operation	NOUN
ap-2293	6	25	temperature	temperature	NOUN
ap-2293	6	26	to	to	ADP
ap-2293	6	27	0	0	NUM
ap-2293	6	28	°	°	ADP
ap-2293	6	29	c	c	NOUN
ap-2293	6	30	during	during	ADP
ap-2293	6	31	48	48	NUM
ap-2293	6	32	hours	hour	NOUN
ap-2293	6	33	.	.	PUNCT
ap-2293	7	1	keywords	keyword	NOUN
ap-2293	7	2	:	:	PUNCT
ap-2293	7	3	concentrated	concentrated	ADJ
ap-2293	7	4	solution	solution	NOUN
ap-2293	7	5	;	;	PUNCT
ap-2293	7	6	cooling	cool	VERB
ap-2293	7	7	;	;	PUNCT
ap-2293	7	8	numeric	numeric	PROPN
ap-2293	7	9	simulation	simulation	NOUN
ap-2293	7	10	..	..	PROPN
ap-2293	7	11	1	1	X
ap-2293	7	12	.	.	X
ap-2293	7	13	introduction	introduction	NOUN
ap-2293	7	14	the	the	DET
ap-2293	7	15	cooling	cool	VERB
ap-2293	7	16	performance	performance	NOUN
ap-2293	7	17	of	of	ADP
ap-2293	7	18	cooling	cool	VERB
ap-2293	7	19	units	unit	NOUN
ap-2293	7	20	working	work	VERB
ap-2293	7	21	on	on	ADP
ap-2293	7	22	the	the	DET
ap-2293	7	23	principle	principle	NOUN
ap-2293	7	24	of	of	ADP
ap-2293	7	25	coolant	coolant	NOUN
ap-2293	7	26	compression	compression	NOUN
ap-2293	7	27	and	and	CCONJ
ap-2293	7	28	expansion	expansion	NOUN
ap-2293	7	29	depends	depend	VERB
ap-2293	7	30	on	on	ADP
ap-2293	7	31	the	the	DET
ap-2293	7	32	operating	operate	VERB
ap-2293	7	33	temperature	temperature	NOUN
ap-2293	7	34	of	of	ADP
ap-2293	7	35	the	the	DET
ap-2293	7	36	evaporator	evaporator	NOUN
ap-2293	7	37	.	.	PUNCT
ap-2293	8	1	the	the	DET
ap-2293	8	2	heat	heat	NOUN
ap-2293	8	3	transport	transport	NOUN
ap-2293	8	4	from	from	ADP
ap-2293	8	5	the	the	DET
ap-2293	8	6	aggregate	aggregate	NOUN
ap-2293	8	7	to	to	ADP
ap-2293	8	8	the	the	DET
ap-2293	8	9	appliance	appliance	NOUN
ap-2293	8	10	is	be	AUX
ap-2293	8	11	done	do	VERB
ap-2293	8	12	via	via	ADP
ap-2293	8	13	heat	heat	NOUN
ap-2293	8	14	transferring	transfer	VERB
ap-2293	8	15	medium	medium	NOUN
ap-2293	8	16	,	,	PUNCT
ap-2293	8	17	which	which	PRON
ap-2293	8	18	is	be	AUX
ap-2293	8	19	usually	usually	ADV
ap-2293	8	20	an	an	DET
ap-2293	8	21	anti	anti	ADJ
ap-2293	8	22	-	-	ADJ
ap-2293	8	23	freeze	freeze	ADJ
ap-2293	8	24	fluid	fluid	NOUN
ap-2293	8	25	.	.	PUNCT
ap-2293	9	1	the	the	DET
ap-2293	9	2	appliance	appliance	NOUN
ap-2293	9	3	used	use	VERB
ap-2293	9	4	for	for	ADP
ap-2293	9	5	cooling	cool	VERB
ap-2293	9	6	of	of	ADP
ap-2293	9	7	various	various	ADJ
ap-2293	9	8	solutions	solution	NOUN
ap-2293	9	9	(	(	PUNCT
ap-2293	9	10	such	such	ADJ
ap-2293	9	11	as	as	ADP
ap-2293	9	12	stums	stum	NOUN
ap-2293	9	13	)	)	PUNCT
ap-2293	9	14	is	be	AUX
ap-2293	9	15	a	a	DET
ap-2293	9	16	heat	heat	NOUN
ap-2293	9	17	exchanger	exchanger	NOUN
ap-2293	9	18	(	(	PUNCT
ap-2293	9	19	cooling	cool	VERB
ap-2293	9	20	panel	panel	NOUN
ap-2293	9	21	)	)	PUNCT
ap-2293	9	22	.	.	PUNCT
ap-2293	10	1	the	the	DET
ap-2293	10	2	heat	heat	NOUN
ap-2293	10	3	in	in	ADP
ap-2293	10	4	the	the	DET
ap-2293	10	5	primary	primary	ADJ
ap-2293	10	6	circuit	circuit	NOUN
ap-2293	10	7	is	be	AUX
ap-2293	10	8	transferred	transfer	VERB
ap-2293	10	9	by	by	ADP
ap-2293	10	10	force	force	NOUN
ap-2293	10	11	convection	convection	NOUN
ap-2293	10	12	;	;	PUNCT
ap-2293	10	13	the	the	DET
ap-2293	10	14	heat	heat	NOUN
ap-2293	10	15	in	in	ADP
ap-2293	10	16	the	the	DET
ap-2293	10	17	secondary	secondary	ADJ
ap-2293	10	18	circuit	circuit	NOUN
ap-2293	10	19	is	be	AUX
ap-2293	10	20	led	lead	VERB
ap-2293	10	21	away	away	ADV
ap-2293	10	22	by	by	ADP
ap-2293	10	23	free	free	ADJ
ap-2293	10	24	convection	convection	NOUN
ap-2293	10	25	.	.	PUNCT
ap-2293	11	1	in	in	ADP
ap-2293	11	2	order	order	NOUN
ap-2293	11	3	to	to	PART
ap-2293	11	4	determine	determine	VERB
ap-2293	11	5	the	the	DET
ap-2293	11	6	dependence	dependence	NOUN
ap-2293	11	7	of	of	ADP
ap-2293	11	8	solution	solution	NOUN
ap-2293	11	9	temperature	temperature	NOUN
ap-2293	11	10	on	on	ADP
ap-2293	11	11	time	time	NOUN
ap-2293	11	12	during	during	ADP
ap-2293	11	13	the	the	DET
ap-2293	11	14	cooling	cooling	NOUN
ap-2293	11	15	,	,	PUNCT
ap-2293	11	16	it	it	PRON
ap-2293	11	17	is	be	AUX
ap-2293	11	18	necessary	necessary	ADJ
ap-2293	11	19	to	to	PART
ap-2293	11	20	know	know	VERB
ap-2293	11	21	the	the	DET
ap-2293	11	22	cooling	cool	VERB
ap-2293	11	23	performance	performance	NOUN
ap-2293	11	24	of	of	ADP
ap-2293	11	25	the	the	DET
ap-2293	11	26	heat	heat	NOUN
ap-2293	11	27	transfer	transfer	NOUN
ap-2293	11	28	surface	surface	NOUN
ap-2293	11	29	.	.	PUNCT
ap-2293	12	1	the	the	DET
ap-2293	12	2	performance	performance	NOUN
ap-2293	12	3	is	be	AUX
ap-2293	12	4	dependent	dependent	ADJ
ap-2293	12	5	on	on	ADP
ap-2293	12	6	the	the	DET
ap-2293	12	7	geometric	geometric	ADJ
ap-2293	12	8	shape	shape	NOUN
ap-2293	12	9	,	,	PUNCT
ap-2293	12	10	the	the	DET
ap-2293	12	11	physical	physical	ADJ
ap-2293	12	12	properties	property	NOUN
ap-2293	12	13	of	of	ADP
ap-2293	12	14	the	the	DET
ap-2293	12	15	heat	heat	NOUN
ap-2293	12	16	transfer	transfer	NOUN
ap-2293	12	17	material	material	NOUN
ap-2293	12	18	,	,	PUNCT
ap-2293	12	19	the	the	DET
ap-2293	12	20	material	material	NOUN
ap-2293	12	21	characteristics	characteristic	NOUN
ap-2293	12	22	of	of	ADP
ap-2293	12	23	the	the	DET
ap-2293	12	24	panel	panel	NOUN
ap-2293	12	25	,	,	PUNCT
ap-2293	12	26	the	the	DET
ap-2293	12	27	physical	physical	ADJ
ap-2293	12	28	characteristics	characteristic	NOUN
ap-2293	12	29	of	of	ADP
ap-2293	12	30	the	the	DET
ap-2293	12	31	solution	solution	NOUN
ap-2293	12	32	from	from	ADP
ap-2293	12	33	which	which	PRON
ap-2293	12	34	the	the	DET
ap-2293	12	35	heat	heat	NOUN
ap-2293	12	36	flow	flow	NOUN
ap-2293	12	37	is	be	AUX
ap-2293	12	38	led	lead	VERB
ap-2293	12	39	away	away	ADV
ap-2293	12	40	,	,	PUNCT
ap-2293	12	41	and	and	CCONJ
ap-2293	12	42	on	on	ADP
ap-2293	12	43	the	the	DET
ap-2293	12	44	temperature	temperature	NOUN
ap-2293	12	45	gradient	gradient	NOUN
ap-2293	12	46	between	between	ADP
ap-2293	12	47	the	the	DET
ap-2293	12	48	panel	panel	NOUN
ap-2293	12	49	and	and	CCONJ
ap-2293	12	50	the	the	DET
ap-2293	12	51	solution	solution	NOUN
ap-2293	12	52	.	.	PUNCT
ap-2293	13	1	by	by	ADP
ap-2293	13	2	increasing	increase	VERB
ap-2293	13	3	the	the	DET
ap-2293	13	4	temperature	temperature	NOUN
ap-2293	13	5	gradient	gradient	NOUN
ap-2293	13	6	,	,	PUNCT
ap-2293	13	7	the	the	DET
ap-2293	13	8	performance	performance	NOUN
ap-2293	13	9	of	of	ADP
ap-2293	13	10	the	the	DET
ap-2293	13	11	cooling	cool	VERB
ap-2293	13	12	panel	panel	NOUN
ap-2293	13	13	increases	increase	NOUN
ap-2293	13	14	,	,	PUNCT
ap-2293	13	15	but	but	CCONJ
ap-2293	13	16	the	the	DET
ap-2293	13	17	performance	performance	NOUN
ap-2293	13	18	demand	demand	NOUN
ap-2293	13	19	of	of	ADP
ap-2293	13	20	the	the	DET
ap-2293	13	21	cooling	cool	VERB
ap-2293	13	22	device	device	NOUN
ap-2293	13	23	decreases	decrease	VERB
ap-2293	13	24	.	.	PUNCT
ap-2293	14	1	the	the	DET
ap-2293	14	2	derivation	derivation	NOUN
ap-2293	14	3	of	of	ADP
ap-2293	14	4	the	the	DET
ap-2293	14	5	mathematical	mathematical	ADJ
ap-2293	14	6	dependencies	dependency	NOUN
ap-2293	14	7	describing	describe	VERB
ap-2293	14	8	the	the	DET
ap-2293	14	9	balanced	balanced	ADJ
ap-2293	14	10	thermodynamic	thermodynamic	ADJ
ap-2293	14	11	state	state	NOUN
ap-2293	14	12	of	of	ADP
ap-2293	14	13	this	this	DET
ap-2293	14	14	process	process	NOUN
ap-2293	14	15	is	be	AUX
ap-2293	14	16	the	the	DET
ap-2293	14	17	basic	basic	ADJ
ap-2293	14	18	presupposition	presupposition	NOUN
ap-2293	14	19	allowing	allow	VERB
ap-2293	14	20	us	we	PRON
ap-2293	14	21	to	to	PART
ap-2293	14	22	design	design	VERB
ap-2293	14	23	devices	device	NOUN
ap-2293	14	24	of	of	ADP
ap-2293	14	25	this	this	DET
ap-2293	14	26	kind	kind	NOUN
ap-2293	14	27	.	.	PUNCT
ap-2293	15	1	when	when	SCONJ
ap-2293	15	2	determining	determine	VERB
ap-2293	15	3	the	the	DET
ap-2293	15	4	cooling	cool	VERB
ap-2293	15	5	performance	performance	NOUN
ap-2293	15	6	of	of	ADP
ap-2293	15	7	the	the	DET
ap-2293	15	8	panel	panel	NOUN
ap-2293	15	9	,	,	PUNCT
ap-2293	15	10	criteria	criterion	NOUN
ap-2293	15	11	equations	equation	NOUN
ap-2293	15	12	are	be	AUX
ap-2293	15	13	used	use	VERB
ap-2293	15	14	from	from	ADP
ap-2293	15	15	which	which	PRON
ap-2293	15	16	we	we	PRON
ap-2293	15	17	can	can	AUX
ap-2293	15	18	calculate	calculate	VERB
ap-2293	15	19	the	the	DET
ap-2293	15	20	htc	htc	NOUN
ap-2293	15	21	(	(	PUNCT
ap-2293	15	22	heat	heat	NOUN
ap-2293	15	23	transfer	transfer	NOUN
ap-2293	15	24	coefficient	coefficient	NOUN
ap-2293	15	25	)	)	PUNCT
ap-2293	15	26	between	between	ADP
ap-2293	15	27	the	the	DET
ap-2293	15	28	external	external	ADJ
ap-2293	15	29	heat	heat	NOUN
ap-2293	15	30	exchanging	exchange	VERB
ap-2293	15	31	surface	surface	NOUN
ap-2293	15	32	and	and	CCONJ
ap-2293	15	33	the	the	DET
ap-2293	15	34	cooled	cooled	ADJ
ap-2293	15	35	solution	solution	NOUN
ap-2293	15	36	.	.	PUNCT
ap-2293	16	1	however	however	ADV
ap-2293	16	2	,	,	PUNCT
ap-2293	16	3	there	there	PRON
ap-2293	16	4	is	be	VERB
ap-2293	16	5	a	a	DET
ap-2293	16	6	problem	problem	NOUN
ap-2293	16	7	with	with	ADP
ap-2293	16	8	defining	define	VERB
ap-2293	16	9	the	the	DET
ap-2293	16	10	average	average	ADJ
ap-2293	16	11	panel	panel	NOUN
ap-2293	16	12	temperature	temperature	NOUN
ap-2293	16	13	,	,	PUNCT
ap-2293	16	14	as	as	SCONJ
ap-2293	16	15	the	the	DET
ap-2293	16	16	temperature	temperature	NOUN
ap-2293	16	17	arrangement	arrangement	NOUN
ap-2293	16	18	on	on	ADP
ap-2293	16	19	the	the	DET
ap-2293	16	20	heat	heat	NOUN
ap-2293	16	21	exchanging	exchange	VERB
ap-2293	16	22	panel	panel	NOUN
ap-2293	16	23	may	may	AUX
ap-2293	16	24	be	be	AUX
ap-2293	16	25	significantly	significantly	ADV
ap-2293	16	26	uneven	uneven	ADJ
ap-2293	16	27	.	.	PUNCT
ap-2293	17	1	for	for	ADP
ap-2293	17	2	this	this	DET
ap-2293	17	3	reason	reason	NOUN
ap-2293	17	4	,	,	PUNCT
ap-2293	17	5	it	it	PRON
ap-2293	17	6	is	be	AUX
ap-2293	17	7	better	well	ADJ
ap-2293	17	8	to	to	PART
ap-2293	17	9	execute	execute	VERB
ap-2293	17	10	the	the	DET
ap-2293	17	11	calculation	calculation	NOUN
ap-2293	17	12	using	use	VERB
ap-2293	17	13	a	a	DET
ap-2293	17	14	numerical	numerical	ADJ
ap-2293	17	15	method	method	NOUN
ap-2293	17	16	,	,	PUNCT
ap-2293	17	17	for	for	ADP
ap-2293	17	18	example	example	NOUN
ap-2293	17	19	using	use	VERB
ap-2293	17	20	the	the	DET
ap-2293	17	21	ansys	ansys	PROPN
ap-2293	17	22	cfx	cfx	PROPN
ap-2293	17	23	program	program	PROPN
ap-2293	17	24	.	.	PUNCT
ap-2293	18	1	the	the	DET
ap-2293	18	2	final	final	ADJ
ap-2293	18	3	mathematical	mathematical	ADJ
ap-2293	18	4	model	model	NOUN
ap-2293	18	5	has	have	AUX
ap-2293	18	6	been	be	AUX
ap-2293	18	7	used	use	VERB
ap-2293	18	8	to	to	PART
ap-2293	18	9	verify	verify	VERB
ap-2293	18	10	the	the	DET
ap-2293	18	11	thermal	thermal	ADJ
ap-2293	18	12	performance	performance	NOUN
ap-2293	18	13	of	of	ADP
ap-2293	18	14	a	a	DET
ap-2293	18	15	particular	particular	ADJ
ap-2293	18	16	device	device	NOUN
ap-2293	18	17	intended	intend	VERB
ap-2293	18	18	to	to	PART
ap-2293	18	19	cool	cool	VERB
ap-2293	18	20	the	the	DET
ap-2293	18	21	stum	stum	NOUN
ap-2293	18	22	.	.	PUNCT
ap-2293	19	1	the	the	DET
ap-2293	19	2	cooling	cool	VERB
ap-2293	19	3	aggregate	aggregate	ADJ
ap-2293	19	4	performance	performance	NOUN
ap-2293	19	5	of	of	ADP
ap-2293	19	6	the	the	DET
ap-2293	19	7	jn30	jn30	PROPN
ap-2293	19	8	type	type	NOUN
ap-2293	19	9	is	be	AUX
ap-2293	19	10	27.5	27.5	NUM
ap-2293	19	11	kw	kw	NOUN
ap-2293	19	12	at	at	ADP
ap-2293	19	13	a	a	DET
ap-2293	19	14	cooling	cool	VERB
ap-2293	19	15	mixture	mixture	NOUN
ap-2293	19	16	temperature	temperature	NOUN
ap-2293	19	17	of	of	ADP
ap-2293	19	18	13	13	NUM
ap-2293	19	19	°	°	NOUN
ap-2293	19	20	c	c	NOUN
ap-2293	19	21	.	.	PUNCT
ap-2293	20	1	the	the	DET
ap-2293	20	2	aggregate	aggregate	ADJ
ap-2293	20	3	works	work	NOUN
ap-2293	20	4	at	at	ADP
ap-2293	20	5	a	a	DET
ap-2293	20	6	pressure	pressure	NOUN
ap-2293	20	7	of	of	ADP
ap-2293	20	8	2.5	2.5	NUM
ap-2293	20	9	bar	bar	NOUN
ap-2293	20	10	and	and	CCONJ
ap-2293	20	11	at	at	ADP
ap-2293	20	12	a	a	DET
ap-2293	20	13	cooling	cool	VERB
ap-2293	20	14	mixture	mixture	NOUN
ap-2293	20	15	flow	flow	NOUN
ap-2293	20	16	of	of	ADP
ap-2293	20	17	120	120	NUM
ap-2293	20	18	lmin−1	lmin−1	PROPN
ap-2293	20	19	.	.	PUNCT
