The use of heated models to describe the thermal environment in shelters for farm animals Markus Pyykkönen Pyykkönen, M. 1992.The use ofheated models to describe the thermal environment in shelters for farm animals. Agric. Sci. Finl. 1: 539-545. (Dept. Agric. Eng. and Household Tech., Viikki F, SF-00014 University of Helsinki, Finland.) The dry bulb air temperature is still the most commonly used parameter to characterize the thermal environment, even though it disregards the effect of air velocity and the thermal properties of the flooring material on the heat loss from the animal. Measurements in the laboratory confirmed that an uninsulated heated model with an overall thermal resistance of 0.11 m 2 KW' 1 is sensitive enough to differentiate between changes in conduction, convection and radiation conditions. Measurements on farms showed that the heat loss simulated by mechanical models gives a more diversified description of the thermal environment than the dry bulb air temperature. Although the uninsulated mechanical model is not a standardized device, it is a useful method for measuring the thermal environment especially under sheltered winter conditions. Key words: heat dissipating model, heat loss, sensible heat loss, dry bulb air temperature Introduction Mathematical animal heat loss models are used in converting the heat loss data obtained in feeding experiments into design values for ventilation engi- neers. In these conversions, gross simplifications are introduced, i.e. the heat loss is only a function of air temperature, live weight and production level (STRÖM and Zhang 1989). This approach is a major reason why the dry bulb air temperature measured at a representative location is still the parameter most commonly used to characterize the thermal environment (HAHNet al. 1983) in practice. Another reason may be the abundance of simple and reliable methods for measuring the air temper- ature. Anyway, the dry bulb air temperature dis- regards the effect of air velocity and the flooring material on the heat loss from the animals. It also disregards the radiative heat loss. The quantification of the thermal environment would be more accurate if the dry bulb air temper- ature were replaced by an effective temperature combining the cooling effect of convection, con- duction and radiation with the cooling capacity of evaporation. The aim of this project was to develop a method to simulate the sensible heat loss from the animals in order to obtain a good characterization of the thermal environment at the level of the individual animal on farms and to study whether the charac- terization given by the heat dissipating model is different from that given by the dry bulb air temper- 539 Agric. Sei. Finl. 1 (1992) https://www.c-info.fi/en/info/?token=8B15f9zfIZUN_4Z3.Y1keEZV_Qd80E80VlMnVSw.YhJDxjMaSZjUsTDizkkiv2-pm8sn7mLB_VSKtK5KIuUi0TNZZxRH6mu2t0qabAyKp3sCoQROWNgzREWGe4iKNZ86pu1XYiCgItgYVWRbzYU_IRH1V1u4PJLTvASB0CcC33WovA63RVXUbMIJlj3qtRf8g8rZ_Wj5G3-Bk7H8m0cVUbFIVu3xGhgbCzxdGBrp0hiyjaGb052xCsC3ubTiBisc_NuVscHw1K192ZzfmbhL9JsD7Mikxf6e4eS9qJZ9_wdBNWpDFKzOi2T_ ature. The method was to be sensitive enough to measure the small changes in the environment in order to evaluate the function of the ventilation system from the thermal point of view. The model was to be suitable for continuous measurement in pens even in the presence of animals. Review of the literature The cooling effect of the environment has been measured with a katathermometer (MOTHES 1971, Trippe 1984, Kunz 1985) which mesures the time needed for a heated bulb to cool from 35°C to 30°C. The cooling effect, measured by thekatathermome- ter, does not measure the total heat loss from the animal. It gives an estimate of the maximum heat loss to the surrounding air (Trippe 1984), but it disregards the heat loss by conduction to the floor, which is important for juvenile animals spending most of their time lying. The heat loss from animals has been simulated by heat dissipating models. These models generally include the following assumptions (Hahn and BÖE 1985): I. ignoring the evaporative component of energy exchange. 2. the use of uniform thermal insulation over the total surface of the model. 3. a level of thermal insulation corresponding to the vasoconstricted state of the animal. 