Maataloustieteellinen A ikakauskirja Vol. 62: 407—415, 1990 Effect of thawing on the quality of frozen mechanically deboned meat L. RIIHONEN* and P. LINKO** * Finnish Meat Research Centre, Box 56, SF-13101 Hämeenlinna, Finland ** Laboratory of Biotechnology and Food Engineering, Department of Chemical Engineering, Helsinki University of Technology, SF-02150 Espoo, Finland Abstract. The effect of thawing conditions on the quality of mechanically deboned beef (MDB) and mechanically deboned pork (MDP) recovered using a pressure-based Inject Star deboner was investigated. Samples were recovered using a freshly disinfected machine, and immediately packed in 3 kg portions in high density polyethylene (HDPE)-coated cartons or in Cryovac vacuum bags. Three methods of thawing were used: microwave thawing and thawing at +4°C and at +2l°C. All samples were analysed chemically and microbiologically imme- diately after thawing. Microwave thawing resulted in a better quality product (P<0.05) than thawing at +4°C or at +2l°C. Index words: mechanically deboned meat (MDM), thawing conditions, microwave thawing Introduction Very few studies on thawing conditions of frozen mechanically deboned meat have been published. Selmeci et al. (1) investigated the differences between microwave and room temperature thawing on mechanically de- boned meat from ribs, backbones and leg bones as compared with fresh unfrozen meat. The main differences were in the aw-values and in the contents of fat, moisture, calcium and phosphate. Due to the faster thawing technique the moisture contents and the a w-values were higher in samples thawed by microwaves than in those defrozen at room temperature. Al- though the microwave thawing of mechanical- ly deboned meat has not been extensively studied, much work has been done to deter- mine the efficiency of microwaves in the in- activation of microorganisms. Most research reports claim that heat not microwaves themselves kills microbes (2). Moreover, it has also been claimed that microwaves affect certain microbialactivities in a way that cannot be due to heat alone. 407 JOURNAL OF AGRICULTURAL SCIENCE IN FINLAND https://www.c-info.fi/en/info/?token=zatUs7rdqtoMELpq.jZqq1cY9aay_kVCxcPjbbA.BQxeQuKBIP84n7-ftXlkOgK_Nt4ep0re_RQuw4uxW3q-lTfc_SachB5T1a5Fl8BGtM1t7o0rEq6GothzQnxgPm3dwwSURO9Hr5_vr9fJMDZUo9A12SecsYxTfTTmdHSMwPon3w2-7l4fIQLvjMbpsqhyp94J4HWiinu57hkWTSkmxBJ0E00 Therefore, it has been suggested that micro- waves could cause some changes in micro- biological systems which cannot be wholly ex- plained by the thermal energy generated by dielectric molecules (3). Taoukis et al. (4) reported that thawing of frozen raw materials is integral to many food manufacturing processes. It is important to optimize thawing rates in order to avoid microbial problems, chemical deterioration and water loss due to dripping or dehydration. The development of microwave equiment that achieves a more uniform power distribution and a better control of microwave heating by combining lower frequency microwave gener- ation with convection heating or cooling al- lows the exploration of such systems on an in- dustrial scale. Tempering or partial thawing of meat products with microwaves prior to processing is currently practiced (5). Freezing itself, if performed sufficient rapidly, has little demonstrable effect upon colour, flavour, odour or juiciness of meat after cooking. Frozen storage, however, re- sults in a gradual decrease in odour and flavour acceptability. The methods of freez- ing and of packaging and the storage time and temperature have a significant effect on the maintenance of a satisfactory quality level. Tight-fitting, moisture-proof packaging and constant storage temperatures of 18°C or lower are the most critical requirements. Odour and flavour changes occur mainly in the fatty constituents of meat, pork being more susceptible to such changes thanbeef or lamb. Microwave and dielectric heating can be employed to effect rapid thawing (6, 7). The effect of packaging material on the storage properties of mechanically deboned meat has not been extensively studied. On the other hand, extensive information is available on thepackaging of fresh meat. For example, it has been shown that microbiological spoil- age is at its lowest when controlled atmosphere packaging in a carbon dioxide atmosphere is used (8). The second best alternative is a vacuum pack, followed by packing under ni- trogen, and the worst alternative is unpack- aged meat. Studies have also shown (8, 9) that carbon dioxide retards bacterial growth significant- ly, and that oxygen stimulates microbial growth. The amount of oxygen in a vacuum pack must therefore be minimized and the meat should