ap-2293	21	1	the	the	DET
ap-2293	21	2	volume	volume	NOUN
ap-2293	21	3	of	of	ADP
ap-2293	21	4	the	the	DET
ap-2293	21	5	cooling	cool	VERB
ap-2293	21	6	mixture	mixture	NOUN
ap-2293	21	7	tank	tank	NOUN
ap-2293	21	8	is	be	AUX
ap-2293	21	9	330	330	NUM
ap-2293	21	10	litres	litre	NOUN
ap-2293	21	11	.	.	PUNCT
ap-2293	22	1	the	the	DET
ap-2293	22	2	device	device	NOUN
ap-2293	22	3	cools	cool	VERB
ap-2293	22	4	down	down	ADV
ap-2293	22	5	22	22	NUM
ap-2293	22	6	tanks	tank	NOUN
ap-2293	22	7	with	with	ADP
ap-2293	22	8	a	a	DET
ap-2293	22	9	volume	volume	NOUN
ap-2293	22	10	of	of	ADP
ap-2293	22	11	3230	3230	NUM
ap-2293	22	12	litres	litre	NOUN
ap-2293	22	13	(	(	PUNCT
ap-2293	22	14	t1400	t1400	ADP
ap-2293	22	15	tank	tank	NOUN
ap-2293	22	16	type	type	NOUN
ap-2293	22	17	)	)	PUNCT
ap-2293	22	18	and	and	CCONJ
ap-2293	22	19	5	5	NUM
ap-2293	22	20	tanks	tank	NOUN
ap-2293	22	21	with	with	ADP
ap-2293	22	22	a	a	DET
ap-2293	22	23	volume	volume	NOUN
ap-2293	22	24	of	of	ADP
ap-2293	22	25	1430	1430	NUM
ap-2293	22	26	litres	litre	NOUN
ap-2293	22	27	(	(	PUNCT
ap-2293	22	28	t930	t930	NUM
ap-2293	22	29	type	type	NOUN
ap-2293	22	30	)	)	PUNCT
ap-2293	22	31	,	,	PUNCT
ap-2293	22	32	which	which	PRON
ap-2293	22	33	equals	equal	VERB
ap-2293	22	34	78210	78210	NUM
ap-2293	22	35	litres	litre	NOUN
ap-2293	22	36	of	of	ADP
ap-2293	22	37	stum	stum	NOUN
ap-2293	22	38	in	in	ADP
ap-2293	22	39	total	total	NOUN
ap-2293	22	40	.	.	PUNCT
ap-2293	23	1	the	the	DET
ap-2293	23	2	mathematical	mathematical	ADJ
ap-2293	23	3	model	model	NOUN
ap-2293	23	4	requires	require	VERB
ap-2293	23	5	a	a	DET
ap-2293	23	6	knowledge	knowledge	NOUN
ap-2293	23	7	of	of	ADP
ap-2293	23	8	the	the	DET
ap-2293	23	9	functional	functional	ADJ
ap-2293	23	10	dependence	dependence	NOUN
ap-2293	23	11	of	of	ADP
ap-2293	23	12	the	the	DET
ap-2293	23	13	cooling	cool	VERB
ap-2293	23	14	performance	performance	NOUN
ap-2293	23	15	(	(	PUNCT
ap-2293	23	16	pch	pch	ADJ
ap-2293	23	17	)	)	PUNCT
ap-2293	23	18	on	on	ADP
ap-2293	23	19	the	the	DET
ap-2293	23	20	cooling	cool	VERB
ap-2293	23	21	mixture	mixture	NOUN
ap-2293	23	22	temperature	temperature	NOUN
ap-2293	23	23	at	at	ADP
ap-2293	23	24	the	the	DET
ap-2293	23	25	entrance	entrance	NOUN
ap-2293	23	26	to	to	ADP
ap-2293	23	27	the	the	DET
ap-2293	23	28	cooling	cool	VERB
ap-2293	23	29	panel	panel	NOUN
ap-2293	23	30	(	(	PUNCT
ap-2293	23	31	tv1	tv1	PROPN
ap-2293	23	32	)	)	PUNCT
ap-2293	23	33	.	.	PUNCT
ap-2293	24	1	using	use	VERB
ap-2293	24	2	the	the	DET
ap-2293	24	3	data	datum	NOUN
ap-2293	24	4	from	from	ADP
ap-2293	24	5	the	the	DET
ap-2293	24	6	technical	technical	ADJ
ap-2293	24	7	documentation	documentation	NOUN
ap-2293	24	8	of	of	ADP
ap-2293	24	9	the	the	DET
ap-2293	24	10	jn30	jn30	PROPN
ap-2293	24	11	device	device	NOUN
ap-2293	24	12	,	,	PUNCT
ap-2293	24	13	a	a	DET
ap-2293	24	14	regression	regression	NOUN
ap-2293	24	15	equation	equation	NOUN
ap-2293	24	16	in	in	ADP
ap-2293	24	17	the	the	DET
ap-2293	24	18	following	follow	VERB
ap-2293	24	19	form	form	NOUN
ap-2293	24	20	was	be	AUX
ap-2293	24	21	derived	derive	VERB
ap-2293	24	22	:	:	PUNCT
ap-2293	25	1	pch	pch	ADJ
ap-2293	25	2	=	=	X
ap-2293	25	3	atv1	atv1	PROPN
ap-2293	26	1	+	+	NUM
ap-2293	26	2	b	b	X
ap-2293	26	3	=	=	SYM
ap-2293	26	4	938.98tv1	938.98tv1	NOUN
ap-2293	27	1	+	+	CCONJ
ap-2293	27	2	15380	15380	NUM
ap-2293	27	3	.	.	PUNCT
ap-2293	28	1	(	(	PUNCT
ap-2293	28	2	1	1	X
ap-2293	28	3	)	)	PUNCT
ap-2293	28	4	at	at	ADP
ap-2293	28	5	a	a	DET
ap-2293	28	6	temperature	temperature	NOUN
ap-2293	28	7	of	of	ADP
ap-2293	28	8	approximately	approximately	ADV
ap-2293	28	9	0	0	NUM
ap-2293	28	10	°	°	PRON
ap-2293	28	11	c	c	NOUN
ap-2293	28	12	,	,	PUNCT
ap-2293	28	13	the	the	DET
ap-2293	28	14	cooling	cool	VERB
ap-2293	28	15	performance	performance	NOUN
ap-2293	28	16	of	of	ADP
ap-2293	28	17	the	the	DET
ap-2293	28	18	installed	instal	VERB
ap-2293	28	19	device	device	NOUN
ap-2293	28	20	falls	fall	VERB
ap-2293	28	21	to	to	ADP
ap-2293	28	22	approximately	approximately	ADV
ap-2293	28	23	15	15	NUM
ap-2293	28	24	kw	kw	NOUN
ap-2293	28	25	.	.	PUNCT
ap-2293	29	1	cooling	cool	VERB
ap-2293	29	2	the	the	DET
ap-2293	29	3	stum	stum	NOUN
ap-2293	29	4	cooling	cool	VERB
ap-2293	29	5	to	to	ADP
ap-2293	29	6	the	the	DET
ap-2293	29	7	temperature	temperature	NOUN
ap-2293	29	8	of	of	ADP
ap-2293	29	9	approximately	approximately	ADV
ap-2293	29	10	0	0	NUM
ap-2293	29	11	°	°	ADP
ap-2293	29	12	c	c	NOUN
ap-2293	29	13	in	in	ADP
ap-2293	29	14	2	2	NUM
ap-2293	29	15	days	day	NOUN
ap-2293	29	16	requires	require	VERB
ap-2293	29	17	an	an	DET
ap-2293	29	18	increase	increase	NOUN
ap-2293	29	19	in	in	ADP
ap-2293	29	20	the	the	DET
ap-2293	29	21	cooling	cool	VERB
ap-2293	29	22	aggregate	aggregate	ADJ
ap-2293	29	23	performance	performance	NOUN
ap-2293	29	24	.	.	PUNCT
ap-2293	30	1	that	that	PRON
ap-2293	30	2	is	be	AUX
ap-2293	30	3	why	why	SCONJ
ap-2293	30	4	the	the	DET
ap-2293	30	5	calculation	calculation	NOUN
ap-2293	30	6	is	be	AUX
ap-2293	30	7	focused	focus	VERB
ap-2293	30	8	on	on	ADP
ap-2293	30	9	the	the	DET
ap-2293	30	10	heat	heat	NOUN
ap-2293	30	11	transfer	transfer	NOUN
ap-2293	30	12	in	in	ADP
ap-2293	30	13	the	the	DET
ap-2293	30	14	cooling	cool	VERB
ap-2293	30	15	panels	panel	NOUN
ap-2293	30	16	,	,	PUNCT
ap-2293	30	17	as	as	ADV
ap-2293	30	18	well	well	ADV
ap-2293	30	19	as	as	ADP
ap-2293	30	20	on	on	ADP
ap-2293	30	21	obtaining	obtain	VERB
ap-2293	30	22	the	the	DET
ap-2293	30	23	cooling	cool	VERB
ap-2293	30	24	curve	curve	NOUN
ap-2293	30	25	for	for	ADP
ap-2293	30	26	100	100	NUM
ap-2293	30	27	%	%	NOUN
ap-2293	30	28	of	of	ADP
ap-2293	30	29	the	the	DET
ap-2293	30	30	volume	volume	NOUN
ap-2293	30	31	of	of	ADP
ap-2293	30	32	the	the	DET
ap-2293	30	33	cooled	cooled	ADJ
ap-2293	30	34	stum	stum	NOUN
ap-2293	30	35	,	,	PUNCT
ap-2293	30	36	and	and	CCONJ
ap-2293	30	37	on	on	ADP
ap-2293	30	38	the	the	DET
ap-2293	30	39	minimum	minimum	ADJ
ap-2293	30	40	cooling	cool	VERB
ap-2293	30	41	performance	performance	NOUN
ap-2293	30	42	necessary	necessary	ADJ
ap-2293	30	43	to	to	PART
ap-2293	30	44	meet	meet	VERB
ap-2293	30	45	the	the	DET
ap-2293	30	46	requirement	requirement	NOUN
ap-2293	30	47	of	of	ADP
ap-2293	30	48	the	the	DET
ap-2293	30	49	stum	stum	NOUN
ap-2293	30	50	cooling	cooling	NOUN
ap-2293	30	51	.	.	PUNCT
ap-2293	31	1	140	140	NUM
ap-2293	31	2	http://dx.doi.org/10.14311/ap.2015.55.0140	http://dx.doi.org/10.14311/ap.2015.55.0140	NOUN
ap-2293	31	3	http://ojs.cvut.cz/ojs/index.php/ap	http://ojs.cvut.cz/ojs/index.php/ap	PROPN
ap-2293	31	4	vol	vol	NOUN
ap-2293	31	5	.	.	PUNCT
ap-2293	32	1	55	55	NUM
ap-2293	32	2	no	no	NOUN
ap-2293	32	3	.	.	PUNCT
ap-2293	33	1	3/2015	3/2015	NUM
ap-2293	33	2	simulation	simulation	NOUN
ap-2293	33	3	of	of	ADP
ap-2293	33	4	heat	heat	NOUN
ap-2293	33	5	transport	transport	NOUN
ap-2293	33	6	figure	figure	NOUN
ap-2293	33	7	1	1	NUM
ap-2293	33	8	.	.	PUNCT
ap-2293	33	9	dependence	dependence	NOUN
ap-2293	33	10	of	of	ADP
ap-2293	33	11	the	the	DET
ap-2293	33	12	specific	specific	ADJ
ap-2293	33	13	thermal	thermal	ADJ
ap-2293	33	14	capacity	capacity	NOUN
ap-2293	33	15	of	of	ADP
ap-2293	33	16	the	the	DET
ap-2293	33	17	30	30	NUM
ap-2293	33	18	%	%	NOUN
ap-2293	33	19	sugar	sugar	NOUN
ap-2293	33	20	solution	solution	NOUN
ap-2293	33	21	on	on	ADP
ap-2293	33	22	the	the	DET
ap-2293	33	23	temperature	temperature	NOUN
ap-2293	33	24	.	.	PUNCT
ap-2293	34	1	entered	enter	VERB
ap-2293	34	2	values	value	NOUN
ap-2293	34	3	∆tn	∆tn	X
ap-2293	34	4	(	(	PUNCT
ap-2293	34	5	°	°	ADP
ap-2293	34	6	c	c	NOUN
ap-2293	34	7	)	)	PUNCT
ap-2293	34	8	−4	−4	X
ap-2293	35	1	−8	−8	NOUN
ap-2293	35	2	−15	−15	X
ap-2293	35	3	−20	−20	PROPN
ap-2293	35	4	s	s	PART
ap-2293	35	5	(	(	PUNCT
ap-2293	35	6	m2	m2	PROPN
ap-2293	35	7	)	)	PUNCT
ap-2293	35	8	1.1627	1.1627	NUM
ap-2293	35	9	tv1	tv1	PROPN
ap-2293	35	10	(	(	PUNCT
ap-2293	35	11	°	°	ADP
ap-2293	35	12	c	c	NOUN
ap-2293	35	13	)	)	PUNCT
ap-2293	35	14	−4	−4	X
ap-2293	36	1	qm	qm	PROPN
ap-2293	36	2	(	(	PUNCT
ap-2293	36	3	kg	kg	PROPN
ap-2293	36	4	s−1	s−1	PROPN
ap-2293	36	5	)	)	PUNCT
ap-2293	36	6	0.0773	0.0773	NUM
ap-2293	36	7	calculated	calculate	VERB
ap-2293	36	8	values	value	NOUN
ap-2293	36	9	t	t	PROPN
ap-2293	36	10	(	(	PUNCT
ap-2293	36	11	°	°	ADP
ap-2293	36	12	c	c	NOUN
ap-2293	36	13	)	)	PUNCT
ap-2293	36	14	0	0	NUM
ap-2293	36	15	4	4	NUM
ap-2293	36	16	1	1	NUM
ap-2293	36	17	16	16	NUM
ap-2293	36	18	cstr	cstr	NOUN
ap-2293	36	19	(	(	PUNCT
ap-2293	36	20	j	j	PROPN
ap-2293	36	21	kg−1	kg−1	PROPN
ap-2293	36	22	k−1	k−1	PROPN
ap-2293	36	23	)	)	PUNCT
ap-2293	36	24	3699	3699	NUM
ap-2293	36	25	3702	3702	NUM
ap-2293	36	26	3704.7	3704.7	NUM
ap-2293	36	27	3707.4	3707.4	NUM
ap-2293	36	28	tv2	tv2	NOUN
ap-2293	36	29	(	(	PUNCT
ap-2293	36	30	°	°	ADP
ap-2293	36	31	c	c	NOUN
ap-2293	36	32	)	)	PUNCT
ap-2293	36	33	−3.053	−3.053	PROPN
ap-2293	36	34	−1.892	−1.892	PROPN
ap-2293	36	35	0.586	0.586	NUM
ap-2293	36	36	2.704	2.704	NUM
ap-2293	36	37	tstr	tstr	NOUN
ap-2293	36	38	-	-	PUNCT
ap-2293	36	39	panel	panel	NOUN
ap-2293	36	40	(	(	PUNCT
ap-2293	36	41	°	°	ADP
ap-2293	36	42	c	c	NOUN
ap-2293	36	43	)	)	PUNCT
ap-2293	36	44	−1.491	−1.491	NOUN
ap-2293	36	45	1.413	1.413	NUM
ap-2293	36	46	7.198	7.198	NUM
ap-2293	36	47	11.812	11.812	NUM
ap-2293	36	48	αpanel	αpanel	NOUN
ap-2293	36	49	(	(	PUNCT
ap-2293	36	50	wm−2	wm−2	PROPN
ap-2293	36	51	k−1	k−1	PROPN
ap-2293	36	52	)	)	PUNCT
ap-2293	36	53	159.4	159.4	NUM
ap-2293	36	54	205.4	205.4	NUM
ap-2293	36	55	305.5	305.5	NUM
ap-2293	36	56	406.7	406.7	NUM
ap-2293	36	57	pch	pch	ADJ
ap-2293	36	58	,	,	PUNCT
ap-2293	36	59	panel	panel	NOUN
ap-2293	36	60	(	(	PUNCT
ap-2293	36	61	w	w	NOUN
ap-2293	36	62	)	)	PUNCT
ap-2293	36	63	270.8	270.8	NUM
ap-2293	36	64	603.2	603.2	NUM
ap-2293	36	65	1313.3	1313.3	NUM
ap-2293	36	66	1921.2	1921.2	NUM
ap-2293	36	67	pch	pch	ADJ
ap-2293	36	68	(	(	PUNCT
ap-2293	36	69	w	w	NOUN
ap-2293	36	70	)	)	PUNCT
ap-2293	36	71	6634	6634	NUM
ap-2293	36	72	14779	14779	NUM
ap-2293	36	73	32176	32176	NUM
ap-2293	36	74	47071	47071	NUM
ap-2293	36	75	table	table	NOUN
ap-2293	36	76	1	1	NUM
ap-2293	36	77	.	.	PUNCT
ap-2293	36	78	entered	enter	VERB
ap-2293	36	79	and	and	CCONJ
ap-2293	36	80	calculated	calculated	ADJ
ap-2293	36	81	values	value	NOUN
ap-2293	36	82	.	.	PUNCT
ap-2293	37	1	2	2	X
ap-2293	37	2	.	.	X
ap-2293	37	3	heat	heat	NOUN
ap-2293	37	4	transfer	transfer	NOUN
ap-2293	37	5	in	in	ADP
ap-2293	37	6	the	the	DET
ap-2293	37	7	cooling	cool	VERB
ap-2293	37	8	panels	panel	NOUN
ap-2293	37	9	in	in	ADP
ap-2293	37	10	order	order	NOUN
ap-2293	37	11	to	to	PART
ap-2293	37	12	construct	construct	VERB
ap-2293	37	13	the	the	DET
ap-2293	37	14	heat	heat	NOUN
ap-2293	37	15	exchanger	exchanger	NOUN
ap-2293	37	16	thermal	thermal	ADJ
ap-2293	37	17	balance	balance	NOUN
ap-2293	37	18	equation	equation	NOUN
ap-2293	37	19	,	,	PUNCT
ap-2293	37	20	it	it	PRON
ap-2293	37	21	is	be	AUX
ap-2293	37	22	necessary	necessary	ADJ
ap-2293	37	23	to	to	PART
ap-2293	37	24	know	know	VERB
ap-2293	37	25	the	the	DET
ap-2293	37	26	dependence	dependence	NOUN
ap-2293	37	27	of	of	ADP
ap-2293	37	28	the	the	DET
ap-2293	37	29	cooling	cool	VERB
ap-2293	37	30	performance	performance	NOUN
ap-2293	37	31	of	of	ADP
ap-2293	37	32	the	the	DET
ap-2293	37	33	panel	panel	NOUN
ap-2293	37	34	on	on	ADP
ap-2293	37	35	the	the	DET
ap-2293	37	36	temperature	temperature	NOUN
ap-2293	37	37	difference	difference	NOUN
ap-2293	37	38	(	(	PUNCT
ap-2293	37	39	∆tn	∆tn	NUM
ap-2293	37	40	)	)	PUNCT
ap-2293	37	41	between	between	ADP
ap-2293	37	42	the	the	DET
ap-2293	37	43	cooling	cool	VERB
ap-2293	37	44	mixture	mixture	NOUN
ap-2293	37	45	(	(	PUNCT
ap-2293	37	46	tv1	tv1	PROPN
ap-2293	37	47	)	)	PUNCT
ap-2293	37	48	and	and	CCONJ
ap-2293	37	49	the	the	DET
ap-2293	37	50	stum	stum	NOUN
ap-2293	37	51	temperature	temperature	NOUN
ap-2293	37	52	(	(	PUNCT
ap-2293	37	53	t	t	NOUN
ap-2293	37	54	)	)	PUNCT
ap-2293	37	55	.	.	PUNCT
ap-2293	38	1	in	in	ADP
ap-2293	38	2	order	order	NOUN
ap-2293	38	3	to	to	PART
ap-2293	38	4	achieve	achieve	VERB
ap-2293	38	5	this	this	PRON
ap-2293	38	6	,	,	PUNCT
ap-2293	38	7	numerical	numerical	ADJ