4. no postural adjustments. In the simplest heat dissipating models the heat flow from the wami body was calculated from the cooling time for a certain temperature interval (Ny- GAARD 1966). This introduced the problem of chan- ging temperature difference during the measure- ment. The problem was usually solved by measur- ing the cooling time for a narrow temperature inter- val, and by calculating the temperature difference from the average temperature difference during the measurement. Insulated full-scale cow models have been used in estimating the feed energy requirement of beef cattle and suckler cows under unsheltered winter conditions (Webster 1971, Burnett and Bruce 1987). The models were based on a constant inter- nal temperature and on an overall thermal insula- tion, corresponding to that of a real animal. They ignored the evaporative component of energy exchange. A cylindrical 0.4-scale model gave sim- ilar thermal responses in a changing climate as the full-scale model (Jones 1982). Two heated models, one insulated, of the size and overall thermal resistance of a 40 kg lamb, and another uninsulated black copper sphere were used by Hahn and Böe (1985) in estimating the energy demand of lambs in different environments. The models were placed at a height of 0.5 m above the floor. The results of the two models were highly correlated (r = 0.96). The good correlation between the heating requirements of insulated and uninsu- lated models indicates that uninsulated models could provide an acceptable measure of the thermal environment (Hahn and Böe 1985). The sensible heat flow from heat dissipating models is essential- ly the same as that from real animals, as summa- rized by the equation presented by Esmay and Dixon (1986): Qs= A * C * (Ta-Te) where: Qs= sensible heat loss, W; A = surface area of animal; Ta= surface temperature of animal, K; Te= average temperature of surroundings, K; c = overall sensible heat transfer coefficient. Construction of the heated model To test whether uninsulated heated models provide an acceptable measure of the thermalenvironment, a heated model with an overall thermalresistance of 2 10.1 lm" KW was constructed. The surface area of the model was chosen so that the contact area of the model to the floor, 23.3% of the total surface, was about the same as that of a lying animal, which is about 20% (Gommers et al. 1970). 540 Agric. Sd. Finl. 1 (1992) With a given resistance and a constant voltage, the energy requirement of an electrically heated model can be calculated by measuring the time for the power to be switched on, and by multiplying it by the electrical power. The heat loss from the 2 .model (Wm ") is then computed by divisionby the total measuring time and the surface area of the model. The heated model was made ofa standard alumi- nium box used in electronics (125 * 80 * 57.5 mm) which was filled with ethylene glycol (50%). The amount of fluid was 0.3 kg. The mean temperature of the fluid during a heating cycle was 32.5°C, ranging from 31.5°C to 33.5°C. The model was heated with a heating element, placed about 2mm from the bottom surface of the vessel. The heating was controlled through a thermistor, which started and stopped a timer when switching the heating on lig. I. Working principle of the heated model. A Voltage supply and registering unit A 1 Transformer A 2 Rectifier and voltage stabilizer A 3 Voltage regulator and stabilizer A 4 Relay switch for the timer A 5 A 3 Timer B Regulating unit B I Regulation of the control voltage B 2 Comparator B 3 Relay for the heating voltage, B 2 controlling the relay. C Measuring device C 1 Heating element (approx. 5 ohm) C 2 Sensor lube with two thermistors 541 Agric. Sei. Finl. 1 (1992) Table I. Coefficients of the regression lines between the temperature difference and the heat loss for the different flooring materials with the heated model. Flooring Coefficient of Intercept Coefficient material determination a b Concrete 0.99 -31.2 14.3*** Plastic 0.99 -21.7 11.2*** Steel 0.98 -19.1 15,4*** Straw 0.99 -17.2 B.6*** Wood 0.99 -26.1 11.2*** *** po.ool ns not significant ventilation system was tested with a thermohygro- graf at an accuracy of I°C. Results from the cow shelters The heat loss was measured in one week periods over five weeks. The lowest outside air temperature was -11.0°C, and the weekly means varied from -l.l°Cto+2.B°C. The average ambient