be fresh. Some carbon dioxide is then formed in the pack by the action of the small numbers of microorganisms present in the meat. De Zutter and van Hoof (10) studied the microbiological characteristics of the fluid exuded from beef in a vacuum pack, and showed that the fluid is very susceptible to microbiological spoilage even during a short storage period. The effects of lactic acid bac- teria, and the penetrability of the packaging material during the deterioration of vacuum packaged beef have also been studied. Vacuum packaged beef was shown to deteriorate at + 5°C, even in the absence of noticeable mi- crobial contamination. The meat spoiled, al- though it was vacuum-packaged in a film with poor oxygen penetration properites (1 cm 3 02/mV24 h/atm) and the spoilage rate in- creased with the penetrability of the packaging material (11). Even a three week storage period could be achieved with a vacuum pack, if the storage temperature was +1... + 3°C (12). Mechanical deboning is more economical than hand boning. Because all the meat can thusbe recovered and used in meat products, the aim of this invetigation was to evaluate the effect of thawing conditions on the quality of frozen, mechanically deboned meat. Materials and methods Experimental Procedure The research was carried out at theproduc- tion plant Osuusteurastamo Karjaportti in Mikkeli, and at the Finnish Meat Research Centre in Hämeenlinna. The machine used in the tests was a pressure type Inject Star (P-60) deboning machine (Hollstein-Fuhrman, Vien- na, Austria). 408 Table 1. The origin of bone, sample coding and the duration of frozen storage. Samples MDB Beef, from bones of cows MDP Pork, from aged (72h +4°C) bones of pigs Duration of frozen storage (weeks) Analysed samples 4 8 12 16 20 MDP MDP MDB MDP MDB MDP MDB MDB Mechanically deboned meat samples were recovered in a freshly disinfected machine, and immediately packaged in 3 kg samples in plastic-coated cartons (HDPE-plastic) and in Cryovac vacuum bags. The conditions used were; temperature of bones to be processed + 6°C, freezing temperature 40°C, utiliza- tion of freezing air 98000 mVh in 6900 m 3, frozen storage temperature 24°C. Table 1 shows the origin of thebones, sam- ple coding and the time in the freezer storage. The recovering temperature immediately af- ter separation was +4°C. Thawing conditions: 1) microwave thawing 2) thawing at +4°C 3) thawing at +2l°C In microwave thawing, a Husqvarna Mi- kronet (650W) microwave oven was used. Packaged samples were first thawed for 15 minutes. Heating was stopped for 10 minutes, after which it was repeated for 15 minutes. The samples thawed in microwave oven, at 21 °C (18 h) and at +4°C (42 h) were analysed immediately after thawing. Measured parameters: chemical; fat, protein, ash, calcium, phos- phate and bone particle content, pH, peroxide value, free fatty acids (FFA %), thiobarbituric acid value (TBA value), connective tissue con- tent and water holding capacity, physical; colour, microbiological; aerobic bacteria count, con- forms 37°C, coliforms 44°C and lactic acid bacteria Evaluation of the quality of mechanically deboned meat Methods used for evaluation of the quality of mechanically deboned meat were as presented earlier by Riikonen (13, 14). Statistical analysis The results were analysed statistically using a Multiplan graph method and the Windows- Exel graph programme. The three-dimen- sional 3D Graph programme was also used. Analyses were carried out from three samples in duplicate. Standard deviations were calcu- lated for all the variables studied during stor- age. Two tailed t-tests were used to evaluate differences between the various thawing con- ditions. Results and Discussion The composition of the MDM and MDP samples used is presented in Figure 1 and the effects of thawing on a frozen sample of MDB in Figures 2—3 and of MDP in Figures 4—5. A rapid rise in the population of bacteria was detected in the vacuum-packaged samples thawed at + 21°C temperature (Figs. 3 and 5). The difference between microwave thawing and thawing at +2l°C was significant (P<0.05). This was also indicated as a fall- ing in pH from 6.05 to 5.80 in MDB and from 6.33 to 6.20 in MDP samples (P<0.05). This is in agreement with the observation of New- some et al.