ap-2293	38	8	calculations	calculation	NOUN
ap-2293	38	9	for	for	ADP
ap-2293	38	10	four	four	NUM
ap-2293	38	11	temperature	temperature	NOUN
ap-2293	38	12	states	state	NOUN
ap-2293	38	13	have	have	AUX
ap-2293	38	14	been	be	AUX
ap-2293	38	15	made	make	VERB
ap-2293	38	16	(	(	PUNCT
ap-2293	38	17	at	at	ADP
ap-2293	38	18	the	the	DET
ap-2293	38	19	temperature	temperature	NOUN
ap-2293	38	20	differences	difference	NOUN
ap-2293	38	21	of	of	ADP
ap-2293	38	22	∆tn	∆tn	PROPN
ap-2293	38	23	=	=	PUNCT
ap-2293	38	24	−4,−8,−15,−20	−4,−8,−15,−20	PROPN
ap-2293	38	25	°	°	PROPN
ap-2293	38	26	c	c	NOUN
ap-2293	38	27	)	)	PUNCT
ap-2293	38	28	and	and	CCONJ
ap-2293	38	29	for	for	ADP
ap-2293	38	30	the	the	DET
ap-2293	38	31	nominal	nominal	ADJ
ap-2293	38	32	flow	flow	NOUN
ap-2293	38	33	of	of	ADP
ap-2293	38	34	the	the	DET
ap-2293	38	35	cooling	cool	VERB
ap-2293	38	36	mixture	mixture	NOUN
ap-2293	38	37	through	through	ADP
ap-2293	38	38	one	one	NUM
ap-2293	38	39	panel	panel	NOUN
ap-2293	38	40	of	of	ADP
ap-2293	38	41	7.407	7.407	NUM
ap-2293	38	42	·	·	PUNCT
ap-2293	38	43	10−5	10−5	NUM
ap-2293	38	44	m3	m3	PROPN
ap-2293	38	45	s−1	s−1	PROPN
ap-2293	38	46	(	(	PUNCT
ap-2293	38	47	corresponding	correspond	VERB
ap-2293	38	48	to	to	ADP
ap-2293	38	49	the	the	DET
ap-2293	38	50	total	total	ADJ
ap-2293	38	51	flow	flow	NOUN
ap-2293	38	52	of	of	ADP
ap-2293	38	53	120	120	NUM
ap-2293	38	54	lmin−1	lmin−1	NOUN
ap-2293	38	55	through	through	ADP
ap-2293	38	56	27	27	NUM
ap-2293	38	57	cooling	cool	VERB
ap-2293	38	58	panels	panel	NOUN
ap-2293	38	59	)	)	PUNCT
ap-2293	38	60	.	.	PUNCT
ap-2293	39	1	in	in	ADP
ap-2293	39	2	order	order	NOUN
ap-2293	39	3	to	to	PART
ap-2293	39	4	ensure	ensure	VERB
ap-2293	39	5	the	the	DET
ap-2293	39	6	temperature	temperature	NOUN
ap-2293	39	7	gradient	gradient	NOUN
ap-2293	39	8	between	between	ADP
ap-2293	39	9	the	the	DET
ap-2293	39	10	coolant	coolant	NOUN
ap-2293	39	11	and	and	CCONJ
ap-2293	39	12	the	the	DET
ap-2293	39	13	stum	stum	NOUN
ap-2293	39	14	,	,	PUNCT
ap-2293	39	15	the	the	DET
ap-2293	39	16	cooling	cool	VERB
ap-2293	39	17	mixture	mixture	NOUN
ap-2293	39	18	temperature	temperature	NOUN
ap-2293	39	19	must	must	AUX
ap-2293	39	20	be	be	AUX
ap-2293	39	21	constantly	constantly	ADV
ap-2293	39	22	lower	low	ADJ
ap-2293	39	23	than	than	ADP
ap-2293	39	24	the	the	DET
ap-2293	39	25	stum	stum	NOUN
ap-2293	39	26	temperature	temperature	NOUN
ap-2293	39	27	.	.	PUNCT
ap-2293	40	1	the	the	PRON
ap-2293	40	2	higher	high	ADJ
ap-2293	40	3	the	the	DET
ap-2293	40	4	absolute	absolute	ADJ
ap-2293	40	5	value	value	NOUN
ap-2293	40	6	of	of	ADP
ap-2293	40	7	the	the	DET
ap-2293	40	8	temperature	temperature	NOUN
ap-2293	40	9	difference	difference	NOUN
ap-2293	40	10	,	,	PUNCT
ap-2293	40	11	the	the	PRON
ap-2293	40	12	higher	high	ADJ
ap-2293	40	13	the	the	DET
ap-2293	40	14	panel	panel	NOUN
ap-2293	40	15	cooling	cool	VERB
ap-2293	40	16	performance	performance	NOUN
ap-2293	40	17	.	.	PUNCT
ap-2293	41	1	table	table	NOUN
ap-2293	41	2	1	1	NUM
ap-2293	41	3	shows	show	VERB
ap-2293	41	4	the	the	DET
ap-2293	41	5	values	value	NOUN
ap-2293	41	6	of	of	ADP
ap-2293	41	7	the	the	DET
ap-2293	41	8	input	input	NOUN
ap-2293	41	9	data	datum	NOUN
ap-2293	41	10	and	and	CCONJ
ap-2293	41	11	the	the	DET
ap-2293	41	12	values	value	NOUN
ap-2293	41	13	of	of	ADP
ap-2293	41	14	the	the	DET
ap-2293	41	15	relevant	relevant	ADJ
ap-2293	41	16	parameters	parameter	NOUN
ap-2293	41	17	calculated	calculate	VERB
ap-2293	41	18	by	by	ADP
ap-2293	41	19	analytic	analytic	ADJ
ap-2293	41	20	procedure	procedure	NOUN
ap-2293	41	21	or	or	CCONJ
ap-2293	41	22	by	by	ADP
ap-2293	41	23	numerical	numerical	PROPN
ap-2293	41	24	simulation	simulation	PROPN
ap-2293	41	25	.	.	PUNCT
ap-2293	42	1	in	in	ADP
ap-2293	42	2	table	table	NOUN
ap-2293	42	3	1	1	NUM
ap-2293	42	4	,	,	PUNCT
ap-2293	42	5	s	s	VERB
ap-2293	42	6	is	be	AUX
ap-2293	42	7	the	the	DET
ap-2293	42	8	real	real	ADJ
ap-2293	42	9	total	total	ADJ
ap-2293	42	10	heat	heat	NOUN
ap-2293	42	11	exchanging	exchange	VERB
ap-2293	42	12	surface	surface	NOUN
ap-2293	42	13	of	of	ADP
ap-2293	42	14	the	the	DET
ap-2293	42	15	cooling	cool	VERB
ap-2293	42	16	panel	panel	NOUN
ap-2293	42	17	(	(	PUNCT
ap-2293	42	18	m2	m2	PROPN
ap-2293	42	19	)	)	PUNCT
ap-2293	42	20	,	,	PUNCT
ap-2293	42	21	tv2	tv2	PROPN
ap-2293	42	22	is	be	AUX
ap-2293	42	23	the	the	DET
ap-2293	42	24	temperature	temperature	NOUN
ap-2293	42	25	of	of	ADP
ap-2293	42	26	the	the	DET
ap-2293	42	27	cooling	cool	VERB
ap-2293	42	28	mixture	mixture	NOUN
ap-2293	42	29	on	on	ADP
ap-2293	42	30	the	the	DET
ap-2293	42	31	cooling	cool	VERB
ap-2293	42	32	panel	panel	NOUN
ap-2293	42	33	output	output	NOUN
ap-2293	42	34	(	(	PUNCT
ap-2293	42	35	°	°	ADP
ap-2293	42	36	c	c	NOUN
ap-2293	42	37	)	)	PUNCT
ap-2293	42	38	,	,	PUNCT
ap-2293	42	39	tstr	tstr	NOUN
ap-2293	42	40	-	-	PUNCT
ap-2293	42	41	panel	panel	NOUN
ap-2293	42	42	is	be	AUX
ap-2293	42	43	the	the	DET
ap-2293	42	44	average	average	ADJ
ap-2293	42	45	temperature	temperature	NOUN
ap-2293	42	46	of	of	ADP
ap-2293	42	47	the	the	DET
ap-2293	42	48	rustless	rustless	PROPN
ap-2293	42	49	panel	panel	PROPN
ap-2293	42	50	surface	surface	PROPN
ap-2293	42	51	(	(	PUNCT
ap-2293	42	52	°	°	ADP
ap-2293	42	53	c	c	NOUN
ap-2293	42	54	)	)	PUNCT
ap-2293	42	55	,	,	PUNCT
ap-2293	42	56	cstr	cstr	NOUN
ap-2293	42	57	is	be	AUX
ap-2293	42	58	the	the	DET
ap-2293	42	59	thermal	thermal	ADJ
ap-2293	42	60	capacity	capacity	NOUN
ap-2293	42	61	of	of	ADP
ap-2293	42	62	the	the	DET
ap-2293	42	63	coolant	coolant	NOUN
ap-2293	42	64	at	at	ADP
ap-2293	42	65	its	its	PRON
ap-2293	42	66	average	average	ADJ
ap-2293	42	67	temperature	temperature	NOUN
ap-2293	42	68	(	(	PUNCT
ap-2293	42	69	j	j	PROPN
ap-2293	42	70	kg−1	kg−1	PROPN
ap-2293	42	71	k−1	k−1	PROPN
ap-2293	42	72	)	)	PUNCT
ap-2293	42	73	,	,	PUNCT
ap-2293	42	74	qm	qm	PROPN
ap-2293	42	75	is	be	AUX
ap-2293	42	76	the	the	DET
ap-2293	42	77	mass	mass	ADJ
ap-2293	42	78	flow	flow	NOUN
ap-2293	42	79	of	of	ADP
ap-2293	42	80	the	the	DET
ap-2293	42	81	coolant	coolant	NOUN
ap-2293	42	82	(	(	PUNCT
ap-2293	42	83	kg	kg	X
ap-2293	42	84	s−1	s−1	PROPN
ap-2293	42	85	)	)	PUNCT
ap-2293	42	86	,	,	PUNCT
ap-2293	42	87	αpanel	αpanel	NOUN
ap-2293	42	88	is	be	AUX
ap-2293	42	89	the	the	DET
ap-2293	42	90	heat	heat	NOUN
ap-2293	42	91	transfer	transfer	NOUN
ap-2293	42	92	coefficient	coefficient	NOUN
ap-2293	42	93	on	on	ADP
ap-2293	42	94	the	the	DET
ap-2293	42	95	panel	panel	NOUN
ap-2293	42	96	surface	surface	NOUN
ap-2293	42	97	(	(	PUNCT
ap-2293	42	98	wm−2	wm−2	PROPN
ap-2293	42	99	k−1	k−1	PROPN
ap-2293	42	100	)	)	PUNCT
ap-2293	42	101	,	,	PUNCT
ap-2293	42	102	pch	pch	PROPN
ap-2293	42	103	,	,	PUNCT
ap-2293	42	104	panel	panel	NOUN
ap-2293	42	105	is	be	AUX
ap-2293	42	106	the	the	DET
ap-2293	42	107	cooling	cool	VERB
ap-2293	42	108	performance	performance	NOUN
ap-2293	42	109	of	of	ADP
ap-2293	42	110	one	one	NUM
ap-2293	42	111	panel	panel	NOUN
ap-2293	42	112	(	(	PUNCT
ap-2293	42	113	w	w	NOUN
ap-2293	42	114	)	)	PUNCT
ap-2293	42	115	.	.	PUNCT
ap-2293	43	1	the	the	DET
ap-2293	43	2	heat	heat	NOUN
ap-2293	43	3	transfer	transfer	NOUN
ap-2293	43	4	coefficient	coefficient	NOUN
ap-2293	43	5	from	from	ADP
ap-2293	43	6	the	the	DET
ap-2293	43	7	stum	stum	NOUN
ap-2293	43	8	to	to	ADP
ap-2293	43	9	the	the	DET
ap-2293	43	10	cooling	cool	VERB
ap-2293	43	11	panel	panel	NOUN
ap-2293	43	12	surface	surface	NOUN
ap-2293	43	13	was	be	AUX
ap-2293	43	14	determined	determine	VERB
ap-2293	43	15	from	from	ADP
ap-2293	43	16	the	the	DET
ap-2293	43	17	criteria	criterion	NOUN
ap-2293	43	18	(	(	PUNCT
ap-2293	43	19	2	2	NUM
ap-2293	43	20	)	)	PUNCT
ap-2293	43	21	and	and	CCONJ
ap-2293	43	22	(	(	PUNCT
ap-2293	43	23	3	3	X
ap-2293	43	24	)	)	PUNCT
ap-2293	43	25	for	for	ADP
ap-2293	43	26	a	a	DET
ap-2293	43	27	free	free	ADJ
ap-2293	43	28	convection	convection	NOUN
ap-2293	43	29	at	at	ADP
ap-2293	43	30	the	the	DET
ap-2293	43	31	vertical	vertical	ADJ
ap-2293	43	32	panel	panel	NOUN
ap-2293	44	1	[	[	X
ap-2293	44	2	1	1	NUM
ap-2293	44	3	]	]	PUNCT
ap-2293	44	4	:	:	PUNCT
ap-2293	44	5	nu	nu	X
ap-2293	44	6	=	=	PUNCT
ap-2293	44	7	(	(	PUNCT
ap-2293	44	8	0.825	0.825	NUM
ap-2293	44	9	+	+	CCONJ
ap-2293	44	10	0.387(ra	0.387(ra	NUM
ap-2293	44	11	f(pr))1/6)2	f(pr))1/6)2	NUM
ap-2293	44	12	,	,	PUNCT
ap-2293	44	13	(	(	PUNCT
ap-2293	44	14	2	2	X
ap-2293	44	15	)	)	PUNCT
ap-2293	44	16	f(pr	f(pr	NOUN
ap-2293	44	17	)	)	PUNCT
ap-2293	44	18	=	=	PUNCT
ap-2293	44	19	(	(	PUNCT
ap-2293	44	20	1	1	NUM
ap-2293	44	21	+	+	CCONJ
ap-2293	44	22	(	(	PUNCT
ap-2293	44	23	0.492	0.492	NUM
ap-2293	44	24	/	/	SYM
ap-2293	44	25	pr)9/16)−16/9	pr)9/16)−16/9	PROPN
ap-2293	44	26	.	.	PUNCT
ap-2293	45	1	(	(	PUNCT
ap-2293	45	2	3	3	X
ap-2293	45	3	)	)	PUNCT
ap-2293	45	4	in	in	ADP
ap-2293	45	5	order	order	NOUN
ap-2293	45	6	to	to	PART
ap-2293	45	7	calculate	calculate	VERB
ap-2293	45	8	the	the	DET
ap-2293	45	9	prandtl	prandtl	NOUN
ap-2293	45	10	(	(	PUNCT
ap-2293	45	11	pr	pr	NOUN
ap-2293	45	12	)	)	PUNCT
ap-2293	45	13	and	and	CCONJ
ap-2293	45	14	rayleigh	rayleigh	PROPN
ap-2293	45	15	(	(	PUNCT
ap-2293	45	16	ra	ra	NOUN
ap-2293	45	17	)	)	PUNCT
ap-2293	45	18	similarity	similarity	NOUN
ap-2293	45	19	criteria	criterion	NOUN
ap-2293	45	20	,	,	PUNCT
ap-2293	45	21	it	it	PRON
ap-2293	45	22	is	be	AUX
ap-2293	45	23	necessary	necessary	ADJ
ap-2293	45	24	to	to	PART
ap-2293	45	25	know	know	VERB
ap-2293	45	26	the	the	DET
ap-2293	45	27	material	material	NOUN
ap-2293	45	28	characteristics	characteristic	NOUN
ap-2293	45	29	of	of	ADP
ap-2293	45	30	the	the	DET
ap-2293	45	31	stum	stum	NOUN
ap-2293	45	32	,	,	PUNCT
ap-2293	45	33	which	which	PRON
ap-2293	45	34	consists	consist	VERB
ap-2293	45	35	,	,	PUNCT
ap-2293	45	36	ideally	ideally	ADV
ap-2293	45	37	,	,	PUNCT
ap-2293	45	38	of	of	ADP
ap-2293	45	39	a	a	DET
ap-2293	45	40	mixture	mixture	NOUN
ap-2293	45	41	of	of	ADP
ap-2293	45	42	water	water	NOUN
ap-2293	45	43	and	and	CCONJ
ap-2293	45	44	sugar	sugar	NOUN
ap-2293	45	45	with	with	ADP
ap-2293	45	46	an	an	DET
ap-2293	45	47	amount	amount	NOUN
ap-2293	45	48	of	of	ADP
ap-2293	45	49	400	400	NUM
ap-2293	45	50	g	g	NOUN
ap-2293	45	51	of	of	ADP
ap-2293	45	52	sugar	sugar	NOUN
ap-2293	45	53	per	per	ADP
ap-2293	45	54	1	1	NUM
ap-2293	45	55	litre	litre	NOUN
ap-2293	45	56	of	of	ADP
ap-2293	45	57	the	the	DET
ap-2293	45	58	solution	solution	NOUN
ap-2293	45	59	[	[	X
ap-2293	45	60	2	2	NUM
ap-2293	45	61	]	]	PUNCT
ap-2293	45	62	.	.	PUNCT
ap-2293	46	1	the	the	DET
ap-2293	46	2	volume	volume	NOUN
ap-2293	46	3	concentration	concentration	NOUN
ap-2293	46	4	c	c	NOUN
ap-2293	46	5	,	,	PUNCT
ap-2293	46	6	which	which	PRON
ap-2293	46	7	is	be	AUX
ap-2293	46	8	calculated	calculate	VERB
ap-2293	46	9	as	as	ADP
ap-2293	46	10	the	the	DET
ap-2293	46	11	141	141	NUM
ap-2293	46	12	t.	t.	NOUN
ap-2293	46	13	brestovič	brestovič	PROPN
ap-2293	46	14	,	,	PUNCT
ap-2293	46	15	m.	m.	NOUN
ap-2293	46	16	čarnogurská	čarnogurská	NOUN
ap-2293	46	17	,	,	PUNCT
ap-2293	46	18	m.	m.	NOUN
ap-2293	46	19	přihoda	přihoda	NOUN
ap-2293	46	20	,	,	PUNCT
ap-2293	46	21	m.	m.	PROPN
ap-2293	46	22	kubík	kubík	PROPN
ap-2293	46	23	acta	acta	PROPN
ap-2293	46	24	polytechnica	polytechnica	PROPN
ap-2293	46	25	figure	figure	NOUN
ap-2293	46	26	2	2	NUM
ap-2293	46	27	.	.	PUNCT
ap-2293	46	28	dependence	dependence	NOUN
ap-2293	46	29	of	of	ADP
ap-2293	46	30	the	the	DET
ap-2293	46	31	volume	volume	NOUN
ap-2293	46	32	expansion	expansion	NOUN
ap-2293	46	33	coefficient	coefficient	NOUN
ap-2293	46	34	of	of	ADP
ap-2293	46	35	the	the	DET
ap-2293	46	36	30	30	NUM
ap-2293	46	37	%	%	NOUN
ap-2293	46	38	sugar	sugar	NOUN
ap-2293	46	39	solution	solution	NOUN
ap-2293	46	40	on	on	ADP
ap-2293	46	41	temperature	temperature	NOUN
ap-2293	46	42	.	.	PUNCT
ap-2293	47	1	figure	figure	NOUN
ap-2293	47	2	3	3	NUM
ap-2293	47	3	.	.	PUNCT
ap-2293	47	4	temperature	temperature	NOUN
ap-2293	47	5	field	field	NOUN
ap-2293	47	6	at	at	ADP
ap-2293	47	7	∆tn	∆tn	PROPN
ap-2293	47	8	=	=	SYM
ap-2293	48	1	−8	−8	X
ap-2293	48	2	°	°	NOUN
ap-2293	48	3	c	c	NOUN
ap-2293	48	4	.	.	PUNCT
ap-2293	49	1	ratio	ratio	NOUN
ap-2293	49	2	of	of	ADP
