Electrochemical detection of chloramphenicol using gadolinium tungstate with sulphur-doped carbon nitride nanocomposite doi: http://doi.org/10.5599/admet.3015 1 ADMET & DMPK 13(6) (2025) 3015; doi: https://doi.org/10.5599/admet.3015 Open Access : ISSN : 1848-7718 https://pub.iapchem.org/ojs/index.php/admet Original scientific paper Electrochemical detection of chloramphenicol using gadolinium tungstate with sulphur-doped carbon nitride nanocomposite Trishul Alanahally Mallu1 , Gagankumar Sakleshpur Kumar2 , Santhosh Arehalli Shivamurthy3 , Nalini Seetharamaiah4 , Manoj Kumar Basavarajappa1,* and Sandeep Shadakshari2, 1Department of Environmental Engineering, SJCE, JSS Science and Technology University, Mysuru, Karnataka, India 2Department of Chemistry, SJCE, JSS Science and Technology University, Mysuru, Karnataka, India 3Department of Chemistry, NMKRV College for Women, Jayanagar, Bengaluru, Karnataka, India 4Independent Researcher, Bengaluru, Karnataka, India Corresponding Authors: E-mail: *bmanoj@sjce.ac.in; sandeep12chem@gmail.com* Received: September 13, 2025; Revised: November 10, 2025; Published: December 8, 2025 Abstract Background and purpose: Chloramphenicol (CAP) is a broad-spectrum antibiotic whose unregulated presence in pharmaceuticals and food products raises significant health concerns, underscoring the need for rapid, reliable detection methods. This study aimed to develop a sensitive and economical electrochemical sensing platform based on a novel gadolinium tungstate (Gd2(WO4)3) and sulphur-doped graphitic carbon nitride (S-g-C3N4) nanocomposite for the efficient determination of CAP. Experimental approach: The Gd2(WO4)3/S-g-C3N4 nanocomposite was synthesized via a simple co-precipitation method and characterized using XRD, XPS, EDS, and TEM to confirm structural and morphological integration. A glassy carbon electrode modified with the composite was evaluated by cyclic and linear sweep voltammetry, along with analyses of interference, repeatability, stability, and real samples in eye-drop formulations and milk. Key results: The modified electrode exhibited significantly enhanced electrocatalytic oxidation of CAP compared with bare and individually modified electrodes, demonstrating high sensitivity, good selectivity against common interferents, and strong operational stability and reproducibility. A low detection limit was achieved, and the electrode effectively quantified CAP in real matrices with satisfactory recovery. Conclusion: The findings establish the Gd2(WO4)3/S-g-C3N4 nanocomposite as an efficient sensing material, offering a reliable, stable, and cost-effective platform for routine monitoring of antibiotic residues. While minor optimization may further expand its applicability, the study advances electrochemical sensing by introducing a robust nanocomposite with improved analytical performance for CAP detection. ©2025 by the authors. This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/). Keywords Electrochemical sensor; antibiotic detection; cyclic voltammetry; nanocomposite; pharmaceutical analysis. Introduction Chloramphenicol (CAP), a widely known antibiotic with broad-spectrum antibacterial activity, has been used extensively to treat a variety of infectious diseases in humans and animals [1-3]. However, in recent years, CAP has also been known to take a toll on human health and has side effects that cause serious illness like aplastic anaemia [4], fatal bone marrow depression [5], agranulocytosis and gray baby syndrome [6,7]. In these lines, a few countries (including China, North America and Canada) have constrained the usage of CAP while European http://doi.org/10.5599/admet.3015 https://doi.org/10.5599/admet.3015 https://pub.iapchem.org/ojs/index.php/admet mailto:bmanoj@sjce.ac.in mailto:sandeep12chem@gmail.com http://creativecommons.org/licenses/by/4.0/ https://orcid.org/0000-0002-5858-7313 https://orcid.org/0009-0000-1884-4605 https://orcid.org/0000-0002-6606-3026 https://orcid.org/0000-0001-5376-8396 https://orcid.org/0000-0003-3141-5084 https://orcid.org/0000-0003-4342-4623 13T. Alanahally Mallu et al. ADMET & DMPK 13(6) (2025) 3015 2 nations have set a maximum trace of CAP limit of 0.3 g kg-1 for food-safety control activities [8]. Nevertheless, it is still widely used in developing countries due to its efficiency, affordability, and availability. As a result, it is a necessary task to determine the concentration of CAP in the sample by using efficient, low-cost, rapid analytical techniques and examine their applicability in human fluids, food and drug samples [9]. Numerous microbiological and analytical techniques are presently available for CAP determination, in particular, liquid chromatography-tandem mass spectrometry (LC-MS/MS), gas chromatography-mass spectrometry (GC-MS), gas chromatography with electron capture detection (GC-ECD), radioimmunoassay, enzyme immunoassay [10], and capillary electrophoresis [11]. Although it is reliable and accurate, there are certain limitations related to its cost and complex operational procedures, which may limit the application of these techniques [12]. Hence, to overcome these drawbacks, the electrochemical technique has been widely used. The advantage of the electrochemical method includes very high sensitivity, rapid analysis, ease of use and low cost [13]. Recently, rare-earth minerals and their derivatives have emerged as the most promising choice for a variety of electrochemical sensors due to their superior intrinsic properties, such as high electrical conductivity and excellent magnetic, optical, and chemical properties [14]. Tungstates of rare earth metals like, Gd2(WO4)3, La2(WO4)3, Sm2(WO4)3, Ce2(WO4)3, Tm2(WO4)3 etc. have been thoroughly investigated over the previous years in the applications of sensors owing to low toxicity and high surface coverage area, high thermal and chemical stability [15-17]. These research studies suggest that gadolinium tungstate could be a promising candidate in the construction of an electrochemical sensor. Similarly, it has been documented in the literature that altering electrodes with noble metal-free substances like graphene