Al-Qadisiya Journal For Engineering Sciences Vol. 2 No. ٢ Year 2009 ٥٣٢ THE ADVANTAGES OF PRGRAMMABLE LOGIC CONTROLLERS IN INDUSTRIES Muhanad Dhiya Hashim , Al Qadisiya University – Collage of Engineering Abstract In the industrial world the computers and microprocessors have become popular for use in automatic control systems, thus we have a new generation of control systems which is called Programmable Logic Controller . These systems has plenty of control components (Timers, Counters, Registers, Comparator, Clock, …)inside the software of the PLC instead of the classical components , and the contacts of the relay ( Normal open and Normal close ) have been replaced by the orders which are saved in memory. The updating and modification of the system is easy to obtain by rewriting the program.Another advantage of the PLC is that the input of the PLC is photo isolated and shielded , but the most important advantage is that we can test the program befor it's using in the machine by using the simulator which is included with the PLC program . Keyword: Programmable Logic Controller , Ladder Language , Function Black Diagram , Structured Text , Insturction List , secquential Function Chart . ������� �� ���� ������ ������ ����� P�ء ه��Q � (�����O ه/��R آ��0�ء–(0/ Rد���� ا R�)�O–R�� آ��R أ 0/ ������ $�" ��( 1��� �"��� � )��������9� >� �� !E�"� )* !����� ��"��0�� � � ��������� > �3�+� L�5 !��39� � ��+� )* !EM�"� '� ���">� �� E���� )�� � H����� )6%��� >� �� !E�"� ��+� )�� � )��������9� ���;� �M�� ���3 �M� :�� � �MMM >� �� ����� '� ���� �� ) ���/4�� . � � �0� . = E9� ��"+� . �����6�� . ��/��� �����.(..... 1��M�� ������� ��MMMMM+��� +� =�E3� �� �;� ��� ���+ >� � �� ������ '� �����+N� ������� ��� O��� ��� �6�MM �M�� )�� > �� )* ����3�+� �6��+M ����6� !�%�+� ��. '� H������ =���� !���;� 1�� � 7��+� '� $�+� G��� !������ H������ $��0� � � >�� '� '��� . � �+3� $��6� >� >� �� ������ � ) �,� $E0�� ="���� . ���" � �� !EM�"� '+ MMMMM> � )M6%�� E�M�"� ��M�"��� KM� 7*��� )�� �� 7��% '� =���5� $�/ =������� 2�MMMM3� H������ 2 * =������ �� H����� M���� �� $%� $�� =�� )* 1���� H������ ����� 7��% '� =���� :� =� E� �� =*�,� ������;� G��� 1����M !��M�� �� '� H������ $�� � H������ =���� =���� �0� %��MMM,� 2�/ ��� 'E3�� H������ $�3. Al-Qadisiya Journal For Engineering Sciences Vol. 2 No. ٢ Year 2009 ٥٣٣ Introduction PLCs are used in many different industries and machines such as conveyor systems , Food processing machinery (e.g filling bottles with water or juice) , Auto assembly ( e.g auto Industry ), Fluid level control ( e.g water tanks ) , Mixing fluids (e.g paint Industries) , Motor Speed Control (Sanjeey Gupta &SC Sharma, 2005 ) . Well known PLC brands are Allen-Bradley , Mitsubishi-Electric , ABB Ltd, Honeywell , Siemens , Modicon , Omron , General Electric , Square-D (Telemecanique ) and Panasonic (a brand name of Matsushita ) , Less known PLCs that are programmable in BASIC are available from CUBLOC( Com File Technology ) or TRI-PLC ( Traingle - Research Int. ) ( Nebojsa Matic , 2001- PLC encyclopedia - PLC References , 2004 ) . The primary reason for designing the PLCs is to eliminate the large cost involved in replacing the complicated relay based machine control systems . The first PLC which is used in commercial production was named MODICON – 084 proposed by Bedford associates , Then other companies proposed computer based schemes (PDP-8 ) . When production requirements changed so did the control systems , this becomes very expensive when the change is frequent. The PLCs had to be : * Easily programmed by maintenance and plant engineers. * The lifetime must be long . * The programming changes easily performed. * The use of programming technique ( that replace mechanical parts with solid-state once) . * The use of microprocessors and CPU units . * Can send and receive varying voltages to allow us to enter the analog world. ( Mohammad Aqil , 2007 - Nebojsa Matic , 2001 – Imad AlSai'ad , 2005) . The program is a chain of instructions held in order to control the working procedure of a machine or a system, Writing the instruction of the program will be held by one of the languages especially made to the PLC ' by using the programs especially made to the PLC according to the manufacturing company , There are five basic languages : 1) Function block diagram ( FBD ) . 2) Ladder language ( LD ) . 3) Structured Text (ST -similar to Pascal programming ) . 4) Instruction list ( IL) . 