ap-2293	49	3	the	the	DET
ap-2293	49	4	sugar	sugar	NOUN
ap-2293	49	5	weight	weight	NOUN
ap-2293	49	6	to	to	ADP
ap-2293	49	7	the	the	DET
ap-2293	49	8	total	total	ADJ
ap-2293	49	9	solution	solution	NOUN
ap-2293	49	10	weight	weight	NOUN
ap-2293	49	11	,	,	PUNCT
ap-2293	49	12	is	be	AUX
ap-2293	49	13	about	about	ADV
ap-2293	49	14	30	30	NUM
ap-2293	49	15	%	%	NOUN
ap-2293	49	16	.	.	PUNCT
ap-2293	50	1	the	the	DET
ap-2293	50	2	dynamic	dynamic	ADJ
ap-2293	50	3	viscosity	viscosity	NOUN
ap-2293	50	4	of	of	ADP
ap-2293	50	5	this	this	DET
ap-2293	50	6	solution	solution	NOUN
ap-2293	50	7	has	have	VERB
ap-2293	50	8	the	the	DET
ap-2293	50	9	value	value	NOUN
ap-2293	50	10	of	of	ADP
ap-2293	50	11	3.188	3.188	NUM
ap-2293	50	12	·	·	SYM
ap-2293	50	13	10−3	10−3	NUM
ap-2293	50	14	pa	pa	NOUN
ap-2293	50	15	s	s	PROPN
ap-2293	50	16	at	at	ADP
ap-2293	50	17	the	the	DET
ap-2293	50	18	temperature	temperature	NOUN
ap-2293	50	19	of	of	ADP
ap-2293	50	20	20	20	NUM
ap-2293	50	21	°	°	NOUN
ap-2293	50	22	c	c	NOUN
ap-2293	50	23	and	and	CCONJ
ap-2293	50	24	2.5	2.5	NUM
ap-2293	50	25	·	·	SYM
ap-2293	50	26	10−3	10−3	NUM
ap-2293	50	27	pa	pa	NOUN
ap-2293	50	28	s	s	PROPN
ap-2293	50	29	at	at	ADP
ap-2293	50	30	the	the	DET
ap-2293	50	31	temperature	temperature	NOUN
ap-2293	50	32	of	of	ADP
ap-2293	50	33	30	30	NUM
ap-2293	50	34	°	°	NOUN
ap-2293	50	35	c	c	NOUN
ap-2293	50	36	.	.	PUNCT
ap-2293	51	1	the	the	DET
ap-2293	51	2	temperature	temperature	NOUN
ap-2293	51	3	dependence	dependence	NOUN
ap-2293	51	4	of	of	ADP
ap-2293	51	5	the	the	DET
ap-2293	51	6	dynamic	dynamic	ADJ
ap-2293	51	7	viscosity	viscosity	NOUN
ap-2293	51	8	of	of	ADP
ap-2293	51	9	liquids	liquid	NOUN
ap-2293	51	10	may	may	AUX
ap-2293	51	11	be	be	AUX
ap-2293	51	12	described	describe	VERB
ap-2293	51	13	[	[	X
ap-2293	51	14	2	2	NUM
ap-2293	51	15	]	]	PUNCT
ap-2293	51	16	by	by	ADP
ap-2293	51	17	exponential	exponential	ADJ
ap-2293	51	18	dependence	dependence	NOUN
ap-2293	51	19	η	η	PROPN
ap-2293	51	20	=	=	SYM
ap-2293	51	21	aeb	aeb	PROPN
ap-2293	51	22	/	/	SYM
ap-2293	51	23	t	t	PROPN
ap-2293	51	24	.	.	PUNCT
ap-2293	52	1	(	(	PUNCT
ap-2293	52	2	4	4	X
ap-2293	52	3	)	)	PUNCT
ap-2293	52	4	the	the	DET
ap-2293	52	5	value	value	NOUN
ap-2293	52	6	of	of	ADP
ap-2293	52	7	the	the	DET
ap-2293	52	8	following	following	ADJ
ap-2293	52	9	constants	constant	NOUN
ap-2293	52	10	,	,	PUNCT
ap-2293	52	11	a	a	DET
ap-2293	52	12	=	=	SYM
ap-2293	52	13	2	2	NUM
ap-2293	52	14	·	·	SYM
ap-2293	52	15	10−6	10−6	NUM
ap-2293	52	16	pa	pa	PROPN
ap-2293	52	17	s	s	PROPN
ap-2293	52	18	and	and	CCONJ
ap-2293	52	19	b	b	NOUN
ap-2293	52	20	=	=	SYM
ap-2293	52	21	2160.4k	2160.4k	NUM
ap-2293	52	22	,	,	PUNCT
ap-2293	52	23	has	have	AUX
ap-2293	52	24	been	be	AUX
ap-2293	52	25	obtained	obtain	VERB
ap-2293	52	26	thanks	thank	NOUN
ap-2293	52	27	to	to	ADP
ap-2293	52	28	a	a	DET
ap-2293	52	29	logarithmic	logarithmic	ADJ
ap-2293	52	30	calculation	calculation	NOUN
ap-2293	52	31	of	of	ADP
ap-2293	52	32	(	(	PUNCT
ap-2293	52	33	4	4	NUM
ap-2293	52	34	)	)	PUNCT
ap-2293	52	35	,	,	PUNCT
ap-2293	52	36	and	and	CCONJ
ap-2293	52	37	by	by	ADP
ap-2293	52	38	solving	solve	VERB
ap-2293	52	39	a	a	DET
ap-2293	52	40	set	set	NOUN
ap-2293	52	41	of	of	ADP
ap-2293	52	42	two	two	NUM
ap-2293	52	43	linear	linear	ADJ
ap-2293	52	44	equations	equation	NOUN
ap-2293	52	45	.	.	PUNCT
ap-2293	53	1	the	the	DET
ap-2293	53	2	thermal	thermal	ADJ
ap-2293	53	3	conductivity	conductivity	NOUN
ap-2293	53	4	of	of	ADP
ap-2293	53	5	the	the	DET
ap-2293	53	6	solution	solution	NOUN
ap-2293	53	7	is	be	AUX
ap-2293	53	8	linearly	linearly	ADV
ap-2293	53	9	dependent	dependent	ADJ
ap-2293	53	10	on	on	ADP
ap-2293	53	11	the	the	DET
ap-2293	53	12	concentration	concentration	NOUN
ap-2293	53	13	c	c	NOUN
ap-2293	53	14	(	(	PUNCT
ap-2293	53	15	kg	kg	PROPN
ap-2293	53	16	/	/	SYM
ap-2293	53	17	kg	kg	NOUN
ap-2293	53	18	)	)	PUNCT
ap-2293	54	1	[	[	X
ap-2293	54	2	3	3	NUM
ap-2293	54	3	]	]	PUNCT
ap-2293	54	4	:	:	PUNCT
ap-2293	55	1	λ	λ	X
ap-2293	55	2	=	=	SYM
ap-2293	55	3	dc+	dc+	PROPN
ap-2293	55	4	e.	e.	PROPN
ap-2293	55	5	(	(	PUNCT
ap-2293	55	6	5	5	NUM
ap-2293	55	7	)	)	PUNCT
ap-2293	55	8	the	the	DET
ap-2293	55	9	variables	variable	NOUN
ap-2293	55	10	d	d	PROPN
ap-2293	55	11	and	and	CCONJ
ap-2293	55	12	e	e	NOUN
ap-2293	55	13	are	be	AUX
ap-2293	55	14	functionally	functionally	ADV
ap-2293	55	15	dependent	dependent	ADJ
ap-2293	55	16	on	on	ADP
ap-2293	55	17	figure	figure	NOUN
ap-2293	55	18	4	4	NUM
ap-2293	55	19	.	.	PUNCT
ap-2293	55	20	heat	heat	NOUN
ap-2293	55	21	flux	flux	NOUN
ap-2293	55	22	at	at	ADP
ap-2293	55	23	∆tn	∆tn	PROPN
ap-2293	55	24	=	=	SYM
ap-2293	56	1	−8	−8	X
ap-2293	57	1	°	°	NOUN
ap-2293	57	2	c	c	X
ap-2293	57	3	.	.	PUNCT
ap-2293	58	1	the	the	DET
ap-2293	58	2	temperature	temperature	NOUN
ap-2293	58	3	of	of	ADP
ap-2293	58	4	the	the	DET
ap-2293	58	5	solution	solution	NOUN
ap-2293	58	6	,	,	PUNCT
ap-2293	58	7	in	in	ADP
ap-2293	58	8	accordance	accordance	NOUN
ap-2293	58	9	with	with	ADP
ap-2293	58	10	d	d	PROPN
ap-2293	58	11	=	=	SYM
ap-2293	58	12	5.466	5.466	NUM
ap-2293	58	13	·	·	PUNCT
ap-2293	58	14	10−8t2	10−8t2	NUM
ap-2293	58	15	−	−	NOUN
ap-2293	58	16	1.176	1.176	NUM
ap-2293	58	17	·	·	PUNCT
ap-2293	58	18	10−5t−	10−5t−	NUM
ap-2293	58	19	3.024	3.024	NUM
ap-2293	58	20	·	·	SYM
ap-2293	58	21	10−3	10−3	NUM
ap-2293	58	22	,	,	PUNCT
ap-2293	58	23	(	(	PUNCT
ap-2293	58	24	6	6	NUM
ap-2293	58	25	)	)	PUNCT
ap-2293	58	26	e	e	NOUN
ap-2293	58	27	=	=	PUNCT
ap-2293	58	28	−7.847	−7.847	PROPN
ap-2293	58	29	·	·	PUNCT
ap-2293	58	30	10−6t2	10−6t2	NUM
ap-2293	59	1	+	+	CCONJ
ap-2293	59	2	1.976	1.976	NUM
ap-2293	59	3	·	·	PUNCT
ap-2293	59	4	10−3t+	10−3t+	NUM
ap-2293	59	5	0.563	0.563	NUM
ap-2293	59	6	.	.	PUNCT
ap-2293	60	1	(	(	PUNCT
ap-2293	60	2	7	7	X
ap-2293	60	3	)	)	PUNCT
ap-2293	60	4	the	the	DET
ap-2293	60	5	thermal	thermal	ADJ
ap-2293	60	6	capacity	capacity	NOUN
ap-2293	60	7	of	of	ADP
ap-2293	60	8	the	the	DET
ap-2293	60	9	solution	solution	NOUN
ap-2293	60	10	in	in	ADP
ap-2293	60	11	the	the	DET
ap-2293	60	12	range	range	NOUN
ap-2293	60	13	of	of	ADP
ap-2293	60	14	0	0	NUM
ap-2293	60	15	to	to	PART
ap-2293	60	16	90	90	NUM
ap-2293	60	17	°	°	NOUN
ap-2293	60	18	c	c	NOUN
ap-2293	60	19	is	be	AUX
ap-2293	60	20	shown	show	VERB
ap-2293	60	21	in	in	ADP
ap-2293	60	22	figure	figure	NOUN
ap-2293	60	23	1	1	NUM
ap-2293	60	24	[	[	X
ap-2293	60	25	4	4	NUM
ap-2293	60	26	]	]	PUNCT
ap-2293	60	27	.	.	PUNCT
ap-2293	61	1	the	the	DET
ap-2293	61	2	volume	volume	NOUN
ap-2293	61	3	expansion	expansion	NOUN
ap-2293	61	4	of	of	ADP
ap-2293	61	5	the	the	DET
ap-2293	61	6	sugar	sugar	NOUN
ap-2293	61	7	solution	solution	NOUN
ap-2293	61	8	may	may	AUX
ap-2293	61	9	be	be	AUX
ap-2293	61	10	defined	define	VERB
ap-2293	61	11	from	from	ADP
ap-2293	61	12	the	the	DET
ap-2293	61	13	known	know	VERB
ap-2293	61	14	density	density	NOUN
ap-2293	61	15	dependence	dependence	NOUN
ap-2293	61	16	on	on	ADP
ap-2293	61	17	temperature	temperature	NOUN
ap-2293	61	18	.	.	PUNCT
ap-2293	62	1	it	it	PRON
ap-2293	62	2	is	be	AUX
ap-2293	62	3	determined	determine	VERB
ap-2293	62	4	by	by	ADP
ap-2293	62	5	solving	solve	VERB
ap-2293	62	6	the	the	DET
ap-2293	62	7	following	follow	VERB
ap-2293	62	8	equation	equation	NOUN
ap-2293	62	9	numerically	numerically	ADV
ap-2293	62	10	:	:	PUNCT
ap-2293	63	1	β	β	X
ap-2293	63	2	=	=	PUNCT
ap-2293	63	3	−1	−1	NOUN
ap-2293	63	4	%	%	NOUN
ap-2293	63	5	(	(	PUNCT
ap-2293	63	6	∂%	∂%	NOUN
ap-2293	63	7	∂t	∂t	PROPN
ap-2293	63	8	)	)	PUNCT
ap-2293	63	9	p	p	NOUN
ap-2293	63	10	.	.	PUNCT
ap-2293	64	1	(	(	PUNCT
ap-2293	64	2	8)	8)	NUM
ap-2293	64	3	the	the	DET
ap-2293	64	4	dependence	dependence	NOUN
ap-2293	64	5	of	of	ADP
ap-2293	64	6	the	the	DET
ap-2293	64	7	coefficient	coefficient	NOUN
ap-2293	64	8	β	β	PROPN
ap-2293	64	9	of	of	ADP
ap-2293	64	10	the	the	DET
ap-2293	64	11	used	use	VERB
ap-2293	64	12	solution	solution	NOUN
ap-2293	64	13	on	on	ADP
ap-2293	64	14	temperature	temperature	NOUN
ap-2293	64	15	in	in	ADP
ap-2293	64	16	the	the	DET
ap-2293	64	17	range	range	NOUN
ap-2293	64	18	from	from	ADP
ap-2293	64	19	0	0	NUM
ap-2293	64	20	to	to	ADP
ap-2293	64	21	70	70	NUM
ap-2293	64	22	°	°	NOUN
ap-2293	64	23	c	c	NOUN
ap-2293	64	24	is	be	AUX
ap-2293	64	25	plotted	plot	VERB
ap-2293	64	26	in	in	ADP
ap-2293	64	27	figure	figure	NOUN
ap-2293	64	28	2	2	NUM
ap-2293	64	29	.	.	NOUN
ap-2293	64	30	142	142	NUM
ap-2293	64	31	vol	vol	NOUN
ap-2293	64	32	.	.	PUNCT
ap-2293	65	1	55	55	NUM
ap-2293	65	2	no	no	NOUN
ap-2293	65	3	.	.	PUNCT
ap-2293	66	1	3/2015	3/2015	NUM
ap-2293	66	2	simulation	simulation	NOUN
ap-2293	66	3	of	of	ADP
ap-2293	66	4	heat	heat	NOUN
ap-2293	66	5	transport	transport	NOUN
ap-2293	66	6	figure	figure	NOUN
ap-2293	66	7	5	5	NUM
ap-2293	66	8	.	.	PUNCT
ap-2293	67	1	dependence	dependence	NOUN
ap-2293	67	2	of	of	ADP
ap-2293	67	3	the	the	DET
ap-2293	67	4	cooling	cool	VERB
ap-2293	67	5	performance	performance	NOUN
ap-2293	67	6	on	on	ADP
ap-2293	67	7	the	the	DET
ap-2293	67	8	temperatures	temperature	NOUN
ap-2293	67	9	of	of	ADP
ap-2293	67	10	the	the	DET
ap-2293	67	11	cooling	cool	VERB
ap-2293	67	12	mixture	mixture	NOUN
ap-2293	67	13	and	and	CCONJ
ap-2293	67	14	of	of	ADP
ap-2293	67	15	the	the	DET
ap-2293	67	16	stum	stum	NOUN
ap-2293	67	17	.	.	PUNCT
ap-2293	68	1	in	in	ADP
ap-2293	68	2	the	the	DET
ap-2293	68	3	t1400	t1400	NOUN
ap-2293	68	4	and	and	CCONJ
ap-2293	68	5	t930	t930	NUM
ap-2293	68	6	tanks	tank	NOUN
ap-2293	68	7	,	,	PUNCT
ap-2293	68	8	cooling	cool	VERB
ap-2293	68	9	panels	panel	NOUN
ap-2293	68	10	with	with	ADP
ap-2293	68	11	similar	similar	ADJ
ap-2293	68	12	channel	channel	NOUN
ap-2293	68	13	arrangements	arrangement	NOUN
ap-2293	68	14	are	be	AUX
ap-2293	68	15	used	use	VERB
ap-2293	68	16	for	for	ADP
ap-2293	68	17	the	the	DET
ap-2293	68	18	cooling	cool	VERB
ap-2293	68	19	mixture	mixture	NOUN
ap-2293	68	20	transport	transport	NOUN
ap-2293	68	21	,	,	PUNCT
ap-2293	68	22	but	but	CCONJ
ap-2293	68	23	the	the	DET
ap-2293	68	24	panel	panel	NOUN
ap-2293	68	25	of	of	ADP
ap-2293	68	26	the	the	DET
ap-2293	68	27	t930	t930	PROPN
ap-2293	68	28	tank	tank	NOUN
ap-2293	68	29	has	have	VERB
ap-2293	68	30	half	half	DET
ap-2293	68	31	the	the	DET
ap-2293	68	32	total	total	ADJ
ap-2293	68	33	dimension	dimension	NOUN
ap-2293	68	34	and	and	CCONJ
ap-2293	68	35	channel	channel	NOUN
ap-2293	68	36	length	length	NOUN
ap-2293	68	37	compared	compare	VERB
ap-2293	68	38	to	to	ADP
ap-2293	68	39	the	the	DET
ap-2293	68	40	t1400	t1400	PROPN
ap-2293	68	41	tank	tank	NOUN
ap-2293	68	42	panel	panel	NOUN
ap-2293	68	43	.	.	PUNCT
ap-2293	69	1	taking	take	VERB
ap-2293	69	2	these	these	DET
ap-2293	69	3	facts	fact	NOUN
ap-2293	69	4	into	into	ADP
ap-2293	69	5	account	account	NOUN
ap-2293	69	6	,	,	PUNCT
ap-2293	69	7	the	the	DET
ap-2293	69	8	total	total	ADJ
ap-2293	69	9	cooling	cool	VERB
ap-2293	69	10	performance	performance	NOUN
ap-2293	69	11	of	of	ADP
ap-2293	69	12	24.5	24.5	NUM
ap-2293	69	13	cooling	cool	VERB
ap-2293	69	14	panels	panel	NOUN
ap-2293	69	15	is	be	AUX
ap-2293	69	16	considered	consider	VERB
ap-2293	69	17	(	(	PUNCT
ap-2293	69	18	22	22	NUM
ap-2293	69	19	panels	panel	NOUN
ap-2293	69	20	of	of	ADP
ap-2293	69	21	the	the	DET
ap-2293	69	22	t1400	t1400	NOUN
ap-2293	69	23	type	type	NOUN
ap-2293	69	24	+	+	CCONJ
ap-2293	69	25	0.5	0.5	NUM
ap-2293	69	26	×	×	NOUN
ap-2293	69	27	5	5	NUM
ap-2293	69	28	panels	panel	NOUN
ap-2293	69	29	of	of	ADP
ap-2293	69	30	the	the	DET
ap-2293	69	31	t930	t930	PROPN
ap-2293	69	32	type	type	NOUN
ap-2293	69	33	)	)	PUNCT
ap-2293	69	34	.	.	PUNCT
ap-2293	70	1	the	the	DET
ap-2293	70	2	temperature	temperature	NOUN
ap-2293	70	3	field	field	NOUN
ap-2293	70	4	of	of	ADP
ap-2293	70	5	the	the	DET
ap-2293	70	6	cooling	cool	VERB
ap-2293	70	7	panel	panel	NOUN
ap-2293	70	8	in	in	ADP
ap-2293	70	9	the	the	DET
ap-2293	70	10	axis	axis	NOUN
ap-2293	70	11	section	section	NOUN
ap-2293	70	12	is	be	AUX
ap-2293	70	13	seen	see	VERB
ap-2293	70	14	in	in	ADP
ap-2293	70	15	figure	figure	NOUN
ap-2293	70	16	3	3	NUM
ap-2293	70	17	at	at	ADP
ap-2293	70	18	∆tn	∆tn	PROPN
ap-2293	70	19	=	=	SYM
ap-2293	71	1	−8	−8	PROPN
ap-2293	71	2	°	°	NOUN