and graphitic carbon nitride (g-C3N4) enhances the electrode's catalytic perfor- mance. In addition to that, g-C3N4-based materials can be easily synthesised using low-cost precursors [18]. Furthermore, in a wide assortment of electrochemical sensing applications, g-C3N4 has been efficiently applied for the determination of biomolecules, phenolic compounds and toxic metal ions, attributing to its polymeric nature, making it a great fit for electrocatalytic materials [19]. Recently, in the field of carbon nanomaterials, doping g-C3N4 with heteroatoms like phosphorus, oxygen, boron, halogen, and sulphur has received a lot of attention. It is noteworthy that, especially the sulphur-doped bulk g-C3N4, even at modest concentrations, can be effectively tuned by leveraging its intrinsic properties, such as a high surface area, excellent chemical properties, and extraordinary electronic properties. Both Gd2(WO4)3 and S-g-C3N4 are known for their unique electronic structures and excellent catalytic pro- perties. When combined, these materials form a heterojunction interface between two semiconductors, which facilitates efficient charge separation and transfer. Previous studies on gadolinium-modified g-C3N4 and tungsten oxide (WO3) composites have demonstrated the formation of an S-scheme heterojunction, a mecha- nism that enhances redox efficiency and stability. This suggests that a similar interaction is likely to occur betwe- en Gd2(WO4)3 and S-g-C3N4. Moreover, composites of tungstate and doped g-C3N4 have shown remarkable potential in environmental remediation and energy-related applications such as photocatalytic degradation of organic pollutants, hydrogen evolution from water splitting, air purification, and antibacterial activity [20]. Moti- vated by these promising properties, we aimed to extend the application of this heterostructured nanocomposite to the field of electrochemical sensing. The synergistic effect between Gd2(WO4)3 and [S-g-C3N4] is expected to enhance electron transfer kinetics and improve the sensitivity and selectivity of CAP detection. In the present research work, Gd2(WO4)3 was synthesized using a co-precipitation approach and S-g-C3N4 was prepared by the combustion process. The resultant Gd2(WO4)3/S-g-C3N4 nanocomposite was characterized using spectrophotometry and voltammetry techniques. Then, the nanocomposite was explored in the construc- tion of an electrochemical sensor by adsorbing it onto a GCE for the reduction of CAP. The modified electrode ADMET & DMPK 13(6) (2025) 3015 Electrochemical detection of chloramphenicol using Gd₂(WO₄)₃ doi: https://doi.org/10.5599/admet.3015 3 exhibited an excellent linear range and a low limit of detection. Furthermore, the reproducibility, storage stability, and practicability were investigated. Experimental Chemicals and reagents Gadolinium nitrate hexahydrate (Gd(NO3)3·6H2O), sodium tungstate dihydrate (Na2WO4·2H2O), melamine, and thiourea were procured from Sigma-Aldrich (Bangalore, India) and used without further purification. potassium ferricyanide (K3Fe(CN)₆), potassium ferrocyanide (K4Fe(CN)₆), potassium chloride (KCl), and phos- phate-buffered saline (PBS, pH 7.0) were obtained from Merck (Mumbai, India). CAP standard solution was purchased from Himedia Laboratories Pvt. Ltd. (Mumbai, India). All aqueous solutions were prepared using double-distilled water. Electrochemical experiments, including cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), were performed using a CHI 6041E electrochemical workstation (CH Instru- ments, USA) with a conventional three-electrode system comprising a glassy carbon working electrode (3 mm diameter), a platinum wire counter electrode, and an Ag/AgCl (3 M KCl) reference electrode. Apparatus The morphological structure and elemental mapping of the as-synthesised nanocomposite were examined using an EDX-equipped TEM (JEM 2100F; JEOL Ltd., Japan). The chemical composition and structural crystallinity were examined using XPS (JPS-9030, JEOL ltd., Japan) and XRD (X′ Pert3 Powder, Malvern Panalytical/UK) techniques. Electrochemical measurements were carried out with CHI 6041E electrochemical workstation, using a conventional three-electrode system where a saturated calomel electrode, a glassy carbon electrode and a platinum electrode were used as reference, working and auxiliary electrodes, respectively. A glassy carbon electrode (GCE, 3 mm diameter) modified with the synthesized nanocomposite served as the working electrode, a platinum wire as the counter electrode, and an Ag/AgCl (3 M KCl) electrode as the reference. All experiments were performed in 0.1 M phosphate-buffered saline (PBS, pH 7.0) at room temperature (25±2 °C). Cyclic voltammetry (CV) was conducted within a potential range of -0.4 V to +0.2 V at a scan rate of 50 mV s-1. The current response was measured at different concentrations of the target analyte (50-250 μM) under identical conditions. Electrochemical impedance spectroscopy (EIS) was performed at the open-circuit potential using a 5 mV AC amplitude over a frequency range of 0.01 Hz to 100 kHz. Nyquist plots were fitted with an equivalent circuit to determine the charge-transfer resistance (Rct) and evaluate electron-transfer characteristics. Synthesis of Gd2(WO4)3 and fabrication of Gd2(WO4)3/S-g-C3N4 nanocomposite Gadolinium tungstate (Gd2(WO4)3) was synthesized using the co-precipitation method. 