(15), who showed that vacuum packaging causes a shift in the microflora from a predominance of aerobic spoilage or- ganisms to lactic acid bacteria. As a result of 409 the impermeability of thepackaging film, car- bon dioxide builds up inside the vacuum pack- age. The change in atmosphere within the vacuum package causes a decrease in the per- centage of aerobic organisms, such as pseu- domonads, and an increase in the percentage of lactic acid bacteria (Figs. 3 and 5). Stan- dard deviations varied in MDB samples from 0.14 to 0.33 and in MDP samples from 0.13 to 0.33. Differences between microwave thaw- ing and thawing at +2l°C and +4°C were significant (P<0.05). Some lactic acid bac- teria may even be stimulatedby increased car- bon dioxide concentrations (8). Moreover, lac- tic acid bacteria are capable of producing or- ganic acids, hydrogen peroxide, and/or bacte- riosides which may further inhibit spoilage microorganisms. When the samples were thawed at +2l°C the free fatty acid (FFA-%)-value in MDP- sample was the highest, 1.46 after 16 weeks (PC0.05). No samples packed in vacuum bags were available in the thawing at +4°C after stor- age for 16 weeks (Fig. 4A). After 12 weeks of frozen storage the FFA-%-value of the MDB sample had in- creased from 0.66 to 0.90 in samples packaged in vacuum bags and thawed at +2l°C (Fig. 2A). Standard deviations varied from 0.04 to 0.27. The trend continued to a storage time of 16weeks. Thiobarbituric acid (TBA)-values did not vary significantly under different thawing conditions (Figs. 2B and 4B). Stan- dard deviations varied from 0.02 to 0.37. The difference between vacuum packaging and carton packaging was clearest when analysing the peroxide results. For example, peroxide values (meqO/kg) of mechanically deboned pork (MDP) after four weeks of fro- zen storage in cartons were 1.22 when thaw- ing with microwave and 1.13 and 0.87, respec- tively when thawing at +2l°C and +4°C. The corresponding figures for samples stored in vacuum bags were 0.74, 0.41 and 0.36. The peroxide values after 16 weeks of frozen stor- age were 2.63, 3.95 and 2.67 in cartons and 0.77, 0.45 and (no results) in vacuum bags (Figs. 2C and 4C). Standard deviations of the results varied from 0.03 to 0.78. MDB-sam- Fig. 1. The composition of mechanically deboned beef (MDB) and pork (MDP). Connect.tis% is the connective tissue content and phosp.% is the phosphate content. 410 pies were also analysed after 20 weeks of fro- zen storage, but analysis of the MDP was dis- continued after 16 weeks, because of the poorer keeping qualities of the pork. The number of bacteria in meat may in- crease by contamination during freezing oper- ations. However, freezing kills a small propor- tion of all the microorganisms present in meat; more of them die during frozen storage, but this process occurs rather slowly (approxi- mately 5% of the population per month) at temperatures of about 2o°C. Gram-negative rods are more susceptible than gram-positive cocci. Spores remain unaffected, whereas e.g. vegetative cells of Clostridium perfringens die rapidly. Dispite these effects bacterial levels may be very high in thawed beef. The timere- quired for thawing of frozen meats depends Fig. 2. Comparison of different methods of thawing of condition in MDB. Analysis by A) free fatty acid value (FFA %), B) thiobarbituric acid value (TBA mg/kg) and C) peroxide value (milliequivalent oxygen/kg). ZERO = results after one day, C =carton packaging and V = vacuum packaging, e.g. 12CW= carton packaging after 12 weeks’ storage. Mean values of three replicates car- ried out in duplicate. 411 on the temperature of the meat and its ther- mal capacity, the thawing medium and its temperature and circulation, the size of the unit being thawed, and other lesser factors (6, 7). Although microorganisms do not grow faster on thawed meat than on fresh meat, the product is very perishable as soon as the sur- face temperature increases above O°C. It is often stated that thawed meat is more perishable than fresh meat that has never been frozen, because of the drip exuded from thawed meat, which is a good medium for microbial growth. However, the growth rate of bacteria on thawed meat is not very dif- ferent from the rate on equivalent non-frozen meat. Meat that has been frozen and thawed in commercial practice, however, commonly carries much more bacteria than the equiva- Fig. 3. A) The aerobic microbial counts, log(cfu/g) and B) the lactic acid bacterial counts, log(cfu/g) as a function of the method of thawing of MDB. ZERO =results after one day, C =carton packaging and V = vacuum packaging, e.g. 12CW = carton packaging after 12 weeks’ storage. Mean values of three replicates carried out in duplicate. 