ap-2293	71	3	c	c	VERB
ap-2293	71	4	.	.	PUNCT
ap-2293	72	1	the	the	DET
ap-2293	72	2	distribution	distribution	NOUN
ap-2293	72	3	of	of	ADP
ap-2293	72	4	heat	heat	NOUN
ap-2293	72	5	flux	flux	NOUN
ap-2293	72	6	on	on	ADP
ap-2293	72	7	the	the	DET
ap-2293	72	8	surface	surface	NOUN
ap-2293	72	9	of	of	ADP
ap-2293	72	10	the	the	DET
ap-2293	72	11	panel	panel	NOUN
ap-2293	72	12	at	at	ADP
ap-2293	72	13	above	above	ADV
ap-2293	72	14	specified	specify	VERB
ap-2293	72	15	boundary	boundary	ADJ
ap-2293	72	16	conditions	condition	NOUN
ap-2293	72	17	is	be	AUX
ap-2293	72	18	shown	show	VERB
ap-2293	72	19	in	in	ADP
ap-2293	72	20	figure	figure	NOUN
ap-2293	72	21	4	4	NUM
ap-2293	72	22	.	.	PUNCT
ap-2293	73	1	the	the	DET
ap-2293	73	2	course	course	NOUN
ap-2293	73	3	of	of	ADP
ap-2293	73	4	another	another	DET
ap-2293	73	5	investigated	investigate	VERB
ap-2293	73	6	dependence	dependence	NOUN
ap-2293	73	7	of	of	ADP
ap-2293	73	8	the	the	DET
ap-2293	73	9	cooling	cool	VERB
ap-2293	73	10	performance	performance	NOUN
ap-2293	73	11	of	of	ADP
ap-2293	73	12	all	all	DET
ap-2293	73	13	the	the	DET
ap-2293	73	14	panels	panel	NOUN
ap-2293	73	15	on	on	ADP
ap-2293	73	16	the	the	DET
ap-2293	73	17	temperature	temperature	NOUN
ap-2293	73	18	difference	difference	NOUN
ap-2293	73	19	of	of	ADP
ap-2293	73	20	the	the	DET
ap-2293	73	21	cooling	cool	VERB
ap-2293	73	22	mixture	mixture	NOUN
ap-2293	73	23	and	and	CCONJ
ap-2293	73	24	the	the	DET
ap-2293	73	25	stum	stum	NOUN
ap-2293	73	26	is	be	AUX
ap-2293	73	27	shown	show	VERB
ap-2293	73	28	in	in	ADP
ap-2293	73	29	figure	figure	NOUN
ap-2293	73	30	5	5	NUM
ap-2293	73	31	.	.	PUNCT
ap-2293	74	1	the	the	DET
ap-2293	74	2	regression	regression	NOUN
ap-2293	74	3	line	line	NOUN
ap-2293	74	4	describing	describe	VERB
ap-2293	74	5	the	the	DET
ap-2293	74	6	cooling	cool	VERB
ap-2293	74	7	performance	performance	NOUN
ap-2293	74	8	must	must	AUX
ap-2293	74	9	cross	cross	VERB
ap-2293	74	10	zero	zero	NUM
ap-2293	74	11	because	because	SCONJ
ap-2293	74	12	if	if	SCONJ
ap-2293	74	13	the	the	DET
ap-2293	74	14	mixture	mixture	NOUN
ap-2293	74	15	and	and	CCONJ
ap-2293	74	16	the	the	DET
ap-2293	74	17	stum	stum	NOUN
ap-2293	74	18	have	have	VERB
ap-2293	74	19	the	the	DET
ap-2293	74	20	same	same	ADJ
ap-2293	74	21	temperature	temperature	NOUN
ap-2293	74	22	,	,	PUNCT
ap-2293	74	23	the	the	DET
ap-2293	74	24	cooling	cool	VERB
ap-2293	74	25	performance	performance	NOUN
ap-2293	74	26	is	be	AUX
ap-2293	74	27	zero	zero	NUM
ap-2293	74	28	.	.	PUNCT
ap-2293	75	1	the	the	DET
ap-2293	75	2	regression	regression	NOUN
ap-2293	75	3	dependence	dependence	NOUN
ap-2293	75	4	equation	equation	NOUN
ap-2293	75	5	for	for	ADP
ap-2293	75	6	a	a	DET
ap-2293	75	7	performance	performance	NOUN
ap-2293	75	8	ranging	range	VERB
ap-2293	75	9	from	from	ADP
ap-2293	75	10	0	0	NUM
ap-2293	75	11	to	to	PART
ap-2293	75	12	30	30	NUM
ap-2293	75	13	kw	kw	NOUN
ap-2293	75	14	is	be	AUX
ap-2293	75	15	in	in	ADP
ap-2293	75	16	the	the	DET
ap-2293	75	17	form	form	NOUN
ap-2293	75	18	of	of	ADP
ap-2293	75	19	pch	pch	ADJ
ap-2293	75	20	=	=	PUNCT
ap-2293	75	21	d∆tn	d∆tn	NOUN
ap-2293	75	22	=	=	PUNCT
ap-2293	75	23	−2000∆tn	−2000∆tn	NOUN
ap-2293	75	24	.	.	PUNCT
ap-2293	76	1	(	(	PUNCT
ap-2293	76	2	9	9	X
ap-2293	76	3	)	)	PUNCT
ap-2293	76	4	this	this	DET
ap-2293	76	5	equation	equation	NOUN
ap-2293	76	6	shows	show	VERB
ap-2293	76	7	that	that	SCONJ
ap-2293	76	8	in	in	ADP
ap-2293	76	9	order	order	NOUN
ap-2293	76	10	to	to	PART
ap-2293	76	11	achieve	achieve	VERB
ap-2293	76	12	a	a	DET
ap-2293	76	13	cooling	cool	VERB
ap-2293	76	14	performance	performance	NOUN
ap-2293	76	15	of	of	ADP
ap-2293	76	16	27.5	27.5	NUM
ap-2293	76	17	kw	kw	NOUN
ap-2293	76	18	,	,	PUNCT
ap-2293	76	19	it	it	PRON
ap-2293	76	20	is	be	AUX
ap-2293	76	21	necessary	necessary	ADJ
ap-2293	76	22	to	to	PART
ap-2293	76	23	bring	bring	VERB
ap-2293	76	24	the	the	DET
ap-2293	76	25	cooling	cool	VERB
ap-2293	76	26	mixture	mixture	NOUN
ap-2293	76	27	to	to	ADP
ap-2293	76	28	a	a	DET
ap-2293	76	29	temperature	temperature	NOUN
ap-2293	76	30	which	which	PRON
ap-2293	76	31	is	be	AUX
ap-2293	76	32	lower	low	ADJ
ap-2293	76	33	by	by	ADP
ap-2293	76	34	13.75	13.75	NUM
ap-2293	76	35	°	°	ADP
ap-2293	76	36	c	c	NOUN
ap-2293	76	37	than	than	ADP
ap-2293	76	38	the	the	DET
ap-2293	76	39	temperature	temperature	NOUN
ap-2293	76	40	of	of	ADP
ap-2293	76	41	the	the	DET
ap-2293	76	42	stum	stum	NOUN
ap-2293	76	43	(	(	PUNCT
ap-2293	76	44	at	at	ADP
ap-2293	76	45	the	the	DET
ap-2293	76	46	stum	stum	NOUN
ap-2293	76	47	temperature	temperature	NOUN
ap-2293	76	48	of	of	ADP
ap-2293	76	49	0	0	NUM
ap-2293	76	50	°	°	NOUN
ap-2293	76	51	c	c	NOUN
ap-2293	76	52	,	,	PUNCT
ap-2293	76	53	the	the	DET
ap-2293	76	54	cooling	cool	VERB
ap-2293	76	55	mixture	mixture	NOUN
ap-2293	76	56	will	will	AUX
ap-2293	76	57	have	have	VERB
ap-2293	76	58	the	the	DET
ap-2293	76	59	temperature	temperature	NOUN
ap-2293	76	60	of	of	ADP
ap-2293	76	61	-13.75	-13.75	PROPN
ap-2293	76	62	°	°	PROPN
ap-2293	76	63	c	c	PROPN
ap-2293	76	64	)	)	PUNCT
ap-2293	76	65	.	.	PUNCT
ap-2293	77	1	3	3	X
ap-2293	77	2	.	.	X
ap-2293	78	1	jn30	jn30	ADJ
ap-2293	78	2	device	device	NOUN
ap-2293	78	3	cooling	cool	VERB
ap-2293	78	4	capacity	capacity	NOUN
ap-2293	78	5	calculation	calculation	NOUN
ap-2293	78	6	the	the	DET
ap-2293	78	7	cooling	cool	VERB
ap-2293	78	8	device	device	NOUN
ap-2293	78	9	takes	take	VERB
ap-2293	78	10	off	off	ADP
ap-2293	78	11	the	the	DET
ap-2293	78	12	thermal	thermal	ADJ
ap-2293	78	13	output	output	NOUN
ap-2293	78	14	(	(	PUNCT
ap-2293	78	15	pch	pch	PROPN
ap-2293	78	16	)	)	PUNCT
ap-2293	78	17	from	from	ADP
ap-2293	78	18	the	the	DET
ap-2293	78	19	tank	tank	NOUN
ap-2293	78	20	,	,	PUNCT
ap-2293	78	21	including	include	VERB
ap-2293	78	22	the	the	DET
ap-2293	78	23	heat	heat	NOUN
ap-2293	78	24	exchange	exchange	NOUN
ap-2293	78	25	with	with	ADP
ap-2293	78	26	the	the	DET
ap-2293	78	27	environment	environment	NOUN
ap-2293	78	28	(	(	PUNCT
ap-2293	78	29	pok	pok	NOUN
ap-2293	78	30	)	)	PUNCT
ap-2293	78	31	,	,	PUNCT
ap-2293	78	32	and	and	CCONJ
ap-2293	78	33	at	at	ADP
ap-2293	78	34	the	the	DET
ap-2293	78	35	same	same	ADJ
ap-2293	78	36	time	time	NOUN
ap-2293	78	37	the	the	DET
ap-2293	78	38	heat	heat	NOUN
ap-2293	78	39	taken	take	VERB
ap-2293	78	40	from	from	ADP
ap-2293	78	41	the	the	DET
ap-2293	78	42	tank	tank	NOUN
ap-2293	78	43	material	material	NOUN
ap-2293	78	44	and	and	CCONJ
ap-2293	78	45	from	from	ADP
ap-2293	78	46	the	the	DET
ap-2293	78	47	stum	stum	NOUN
ap-2293	78	48	(	(	PUNCT
ap-2293	78	49	pak	pak	NOUN
ap-2293	78	50	)	)	PUNCT
ap-2293	78	51	–	–	PUNCT
ap-2293	78	52	figure	figure	NOUN
ap-2293	78	53	6	6	NUM
ap-2293	78	54	.	.	PUNCT
ap-2293	79	1	figure	figure	NOUN
ap-2293	79	2	6	6	NUM
ap-2293	79	3	.	.	PUNCT
ap-2293	79	4	stum	stum	NOUN
ap-2293	79	5	tank	tank	NOUN
ap-2293	79	6	scheme	scheme	NOUN
ap-2293	79	7	with	with	ADP
ap-2293	79	8	thermal	thermal	ADJ
ap-2293	79	9	flows	flow	NOUN
ap-2293	79	10	.	.	PUNCT
ap-2293	80	1	the	the	DET
ap-2293	80	2	thermal	thermal	ADJ
ap-2293	80	3	balance	balance	NOUN
ap-2293	80	4	of	of	ADP
ap-2293	80	5	this	this	DET
ap-2293	80	6	system	system	NOUN
ap-2293	80	7	may	may	AUX
ap-2293	80	8	be	be	AUX
ap-2293	80	9	written	write	VERB
ap-2293	80	10	in	in	ADP
ap-2293	80	11	a	a	DET
ap-2293	80	12	time	time	NOUN
ap-2293	80	13	unit	unit	NOUN
ap-2293	80	14	as	as	ADP
ap-2293	80	15	the	the	DET
ap-2293	80	16	following	follow	VERB
ap-2293	80	17	equation	equation	NOUN
ap-2293	80	18	:	:	PUNCT
ap-2293	80	19	pok	pok	NOUN
ap-2293	80	20	−	−	PROPN
ap-2293	80	21	pch	pch	ADJ
ap-2293	80	22	=	=	X
ap-2293	80	23	pak	pak	NOUN
ap-2293	80	24	(	(	PUNCT
ap-2293	80	25	10	10	NUM
ap-2293	80	26	)	)	PUNCT
ap-2293	80	27	the	the	DET
ap-2293	80	28	thermal	thermal	ADJ
ap-2293	80	29	flow	flow	NOUN
ap-2293	80	30	coming	come	VERB
ap-2293	80	31	from	from	ADP
ap-2293	80	32	the	the	DET
ap-2293	80	33	environment	environment	NOUN
ap-2293	80	34	into	into	ADP
ap-2293	80	35	the	the	DET
ap-2293	80	36	tank	tank	NOUN
ap-2293	80	37	is	be	AUX
ap-2293	80	38	given	give	VERB
ap-2293	80	39	by	by	ADP
ap-2293	80	40	the	the	DET
ap-2293	80	41	newtonian	newtonian	ADJ
ap-2293	80	42	relationship	relationship	NOUN
ap-2293	80	43	and	and	CCONJ
ap-2293	80	44	the	the	DET
ap-2293	80	45	accumulated	accumulate	VERB
ap-2293	80	46	performance	performance	NOUN
ap-2293	80	47	is	be	AUX
ap-2293	80	48	described	describe	VERB
ap-2293	80	49	by	by	ADP
ap-2293	80	50	a	a	DET
ap-2293	80	51	calorimetric	calorimetric	ADJ
ap-2293	80	52	equation	equation	NOUN
ap-2293	80	53	concerning	concern	VERB
ap-2293	80	54	the	the	DET
ap-2293	80	55	elementary	elementary	ADJ
ap-2293	80	56	time	time	NOUN
ap-2293	80	57	change	change	NOUN
ap-2293	80	58	[	[	X
ap-2293	80	59	5–7	5–7	NOUN
ap-2293	80	60	]	]	X
ap-2293	80	61	:	:	PUNCT
ap-2293	80	62	nαstrs(tok	nαstrs(tok	NOUN
ap-2293	80	63	−	−	PROPN
ap-2293	80	64	t	t	PROPN
ap-2293	80	65	)	)	PUNCT
ap-2293	80	66	−	−	PROPN
ap-2293	80	67	pch	pch	ADJ
ap-2293	80	68	=	=	PRON
ap-2293	80	69	∑	∑	PROPN
ap-2293	80	70	(	(	PUNCT
ap-2293	80	71	mc	mc	PROPN
ap-2293	80	72	)	)	PUNCT
ap-2293	81	1	dt	dt	PROPN
ap-2293	81	2	dτ	dτ	INTJ
ap-2293	81	3	.	.	PUNCT
ap-2293	82	1	(	(	PUNCT
ap-2293	82	2	11	11	NUM
ap-2293	82	3	)	)	PUNCT
ap-2293	82	4	where	where	SCONJ
ap-2293	82	5	αstr	αstr	NOUN
ap-2293	82	6	is	be	AUX
ap-2293	82	7	the	the	DET
ap-2293	82	8	average	average	ADJ
ap-2293	82	9	value	value	NOUN
ap-2293	82	10	of	of	ADP
ap-2293	82	11	the	the	DET
ap-2293	82	12	transfer	transfer	NOUN
ap-2293	82	13	coefficient	coefficient	NOUN
ap-2293	82	14	at	at	ADP
ap-2293	82	15	the	the	DET
ap-2293	82	16	surrounding	surround	VERB
ap-2293	82	17	temperature	temperature	NOUN
ap-2293	82	18	of	of	ADP
ap-2293	82	19	8	8	NUM
ap-2293	82	20	°	°	NOUN
ap-2293	82	21	c	c	NOUN
ap-2293	82	22	and	and	CCONJ
ap-2293	82	23	in	in	ADP
ap-2293	82	24	the	the	DET
ap-2293	82	25	interval	interval	NOUN
ap-2293	82	26	of	of	ADP
ap-2293	82	27	the	the	DET
ap-2293	82	28	tank	tank	NOUN
ap-2293	82	29	surface	surface	NOUN
ap-2293	82	30	temperatures	temperature	NOUN
ap-2293	82	31	of	of	ADP
ap-2293	82	32	0	0	NUM
ap-2293	82	33	to	to	ADP
ap-2293	82	34	22	22	NUM
ap-2293	83	1	°	°	NOUN
ap-2293	83	2	c	c	X
ap-2293	83	3	(	(	PUNCT
ap-2293	83	4	wm−2	wm−2	PROPN
ap-2293	83	5	k−1	k−1	PROPN
ap-2293	83	6	)	)	PUNCT
ap-2293	83	7	;	;	PUNCT
ap-2293	83	8	s	s	X
ap-2293	83	9	is	be	AUX
ap-2293	83	10	the	the	DET
ap-2293	83	11	external	external	ADJ
ap-2293	83	12	heat	heat	NOUN
ap-2293	83	13	exchanging	exchange	VERB
ap-2293	83	14	surface	surface	NOUN
ap-2293	83	15	of	of	ADP
ap-2293	83	16	the	the	DET
ap-2293	83	17	tank	tank	NOUN
ap-2293	83	18	(	(	PUNCT
ap-2293	83	19	m2	m2	PROPN
ap-2293	83	20	)	)	PUNCT
ap-2293	83	21	;	;	PUNCT
ap-2293	83	22	tok	tok	PROPN
ap-2293	83	23	is	be	AUX
ap-2293	83	24	the	the	DET
ap-2293	83	25	environment	environment	NOUN
ap-2293	83	26	temperature	temperature	NOUN
ap-2293	83	27	(	(	PUNCT
ap-2293	83	28	°	°	ADP
ap-2293	83	29	c	c	NOUN
ap-2293	83	30	)	)	PUNCT
ap-2293	83	31	;	;	PUNCT
ap-2293	83	32	t	t	X
ap-2293	83	33	–	–	PUNCT
ap-2293	83	34	stum	stum	NOUN
ap-2293	83	35	temperature	temperature	NOUN
ap-2293	83	36	in	in	ADP
ap-2293	83	37	time	time	NOUN
ap-2293	83	38	τ	τ	X
ap-2293	83	39	(	(	PUNCT
ap-2293	83	40	°	°	ADP
ap-2293	83	41	c	c	NOUN
ap-2293	83	42	)	)	PUNCT
ap-2293	83	43	;	;	PUNCT
ap-2293	83	44	n	n	X
ap-2293	83	45	–	–	PUNCT
ap-2293	83	46	number	number	NOUN
ap-2293	83	47	of	of	ADP
ap-2293	83	48	cooling	cool	VERB
ap-2293	83	49	panels	panel	NOUN
ap-2293	83	50	(	(	PUNCT
ap-2293	83	51	1	1	NUM
ap-2293	83	52	)	)	PUNCT
ap-2293	83	53	;	;	PUNCT
ap-2293	83	54	pch	pch	ADJ
ap-2293	83	55	–	–	PUNCT
ap-2293	83	56	device	device	NOUN
ap-2293	83	57	cooling	cool	VERB
ap-2293	83	58	performance	performance	NOUN
ap-2293	83	59	(	(	PUNCT
ap-2293	83	60	w	w	NOUN
ap-2293	83	61	)	)	PUNCT
ap-2293	83	62	;	;	PUNCT
ap-2293	83	63	m	m	X
ap-2293	83	64	–	–	PUNCT
ap-2293	83	65	cooled	cool	VERB
ap-2293	83	66	material	material	NOUN
ap-2293	83	67	weight	weight	NOUN
ap-2293	83	68	(	(	PUNCT
ap-2293	83	69	kg	kg	PROPN
ap-2293	83	70	)	)	PUNCT
ap-2293	83	71	;	;	PUNCT