temperature was 13.5°C at Suitia, ranging from 12°C to 15°C. The weekly means of the ambient temperature varied from + I.l°C to+4.3°C in the uninsulated shelter at Muurla. The heat loss was 206.1+11.5 Wm'2 in the pen and 202.7±22.7 Wm ~ in the shelter (Table 2). The difference in the thermal environment be- tween the pen at Suitia and the uninsulated shelter with deep litter at Muurla is obvious, if the environ- ment is describedby the ambient temperature. If the thermal environment is described by the heat loss from the heated model, there was no difference between the environments. The heat loss in the uninsulated shelter was highly influenced by the heat produced by fermentation in the deep litter. Results from the piggeries There were significant differences in the heat loss measured by the model when placed in different Table 4. Heat loss from the model in farrowing house C and in weaner house of the same farm before and after reducing the ventilation rate. Farrowin Weaner house g house Parameter before after Observations 10 8 9 Mean ambient temperature, °C 19 24 24 Mean heat loss, WirT2 110“ 133° 108b S.D., WirT 2 3.4 22.4 9.4 “,b significant differences are shown by different letters, p>o.ol farrowing houses even though the measured aver- age ambient temperatures were the same, 19°C (Table 3). The difference in the heat loss between farrow- ing house A and farrowing house B, about 50 Wm , corresponds to an increase of air velocity of 20.2 ms at an air temperature of 19°C. The thermal environment of farrowing house C was compared to that of the weaner house of the same farm. Despite the higher ambient temperature the heat loss from the model was higher in the weaner house (Table 4). After reducing the air ve- locity at the floor level by decreasing the ventilation rate in the weaner house, the difference in the heat loss disappeared. 543 Agric. Sei. Fin!. 1 (1992) Conclusions The measurements on the farms showed that the dry bulb air temperature does not always give an accur- ate picture of the thermal environment. In condi- tions where animals should be sheltered free from draft, the heat loss simulated by mechanical models gives a more diversified description than the air temperature. These results completely agree with the conclusion of Hahn and BÖE (1985) that unin- sulated models can provide an acceptable method of measuring the thermal environment. The model is not able to regulate the heat loss, which in combination with the rather low heat re- 2 isistance of 0.11 m KW means that the model is more sensitive to changes in the environment than a live animal. The sensitivity of the model is not a disadvantage however, as the function of the venti- lation system is measured. Even small changes in the environment can be detected with the model. Altough the model does not measure the heat loss from the animal, it gives an estimate of the maxi- mum sensible heat loss. In this respect it resembles the katathermometer used by Trippe (1984). The measurements on farms showed that the he- ated model was durable enough to be used on farms, even on the floor in pens where there are animals. Yet, the model cannot be used in un- sheltered winter conditions, where the heat loss from the model exceeds 450Wm . A heat loss of 465Wm means that the heating element is switch- ed on all the time. Although the uninsulated model is not a stand- ardized device for measuring the thermal environ- ment, it is a useful method especially under shelter- ed winter conditions as indicated by the measure- ments on the farms. The model can be used toadjust the ventilation and to estimate the effect of a change in the thermal environment, except a change in the relative humidity, on the heat loss from the animals. In studying the correlation between the thermal environment and the animal health the model pro- vides a better description of the thermal environ- ment than that given by the dry bulb air temper- ature. As the thermal properties of the model are known, it is possible to calculate the corresponding effective temperature where the heat loss is only a function of the temperature. The effective temper- ature can then be used in the mathematical animal heat loss models to estimate the heat loss from animals in the situation measured. References Burnett, G. A. & Bruce, J. M. 1978. Thermal simulation of suckler cow. Farm Bldg. Progress 54: 11-13. Esmay.L. M. & Dixon, J.E. 1986. Environmental control for agricultural buildings. 