412 lent fresh meat, leading for this reason to a shorter shelf life. Puolanne and Kukkonen (16) studied the effects of freezing of meat on the water-bind- ing capacity of cooked sausage. Lean ground beef was frozen in plastic bags and thawed at room temperature (20°C/1 hour), at +4°C temperature (10 hours) and in a microwave oven (2—3 min). Thawing at room tempera- ture was significantly the poorest method. This is in agreement with the results of this work, in which it was concluded that micro- Fig. 4. Comparison of different methods of thawing of MDP. A) free fatty acid value (FFA Vo) B) thiobarbituric acid value (TBA-value) and C) peroxidevalue (milliequiva- lent oxygen /kg). ZERO =results after one day, C = carton packaging and V = vacuum packaging, e.g. 12CW=carton packaging after 12weeks’ storage. Mean values of three replicates carried out in duplicate. x=no results. 413 wave thawing was the best alternative of the techniques used. The vacuum-packaged sam- ples showed the least changes. Microwave ir- radiation has the potential to accelerate the thawing process, preferably in a continuous operation. However, the fear of localized overheating has limited the application of microwave thawing to food systems which re- quire larger manufacturing volumes. Acknowledgements. The authors are grateful to Osuusteurastamo Karjaportti for sponsoring this inves- tigation. Fig. 5. A) The aerobic microbial counts, log(cfu/g), and B) the lactic acid bacterial counts, log(cfu/g) as a function of the method of thawing of MDP. ZERO =results after one day, C = carton packaging and V = vacuum packaging, e.g. 12CW=carton packaging after 12 weeks’ storage. Mean values of three replicates carried out in duplicate. 414 References 1 Selmeci, G., Cseh, F., Juhasz, L, Rosa, L. and San- ta, L, 1983. Analysis of mechanically deboned meat /MDMA Effecet of microwave treatment on meat paste parameters. Proc. 29th Eur. Meet. Meat Res. Work., Panama, pp. 793—795 2 Decareau, R.V., 1985. Microwaves in the food processing industry. Academic Press, Orlando , Lon- don, pp. 182—202 3 Funo, D.Y.C. and Cunningham, E., 1980. Effect of microwaves on microorganisms in foods. Journal of Food Protection, 43: 641—650 4 Taoukis, P., Davis, E.A., Davis, H.T., Gordon, J. and Talmon, Y., 1987. Mathematical modelling of microwave thawing by the modifield isotherm migra- tion method. J. Food Sci. 52; 455—458 5 Decareau, R., 1986. Pasteurization and sterilization, microwave food processing equipment throughout the world. Food Technol. 40(6): 99—105 6 Cleland, A.C. and Earle, R.L., 1984. Assessment of freezing prediction methods. J. Food Sci. 49: 1034—1037 7 Price, J.F. and Schweioert, 8.5., 1987. The Science ofMeat and Meat Products. Protective packaging of meat and meat products. Westport, pp. 489—505 8 Ahvenainen, R., 1989. Gas packaging of chilled meat products and ready to eat foods. Technical Research Centre of Finland, Publications 58, Helsinki pp. 49—50 9 Kastner, C.L. and Kropf, D.H., 1986. Processed meat products and safety issues. Dairy and Food Sani- tation, 6 186—193 10 De Zutter, L. and van Hoof, J., 1982. Bacterial growth in exudate of vacuum packed beef. Proc. 28th Eur. Meet. Meat Res. Work., Madrid, pp. 355—356 11 Egan, A.S. and Shay, 8.J., 1982. Sicnificance of lac- tobacilli and film permeability in the spoilage of vacuum-packaged beef. J. Food Sci. 47: 1119—1122 12 Tändler, K., 1982. Hygiene im Zerlege- und Abpack- bereich Teil 1, Die Fleischerei 33: 772 —780 13 Riikonen, L., Laine, J. and Kärkkäinen, T., 1990. Storage properties and quality of meats deboned by different methods. J. Agric. Sci. Finl. 62: 381 —395 14 Riihonen, L., Hämäläinen, K. and Väänänen, E., 1990. Applications of mechanically deboned meat in sausage mass. J. Agric. Sci. Finl. 62: 397—405 15 Newsome, R.L., Seman, D.L., Lanolois, 8.E., Woody, W.G., Fox, J.D. and Gay, N., 1987. Micro- biological quality of restructured and conventional steaks manufactured from electrically stimulated hot- and coldboned carcasses. J. Food Sci. 52: 861—864 16 Puolanne, E. and Kukkonen, E., 1982. The effect of meat freezing on water bindingcapacity of cooked sau- sage. Proc. 28th Eur. Meet. Meat Res. Work., Madrid, pp 146—148 Deb Ms received July 12 1990 SELOSTUS Sulatusolosuhteiden vaikutus pakastetun mekaanisesti luista erotetun lihan laatuun L. Riikonen,* ja P. Linko** • Lihateollisuuden tutkimuskeskus PL 56, SF-13101 Hämeenlinna, Suomi •* Biotekniikan ja elintarviketeknologian laboratorio Kemian tekniikan laitos Teknillinen korkeakoulu, SF-02150 Espoo, Suomi Työssä tutkittiin sulatusolosuhteiden vaikutusta pakas- tetun paineeseen perustuvalla Inject Star koneella erote- tun naudan ja sian lihan laatuun. Näytteet otettiin koneellisesti luista erotustalihasta ja pakattiin kolmen kilon näyte-erissä HDPE-vuorattuihin laatikoihin ja Cryovac-vakuumipusseihin.Tutkimuksessa käytettiin kolmenlaista sulatustapahtumaa; mikroaalto- sulatus, sulatus +4°C:ssa ja sulatus +2l°C:ssa. Näyt- teet analysoitiin kemiallisin ja mikrobiologisin menetel- min välittömästi sulamisen jälkeen. Mikroaaltosulatus osoittautui muita menetelmiä paremmaksi (P<0.05). 415