200 mL of distilled water was used to dissolve 0.1 M Gd (NO3)3 and 0.2 M Na2WO4. The morphological influence was improved by adding 0.5 M urea (0.6 g in 20 mL) to the solution and stirring continuously for 1 hour at room temperature, resulting in a white precipitate. Finally, the product was washed and thoroughly cleaned with ethanol, followed by deionised water. The precipitate was then dried at 50 °C overnight. The sample was then calcinated at 800 °C for 4 hours at a rate of 5 °C/min (Scheme 1A). Besides this, S-g-C3N4 was synthesized by pyrolyzing 10 g of thiourea (CH4N2S) in a muffle furnace at 540 °C for 5 h. A simple grinding process was then employed to create Gd2(WO4)3/S-g-C3N4 composite. Consequently, equal parts of Gd2(WO4)3 and S-g-C3 N4 (1:1 weight ratio) were mixed and crushed to a fine paste in a mortar (Scheme 1B). https://doi.org/10.5599/admet.3015 13T. Alanahally Mallu et al. ADMET & DMPK 13(6) (2025) 3015 4 Scheme 1. (A) Graphical representation of synthesis of Gd2(WO4)3/S-g-C3N4 composite and (B) fabrication of electrode Fabrication of Gd2(WO4)3/S-g-C3N4 modified glassy carbon electrode Prior to the modification, the electrode surface was first washed with deionised water and air-dried. For fabrication of the CAP electrochemical sensor, a 1:1 mixture of Gd2(WO4)3/S-g-C3N4 nanocomposite was first dispersed in 1 mL of deionised water and 6μL of this dispersion was uniformly spread over the GCE surface. The so-modified GCE was dried at room temperature (Scheme 1B) and subsequently, the electrochemical performance of the electrode towards the CAP reduction was investigated. Results and discussion Characterization of synthesized Gd2(WO4)3/S-g-C3N4 nanoparticles X-ray powder diffraction analysis (XRD), which reveals the crystallinity and purity of compounds, was used to examine the synthesised nanocomposite. As can be witnessed from the results obtained in Figure 1A, XRD confirmed the crystal structure of the Gd2(WO4)3 and the sharp scattering peaks could be well indexed to the tetragonal phase (JCPDS No. 25-0829) of pure Gd2(WO4)3 [20]. The 18.73, 25.11, 27.94, 29.50, 31.49, 34.47 and 47.22° are the diffraction peaks and (111), (112), (221), (023), (040), (204) and (242) are the crystal lattices, respectively. Similarly, S-g-C3N4 exhibited a characteristic XRD peak, which is in excellent agreement with the literature [21,22]. As shown in the graph for the composite of Gd2(WO4)3 and S-g-C3N4, the crystalline peaks are well matched. The morphological structure of Gd2(WO4)3/S-g-C3N4 nanocomposite was examined by TEM. As shown in Figure 1B, the S-g-C3N4 had a nanosheet-like structure and had a few black patches on or between the surfaces, indicating that elemental sulphur is spread randomly on the surface of the GCN nanosheets. The surface morphology of Gd2(WO4)3 was also recorded as illustrated in Figure 1C, which clearly showed the ADMET & DMPK 13(6) (2025) 3015 Electrochemical detection of chloramphenicol using Gd₂(WO₄)₃ doi: https://doi.org/10.5599/admet.3015 5 appearance of a dicot seed-like structure of Gd2(WO4)3 [23,24]. Furthermore, the composite's overall morphology indicates a uniform distribution of materials, free of impurities, and a smooth, flawless surface. This validates the successful synthesis of a nanocomposite. Figure 1. (A) XRD Patterns of Gd2(WO4)3, S-g-C3N4 and Gd2(WO4)3/S-g-C3N4, (B) and (C) TEM images of Gd2(WO4)3/S-g-C3N4, (D) SEAD pattern of Gd2(WO4)3/S-g-C3N4 and (E) EDX spectrum of nanocomposite with corresponding content, wt.% The SAED pattern of the Gd2(WO4)3/S-g-C3N4 nanocomposite was captured as depicted in Figure 1D. It displays a pattern of spots that can be related to the planes of (112) and (221), which correlates with the XRD patterns. The elemental distribution was carried out through the EDS that confirmed the presence of all the elements which were used during the synthesis, i.e. nitrogen (22.7 %) oxygen (19.1 %) carbon (48.8 %) gadolinium (3.84 %), tungstate (5.43 %) and sulphur (0.0784 %) suggesting the successful synthesis Gd2(WO4)3/S-g-C3N4 nanocomposite without any notable contaminants. The XPS spectra of the as-synthesised nanocomposite Gd2(WO4)3/S-g-C3N4 were evaluated to determine the chemical state and elemental composition of materials, as illustrated in Figure 2. In the spectral peaks of C 1s, several peaks are prominent that correspond to several carbon functional groups, including C-C/C-H, C-O, C=O, and COOH. These peaks' relative intensities range from 282 to 290 eV and the locations reveal details about the chemistry of the surface. Whereas, in the N1s XPS spectrum, unique peaks of different nitrogen species, including amine (N-H), amide (C-N), and nitro (N=O) groups, are exhibited. Likewise, peaks from several oxygen species, including metal oxide (M-O), hydroxyl (O-H), and carbonyl (C=O) groups, may be observed in the O 1s XPS spectrum in the 528.9-536.7 eV range. The interpretation of oxidation state is aided by these peaks. The XPS spectra of the S 2p peaks at 141.4 and 147.6 eV are associated with sulphur species, including thiol (S-H), sulphide (S-S), and sulphate (S-O) groups. The core-level peaks corresponding to the Gd and W elements were revealed by the XPS spectra for the Gd4d (141.52 and 147.6 eV) and W4f (33.94 and 36 eV) elements, respectively. These spectra made it possible to identify the oxidation states and chemical surroundings of Gd and W atoms, which are essential for comprehending how they impact the material's distinctive characteristics. https://doi.org/10.5599/admet.3015 13T. Alanahally Mallu et al. ADMET & DMPK 13(6) (2025) 3015 6 Figure 2. XPS spectra of Gd2(WO4)3/S-g-C3N4 nanocomposite (A) the survey scan, (B) C 1s, (C) Gd 4D, (D)N 1s, (E) O 1s, (F) S 2p and (G) W 4f Electrochemical characterization of Gd2(WO4)3/S-g-C3N4 modified glassy carbon electrode Surface characterization of the modified electrode using cyclic voltammetry Figure 3A shows the voltametric response of Gd2(WO4)3/S-g-C3N4, Gd2(WO4)3, S-g-C3N4 and unmodified bare GCE in 5 μM of [Fe (CN)6]3-/4- as redox probe in the presence of 0.1 M KCl. Apparently, the bare GCE shows a weak redox peak response with a peak current of 3.06 µA, compared with other modifications such as S-g-C3N4/GCE and Gd2(WO4)3/GCE, which showed peak responses of 3.53 and 3.86 µA, respectively. Compared with the Gd2(WO4)3/S-g-C3N4/GCE revealed a very high current response of 4.14 µA. This increase is significantly higher than that for the other modified electrodes. These observations demonstrate the synergistic effects of the nanocomposite, which contribute to its large surface-to-volume ratio and enhanced performance. The electrochemical sensing mechanism of CAP at the Gd2(WO4)3/S-g-C3N4 modified electrode is primarily governed by the synergistic interaction between Gd2(WO4)3 and sulphur-doped graphitic carbon nitride. The incorporation of Gd2(WO4)3 onto the S-g-C3N4 