287 p. Westport, Connecticut. Hahn, G. L. & Böe, K. 1985. Evaluating thermal demand in cold sheep housing. ASAE-paperno. MCR 85-150. 11 p. —, Nygaard.A. & Simensen. E. 1983.Towards establishing rational criteria for selection and design of livestock environments. ASAE-paper 83-4517. Gommers. F. 1., Cristison, G. I. & Curtis, S. E. 1970. Estimating animal floor contact areas. J. Anim. Sci. 40: 552-555. Jones, C. G. 1982. Modelling the integrated climatic energy demand on animals. Interim report to the Agricultural Research Council (U.K.). 12p. Kunz, P. 1985. Kälberhaltung in Hiitten. FAT-Berichte 269. 12 p. Mothes.E. 1971. Stallklima. 196 p. Berlin. Nilsson. C. 1988. Floors in animal houses. Institutionen för lantbrukets byggnadsteknik. Rapport 61. Ström. J. S. & Zhang. G. 1989. Thermal control in animal buildings. In: Dodd, V. A. & Grace, P. M. (eds.). Agricultural engineering 2. Rotterdam, p. 1265-1278. Trippe, M. 1984. Priifung des Kriteriums Abkiihlungsgrösse auf seine Eignung zurweitergehenden Charakterisierung des Mikroklimas in Tierställen. Institut fur Tierhygiene der Tierärtzlichen Hochschule Hannover. 106 p. Webster, A. J.F. 1971. Prediction ofheat losses from cattle exposed to cold outdoor environments. J. Appi. Physio. 30: 684-690. Manuscript received April 1992 Markus Pyykkönen Department of Agricultural Engineering and Household Technology Viikki F SF-00014 University ofHelsinki, Finland 544 Agric. Sei. Fint. 1 (1992) SELOSTUS Termisen ympäristön mittaaminen eläinsuojissa Markus Pyykkönen Helsingin yliopisto Ilman keskimääräistä lämpötilaa käytetään yleisesti kuvaa- maan eläinsuojien termistä ympäristöä. Ilman lämpötila ei sisällä tietoa ilman liikenopeuden eikä lattiamateriaalin vaiku- tuksesta eläimen lämmönluovutukseen. Eläinmallin luovuttamaa lämpömäärää voi periaatteessa käyttää eläimen termisen ympäristön kuvaamiseen, sillä mal- lin vapaa lämmönluovutus on samojen fysiikan lakien alainen kuin eläimen vapaa lämmönluovutus. Jotta termisen ympäris- tön jatkuva mittaaminen olisi mahdollista, rakennettiin läm- mitettävä mekaaninen malli, jonka lämpövastus oli 0,11 m’ KW 1. Lämmitettävänä mallina käytettiin etyleeniglykolilla (50 %) täytettyä alumiiniastiaa (125 * 80 * 57,5 mm). Nesteen määrä oli 0,3 kg. Lämmitysvastuksen sisältävä kuparikotelo oli 2 mm alumiiniastian pohjan yläpuolella. Lämmitystä oh- jaava termistön kytki käyttöjännitteen aikalaskuriin, joka oli aina kytkettynä päälle lämmitysvastuksen lämmittäessä. Koska teho P= U 2 * R l , niin mallin luovuttama lämpö- määrä on lämmitysajan ja tehon tulo, kun vastus ja jännite ovat vakioidut. Mallin luovuttama vapaa lämpö saadaan jaka- malla lämpömäärä mittausajalla ja mallin pinta-alalla. Lämmitettävää mallia kokeiltiin käytännön olosuhteissa Suitian koetilalla vasikkakarsinassa, jossa oli puinen rakolat- tia, ja eristämättömässä olkipohjaisessa makuusuojassa Muurlassa. Lämmönluovutus mitattiin viikon jaksoissa viiden viikon aikana. Olosuhteissa oli selvä ero, kun niitä kuvattiin ympäristön lämpötilalla, sillä karsinassa lämpötila oli 13,5 °C ja makuu- suojassa 2,6 °C. Mallin lämmönluovutuksen perusteella ei olosuhteissa ollut eroa, sillä mallin lämmönluovutus karsinas- sa oli 206,1 ± 11,5Wm 2 jamakuusuojassa 202,7+22,7 Wm 2 . Mallin avulla mitattiin porsituskarsinan termistä ympäris- töä kolmessa sikalassa. Vaikka ilman lämpötilan asetusarvo oli kaikissa sikaloissa 19 °C, niin mallin lämmönluovutus oli tilastollisesti merkitsevästi erilainen eri sikaloissa. Ero suu- rimman ja pienimmän lämmönluovutuksen välillä, noin 50Wm 2 , vastaa o,2ms 1 eroa ilman nopeudessa. Sikalassa C mallin lämmönluovutus varhaisvieroitusosas- tossa (133 Wm'2 ) oli suurempi kuin porsituskarsinassa (110 Wm "), vaikka ilman lämpötila oli27 °Cvarhaisvieroitusosas- tossa. Kun ilmanvaihdon säätöä muutettiin varhaisvieroitus- osastossa, mallin lämmönluovutus oli yhtä suuri (108 Wnr) kuin porsituskarsinassa. Mittaukset osoittivat, että ilman lämpötila ei aina anna tarkkaa kuvaa termisestä ympäristöstä. Lämpöä luovuttavat mallit antavat monipuolisemman kuvan termisestä ympäris- töstä kuin ympäristön lämpötila ja mallien avulla voidaan mitata eläinten oleskelualueella tapahtuvat termisen ympäris- tön muutokset. 545 Agric. Sei. Fint. 1 (1992)