ap-2293	83	72	143	143	NUM
ap-2293	83	73	t.	t.	NOUN
ap-2293	83	74	brestovič	brestovič	PROPN
ap-2293	83	75	,	,	PUNCT
ap-2293	83	76	m.	m.	NOUN
ap-2293	83	77	čarnogurská	čarnogurská	NOUN
ap-2293	83	78	,	,	PUNCT
ap-2293	83	79	m.	m.	NOUN
ap-2293	83	80	přihoda	přihoda	NOUN
ap-2293	83	81	,	,	PUNCT
ap-2293	83	82	m.	m.	PROPN
ap-2293	83	83	kubík	kubík	PROPN
ap-2293	83	84	acta	acta	PROPN
ap-2293	83	85	polytechnica	polytechnica	PROPN
ap-2293	83	86	figure	figure	NOUN
ap-2293	83	87	7	7	NUM
ap-2293	83	88	.	.	PUNCT
ap-2293	84	1	course	course	NOUN
ap-2293	84	2	of	of	ADP
ap-2293	84	3	the	the	DET
ap-2293	84	4	stum	stum	NOUN
ap-2293	84	5	temperature	temperature	NOUN
ap-2293	84	6	,	,	PUNCT
ap-2293	84	7	depending	depend	VERB
ap-2293	84	8	on	on	ADP
ap-2293	84	9	time	time	NOUN
ap-2293	84	10	.	.	PUNCT
ap-2293	85	1	figure	figure	VERB
ap-2293	85	2	8	8	NUM
ap-2293	85	3	.	.	PUNCT
ap-2293	86	1	dependence	dependence	NOUN
ap-2293	86	2	of	of	ADP
ap-2293	86	3	excessive	excessive	ADJ
ap-2293	86	4	cooling	cooling	NOUN
ap-2293	86	5	of	of	ADP
ap-2293	86	6	the	the	DET
ap-2293	86	7	cooling	cool	VERB
ap-2293	86	8	mixture	mixture	NOUN
ap-2293	86	9	on	on	ADP
ap-2293	86	10	the	the	DET
ap-2293	86	11	stum	stum	NOUN
ap-2293	86	12	temperature	temperature	NOUN
ap-2293	86	13	.	.	PUNCT
ap-2293	87	1	c	c	NOUN
ap-2293	87	2	–	–	PUNCT
ap-2293	87	3	specific	specific	ADJ
ap-2293	87	4	thermal	thermal	ADJ
ap-2293	87	5	capacity	capacity	NOUN
ap-2293	87	6	of	of	ADP
ap-2293	87	7	the	the	DET
ap-2293	87	8	cooled	cooled	ADJ
ap-2293	87	9	material	material	NOUN
ap-2293	87	10	(	(	PUNCT
ap-2293	87	11	j	j	PROPN
ap-2293	87	12	kg−1	kg−1	PROPN
ap-2293	87	13	k−1	k−1	PROPN
ap-2293	87	14	)	)	PUNCT
ap-2293	87	15	.	.	PUNCT
ap-2293	88	1	the	the	DET
ap-2293	88	2	item	item	NOUN
ap-2293	88	3	of	of	ADP
ap-2293	88	4	∑	∑	PROPN
ap-2293	88	5	(	(	PUNCT
ap-2293	88	6	mc	mc	PROPN
ap-2293	88	7	)	)	PUNCT
ap-2293	88	8	in	in	ADP
ap-2293	88	9	relationship	relationship	NOUN
ap-2293	88	10	(	(	PUNCT
ap-2293	88	11	11	11	NUM
ap-2293	88	12	)	)	PUNCT
ap-2293	88	13	represents	represent	VERB
ap-2293	88	14	the	the	DET
ap-2293	88	15	total	total	ADJ
ap-2293	88	16	capacity	capacity	NOUN
ap-2293	88	17	of	of	ADP
ap-2293	88	18	the	the	DET
ap-2293	88	19	stum	stum	NOUN
ap-2293	88	20	,	,	PUNCT
ap-2293	88	21	the	the	DET
ap-2293	88	22	stainless	stainless	ADJ
ap-2293	88	23	tank	tank	NOUN
ap-2293	88	24	and	and	CCONJ
ap-2293	88	25	the	the	DET
ap-2293	88	26	cooling	cool	VERB
ap-2293	88	27	panel	panel	NOUN
ap-2293	88	28	material	material	NOUN
ap-2293	88	29	.	.	PUNCT
ap-2293	89	1	if	if	SCONJ
ap-2293	89	2	the	the	DET
ap-2293	89	3	equation	equation	NOUN
ap-2293	89	4	tv1	tv1	PROPN
ap-2293	89	5	=	=	PUNCT
ap-2293	89	6	∆tn	∆tn	PROPN
ap-2293	90	1	+	+	NUM
ap-2293	90	2	t	t	PROPN
ap-2293	90	3	applies	apply	VERB
ap-2293	90	4	,	,	PUNCT
ap-2293	90	5	the	the	DET
ap-2293	90	6	differential	differential	ADJ
ap-2293	90	7	equation	equation	NOUN
ap-2293	90	8	which	which	PRON
ap-2293	90	9	describes	describe	VERB
ap-2293	90	10	the	the	DET
ap-2293	90	11	stum	stum	NOUN
ap-2293	90	12	temperature	temperature	NOUN
ap-2293	90	13	dependence	dependence	NOUN
ap-2293	90	14	on	on	ADP
ap-2293	90	15	time	time	NOUN
ap-2293	90	16	,	,	PUNCT
ap-2293	90	17	can	can	AUX
ap-2293	90	18	be	be	AUX
ap-2293	90	19	obtained	obtain	VERB
ap-2293	90	20	by	by	ADP
ap-2293	90	21	combining	combine	VERB
ap-2293	90	22	(	(	PUNCT
ap-2293	90	23	1	1	NUM
ap-2293	90	24	)	)	PUNCT
ap-2293	90	25	and	and	CCONJ
ap-2293	90	26	(	(	PUNCT
ap-2293	90	27	11	11	NUM
ap-2293	90	28	)	)	PUNCT
ap-2293	90	29	as	as	SCONJ
ap-2293	90	30	there	there	PRON
ap-2293	90	31	is	be	VERB
ap-2293	90	32	the	the	DET
ap-2293	90	33	following	follow	VERB
ap-2293	90	34	equation	equation	NOUN
ap-2293	90	35	:	:	PUNCT
ap-2293	91	1	tv1	tv1	PROPN
ap-2293	91	2	=	=	PUNCT
ap-2293	91	3	∆tn	∆tn	PROPN
ap-2293	92	1	+	+	PROPN
ap-2293	92	2	t	t	PROPN
ap-2293	92	3	,	,	PUNCT
ap-2293	92	4	this	this	PRON
ap-2293	92	5	is	be	AUX
ap-2293	92	6	the	the	DET
ap-2293	92	7	connection	connection	NOUN
ap-2293	92	8	of	of	ADP
ap-2293	92	9	relationships	relationship	NOUN
ap-2293	92	10	(	(	PUNCT
ap-2293	92	11	1	1	NUM
ap-2293	92	12	)	)	PUNCT
ap-2293	92	13	and	and	CCONJ
ap-2293	92	14	(	(	PUNCT
ap-2293	92	15	11	11	NUM
ap-2293	92	16	)	)	PUNCT
ap-2293	92	17	,	,	PUNCT
ap-2293	92	18	a	a	DET
ap-2293	92	19	differential	differential	ADJ
ap-2293	92	20	equation	equation	NOUN
ap-2293	92	21	describing	describe	VERB
ap-2293	92	22	the	the	DET
ap-2293	92	23	stum	stum	NOUN
ap-2293	92	24	temperature	temperature	NOUN
ap-2293	92	25	dependence	dependence	NOUN
ap-2293	92	26	on	on	ADP
ap-2293	92	27	time	time	NOUN
ap-2293	92	28	,	,	PUNCT
ap-2293	92	29	which	which	PRON
ap-2293	92	30	may	may	AUX
ap-2293	92	31	be	be	AUX
ap-2293	92	32	constructed	construct	VERB
ap-2293	92	33	in	in	ADP
ap-2293	92	34	the	the	DET
ap-2293	92	35	following	follow	VERB
ap-2293	92	36	form	form	NOUN
ap-2293	92	37	:	:	PUNCT
ap-2293	92	38	dτ	dτ	NOUN
ap-2293	92	39	=	=	SYM
ap-2293	92	40	∑	∑	PROPN
ap-2293	92	41	(	(	PUNCT
ap-2293	92	42	mc	mc	NOUN
ap-2293	92	43	)	)	PUNCT
ap-2293	92	44	nαstrstok	nαstrstok	ADJ
ap-2293	92	45	−	−	PROPN
ap-2293	92	46	nαstrst−	nαstrst−	NOUN
ap-2293	92	47	at−	at−	PROPN
ap-2293	92	48	a∆tn	a∆tn	VERB
ap-2293	92	49	−	−	PROPN
ap-2293	92	50	b	b	PROPN
ap-2293	92	51	dt	dt	PROPN
ap-2293	92	52	.	.	PUNCT
ap-2293	93	1	(	(	PUNCT
ap-2293	93	2	12	12	NUM
ap-2293	93	3	)	)	PUNCT
ap-2293	93	4	if	if	SCONJ
ap-2293	93	5	the	the	DET
ap-2293	93	6	thermal	thermal	ADJ
ap-2293	93	7	losses	loss	NOUN
ap-2293	93	8	in	in	ADP
ap-2293	93	9	the	the	DET
ap-2293	93	10	distributions	distribution	NOUN
ap-2293	93	11	are	be	AUX
ap-2293	93	12	omitted	omit	VERB
ap-2293	93	13	,	,	PUNCT
ap-2293	93	14	the	the	DET
ap-2293	93	15	thermal	thermal	ADJ
ap-2293	93	16	performance	performance	NOUN
ap-2293	93	17	,	,	PUNCT
ap-2293	93	18	taken	take	VERB
ap-2293	93	19	by	by	ADP
ap-2293	93	20	all	all	DET
ap-2293	93	21	the	the	DET
ap-2293	93	22	panels	panel	NOUN
ap-2293	93	23	,	,	PUNCT
ap-2293	93	24	must	must	AUX
ap-2293	93	25	be	be	AUX
ap-2293	93	26	equal	equal	ADJ
ap-2293	93	27	to	to	ADP
ap-2293	93	28	the	the	DET
ap-2293	93	29	performance	performance	NOUN
ap-2293	93	30	of	of	ADP
ap-2293	93	31	the	the	DET
ap-2293	93	32	jn30	jn30	PROPN
ap-2293	93	33	cooling	cool	VERB
ap-2293	93	34	device	device	NOUN
ap-2293	93	35	.	.	PUNCT
ap-2293	94	1	this	this	PRON
ap-2293	94	2	shows	show	VERB
ap-2293	94	3	the	the	DET
ap-2293	94	4	uniformity	uniformity	NOUN
ap-2293	94	5	of	of	ADP
ap-2293	94	6	relationships	relationship	NOUN
ap-2293	94	7	(	(	PUNCT
ap-2293	94	8	1	1	NUM
ap-2293	94	9	)	)	PUNCT
ap-2293	94	10	and	and	CCONJ
ap-2293	94	11	(	(	PUNCT
ap-2293	94	12	9	9	NUM
ap-2293	94	13	)	)	PUNCT
ap-2293	94	14	,	,	PUNCT
ap-2293	94	15	on	on	ADP
ap-2293	94	16	the	the	DET
ap-2293	94	17	basis	basis	NOUN
ap-2293	94	18	of	of	ADP
ap-2293	94	19	which	which	PRON
ap-2293	94	20	you	you	PRON
ap-2293	94	21	can	can	AUX
ap-2293	94	22	define	define	VERB
ap-2293	94	23	the	the	DET
ap-2293	94	24	functional	functional	ADJ
ap-2293	94	25	dependence	dependence	NOUN
ap-2293	94	26	between	between	ADP
ap-2293	94	27	∆tn	∆tn	PROPN
ap-2293	94	28	and	and	CCONJ
ap-2293	94	29	the	the	DET
ap-2293	94	30	stum	stum	NOUN
ap-2293	94	31	temperature	temperature	NOUN
ap-2293	94	32	t	t	NOUN
ap-2293	94	33	in	in	ADP
ap-2293	94	34	the	the	DET
ap-2293	94	35	following	follow	VERB
ap-2293	94	36	form	form	NOUN
ap-2293	94	37	:	:	PUNCT
ap-2293	94	38	∆tn	∆tn	X
ap-2293	94	39	=	=	PUNCT
ap-2293	95	1	a	a	DET
ap-2293	95	2	d−	d−	PROPN
ap-2293	95	3	a	a	DET
ap-2293	95	4	t+	t+	NOUN
ap-2293	95	5	b	b	NUM
ap-2293	95	6	d−	d−	PROPN
ap-2293	95	7	a	a	PRON
ap-2293	95	8	.	.	PUNCT
ap-2293	96	1	(	(	PUNCT
ap-2293	96	2	13	13	NUM
ap-2293	96	3	)	)	PUNCT
ap-2293	96	4	after	after	ADP
ap-2293	96	5	inputting	inputte	VERB
ap-2293	96	6	∆tn	∆tn	PROPN
ap-2293	96	7	from	from	ADP
ap-2293	96	8	relationship	relationship	NOUN
ap-2293	96	9	(	(	PUNCT
ap-2293	96	10	13	13	NUM
ap-2293	96	11	)	)	PUNCT
ap-2293	96	12	to	to	ADP
ap-2293	96	13	(	(	PUNCT
ap-2293	96	14	12	12	NUM
ap-2293	96	15	)	)	PUNCT
ap-2293	96	16	,	,	PUNCT
ap-2293	96	17	we	we	PRON
ap-2293	96	18	get	get	VERB
ap-2293	96	19	dτ	dτ	NOUN
ap-2293	96	20	=	=	SYM
ap-2293	96	21	∑	∑	PROPN
ap-2293	96	22	(	(	PUNCT
ap-2293	96	23	mc	mc	NOUN
ap-2293	96	24	)	)	PUNCT
ap-2293	96	25	nαstrstok	nαstrstok	ADJ
ap-2293	96	26	−	−	PROPN
ap-2293	96	27	nαstrst−	nαstrst−	PROPN
ap-2293	96	28	at−	at−	PROPN
ap-2293	96	29	a	a	DET
ap-2293	96	30	a	a	DET
ap-2293	96	31	d−a	d−a	NOUN
ap-2293	96	32	t+	t+	NOUN
ap-2293	96	33	b	b	NOUN
ap-2293	96	34	d−a	d−a	NOUN
ap-2293	96	35	−	−	PROPN
ap-2293	96	36	b	b	SYM
ap-2293	96	37	dt	dt	PROPN
ap-2293	96	38	.	.	PUNCT
ap-2293	97	1	(	(	PUNCT
ap-2293	97	2	14	14	NUM
ap-2293	97	3	)	)	PUNCT
ap-2293	97	4	by	by	ADP
ap-2293	97	5	solving	solve	VERB
ap-2293	97	6	the	the	DET
ap-2293	97	7	differential	differential	ADJ
ap-2293	97	8	equation	equation	NOUN
ap-2293	97	9	(	(	PUNCT
ap-2293	97	10	14	14	NUM
ap-2293	97	11	)	)	PUNCT
ap-2293	97	12	,	,	PUNCT
ap-2293	97	13	we	we	PRON
ap-2293	97	14	get	get	VERB
ap-2293	97	15	the	the	DET
ap-2293	97	16	resulting	result	VERB
ap-2293	97	17	relationship	relationship	NOUN
ap-2293	97	18	for	for	ADP
ap-2293	97	19	the	the	DET
ap-2293	97	20	calculation	calculation	NOUN
ap-2293	97	21	of	of	ADP
ap-2293	97	22	the	the	DET
ap-2293	97	23	dependence	dependence	NOUN
ap-2293	97	24	of	of	ADP
ap-2293	97	25	the	the	DET
ap-2293	97	26	stum	stum	NOUN
ap-2293	97	27	temperature	temperature	NOUN
ap-2293	97	28	change	change	NOUN
ap-2293	97	29	on	on	ADP
ap-2293	97	30	time	time	NOUN
ap-2293	97	31	,	,	PUNCT
ap-2293	97	32	whose	whose	DET
ap-2293	97	33	solution	solution	NOUN
ap-2293	97	34	is	be	AUX
ap-2293	97	35	in	in	ADP
ap-2293	97	36	the	the	DET
ap-2293	97	37	following	follow	VERB
ap-2293	97	38	form	form	NOUN
ap-2293	97	39	:	:	PUNCT
ap-2293	97	40	τ	τ	X
ap-2293	97	41	=	=	SYM
ap-2293	97	42	1	1	NUM
ap-2293	97	43	nαstrs	nαstrs	ADJ
ap-2293	97	44	+	+	NUM
ap-2293	97	45	a+	a+	PUNCT
ap-2293	97	46	a2	a2	NOUN
ap-2293	97	47	d−a	d−a	NOUN
ap-2293	97	48	∑	∑	PUNCT
ap-2293	97	49	(	(	PUNCT
ap-2293	97	50	mc	mc	PROPN
ap-2293	97	51	)	)	PUNCT
ap-2293	97	52	ln	ln	PROPN
ap-2293	97	53	(	(	PUNCT
ap-2293	97	54	nαstrstok−	nαstrstok−	NOUN
ap-2293	97	55	ab	ab	PROPN
ap-2293	97	56	d−a	d−a	NOUN
ap-2293	97	57	−b	−b	ADV
ap-2293	97	58	)	)	PUNCT
ap-2293	97	59	−	−	PROPN
ap-2293	98	1	(	(	PUNCT
ap-2293	98	2	nαstrs+a+	nαstrs+a+	CCONJ
ap-2293	98	3	a2	a2	PROPN
ap-2293	98	4	d−a	d−a	NOUN
ap-2293	98	5	)	)	PUNCT
ap-2293	98	6	t1	t1	PROPN
ap-2293	98	7	(	(	PUNCT
ap-2293	98	8	nαstrstok−	nαstrstok−	NOUN
ap-2293	98	9	ab	ab	PROPN
ap-2293	98	10	d−a	d−a	NOUN
ap-2293	98	11	−b	−b	ADV
ap-2293	98	12	)	)	PUNCT
ap-2293	98	13	−	−	PROPN
ap-2293	98	14	(	(	PUNCT
ap-2293	98	15	nαstrs+a+	nαstrs+a+	CCONJ
ap-2293	98	16	a2	a2	PROPN
ap-2293	98	17	d−a	d−a	NOUN
ap-2293	98	18	)	)	PUNCT
ap-2293	98	19	t	t	NOUN
ap-2293	98	20	,	,	PUNCT
ap-2293	98	21	(	(	PUNCT
ap-2293	98	22	15	15	NUM
ap-2293	98	23	)	)	PUNCT
ap-2293	98	24	144	144	NUM
ap-2293	98	25	vol	vol	NOUN
ap-2293	98	26	.	.	PUNCT
ap-2293	99	1	55	55	NUM
ap-2293	99	2	no	no	NOUN
ap-2293	99	3	.	.	PUNCT
ap-2293	100	1	3/2015	3/2015	NUM
ap-2293	100	2	simulation	simulation	NOUN
ap-2293	100	3	of	of	ADP
ap-2293	100	4	heat	heat	NOUN
ap-2293	100	5	transport	transport	NOUN
ap-2293	100	6	where	where	SCONJ
ap-2293	100	7	t1	t1	NOUN
ap-2293	100	8	is	be	AUX
ap-2293	100	9	the	the	DET
ap-2293	100	10	stum	stum	NOUN
ap-2293	100	11	temperature	temperature	NOUN
ap-2293	100	12	at	at	ADP
ap-2293	100	13	the	the	DET
ap-2293	100	14	beginning	beginning	NOUN
ap-2293	100	15	of	of	ADP
ap-2293	100	16	the	the	DET
ap-2293	100	17	cooling	cool	VERB
ap-2293	100	18	process	process	NOUN
ap-2293	100	19	(	(	PUNCT
ap-2293	100	20	°	°	ADP
ap-2293	100	21	c	c	NOUN
ap-2293	100	22	)	)	PUNCT
ap-2293	100	23	.	.	PUNCT
ap-2293	101	1	the	the	DET
ap-2293	101	2	stum	stum	NOUN
ap-2293	101	3	cooling	cool	VERB
ap-2293	101	4	time	time	NOUN
ap-2293	101	5	according	accord	VERB
ap-2293	101	6	to	to	ADP
ap-2293	101	7	(	(	PUNCT
ap-2293	101	8	15	15	NUM