matrix increases the density of catalytically active sites and facilitates faster charge transfer between the electrode surface and the electrolyte. sulphur doping introduces defect sites and enhances the electrical conductivity of g-C3N4, thereby promoting electron mobility and improving the adsorption affinity of CAP molecules. ADMET & DMPK 13(6) (2025) 3015 Electrochemical detection of chloramphenicol using Gd₂(WO₄)₃ doi: https://doi.org/10.5599/admet.3015 7 Potential, V CCAP / M Figure 3. (A) Cyclic voltammograms of bare GCE, S-g-C3N4/GCE, Gd2(WO4)3/GCE, and Gd2(WO4)3/S-g-C3N4/GCE electrodes recorded in 5 mM [Fe(CN)₆]³⁻/⁴⁻ containing 0.1 M KCl at a scan rate of 50 mV s⁻¹; (B) Nyquist plots (EIS) of the corresponding electrodes in 5 mM [Fe(CN)₆]³⁻/⁴⁻ with 0.1 M KCl, recorded over a frequency range of 0.1 Hz to 100 kHz at an amplitude of 10 mV; (C) Cyclic voltammograms of individual electrodes (bare GCE, S-g-C3N4/GCE, Gd2(WO4)3/GCE, and Gd2(WO4)3/S-g-C3N4/GCE) toward 100 μM CAP in 0.1 M PBS (pH 7.0);(D) Optimization of Gd2(WO4)3/S-g-C3N4 loading on GCE and corresponding current responses toward 100 μM CAP; (E) Cyclic voltammograms of Gd2(WO4)3/S-g-C3N4/GCE at varying CAP concentrations (50 to 250 μM) in 0.1 M PBS (pH 7.0); (F) Calibration plots showing the linear relationship between peak current and CAP concentration derived from Figure 3E Upon applying a suitable potential, the nitro group (-NO2) of CAP undergoes a two-step, four-electron reduction process. In the first step, CAP is reduced to the corresponding hydroxylamine derivative (-NHOH), followed by its further reduction to the amine (-NH2) form. This reduction process is facilitated by the excellent redox mediation properties of Gd3+/Gd2+ centres present in Gd2(WO4)3 and the strong π-π interaction between the aromatic ring of CAP and the conjugated g-C3N4 framework. The presence of sulphur atoms within the g-C3N4 lattice increases the local electron density near the conduction band, thereby enhancing electron transfer kinetics during the CAP reduction. https://doi.org/10.5599/admet.3015 13T. Alanahally Mallu et al. ADMET & DMPK 13(6) (2025) 3015 8 Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) studies further support this mechanism. A significant decrease in charge-transfer resistance and an increased redox current response was observed for the Gd2(WO4)3/S-g-C3N4 modified electrode compared to pristine g-C3N4 or bare GCE, confirming the enhanced electrocatalytic efficiency of the composite. The synergistic effect between Gd2(WO4)3 and S-g-C3N4 results in improved sensitivity, lower detection limits, and superior stability of the sensor toward CAP detection. Figure 4 illustrates the synergistic role of Gd2(WO4)3 and sulphur-doped g-C3N4 in facilitating the electro- chemical reduction of CAP. The S-g-C3N4 nanosheets provide a high surface area with abundant active sites and improved conductivity, owing to sulphur-induced defects, enabling efficient adsorption of CAP molecules via π-π stacking interactions. The Gd2(WO4)3 nanoparticles anchored on the S-g-C3N4 surface act as redox mediators, accelerating electron transfer between CAP and the electrode interface. The nitro group (-NO2) of CAP is reduced sequentially to the hydroxylamine (-NHOH) and amine (-NH2) intermediates via a two-step, four-electron transfer process. This synergistic interplay between Gd2(WO4)3 and S-g-C3N4 significantly enhances the current response, resulting in high sensitivity and selectivity for CAP detection. Figure 4. Proposed electrochemical sensing mechanism of CAP at the Gd2(WO4)3/S-g-C3N4 modified electrode Electrochemical impedance spectroscopy EIS is a highly sensitive technique for evaluating electrode surface characteristics during successive modification steps. In this study, EIS measurements were performed for both modified and unmodified electro- des in the presence of 5 mM [Fe(CN)6]3-/4- as a redox probe in 0.1 M KCl. The bare GCE displayed a high charge transfer resistance (R’) of approximately 1325 Ω, indicating sluggish electron transfer. Upon modification with S-g-C3N4, the Rct decreased to 1038 Ω, while the Gd2(WO4)3-modified electrode exhibited a further reduction to 789 Ω. Notably, the Gd2(WO4)3/S-g-C3N4-modified GCE showed a much lower Rct of 565 Ω, confirming the syner- gistic interaction between Gd2(WO4)3 and S-g-C3N4. This enhanced conductivity arises from improved charge- transfer pathways, thereby increasing the electroactive surface area provided by the nanocomposite film. EIS was performed at the open-circuit potential (OCP) after the electrode had equilibrated for 300 s. The AC perturbation amplitude was 5 mV (rms) and the frequency range spanned 100 kHz to 0.01 Hz (logarithmic frequency sampling). Each spectrum represents the average of three independent measurements (I = 3). Nyquist plots show the real part Z′ / Ω on the x-axis and the negative imaginary part -Z′′ / Ω on the y-axis; in the revised figures, the x- and y-axes use the same scale to avoid visual distortion of the semicircle. The charge-transfer resistance (Rct) was obtained by fitting the Nyquist spectra to the equivalent circuit model Rs + Rct CPE + WR (where Rs is the solution resistance, CPE is the constant phase element representing the double-layer behaviour, and W is the Warburg element for diffusion). Curve-fitting was performed using Z View (or the CHI software fitting routine) [25], and the reported Rct values correspond to the fitted semicircle diameter (difference between the high-frequency and low-frequency intercepts on the real axis). The fitting quality was assessed by the chi-squared statistic (χ² < 10-3) and by visual agreement between the experimental ADMET & DMPK 13(6) (2025) 3015 Electrochemical detection of chloramphenicol using Gd₂(WO₄)₃ doi: https://doi.org/10.5599/admet.3015 9 and fitted data. Note that Rct is reported in Ω; conductance (G) is the reciprocal (G = 1/R) and was not used in the present analysis. The electroactive surface area (A) was calculated using the Randles-Ševčik equation: Iₚ = (2.69×10⁵)n3/2AD1/2C ½ (1) where Iₚ / A is the peak current, n = 1, D = 7.6×10-6 cm2 s-1, C = 5 mM and  = 