5) Sequential Function Charts ( SFC ). ( Lipsky .Kevin , 1990 - PLC Languages ) After the writing of the program in one of the languages we sent this program from the personal computer to the memory in the PLC , this procedure contains translating the instructions to the machine Al-Qadisiya Journal For Engineering Sciences Vol. 2 No. ٢ Year 2009 ٥٣٤ language by using the compiler listed with software of the PLC. The language which is used in this research is LADDER language ( LADDER Logic Training Series , www.Automation Nc .com ) . Experimental Validation In this item we will consider Zelio SR1-B201BD ( PLC ) by Telemecanique : 1) From Edit menu we select the Zelio Mode , in this menu we can choose the language ( Ladder ) and logic inputs { 12 separate inputs } , output { 8 outputs every output has 4 conditions ( Q - contactor , Q - remote control , SQ - set , RQ- reset )} , intermediate cell , timers , counters , analog inputs , clock , text element . 2) From Edit menu we select the Free Mode ,In this menu we can choose the Program , Parameters , Simulation . 3) Transfer menu: in this menu we can choose PC- Modul {downloading program from PC to PLC } , Modul – PC ( downloading program from PLC to PC ) , Run Modul ( run the PLC ) , StopModul (stop PLC ) . 4) Mode menu: in this mode we can choose On line Monitoring Mode( Here the PLC is connected to the PC through the programming cable we can watch the performance of the PLC through the screen of the computer, Editing Mode ( when we want to disconnect the PLC from the PC ) . Case Study : A juice machine which works totally mechanical and we need to modify it so the control system will be electrical , Since relays , limit swiches are mechanical devices they also have a limited lifetime which required adequate maintenance schedules, troubleshooting was also quite tedious when so many relays are involved , also the size is important and the initial wiring.The machine shown in ( Fig . 1 ) that works during the week { from Saturday to Thursday }and the working time is form 8:00 to 13:00 and from 13:30 to 16:00 . The machine wash a bottle with water through valve V1(opens for 2 sec ) ,then the machine full the bottle with juice through valveV2 ( opens for 4 sec ), for each valve there is a sensor (S1) , (S2) respectively , after counting 12 botlles the machine stops ? Working Procedure When the bottle is at point A (Figure 1) and we press the start switch the motor now will work , when the bottle reach the sensor S1 the motor will stop and the valve V1 will work for a period (2 sec ) then the motor will work until the bottle reach sensor S2 then the motor will stop again and valve V2 will work for a period ( 4 sec ) then the motor will work , and so on…… The electrical and PLC wiring is shown in (Figure 2). Logic Form (Motor = 1) ….. {( Start=1) ANDA ( S1=1 ) ANDA ( S2=1 )} OR {( Start = 1) AND ( TW1.Out =1 ) AND ( S1= 1 )} OR {( Start =1) AND ( TW2.Out =1 ) AND ( S2=1 )}. Al-Qadisiya Journal For Engineering Sciences Vol. 2 No. ٢ Year 2009 ٥٣٥ ( Motor = 0)….. ( Start=0) OR {( Start = 1) AND ( S1=1) AND ( TB1.Out =1)} OR {( Start =1) AND (S2 = 1 ) AND ( TB2.Out =1 )} . The LADDER diagram will be as in Figure 3 . Now if we would like to control the switching time of the machine during the week ( from Saturday to Thursday ) so that the working time begins ( 8:00 ) until (13:00 ) and form ( 13:30 ) until ( 16:00 ) so we must activate the clock from the tool bar ( Edition ) of Zelio , here we have four channels (canal A,B,C,D ) as in the window below, by turning the power on ( on) the Zelio PLC will run every day except Friday as in ( Figure 4 ) . So if we have an emergency case or we need to stop the machine all we have to push the button ( Halt ) as in ( Figure 5 ) .The Ladder Diagram will be the same as Fig . 3 but it will have additions as in ( Figure 6 ) . Now if we need the machine to stop after counting 12 bottles ( Figure 6 ) ,we have to add a counter ( up ) fixed on ( 12 ) and sensor( S3 ) , the machine will start if we press the start and it will stop at sensor S1 for (2 sec.) then it will run until it reach sensor S2 the Motor will stop for ( 4 sec. ) and the motor will run again until the counter counts ( 12 ) bottles and the motor will stop after that so the worker can remove the package of a dozen of bottles , then he will start the machine again ( Figure 7 ). Logic Form (Motor = 1) ….. {( Start=1) ANDA ( S1=1 ) ANDA ( S2=1 )} OR {( Start = 1) AND ( TW1.Out =1 ) AND ( S1= 1 )} OR {( Start =1) AND ( TW2.Out =1 ) AND ( S2=1 )} OR {( Start = 1 ) ANDA ( Counter. Out =1 ) ANDA ( Stop = 1 )} . (Motor = 0) ….. ( Start=0) OR {( Start = 1) AND ( S1=1) AND ( TB1.Out =1)} OR {( Start =1) AND (S2 = 1 ) AND ( TB2.Out =1 )} OR ( Counter = 1 ) . The total electrical wiring will be as in ( Figure 8 ) and LADDER diagram as in ( Figure 9 ) . Results And Discussion By using PLC we have minimized the large number of electrical components (timers ,counters , clock) which can be used in the control panels and maintenance time and increase the life time of machine and the speed of processing ( using CPU ) so if we need to add or modify the procedure of work all we need is to rewrite the program in its new form in one of the languages of programming and reload it to PLC by using personal computer while the old method ( using electrical components) needs to modify the control panel ( adding new components and new design ) which will add extra costs and extra time . Conclusion 1. By using the PLCs we can have an adequate design to install the control components, time of installion, time of modification, time of maintenance. 2. All kinds of PLCs have the same procedure of work but they don’t have the same number of component which contains, type , reading – writing speed , response speed , number of inputs – outputs , number of jobs which PLC can operate , capacity so the user must know the specification of these types in order to choose the adequate PLC . Al-Qadisiya Journal For Engineering Sciences Vol. 2 No. ٢ Year 2009 ٥٣٦ 3.The classical structure ( hardwire logic ) is based on different kinds of component ( wires , timers , counters ) and it’s a solid state and inflexible and has many disadvantages such as repairing a control panel which can take a lot of time to find the broken part and even it take a lot of money, when we need to modificate the procedure of the machine. 4. In order to change the procedure of a machine we have to renew the program ( adding timers , counters and other applications which can the PLC apply ) . 5. The PLC s are designed to a different industrial overloads and temperature and they are protected from Jamming , and against short circuit. 6. In case of program overloaded we can recharge the program( loaded on a CD ) from the PC to our PLC by using the transfer – PC module in the tool bar of the device . 7. We can test the program before installing the PLC on position by using the simulator( which is placed in edition mode - Free mode in the tool bar of the device ) enclosed with the PLC. 8. This kind of PLCs called ( Compact ) and there are two kinds of PLCs more ( Modular, Intermediate ) but this kind has the advantage in case we have several machines so if one machine is out of order there is no need to stop all the machines only the broken one , and this kind of PLCs has the ability to add LOCAL EXPANSION which incraes the number of inputs and outputs without the need to buy a new PLC , also we can connect this kind of many of these PLCs with our PC or with an external mointer through the Net input . References 1. Fundamentals of PLC Final ( www.4 shared . com/PLC p.23 . ). 2. Introduction to PLC Controllers by Nebojsa Matic (www. mikro .com/en/books/plc book/plc book.htm ) . 3. Introduction to PLC- LADDER Logic part 1 ( www.4share .com/ plc / page 22) . 4. LADDER Logic Training Series [ Automation Technology Inc. Harrisburg. Nc (www.AutomationNc .com ) 5. PLC Languages ( www. Kronotech.com/PLC/Languages.htm) .. 6. PLC References [ Journal of Manufacturing Systems (November 1 2004 ) ] . 7. PLC (Imad al- Sai'ad & Samir Halawa , Al – Ulum center 2005 – Syria ) . 8. Programming PLC ( High technology Training Module) by Lipsky , Kevin [ ERIC – Education Resource Information Center (may 1990 Wisconsin IndianHead technical college)] . 9. Programmable Logic Controller product Research ( Novmber 2006 ) .. 10. Programmable Logic Controllers [ Carbide & Tool Journal ( www.allaboutcircuits.com/ vol_4/ chpt_6/6 .html ) ] . 11. Programmable Logic Controllers ITCE–Introduction to PLCs Chapter 1 by Mohammad Aqil [ Al-Azhar University – Faculty of Engineering & Information Technology 2007 ] . 12. Selection and Application of AdvancedControl Systems :PLC, CD and PC – Based system by Sanjeey Gupta &SC Sharma( Journal of scientific Industrial Research volume 64 number 4 April 2005 ) . Al-Qadisiya Journal For Engineering Sciences Vol. 2 No. ٢ Year 2009 ٥٣٧ Figure1 Figure 2 Al-Qadisiya Journal For Engineering Sciences Vol. 2 No. ٢ Year 2009 ٥٣٨ Figure 3 Al-Qadisiya Journal For Engineering Sciences Vol. 2 No. ٢ Year 2009 ٥٣٩ Figure 4 Figure 5 Al-Qadisiya Journal For Engineering Sciences Vol. 2 No. ٢ Year 2009 ٥٤٠ Figure 6 Figure 7 Figure 8 Al-Qadisiya Journal For Engineering Sciences Vol. 2 No. ٢ Year 2009 ٥٤١ Figure 9