ap-2293	101	9	)	)	PUNCT
ap-2293	101	10	was	be	AUX
ap-2293	101	11	calculated	calculate	VERB
ap-2293	101	12	for	for	ADP
ap-2293	101	13	the	the	DET
ap-2293	101	14	following	follow	VERB
ap-2293	101	15	parameters	parameter	NOUN
ap-2293	101	16	:	:	PUNCT
ap-2293	101	17	number	number	NOUN
ap-2293	101	18	of	of	ADP
ap-2293	101	19	tanks	tank	NOUN
ap-2293	101	20	n	n	NOUN
ap-2293	101	21	=	=	SYM
ap-2293	101	22	24.5pcs	24.5pc	NOUN
ap-2293	101	23	,	,	PUNCT
ap-2293	101	24	αstr	αstr	NOUN
ap-2293	101	25	=	=	SYM
ap-2293	101	26	2.853wm−2	2.853wm−2	NUM
ap-2293	101	27	k−1	k−1	PROPN
ap-2293	101	28	,	,	PUNCT
ap-2293	101	29	surface	surface	NOUN
ap-2293	101	30	s	s	PART
ap-2293	101	31	=	=	SYM
ap-2293	101	32	11.875m2	11.875m2	NUM
ap-2293	101	33	,	,	PUNCT
ap-2293	101	34	coefficient	coefficient	NOUN
ap-2293	101	35	of	of	ADP
ap-2293	101	36	linear	linear	PROPN
ap-2293	101	37	regression	regression	NOUN
ap-2293	101	38	from	from	ADP
ap-2293	101	39	(	(	PUNCT
ap-2293	101	40	1	1	NUM
ap-2293	101	41	)	)	PUNCT
ap-2293	101	42	a	a	DET
ap-2293	101	43	=	=	ADJ
ap-2293	101	44	938.98wk−1	938.98wk−1	NOUN
ap-2293	101	45	,	,	PUNCT
ap-2293	101	46	coefficient	coefficient	NOUN
ap-2293	101	47	of	of	ADP
ap-2293	101	48	linear	linear	PROPN
ap-2293	101	49	regression	regression	NOUN
ap-2293	101	50	from	from	ADP
ap-2293	101	51	(	(	PUNCT
ap-2293	101	52	1	1	NUM
ap-2293	101	53	)	)	PUNCT
ap-2293	101	54	b	b	NOUN
ap-2293	101	55	=	=	SYM
ap-2293	101	56	15380w	15380w	NUM
ap-2293	101	57	,	,	PUNCT
ap-2293	101	58	coefficient	coefficient	NOUN
ap-2293	101	59	of	of	ADP
ap-2293	101	60	linear	linear	PROPN
ap-2293	101	61	regression	regression	NOUN
ap-2293	101	62	from	from	ADP
ap-2293	101	63	(	(	PUNCT
ap-2293	101	64	9	9	NUM
ap-2293	101	65	)	)	PUNCT
ap-2293	101	66	d	d	NOUN
ap-2293	101	67	=	=	SYM
ap-2293	101	68	−2000wk−1	−2000wk−1	PROPN
ap-2293	101	69	,	,	PUNCT
ap-2293	101	70	stum	stum	NOUN
ap-2293	101	71	volume	volume	NOUN
ap-2293	101	72	in	in	ADP
ap-2293	101	73	one	one	NUM
ap-2293	101	74	tank	tank	NOUN
ap-2293	101	75	v	v	NOUN
ap-2293	101	76	=	=	SYM
ap-2293	101	77	3.23m3	3.23m3	NUM
ap-2293	101	78	,	,	PUNCT
ap-2293	101	79	stum	stum	NOUN
ap-2293	101	80	density	density	NOUN
ap-2293	101	81	%	%	NOUN
ap-2293	101	82	=	=	SYM
ap-2293	101	83	1400	1400	NUM
ap-2293	101	84	kgm−3	kgm−3	PROPN
ap-2293	101	85	,	,	PUNCT
ap-2293	101	86	steel	steel	NOUN
ap-2293	101	87	weight	weight	NOUN
ap-2293	101	88	moc	moc	NOUN
ap-2293	101	89	=	=	PROPN
ap-2293	101	90	148.9	148.9	NUM
ap-2293	101	91	kg	kg	NOUN
ap-2293	101	92	(	(	PUNCT
ap-2293	101	93	weight	weight	NOUN
ap-2293	101	94	of	of	ADP
ap-2293	101	95	the	the	DET
ap-2293	101	96	steel	steel	NOUN
ap-2293	101	97	tank	tank	NOUN
ap-2293	101	98	coating	coating	NOUN
ap-2293	101	99	and	and	CCONJ
ap-2293	101	100	weight	weight	NOUN
ap-2293	101	101	of	of	ADP
ap-2293	101	102	the	the	DET
ap-2293	101	103	cooling	cool	VERB
ap-2293	101	104	panel	panel	NOUN
ap-2293	101	105	)	)	PUNCT
ap-2293	101	106	,	,	PUNCT
ap-2293	101	107	specific	specific	ADJ
ap-2293	101	108	thermal	thermal	ADJ
ap-2293	101	109	capacity	capacity	NOUN
ap-2293	101	110	of	of	ADP
ap-2293	101	111	steel	steel	NOUN
ap-2293	101	112	coc	coc	NOUN
ap-2293	101	113	=	=	NUM
ap-2293	101	114	465	465	NUM
ap-2293	101	115	j	j	PROPN
ap-2293	101	116	kg−1	kg−1	PROPN
ap-2293	101	117	k−1	k−1	PROPN
ap-2293	101	118	,	,	PUNCT
ap-2293	101	119	temperature	temperature	NOUN
ap-2293	101	120	of	of	ADP
ap-2293	101	121	environment	environment	NOUN
ap-2293	101	122	tok	tok	NOUN
ap-2293	102	1	=	=	NOUN
ap-2293	103	1	8	8	NUM
ap-2293	103	2	°	°	NOUN
ap-2293	103	3	c	c	NOUN
ap-2293	103	4	,	,	PUNCT
ap-2293	103	5	stum	stum	NOUN
ap-2293	103	6	thermal	thermal	ADJ
ap-2293	103	7	capacity	capacity	NOUN
ap-2293	103	8	c	c	NOUN
ap-2293	103	9	=	=	SYM
ap-2293	103	10	3460	3460	NUM
ap-2293	103	11	j	j	PROPN
ap-2293	103	12	kg−1	kg−1	PROPN
ap-2293	103	13	k−1	k−1	PROPN
ap-2293	103	14	,	,	PUNCT
ap-2293	103	15	initial	initial	ADJ
ap-2293	103	16	temperature	temperature	NOUN
ap-2293	103	17	of	of	ADP
ap-2293	103	18	the	the	DET
ap-2293	103	19	cooled	cooled	ADJ
ap-2293	103	20	stum	stum	NOUN
ap-2293	103	21	t1	t1	NOUN
ap-2293	103	22	=	=	NOUN
ap-2293	103	23	22	22	NUM
ap-2293	103	24	°	°	SYM
ap-2293	103	25	c	c	NOUN
ap-2293	103	26	.	.	PUNCT
ap-2293	104	1	the	the	DET
ap-2293	104	2	time	time	NOUN
ap-2293	104	3	course	course	NOUN
ap-2293	104	4	of	of	ADP
ap-2293	104	5	the	the	DET
ap-2293	104	6	stum	stum	NOUN
ap-2293	104	7	is	be	AUX
ap-2293	104	8	shown	show	VERB
ap-2293	104	9	in	in	ADP
ap-2293	104	10	figure	figure	NOUN
ap-2293	104	11	7	7	NUM
ap-2293	104	12	.	.	PUNCT
ap-2293	105	1	on	on	ADP
ap-2293	105	2	the	the	DET
ap-2293	105	3	basis	basis	NOUN
ap-2293	105	4	of	of	ADP
ap-2293	105	5	the	the	DET
ap-2293	105	6	described	describe	VERB
ap-2293	105	7	model	model	NOUN
ap-2293	105	8	,	,	PUNCT
ap-2293	105	9	we	we	PRON
ap-2293	105	10	may	may	AUX
ap-2293	105	11	calculate	calculate	VERB
ap-2293	105	12	the	the	DET
ap-2293	105	13	dependence	dependence	NOUN
ap-2293	105	14	of	of	ADP
ap-2293	105	15	excessive	excessive	ADJ
ap-2293	105	16	cooling	cooling	NOUN
ap-2293	105	17	of	of	ADP
ap-2293	105	18	the	the	DET
ap-2293	105	19	cooling	cool	VERB
ap-2293	105	20	mixture	mixture	NOUN
ap-2293	105	21	on	on	ADP
ap-2293	105	22	the	the	DET
ap-2293	105	23	stum	stum	NOUN
ap-2293	105	24	temperature	temperature	NOUN
ap-2293	105	25	(	(	PUNCT
ap-2293	105	26	figure	figure	NOUN
ap-2293	105	27	8)	8)	NUM
ap-2293	105	28	.	.	PUNCT
ap-2293	106	1	figure	figure	NOUN
ap-2293	106	2	8	8	NUM
ap-2293	106	3	shows	show	VERB
ap-2293	106	4	that	that	SCONJ
ap-2293	106	5	at	at	ADP
ap-2293	106	6	a	a	DET
ap-2293	106	7	stum	stum	NOUN
ap-2293	106	8	temperature	temperature	NOUN
ap-2293	106	9	of	of	ADP
ap-2293	106	10	0	0	NUM
ap-2293	106	11	°	°	NOUN
ap-2293	106	12	c	c	NOUN
ap-2293	106	13	,	,	PUNCT
ap-2293	106	14	the	the	DET
ap-2293	106	15	temperature	temperature	NOUN
ap-2293	106	16	of	of	ADP
ap-2293	106	17	the	the	DET
ap-2293	106	18	cooling	cool	VERB
ap-2293	106	19	mixture	mixture	NOUN
ap-2293	106	20	is	be	AUX
ap-2293	106	21	-5.2	-5.2	PUNCT
ap-2293	106	22	°	°	PROPN
ap-2293	106	23	c	c	NOUN
ap-2293	106	24	.	.	PUNCT
ap-2293	107	1	at	at	ADP
ap-2293	107	2	this	this	DET
ap-2293	107	3	temperature	temperature	NOUN
ap-2293	107	4	,	,	PUNCT
ap-2293	107	5	frost	frost	NOUN
ap-2293	107	6	may	may	AUX
ap-2293	107	7	form	form	VERB
ap-2293	107	8	on	on	ADP
ap-2293	107	9	the	the	DET
ap-2293	107	10	heat	heat	NOUN
ap-2293	107	11	exchanging	exchange	VERB
ap-2293	107	12	surface	surface	NOUN
ap-2293	107	13	,	,	PUNCT
ap-2293	107	14	which	which	PRON
ap-2293	107	15	significantly	significantly	ADV
ap-2293	107	16	increases	increase	VERB
ap-2293	107	17	the	the	DET
ap-2293	107	18	thermal	thermal	ADJ
ap-2293	107	19	resistance	resistance	NOUN
ap-2293	107	20	of	of	ADP
ap-2293	107	21	the	the	DET
ap-2293	107	22	cooling	cool	VERB
ap-2293	107	23	panel	panel	NOUN
ap-2293	107	24	and	and	CCONJ
ap-2293	107	25	lowers	lower	VERB
ap-2293	107	26	the	the	DET
ap-2293	107	27	stum	stum	NOUN
ap-2293	107	28	cooling	cool	VERB
ap-2293	107	29	intensity	intensity	NOUN
ap-2293	107	30	.	.	PUNCT
ap-2293	108	1	an	an	DET
ap-2293	108	2	increase	increase	NOUN
ap-2293	108	3	of	of	ADP
ap-2293	108	4	the	the	DET
ap-2293	108	5	cooling	cool	VERB
ap-2293	108	6	mixture	mixture	NOUN
ap-2293	108	7	temperature	temperature	NOUN
ap-2293	108	8	can	can	AUX
ap-2293	108	9	be	be	AUX
ap-2293	108	10	achieved	achieve	VERB
ap-2293	108	11	for	for	ADP
ap-2293	108	12	example	example	NOUN
ap-2293	108	13	by	by	ADP
ap-2293	108	14	increasing	increase	VERB
ap-2293	108	15	the	the	DET
ap-2293	108	16	heat	heat	NOUN
ap-2293	108	17	exchanging	exchange	VERB
ap-2293	108	18	surface	surface	NOUN
ap-2293	108	19	of	of	ADP
ap-2293	108	20	the	the	DET
ap-2293	108	21	cooling	cool	VERB
ap-2293	108	22	panel	panel	NOUN
ap-2293	108	23	.	.	PUNCT
ap-2293	109	1	4	4	X
ap-2293	109	2	.	.	X
ap-2293	109	3	conclusion	conclusion	VERB
ap-2293	109	4	the	the	DET
ap-2293	109	5	methodology	methodology	NOUN
ap-2293	109	6	for	for	ADP
ap-2293	109	7	determining	determine	VERB
ap-2293	109	8	cooling	cool	VERB
ap-2293	109	9	parameters	parameter	NOUN
ap-2293	109	10	using	use	VERB
ap-2293	109	11	a	a	DET
ap-2293	109	12	combination	combination	NOUN
ap-2293	109	13	of	of	ADP
ap-2293	109	14	a	a	DET
ap-2293	109	15	numeric	numeric	NOUN
ap-2293	109	16	and	and	CCONJ
ap-2293	109	17	an	an	DET
ap-2293	109	18	analytical	analytical	ADJ
ap-2293	109	19	calculation	calculation	NOUN
ap-2293	109	20	enables	enable	VERB
ap-2293	109	21	us	we	PRON
ap-2293	109	22	to	to	PART
ap-2293	109	23	describe	describe	VERB
ap-2293	109	24	the	the	DET
ap-2293	109	25	dynamic	dynamic	ADJ
ap-2293	109	26	behaviour	behaviour	NOUN
ap-2293	109	27	of	of	ADP
ap-2293	109	28	the	the	DET
ap-2293	109	29	cooling	cool	VERB
ap-2293	109	30	system	system	NOUN
ap-2293	109	31	precisely	precisely	ADV
ap-2293	109	32	.	.	PUNCT
ap-2293	110	1	with	with	ADP
ap-2293	110	2	the	the	DET
ap-2293	110	3	help	help	NOUN
ap-2293	110	4	of	of	ADP
ap-2293	110	5	the	the	DET
ap-2293	110	6	described	describe	VERB
ap-2293	110	7	model	model	NOUN
ap-2293	110	8	,	,	PUNCT
ap-2293	110	9	it	it	PRON
ap-2293	110	10	is	be	AUX
ap-2293	110	11	possible	possible	ADJ
ap-2293	110	12	to	to	PART
ap-2293	110	13	determine	determine	VERB
ap-2293	110	14	the	the	DET
ap-2293	110	15	cooling	cool	VERB
ap-2293	110	16	performance	performance	NOUN
ap-2293	110	17	,	,	PUNCT
ap-2293	110	18	the	the	DET
ap-2293	110	19	cooling	cool	VERB
ap-2293	110	20	factor	factor	NOUN
ap-2293	110	21	and	and	CCONJ
ap-2293	110	22	the	the	DET
ap-2293	110	23	excessive	excessive	ADJ
ap-2293	110	24	cooling	cooling	NOUN
ap-2293	110	25	of	of	ADP
ap-2293	110	26	the	the	DET
ap-2293	110	27	cooling	cool	VERB
ap-2293	110	28	medium	medium	NOUN
ap-2293	110	29	not	not	PART
ap-2293	110	30	only	only	ADV
ap-2293	110	31	in	in	ADP
ap-2293	110	32	relation	relation	NOUN
ap-2293	110	33	to	to	ADP
ap-2293	110	34	the	the	DET
ap-2293	110	35	temperature	temperature	NOUN
ap-2293	110	36	of	of	ADP
ap-2293	110	37	the	the	DET
ap-2293	110	38	cooled	cool	VERB
ap-2293	110	39	solution	solution	NOUN
ap-2293	110	40	,	,	PUNCT
ap-2293	110	41	but	but	CCONJ
ap-2293	110	42	also	also	ADV
ap-2293	110	43	to	to	ADP
ap-2293	110	44	the	the	DET
ap-2293	110	45	changes	change	NOUN
ap-2293	110	46	of	of	ADP
ap-2293	110	47	these	these	DET
ap-2293	110	48	parameters	parameter	NOUN
ap-2293	110	49	over	over	ADP
ap-2293	110	50	time	time	NOUN
ap-2293	110	51	.	.	PUNCT
ap-2293	111	1	the	the	DET
ap-2293	111	2	executed	execute	VERB
ap-2293	111	3	thermal	thermal	ADJ
ap-2293	111	4	calculations	calculation	NOUN
ap-2293	111	5	show	show	VERB
ap-2293	111	6	that	that	SCONJ
ap-2293	111	7	the	the	DET
ap-2293	111	8	analysed	analyse	VERB
ap-2293	111	9	cooling	cool	VERB
ap-2293	111	10	device	device	NOUN
ap-2293	111	11	can	can	AUX
ap-2293	111	12	not	not	PART
ap-2293	111	13	cool	cool	VERB
ap-2293	111	14	78.21m3	78.21m3	NUM
ap-2293	111	15	of	of	ADP
ap-2293	111	16	stum	stum	NOUN
ap-2293	111	17	in	in	ADP
ap-2293	111	18	48	48	NUM
ap-2293	111	19	hours	hour	NOUN
ap-2293	111	20	from	from	ADP
ap-2293	111	21	the	the	DET
ap-2293	111	22	initial	initial	ADJ
ap-2293	111	23	temperature	temperature	NOUN
ap-2293	111	24	of	of	ADP
ap-2293	111	25	22	22	NUM
ap-2293	111	26	°	°	NOUN
ap-2293	111	27	c	c	NOUN
ap-2293	111	28	to	to	ADP
ap-2293	111	29	0	0	NUM
ap-2293	111	30	°	°	NOUN
ap-2293	111	31	c	c	NOUN
ap-2293	111	32	,	,	PUNCT
ap-2293	111	33	but	but	CCONJ
ap-2293	111	34	that	that	SCONJ
ap-2293	111	35	it	it	PRON
ap-2293	111	36	makes	make	VERB
ap-2293	111	37	it	it	PRON
ap-2293	111	38	possible	possible	ADJ
ap-2293	111	39	,	,	PUNCT
ap-2293	111	40	within	within	ADP
ap-2293	111	41	the	the	DET
ap-2293	111	42	given	give	VERB
ap-2293	111	43	timeframe	timeframe	NOUN
ap-2293	111	44	,	,	PUNCT
ap-2293	111	45	to	to	PART
ap-2293	111	46	cool	cool	VERB
ap-2293	111	47	the	the	DET
ap-2293	111	48	stum	stum	NOUN
ap-2293	111	49	to	to	ADP
ap-2293	111	50	the	the	DET
ap-2293	111	51	temperature	temperature	NOUN
ap-2293	111	52	of	of	ADP
ap-2293	111	53	10	10	NUM
ap-2293	111	54	°	°	NOUN