0.05 V s-1 [21]. The calculated surface areas were 0.031 cm2 for bare GCE, 0.045 cm2 for S-g-C3N4/GCE, 0.052 cm2 for Gd2(WO4)3/GCE, and 0.071 cm2 for Gd2(WO4)3/S-g-C3N4/GCE. The increase in electroactive surface area clearly demonstrates enhanced charge transfer and a higher density of catalytic sites on the composite-modified electrode, contributing to its improved electrochemical performance. Electrochemical activity towards CAP with individual materials. The electrochemical behaviour of the sensor towards CAP detection was examined by CV in PBS (0.1 M, pH 7.0) in the presence of 100 µM CAP (Figure 3C). Compared to the responses of bare GCE, the response obtained for S-g-C3N4/GCE, Gd2(WO4)3/GCE as well as Gd2(WO4)3/S-g-C3N4/GCE electrode was 0.5, 0.59, 0.77 and 0.89 µA, respectively. Likewise, the current response recorded for Gd2(WO4)3/S-g-C3N4/GCE was higher and actively good. This demonstrated the improved performance of the electrode towards CAP owing to the high surface area and excellent electron conductivity of the synergistic nanocomposite. Optimization of electrode parameters Different volumes of Gd2(WO4)3:S-g-C3N4 nanocomposite prepared using an equal weight ratio, i.e. 2.5:2.5 of 5 mg of the nanocomposite dispersed in 1 ml of water, were explored for the construction of the sensor to opti- mise the electrode fabrication protocol. The nanocomposite dispersion was then drop-casted on the GCE elec- trode surface in varying volumes like 2, 4, 6, 8 and 10 μL. Following this, these electrodes were examined for the electrochemical determination of 100 μL of CAP under standard conditions. As shown in Figure 3D, the current response for CAP was excellent and an enhanced peak was obtained in the case of 6 μL of the nanocomposite. Hence, for our studies throughout this work, 6 μL was selected as a standard volume in the fabrication procedure. Electrochemical activity of Gd2(WO4)3/S-g-C3N4/GCE towards CAP Electrochemical detection of CAP through cyclic voltammetry by increasing CAP concentration CAP detection was performed using CV techniques. The study was conducted by increasing the concentration range of CAP from 50 to 250 μM in the potential range of -0.4 to 0.2 V at a scan rate () of 50 mV s-1 in 0.1 M PBS (pH 7.0). The outcome is shown in Figure 3E, and the calibration plot for CAP is shown in the inset. It is evident that an increase in CAP results in higher anodic and cathodic currents. Furthermore, Figure 3F illustrates how the concentration of CAP and the current are interdependent with satisfactory regression coefficient values of R2= 0.99342 and R2 = 0.96172 for Ipa and Ica, respectively. Effect of pH pH greatly affects the performance of any electrochemical sensor. To achieve a proper electrochemical response, it is necessary to study the effect of pH on the modified electrochemical sensor. The impact of pH on the Gd2(WO4)3/S-g-C3N4 nanocomposite was examined at different pH levels of 3, 5, 7, 9 and 11 in the presence of 100 μL of CAP. As shown in Figure 5A, the CAP redox peak increases with increasing pH from 3 to 7. However, further increases in pH beyond 7 result in a decrease in the peak current, as shown in the bar graph (Figure 5B). The highest peak current is at pH 7. The inset bar graph represents the peak current responses to different pH solutions. To increase the electrochemical sensor's sensitivity, pH 7 is used for all experiments. https://doi.org/10.5599/admet.3015 13T. Alanahally Mallu et al. ADMET & DMPK 13(6) (2025) 3015 10 Effect of scan rate The relationship between scan rate and redox current was investigated to understand the electron-transport process from the bulk solution to the electrode surface. At scan rates ranging from 20 to 240 mV s-1, CV was recorded for 100 mM CAP in 0.1 M PBS buffer. The results are shown in Figure 5C. Figure 5. (A) CV response for CAP at different pH (3 to 11); (B) bar graph of pH vs current; (C) effect of scan rate from 20 to 200 mV s-1 in presence of 100 mM of CAP in 0.1 M PBS buffer solution (D) linear plot of scan rate vs. peak current; (E) linear plot of square root of scan rate vs. current; (F) LSV measurements conducted with gradual increasing concentration of CAP from 50 to 800 µM. (G) Linear plot of LSV showing CAP concentrations plotted with current  1/2 / mV1/2 s-1/2  / mV s-1 ADMET & DMPK 13(6) (2025) 3015 Electrochemical detection of chloramphenicol using Gd₂(WO₄)₃ doi: https://doi.org/10.5599/admet.3015 11 The anodic and cathodic peak currents were found to increase as the scan rate was gradually increased. Figure 5D displays the corresponding linear plot of the anodic and cathodic peak currents versus the scan rates. In addition, the square root of the scan rate was also plotted and is shown in Figure 5E. The obtained peak currents followed the linear relationship Ipa = R2 = 0.9962 and Ica = R2 = 0.9935 with the scan rates in the investigated range. The calibration plot was drawn to determine the linearity of the response, and from the obtained result, we can clearly observe linearity based on the R2 Value, which is almost 1. From these plots, we can confirm that the electrode process is adsorption-controlled. Optimizing voltammetric parameters is crucial for achieving the best analytical performance of the modified electrode. Parameters such as pH, scan rate, and nanocomposite loading volume were systema- tically varied. The highest current response was obtained at pH 7.0, confirming that near-neutral conditions favour efficient electron transfer for CAP reduction. Similarly, the scan rate study (20 to 240 mV s-1) revealed a linear increase in current with the square root of the scan rate, indicating an adsorption-controlled process. Among various loading volumes, 6 µL of Gd2(WO4)3/S-g-C3N4 dispersion yielded the maximum current response; hence, these optimized parameters were adopted for subsequent analyses. Electrochemical detection of CAP by using linear sweep voltammetry To further validate the enhanced electrochemical performance of the proposed electrode, linear sweep voltammetry (LSV) investigation was conducted. the sensing capabilities of the prepared Gd2(WO4)3/S-g-C3N4 