id	author	title	date	pages	extension	mime	words	sentence	flesch	summary	cache	txt
app01-8324	Costanzo, Matteo; Mainini, Andrea Giovanni; Iannaccone, Giuliana; Martinac, Ivo; Parsman, David	Adapting façade performances to climate change in northern Europe: Analysis of future scenarios for an office building in Stockholm	2022	7	.pdf	application/pdf	4322	263	47	Annual building energy consumption in the different years for each solution. Considering an office building, the energy performance (expressed as pri- mary energy) is limited to 80 kWh/m2Atemp, and the envelope performance (considered as Um-value, average heat transfer coefficient) is limited to 0.60 W/m2K. For what concerns the indoor comfort, specific rec- ommendations for thermal comfort in office buildings and workplaces are reported by the Swedish Work En- vironment Authority (SWEA) based on the provisions given by the EN 7730	cache/app01-8324.pdf	txt/app01-8324.txt