ap-2293	111	55	c	c	NOUN
ap-2293	111	56	(	(	PUNCT
ap-2293	111	57	arrows	arrow	NOUN
ap-2293	111	58	in	in	ADP
ap-2293	111	59	figure	figure	NOUN
ap-2293	111	60	7	7	NUM
ap-2293	111	61	)	)	PUNCT
ap-2293	111	62	.	.	PUNCT
ap-2293	112	1	at	at	ADP
ap-2293	112	2	the	the	DET
ap-2293	112	3	moment	moment	NOUN
ap-2293	112	4	,	,	PUNCT
ap-2293	112	5	the	the	DET
ap-2293	112	6	cooling	cool	VERB
ap-2293	112	7	aggregate	aggregate	NOUN
ap-2293	112	8	is	be	AUX
ap-2293	112	9	only	only	ADV
ap-2293	112	10	fully	fully	ADV
ap-2293	112	11	sufficient	sufficient	ADJ
ap-2293	112	12	for	for	ADP
ap-2293	112	13	the	the	DET
ap-2293	112	14	cooling	cooling	NOUN
ap-2293	112	15	of	of	ADP
ap-2293	112	16	the	the	DET
ap-2293	112	17	given	give	VERB
ap-2293	112	18	amount	amount	NOUN
ap-2293	112	19	of	of	ADP
ap-2293	112	20	stum	stum	NOUN
ap-2293	112	21	to	to	ADP
ap-2293	112	22	the	the	DET
ap-2293	112	23	temperature	temperature	NOUN
ap-2293	112	24	of	of	ADP
ap-2293	112	25	the	the	DET
ap-2293	112	26	managed	manage	VERB
ap-2293	112	27	fermentation	fermentation	NOUN
ap-2293	112	28	,	,	PUNCT
ap-2293	112	29	which	which	PRON
ap-2293	112	30	is	be	AUX
ap-2293	112	31	approximately	approximately	ADV
ap-2293	112	32	7	7	NUM
ap-2293	112	33	°	°	NOUN
ap-2293	112	34	c	c	NOUN
ap-2293	112	35	.	.	PUNCT
ap-2293	113	1	the	the	DET
ap-2293	113	2	requirement	requirement	NOUN
ap-2293	113	3	of	of	ADP
ap-2293	113	4	cooling	cool	VERB
ap-2293	113	5	the	the	DET
ap-2293	113	6	stum	stum	NOUN
ap-2293	113	7	to	to	ADP
ap-2293	113	8	the	the	DET
ap-2293	113	9	temperature	temperature	NOUN
ap-2293	113	10	of	of	ADP
ap-2293	113	11	approximately	approximately	ADV
ap-2293	113	12	0	0	NUM
ap-2293	113	13	°	°	ADP
ap-2293	113	14	c	c	NOUN
ap-2293	113	15	in	in	ADP
ap-2293	113	16	2	2	NUM
ap-2293	113	17	days	day	NOUN
ap-2293	113	18	will	will	AUX
ap-2293	113	19	be	be	AUX
ap-2293	113	20	fulfilled	fulfil	VERB
ap-2293	113	21	if	if	SCONJ
ap-2293	113	22	the	the	DET
ap-2293	113	23	performance	performance	NOUN
ap-2293	113	24	of	of	ADP
ap-2293	113	25	the	the	DET
ap-2293	113	26	cooling	cool	VERB
ap-2293	113	27	aggregate	aggregate	ADJ
ap-2293	113	28	increases	increase	NOUN
ap-2293	113	29	from	from	ADP
ap-2293	113	30	the	the	DET
ap-2293	113	31	current	current	ADJ
ap-2293	113	32	27.5	27.5	NUM
ap-2293	113	33	kw	kw	NOUN
ap-2293	113	34	to	to	ADP
ap-2293	113	35	approximately	approximately	ADV
ap-2293	113	36	47	47	NUM
ap-2293	113	37	kw	kw	NOUN
ap-2293	113	38	.	.	PUNCT
ap-2293	114	1	due	due	ADP
ap-2293	114	2	to	to	ADP
ap-2293	114	3	the	the	DET
ap-2293	114	4	large	large	ADJ
ap-2293	114	5	temperature	temperature	NOUN
ap-2293	114	6	difference	difference	NOUN
ap-2293	114	7	between	between	ADP
ap-2293	114	8	the	the	DET
ap-2293	114	9	cooling	cool	VERB
ap-2293	114	10	mixture	mixture	NOUN
ap-2293	114	11	temperature	temperature	NOUN
ap-2293	114	12	and	and	CCONJ
ap-2293	114	13	the	the	DET
ap-2293	114	14	stum	stum	NOUN
ap-2293	114	15	temperature	temperature	NOUN
ap-2293	114	16	at	at	ADP
ap-2293	114	17	the	the	DET
ap-2293	114	18	performance	performance	NOUN
ap-2293	114	19	of	of	ADP
ap-2293	114	20	47	47	NUM
ap-2293	114	21	kw	kw	NOUN
ap-2293	114	22	,	,	PUNCT
ap-2293	114	23	it	it	PRON
ap-2293	114	24	might	might	AUX
ap-2293	114	25	be	be	AUX
ap-2293	114	26	appropriate	appropriate	ADJ
ap-2293	114	27	to	to	PART
ap-2293	114	28	also	also	ADV
ap-2293	114	29	increase	increase	VERB
ap-2293	114	30	the	the	DET
ap-2293	114	31	total	total	ADJ
ap-2293	114	32	heat	heat	NOUN
ap-2293	114	33	exchanging	exchange	VERB
ap-2293	114	34	surface	surface	NOUN
ap-2293	114	35	of	of	ADP
ap-2293	114	36	the	the	DET
ap-2293	114	37	cooling	cool	VERB
ap-2293	114	38	panels	panel	NOUN
ap-2293	114	39	.	.	PUNCT
ap-2293	115	1	acknowledgements	acknowledgement	NOUN
ap-2293	115	2	this	this	DET
ap-2293	115	3	article	article	NOUN
ap-2293	115	4	was	be	AUX
ap-2293	115	5	written	write	VERB
ap-2293	115	6	with	with	ADP
ap-2293	115	7	the	the	DET
ap-2293	115	8	support	support	NOUN
ap-2293	115	9	of	of	ADP
ap-2293	115	10	vega	vega	PROPN
ap-2293	115	11	projects	project	NOUN
ap-2293	115	12	1/0004/2014	1/0004/2014	PRON
ap-2293	115	13	mš	mš	INTJ
ap-2293	115	14	sr	sr	PROPN
ap-2293	115	15	,	,	PUNCT
ap-2293	115	16	vega	vega	PROPN
ap-2293	115	17	1/0686/13	1/0686/13	PROPN
ap-2293	116	1	mš	mš	PROPN
ap-2293	116	2	sr	sr	PROPN
ap-2293	116	3	and	and	CCONJ
ap-2293	116	4	sp2015/86	sp2015/86	NOUN
ap-2293	116	5	-	-	PUNCT
ap-2293	116	6	fmmi	fmmi	ADJ
ap-2293	116	7	všb	všb	PROPN
ap-2293	116	8	tuo	tuo	PROPN
ap-2293	116	9	.	.	PUNCT
ap-2293	117	1	references	reference	NOUN
ap-2293	117	2	[	[	X
ap-2293	117	3	1	1	NUM
ap-2293	117	4	]	]	X
ap-2293	117	5	vdi	vdi	NOUN
ap-2293	117	6	wärmeatlas	wärmeatla	NOUN
ap-2293	117	7	,	,	PUNCT
ap-2293	117	8	gvc	gvc	PROPN
ap-2293	117	9	,	,	PUNCT
ap-2293	117	10	berlin	berlin	PROPN
ap-2293	117	11	,	,	PUNCT
ap-2293	117	12	2006	2006	NUM
ap-2293	117	13	,	,	PUNCT
ap-2293	117	14	10th	10th	ADJ
ap-2293	117	15	edition	edition	NOUN
ap-2293	117	16	,	,	PUNCT
ap-2293	117	17	isbn-10	isbn-10	PROPN
ap-2293	117	18	3	3	NUM
ap-2293	117	19	-	-	SYM
ap-2293	117	20	540	540	NUM
ap-2293	117	21	-	-	PUNCT
ap-2293	117	22	25504	25504	NUM
ap-2293	117	23	-	-	SYM
ap-2293	117	24	4	4	NUM
ap-2293	117	25	.	.	PUNCT
ap-2293	118	1	[	[	X
ap-2293	118	2	2	2	X
ap-2293	118	3	]	]	X
ap-2293	118	4	heindrich	heindrich	X
ap-2293	118	5	j.	j.	PROPN
ap-2293	118	6	vlastnosti	vlastnosti	PROPN
ap-2293	118	7	tekutín	tekutín	NOUN
ap-2293	118	8	.	.	PUNCT
ap-2293	119	1	sntl	sntl	ADJ
ap-2293	119	2	alfa	alfa	PROPN
ap-2293	119	3	,	,	PUNCT
ap-2293	119	4	1980	1980	NUM
ap-2293	119	5	.	.	PUNCT
ap-2293	120	1	[	[	X
ap-2293	120	2	3	3	NUM
ap-2293	120	3	]	]	X
ap-2293	120	4	werner	werner	NOUN
ap-2293	120	5	,	,	PUNCT
ap-2293	120	6	m.	m.	NOUN
ap-2293	120	7	,	,	PUNCT
ap-2293	120	8	baars	baar	NOUN
ap-2293	120	9	,	,	PUNCT
ap-2293	120	10	a.	a.	NOUN
ap-2293	120	11	,	,	PUNCT
ap-2293	120	12	werner	werner	PROPN
ap-2293	120	13	,	,	PUNCT
ap-2293	120	14	f.	f.	PROPN
ap-2293	120	15	,	,	PUNCT
ap-2293	120	16	eder	eder	NOUN
ap-2293	120	17	,	,	PUNCT
ap-2293	120	18	c.	c.	NOUN
ap-2293	120	19	,	,	PUNCT
ap-2293	120	20	delgado	delgado	PROPN
ap-2293	120	21	,	,	PUNCT
ap-2293	120	22	a.	a.	NOUN
ap-2293	120	23	thermal	thermal	ADJ
ap-2293	120	24	conductivity	conductivity	NOUN
ap-2293	120	25	of	of	ADP
ap-2293	120	26	aqueous	aqueous	ADJ
ap-2293	120	27	sugar	sugar	NOUN
ap-2293	120	28	solutions	solution	NOUN
ap-2293	120	29	under	under	ADP
ap-2293	120	30	high	high	ADJ
ap-2293	120	31	pressure	pressure	NOUN
ap-2293	120	32	,	,	PUNCT
ap-2293	120	33	international	international	ADJ
ap-2293	120	34	journal	journal	NOUN
ap-2293	120	35	of	of	ADP
ap-2293	120	36	thermophysics	thermophysic	NOUN
ap-2293	120	37	(	(	PUNCT
ap-2293	120	38	2007	2007	NUM
ap-2293	120	39	)	)	PUNCT
ap-2293	120	40	28	28	NUM
ap-2293	120	41	,	,	PUNCT
ap-2293	120	42	1161–1180	1161–1180	NUM
ap-2293	120	43	,	,	PUNCT
ap-2293	120	44	issn	issn	PROPN
ap-2293	120	45	0195	0195	NUM
ap-2293	120	46	-	-	PUNCT
ap-2293	120	47	928x	928x	NOUN
ap-2293	120	48	.	.	PUNCT
ap-2293	121	1	[	[	X
ap-2293	121	2	4	4	NUM
ap-2293	121	3	]	]	X
ap-2293	121	4	material	material	NOUN
ap-2293	121	5	of	of	ADP
ap-2293	121	6	nordic	nordic	ADJ
ap-2293	121	7	sugar	sugar	NOUN
ap-2293	121	8	company	company	NOUN
ap-2293	121	9	:	:	PUNCT
ap-2293	121	10	the	the	DET
ap-2293	121	11	functional	functional	ADJ
ap-2293	121	12	properties	property	NOUN
ap-2293	121	13	of	of	ADP
ap-2293	121	14	sugar	sugar	NOUN
ap-2293	121	15	.	.	PUNCT
ap-2293	122	1	[	[	X
ap-2293	122	2	5	5	NUM
ap-2293	122	3	]	]	SYM
ap-2293	122	4	himmel	himmel	X
ap-2293	122	5	,	,	PUNCT
ap-2293	122	6	m.	m.	NOUN
ap-2293	122	7	on	on	ADP
ap-2293	122	8	the	the	DET
ap-2293	122	9	solvability	solvability	NOUN
ap-2293	122	10	of	of	ADP
ap-2293	122	11	some	some	DET
ap-2293	122	12	partial	partial	ADJ
ap-2293	122	13	differential	differential	NOUN
ap-2293	122	14	inequality	inequality	NOUN
ap-2293	122	15	,	,	PUNCT
ap-2293	122	16	acta	acta	PROPN
ap-2293	122	17	polytechnica	polytechnica	PROPN
ap-2293	122	18	,	,	PUNCT
ap-2293	122	19	vol	vol	NOUN
ap-2293	122	20	.	.	PROPN
ap-2293	123	1	53	53	NUM
ap-2293	123	2	,	,	PUNCT
ap-2293	123	3	no	no	DET
ap-2293	123	4	3	3	NUM
ap-2293	123	5	(	(	PUNCT
ap-2293	123	6	2013	2013	NUM
ap-2293	123	7	)	)	PUNCT
ap-2293	123	8	.	.	PUNCT
ap-2293	124	1	[	[	X
ap-2293	124	2	6	6	NUM
ap-2293	124	3	]	]	SYM
ap-2293	124	4	duransky	duransky	NOUN
ap-2293	124	5	,	,	PUNCT
ap-2293	124	6	p.	p.	PROPN
ap-2293	124	7	,	,	PUNCT
ap-2293	124	8	papucik	papucik	PROPN
ap-2293	124	9	,	,	PUNCT
ap-2293	124	10	s.	s.	PROPN
ap-2293	124	11	,	,	PUNCT
ap-2293	124	12	jandacka	jandacka	PROPN
ap-2293	124	13	,	,	PUNCT
ap-2293	124	14	j.	j.	PROPN
ap-2293	124	15	,	,	PUNCT
ap-2293	124	16	holubcik	holubcik	PROPN
ap-2293	124	17	,	,	PUNCT
ap-2293	124	18	m.	m.	NOUN
ap-2293	124	19	,	,	PUNCT
ap-2293	124	20	nosek	nosek	PROPN
ap-2293	124	21	,	,	PUNCT
ap-2293	124	22	r.	r.	PROPN
ap-2293	124	23	design	design	PROPN
ap-2293	124	24	of	of	ADP
ap-2293	124	25	heat	heat	NOUN
ap-2293	124	26	exchanger	exchanger	NOUN
ap-2293	124	27	for	for	ADP
ap-2293	124	28	ericsson	ericsson	PROPN
ap-2293	124	29	-	-	PUNCT
ap-2293	124	30	brayton	brayton	PROPN
ap-2293	124	31	piston	piston	NOUN
ap-2293	124	32	engine	engine	NOUN
ap-2293	124	33	.	.	PUNCT
ap-2293	125	1	the	the	DET
ap-2293	125	2	scientific	scientific	ADJ
ap-2293	125	3	world	world	NOUN
ap-2293	125	4	journal	journal	PROPN
ap-2293	125	5	(	(	PUNCT
ap-2293	125	6	2014	2014	NUM
ap-2293	125	7	)	)	PUNCT
ap-2293	125	8	,	,	PUNCT
ap-2293	125	9	i	i	PROPN
ap-2293	125	10	d	d	PROPN
ap-2293	125	11	138254	138254	NUM
ap-2293	125	12	,	,	PUNCT
ap-2293	125	13	doi:10.1155/2014/13825	doi:10.1155/2014/13825	PROPN
ap-2293	126	1	[	[	X
ap-2293	126	2	7	7	NUM
ap-2293	126	3	]	]	X
ap-2293	126	4	příhoda	příhoda	NOUN
ap-2293	126	5	,	,	PUNCT
ap-2293	126	6	m.	m.	NOUN
ap-2293	126	7	,	,	PUNCT
ap-2293	126	8	molínek	molínek	NOUN
ap-2293	126	9	,	,	PUNCT
ap-2293	126	10	j.	j.	PROPN
ap-2293	126	11	,	,	PUNCT
ap-2293	126	12	pyszko	pyszko	NOUN
ap-2293	126	13	,	,	PUNCT
ap-2293	126	14	r.	r.	PROPN
ap-2293	126	15	,	,	PUNCT
ap-2293	126	16	velička	velička	NOUN
ap-2293	126	17	,	,	PUNCT
ap-2293	126	18	m.	m.	NOUN
ap-2293	126	19	,	,	PUNCT
ap-2293	126	20	vaculík	vaculík	NOUN
ap-2293	126	21	,	,	PUNCT
ap-2293	126	22	m.	m.	NOUN
ap-2293	126	23	a	a	DET
ap-2293	126	24	burda	burda	PROPN
ap-2293	126	25	,	,	PUNCT
ap-2293	126	26	j.	j.	PROPN
ap-2293	126	27	heat	heat	NOUN
ap-2293	126	28	transfer	transfer	NOUN
ap-2293	126	29	during	during	ADP
ap-2293	126	30	cooling	cool	VERB
ap-2293	126	31	of	of	ADP
ap-2293	126	32	hot	hot	ADJ
ap-2293	126	33	surfaces	surface	NOUN
ap-2293	126	34	by	by	ADP
ap-2293	126	35	water	water	NOUN
ap-2293	126	36	nozzles	nozzle	NOUN
ap-2293	126	37	.	.	PUNCT
ap-2293	127	1	metalurgija	metalurgija	NOUN
ap-2293	127	2	=	=	SYM
ap-2293	127	3	metallurgy	metallurgy	NOUN
ap-2293	127	4	.	.	PUNCT
ap-2293	128	1	2009	2009	NUM
ap-2293	128	2	,	,	PUNCT
ap-2293	128	3	48(4	48(4	NUM
ap-2293	128	4	)	)	PUNCT
ap-2293	128	5	,	,	PUNCT
ap-2293	128	6	235	235	NUM
ap-2293	128	7	-	-	SYM
ap-2293	128	8	238	238	NUM
ap-2293	128	9	.	.	NOUN
ap-2293	128	10	145	145	NUM
ap-2293	128	11	http://dx.doi.org/10.1155/2014/13825	http://dx.doi.org/10.1155/2014/13825	PROPN
ap-2293	128	12	acta	acta	PROPN
ap-2293	128	13	polytechnica	polytechnica	PROPN
ap-2293	128	14	55(3):140–145	55(3):140–145	PROPN
ap-2293	128	15	,	,	PUNCT
ap-2293	128	16	2015	2015	NUM
ap-2293	128	17	1	1	NUM
ap-2293	128	18	introduction	introduction	NOUN
ap-2293	128	19	2	2	NUM
ap-2293	128	20	heat	heat	NOUN
ap-2293	128	21	transfer	transfer	NOUN
ap-2293	128	22	in	in	ADP
ap-2293	128	23	the	the	DET
ap-2293	128	24	cooling	cool	VERB
ap-2293	128	25	panels	panel	NOUN
ap-2293	128	26	3	3	NUM
ap-2293	128	27	jn30	jn30	PROPN
ap-2293	128	28	device	device	NOUN
ap-2293	128	29	cooling	cool	VERB
ap-2293	128	30	capacity	capacity	NOUN
ap-2293	128	31	calculation	calculation	NOUN
ap-2293	128	32	4	4	NUM
ap-2293	128	33	conclusion	conclusion	NOUN
ap-2293	128	34	acknowledgements	acknowledgement	NOUN
ap-2293	128	35	references	reference	NOUN