electrocatalyst towards CAP quantitation in the presence of varying concentrations of CAP in 0.1 M PBS solution at a constant scan rate of 50 mV s-1 were evaluated. Figure 5F shows that the oxidation current gradually increases with the addition of CAP, one at a time, into the reaction medium, indicating the electrocatalyst's sensing effectiveness. Additionally, a linear relationship between peak current and CAP concentration was observed over the entire range of 50-800 µM (Figure 5G), with a calibration equation R2 = 0.98766. The sensitivity of the proposed sensor was calculated by dividing the slope value by the electrode surface area (0.071 cm2), Equation (2): LOD = 3 / m (2) where m is the slope of the current vs. concentration curve and  is the standard deviation of three measure- ments of blank (0.1 M PBS electrolyte without analyte). The LOD value determined using Equation (2) was found to be 49.143 nM. Similarly, the limit of quantification (LOQ) calculated using Equation (3) was found to be 163.811 nM. LOQ = 10 / 3 (3) To validate the overall performance of the electrode, the results were compared with previously published literature and presented in Table 1. Table 1: Comparison of different electrochemical sensors for the determination of CAP No Technique Material LOD, µM Reference 1 DPV Cl-RGO/GCE 1.0 [2] 2 DPV CoMoO4/GCE 0.014 [26] 3 SWV EPC/GCE 2.9* [27] 4 DPV Co-Fe3O4 NS/GO 0.00104 [28] 5 SWV Fe3O4-CMC@Au 0.07 [29] 6 LSV rGO-Pt-Pd NCs 0.1 [30] 7 DPV Co3O4@rgo 1.16 [31] 8 DPV MoS2-IL/GO 0.047 [32] 9 DPV Fe3O4/GCE 0.09 [33] 10 LSV Gd2(WO4)3/S-g-C3N4/GCE 0.0491 This work *nmol L-1 https://doi.org/10.5599/admet.3015 13T. Alanahally Mallu et al. ADMET & DMPK 13(6) (2025) 3015 12 Selectivity A selectivity test was performed to evaluate the electrocatalytic performance of the developed electrochemical sensor for the selective determination of CAP, as shown in Figure 6A. In this application test, the interferants such as ascorbic acid, glucose, NO2, sucrose, Cu2+ and Pb2- were taken and individually added along with 3 % higher concentration of CAP under optimized conditions at the scan rate of 50 mV s-1. The results obtained confirmed that the nanocomposite-modified GCE was successful in selectively detecting CAP. This can be correlated with the LSV technique as the potentials obtained towards CAP determination. Reproducibility, cyclic stability, and storage stability of the sensor The proposed sensor's practical viability, including reproducibility, cycle stability, and storage stability, was assessed using the CV approach in the presence of 100 µM CAP in 0.1 M PBS (pH 7). To test the reproducibility, five different fabricated using a same protocol, wherein the Gd2(WO4)3/S-g-C3N4 nanocom- posite was drop casted on GCE electrodes were used for CAP determination (Figure. 6C). The extraordinary repeatability of Gd2(WO4)3/S-g-C3N4/GCE is illustrated by the fact that the redox peaks of five different electrodes differed only by less than 5 % of the actual electrode. Figure 6. (A) LSV plots for the study of interferents in the presence of ascorbic acid, glucose, nitrogen dioxide, sucrose, copper, and lead along with CAP; (B) bar graph showing the current response of interferents in presence of CAP; (C) CV plots for reproducibility analysis of 6 electrodes; (D) CV plots for study of repeatability- cyclic stability with 30 cycles; (E) storage stability of the sensor from day 1 to day 25 ADMET & DMPK 13(6) (2025) 3015 Electrochemical detection of chloramphenicol using Gd₂(WO₄)₃ doi: https://doi.org/10.5599/admet.3015 13 Similarly, Figure 6D illustrates the stability of the modified electrodes, assessed using 30 repetitive potential cycles. The cyclic voltammograms could be repeated without significantly altering the background current response. It is observed that after 30 cycles, the modified electrode retained excellent stability, with only a negligible decrease in current compared to the second cycle and a minor change from the first cycle, which can be readily neglected. To carry out the stability studies, modified Gd2(WO4)3/S-g-C3N4/GCE electrodes were used to determine CAP rinsed with water, and then dried in an ambient atmosphere and stored at 4 °C when not in use. This process of analysis, rinsing and storing was carried out for up to 25 days. The results obtained were then compared with those of a newly fabricated sensor. As shown in Figure 6E, peak current readings taken for electrodes with a 1 M concentration of CAP were nearly a perfect match for readings taken for a newly prepared electrode. Thus, we can conclude that the developed sensor showed good relative stability over time as the peak current response was 100, 95.45, 86.36, 77.21, 68.18 and 54.54 % for 1, 5, 10, 15, 20 and 25 days, respectively. Real sample analysis The quantitative analysis of CAP in real samples was done using the LSV method to evaluate its practical applicability. To perform this study, the CAP concentration in a commercially available Eye drop and a milk sample was first determined using the developed electrode. As a result, it was possible to assess how well the new electrode performed while analysing the actual sample data. The outcomes of the recovery trials are shown in Table 2 and demonstrate outstanding recovery and sensor validity in real-world applications. Table 2: Detection of CAP in real samples Samples Amount, M Recovery, % RSD, % Added Found Milk 25 24.8 99.2 2.7 50 49.2 98.8 2.2 Eye drops 25 24.9 99.6 3.9 50 49.95 99.9 2.85 Conclusion Here, we use a simple and efficient co-precipitation technique to prepare a Gd2(WO4)3/S-g-C3N4 nanocomposite, which has potential for a wide range of electrochemical sensing applications. Firstly, Gd2(WO4)3/S-g-C3N4 is embellished on the GCE in its as-synthesised form. To characterise the Gd2(WO4)3/S-g-C3N4 nanocomposite, a variety of spectrophotometric methods like TEM, EDX with elemental mapping, XPS and XRD are used. Subsequently, the electrochemical properties of the Gd2(WO4)3/S-g-C3N4 modified GCE towards the determination of CAP were investigated using CV, EIS and LSV. The LSV revealed interesting results with a very low LOD of 49.143 nM for CAP determination. The synergistic effects of Gd2(WO4)3/S-g-C3N4 contributed to the excellent electroanalytical characteristics of the proposed sensor. The modified sensor also showed good cyclic stability, storage stability and reproducibility along with an excellent anti-interfering activity. Funding: This project has not received any funding. Conflict of interest: The authors declare that they have no conflicts of interest. References [1] T. Sun, H. Pan, Y. Mei, P. Zhang, D. Zeng, X. Liu, S. Rong, D. Chang. Electrochemical sensor sensitive detection of chloramphenicol based on ionic-liquid-assisted synthesis of de-layered molybdenum disulfide/graphene oxide nanocomposites. Journal of Applied Electrochemistry 49(3) (2019) 261-270. https://doi.org/10.1007/s10800-018-1271-6 https://doi.org/10.5599/admet.3015 https://doi.org/10.1007/s10800-018-1271-6 13T. Alanahally Mallu et al. ADMET & DMPK 13(6) (2025) 3015 14 [2] K.P. Wang, Y.C. Zhang, X. Zhang, L. Shen.Green preparation of chlorine-doped graphene and its application in electrochemical sensor for chloramphenicol detection. SN Applied Sciences 1(2) (2019) 157. https://doi.org/10.1007/s42452-019-0174-4 [3] S. Gao, Y. Zhang, Z. Yang, T. Fei, S. Liu, T. Zhang. Electrochemical chloramphenicol sensors based on trace MoS₂ modified carbon nanomaterials: Insight into carbon supports. Journal of Alloys and Compounds 872 (2021) 159687. https://doi.org/10.1016/j.jallcom.2021.159687 [4] N. Sebastian, W.C. Yu, D. Balram. Electrochemical detection of an antibiotic drug chloramphenicol based on a graphene oxide/hierarchical zinc oxide nanocomposite. Inorganic Chemistry Frontiers 6(1) (2019) 82-93. https://doi.org/10.1039/C8QI01000E [5] N. A. Shad, S. Z. Bajwa, N. Amin, A. Taj, S. Hameed, Y. Khan, Z. Dai, C. Cao, W. S. Khan. Solution growth of 1D zinc tungstate (ZnWO4) nanowires; design, morphology, and electrochemical sensor fabrication for selective detection of chloramphenicol. Journal of Hazardous Materials 367 (2019) 205-214. https://doi.org/10.1016/j.jhazmat.2018.12.072 [6] M. Yadav, V. Ganesan, R. Gupta, D.K. Yadav, P.K. Sonkar. Cobalt oxide nanocrystals anchored on graphene sheets for electrochemical determination of chloramphenicol. Microchemical Journal 146 (2019) 881-887. https://doi.org/10.1016/j.microc.2019.02.025 [7] S.V. Selvi, N. Nataraj. The electro-catalytic activity of nanosphere strontium doped zinc oxide with rGO layers screen-printed carbon electrode for the sensing of chloramphenicol. Microchemical Journal 159 (2020) 105580. https://doi.org/10.1016/j.microc.2020.105580. [8] G. Jaysiva, S. Manavalan, S.M. Chen, P. Veerakumar, M. Keerthi, H.S. Tu. MoN nanorod/sulfur-doped graphitic carbon nitride for electrochemical determination of chloramphenicol. ACS Sustainable Chemistry & Engineering 8(30) (2020) 11088-11098. https://doi.org/10.1021/acssuschemeng.0c00502 [9] C. Karuppiah, K. Venkatesh, L.F. Hsu, P. Arunachalam, C.C. Yang, S.K. Ramaraj, R.J. Ramalingam, S. Aro- kiyaraj, H.A. Al-Lohedan. An improving aqueous dispersion of polydopamine functionalized vapor grown carbon fiber for the effective sensing electrode fabrication to chloramphenicol drug detection in food samples. Microchemical Journal 170 (2021) 106675. https://doi.org/10.1016/j.microc.2021.106675 [10] S. Akter Mou, R. Islam, M. Shoeb, N. Nahar. Determination of chloramphenicol in meat samples using liquid chromatography-tandem mass spectrometry. Food Science & Nutrition 9(10) (2021) 5670-5675. https://doi.org/10.1002/fsn3.2530 [11] A.E. Vilian, S.Y. Oh, M. Rethinasabapathy, R. Umapathi, S.K. Hwang, C.W. Oh, B. Park, Y.S. Huh, Y.K. Han. Improved conductivity of flower-like MnWO₄ on defect engineered graphitic carbon nitride as an efficient electrocatalyst for ultrasensitive sensing of chloramphenicol. Journal of Hazardous Materials 399 (2020) 122868. https://doi.org/10.1016/j.jhazmat.2020.122868 [12] Y. Baikeli, X. Mamat, F. He, X. Xin, Y. Li, H. A. Aisa, G. Hu. Electrochemical determination of chloramphenicol and metronidazole by using a glassy carbon electrode modified with iron, nitrogen co-doped nanoporous carbon derived from a metal-organic framework (type Fe/ZIF-8). Ecotoxicology and Environmental Safety 204 (2020) 111066. https://doi.org/10.1016/j.ecoenv.2020.111066 [13] Y.M. Xia, W. Zhang, M. Y. Li, M. Xia, L. J. Zou, W. W. Gao. Effective electrochemical determination of chloramphenicol and florfenicol based on graphene/copper phthalocyanine nanocomposites modified glassy carbon electrode. Journal of The Electrochemical Society 166(8) (2019) B654. https://iopscience.iop.org/article/10.1149/2.0801908jes/meta [14] T. Kokulnathan, S.M. Chen. Design and construction of the gadolinium oxide nanorod-embedded graphene aerogel: a potential application for electrochemical detection of postharvest fungicide. ACS Applied Materials & Interfaces 12(14) (2020) 16216-16226. https://doi.org/10.1021/acsami.9b20224. [15] Y. Ke, Y. Sun, P. Lin, J. Zhou, Z. Xu, C. Cao, Y. Yang, S. Hu. Quantitative determination of rare earth elements in scheelite via LA-ICP-MS using REE-doped tungstate single crystals as calibration standards. Microchemical Journal 145 (2019) 642-647. https://doi.org/10.1016/j.microc.2018.11.016. [16] C. Esmaeili, M. S. Karimi, P. Norouzi, F. Wu, M. R. Ganjali, E. Safitri. Gadolinium (III) Tungstate Nanoparticles Modified Carbon Paste Electrode for Determination of Progesterone Using FFT Square- Wave Voltammetry Method. Journal of The Electrochemical Society 167(6) (2020) 067513. https://iopscience.iop.org/article/10.1149/1945-7111/ab828e/meta. https://doi.org/10.1007/s42452-019-0174-4 https://doi.org/10.1016/j.jallcom.2021.159687 https://doi.org/10.1039/C8QI01000E https://doi.org/10.1016/j.jhazmat.2018.12.072 https://doi.org/10.1016/j.microc.2019.02.025 https://doi.org/10.1016/j.microc.2020.105580 https://doi.org/10.1021/acssuschemeng.0c00502 https://doi.org/10.1016/j.microc.2021.106675 https://doi.org/10.1002/fsn3.2530 https://doi.org/10.1016/j.jhazmat.2020.122868 https://doi.org/10.1016/j.ecoenv.2020.111066 https://iopscience.iop.org/article/10.1149/2.0801908jes/meta https://doi.org/10.1021/acsami.9b20224 https://doi.org/10.1016/j.microc.2018.11.016 https://iopscience.iop.org/article/10.1149/1945-7111/ab828e/meta ADMET & DMPK 13(6) (2025) 3015 Electrochemical detection of chloramphenicol using Gd₂(WO₄)₃ doi: https://doi.org/10.5599/admet.3015 15 [17] J. Cheng, M. Wang. Preparation and electrical properties of gadolinium-doped strontium tungstate electrolyte for SOFC. Functional Materials Letters 13(03) (2020) 2050010. https://doi.org/10.1142/S1793604720500101. [18] A. Sakthivel, A. Chandrasekaran, S. Jayakumar, P. Manickam, S. Alwarappan. Sulphur doped graphitic carbon nitride as an efficient electrochemical platform for the detection of acetaminophen. Journal of The Electrochemical Society 166(15) (2019) B1461. https://doi.org/10.1149/2.0021915jes [19] S. Vinoth, K. S. Devi, A. Pandikumar. A comprehensive review on graphitic carbon nitride based electrochemical and biosensors for environmental and healthcare applications. Trends in Analytical Chemistry 140 (2021) 116-274. https://doi.org/10.1016/j.trac.2021.116274 [20] K. Kalidasan, S. Mallapur, B.B. Kulkarni, S.P. Maradur, D. Kumar, R. Deeksha, S. Kandaiah, P. Vishwa, S. Girish Kumar. Gadolinium modified g-C3N4 for S-Scheme heterojunction with monoclinic-WO3: Insights from DFT studies and related charge carrier dynamics. Journal of Materials Research and Technology 204 (2025) 166-176. https://doi.org/10.1016/j.jmst.2024.03.017 [21] R. Zhu, Y. Zhang, X. Fang, X. Cui, J. Wang, C. Yue, W. Fang, H. Zhao, Z. Li. In situ sulfur-doped graphitic carbon nitride nanosheets with enhanced electrogenerated chemiluminescence used for sensitive and selective sensing of l-cysteine. Journal of Materials Chemistry B 7(14) (2019) 2320-2329. https://doi.org/10.1039/C9TB00301K [22] H. Starukh, P. Praus. Doping of graphitic carbon nitride with non-metal elements and its applications in photocatalysis. Catalysts 10(10) (2020) 1119. https://doi.org/10.3390/catal10101119 [23] A. Sakthivel, A. Chandrasekaran, S. Jayakumar, P. Manickam, S. Alwarappan. Sulphur doped graphitic carbon nitride as an efficient electrochemical platform for the detection of acetaminophen. Journal of The Electrochemical Society 166(15) (2019) B1461. https://doi.org/10.1149/2.0021915jes [24] X. Yu, Aodenggerile, Z. Jiang, J. Shen, Z. Yan, W. Li, H. Qiu. Integrating the second near-infrared fluorescence imaging with clinical techniques for multimodal cancer imaging by neodymium doped gadolinium tungstate nanoparticles. Nano Research 14 (2021) 2160-2170. https://doi.org/10.1007/s12274-020-3136-7. [25] S.B. Ravikumar, T.A. Mallu, S. Subbareddy, S.A. Shivamurthy, V.D. Neelalochana, K.C. Shantakumar, J.R. Rajabathar, N. Ataollahi, S. Shadakshari. An enhanced non-enzymatic electrochemical sensor based on the Bi2S3-TiO2 nanocomposite with HNTs for the individual and simultaneous detection of 4- nitrophenol and nitrofurantoin in environmental samples. Journal of Materials Chemistry B 12(36) (2024) 9005-9017. https://doi.org/10.1039/D3TB03054G [26] V. Vinothkumar, M. Abinaya, S.M. Chen. Ultrasonic assisted preparation of CoMoO₄ nanoparticles modified electrochemical sensor for chloramphenicol determination. Journal of Solid State Chemistry 302 (2021) 122392. https://doi.org/10.1016/j.jssc.2021.122392 [27] L. Xiao, R. Xu, Q. Yuan, F. Wang. Highly sensitive electrochemical sensor for chloramphenicol based on MOF derived exfoliated porous carbon. Talanta 167 (2017) 39-43. https://doi.org/10.1016/j.talanta.2017.01.078 [28] R. Nehru, C. D. Dong, C.W. Chen. Cobalt-doped Fe₃O₄ nanospheres deposited on graphene oxide as electrode materials for electrochemical sensing of the antibiotic drug. ACS Applied Nano Materials 4(7) (2021) 6768-6777. https://doi.org/10.1021/acsanm.1c00826. [29] P. Jakubec, V. Urbanová, Z. Medříková, R. Zbořil. Advanced sensing of antibiotics with magnetic gold nanocomposite: Electrochemical detection of chloramphenicol. Chemistry - A European Journal 22(40) (2016) 14279-14284. https://doi.org/10.1002/chem.201602434 [30] F.Y. Kong, Y. Luo, J.W. Zhang, J.Y. Wang, W.W. Li, W. Wang. Facile synthesis of reduced graphene oxide supported Pt-Pd nanocubes with enhanced electrocatalytic activity for chloramphenicol determination. Journal of Electroanalytical Chemistry 781 (2016) 389-394. https://doi.org/10.1016/j.jelechem.2016.06.018 [31] M. Yadav, V. Ganesan, R. Gupta, D.K. Yadav, P.K. Sonkar. Cobalt oxide nanocrystals anchored on graphene sheets for electrochemical determination of chloramphenicol. Microchemical Journal 146 (2019) 881-887. https://doi.org/10.1016/j.microc.2019.02.025 https://doi.org/10.5599/admet.3015 https://doi.org/10.1142/S1793604720500101 https://doi.org/10.1149/2.0021915jes https://doi.org/10.1016/j.trac.2021.116274 https://doi.org/10.1016/j.jmst.2024.03.017 https://doi.org/10.1039/C9TB00301K https://doi.org/10.3390/catal10101119 https://doi.org/10.1149/2.0021915jes https://doi.org/10.1007/s12274-020-3136-7 https://doi.org/10.1039/D3TB03054G https://doi.org/10.1016/j.jssc.2021.122392 https://doi.org/10.1016/j.talanta.2017.01.078 https://doi.org/10.1021/acsanm.1c00826 https://doi.org/10.1002/chem.201602434 https://doi.org/10.1016/j.jelechem.2016.06.018 https://doi.org/10.1016/j.microc.2019.02.025 13T. Alanahally Mallu et al. ADMET & DMPK 13(6) (2025) 3015 16 [32] T. Sun, H. Pan, Y. Mei, P. Zhang, D. Zeng, X. Liu, S. Rong, D. Chang. Electrochemical sensor sensitive detection of chloramphenicol based on ionic-liquid-assisted synthesis of de-layered molybdenum disulfide/graphene oxide nanocomposites. Journal of Applied Electrochemistry 49(3) (2019) 261-270. https://doi.org/10.1007/s10800-018-1271-6 [33] K. Giribabu, S.C. Jang, Y. Haldorai, M. Rethinasabapathy, S.Y. Oh, A. Rengaraj, Y.K. Han, W.S. Cho, C. Roh, Y.S. Huh. Electrochemical determination of chloramphenicol using a glassy carbon electrode modified with dendrite-like Fe3O4 nanoparticles. Carbon Letters 23 (2017) 38-47. https://doi.org/10.5714/CL.2017.23.038 ©2025 by the authors; licensee IAPC, Zagreb, Croatia. This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/) https://doi.org/10.1007/s10800-018-1271-6 https://doi.org/10.5714/CL.2017.23.038 http://creativecommons.org/licenses/by/3.0/