Emergency (****); * (*): *-* This open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0). Copyright © 2016 Shahid Beheshti University of Medical Sciences. All rights reserved. Downloaded from: www.jemerg.com 83 Emergency (2016); 4 (2): 83-87 ORIGINAL RESEARCH Correlation between Central Venous Pressure and Inferior Vena Cava Sonographic Diameter; Determining the Best Anatomic Location Bahman Naghipour1, Gholamreza Faridaalaee2* 1. Department of Anesthesiology, Tabriz University of Medical Sciences, Tabriz, Iran. 2. Emergency Department, Maragheh University of Medical Sciences, Maragheh, Iran. *Corresponding Author: Gholamreza Faridaalaee, Emergency Department, Amiralmomenin Hospital, Amiralmomenin Avenue, Maragheh, Iran. Tel: 00989146677876 Email: gholamrezafaridaalae@yahoo.com Received: May 2015; Accepted: June 2015 Abstract Introduction: The correlation of central venous pressure (CVP) with inferior vena cava (IVC) sonographic diame- ter has been reported in several studies. However, few studies have attempted to find the best anatomic location of measurement. Therefore, the purpose of this study was determining the best anatomic location to find precise correlation between CVP and IVC diameter using transesophageal echocardiography (TEE). Methods: In the pre- sent diagnostic accuracy study, patients in need of central venous catheterization and TEE were enrolled. Maximum diameter of IVC were measured during expiratory phase of respiratory cycle at the level of diaphragm, 2cm above the diaphragm and at the point of entry into the right atrium using SonoSite TEE device. CVP was measured using an electronic transducer connected to the central venous line. The best location for sonography was determined via calculating and comparing area under the receiver operating characteristics (ROC) curve (AUC). Results: 39 patients were enrolled (53.8% female). Mean CVP was 6.8 ± 1.4 mmHg and 25 (64.1%) patients had normal CVP, while 14 (35.9%) showed elevated CVP (> 6 mmHg). Evaluating AUC showed that IVC diameter (p = 0.01), aorta diameter (p = 0.01) and IVC / aorta ratio (p = 0.004) had acceptable correlation with CVP. Point of entry of IVC into the right atrium with AUC of 0.98 (95% CI: 0.95 – 1.00) was the location of highest correlation with CVP. Conclu- sion: Based on the present findings, the IVC sonographic diameter and IVC / aorta ratio had acceptable correlation with CVP at the level of IVC entry into the right atrium. Keywords: Central venous pressure; vena cava, inferior; aorta, thoracic; echocardiography, transesophageal Cite this article as: Naghipour B, Faridaalaee G. Correlation between central venous pressure and inferior vena cava sonographic diameter; determining the best anatomic location. Emergency. 2016; 4(2):83-87. Introduction: ehydration is the main cause of morbidity and mortality in critically ill patients and assessment of intravascular volume status (IVS) is essential for their management (1, 2). However, diagnosis of de- hydration and intravascular volume loss is sometimes difficult (3). Some clinical signs and symptoms are as- sessed for determining IVS but they have low sensitivity and specificity (4). It could be determined by measuring peripheral blood pressure, but in many conditions, it does not reflect accurate intravascular volume status. Hypotension is detected in late stage of shock, especially when compensatory mechanisms fail (5). Central venous pressure (CVP) is one of the indices of IVS and early goals of goal-directed therapy approach (6, 7). A common and conventional procedure for measuring CVP is inserting a catheter in a central vein such as internal jugular, subcla- vian, and femoral veins. However, the major problem with this procedure is the probability of some dangerous and sometimes lethal complications such as arterial puncture, pneumothorax, hemothorax, misplacement in carotid artery, infection, and other rare complications such as cardiac tamponade etc. In addition, central ve- nous catheter insertion is a time consuming and invasive procedure (8-12). Recently, researchers and physicians have attempted to measure CVP with non-invasive pro- cedures such as ultrasonography, transthoracic echocar- diography, and transesophageal echocardiography (TEE). They have reported a correlation between so- nographic inferior vena cava (IVC) diameter and CVP (1, 9, 13-16). Donahue et al. found a direct correlation be- tween internal jugular vein sonographic diameter and CVP (17). However, few studies have attempted to find D This open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0). Copyright © 2016 Shahid Beheshti University of Medical Sciences. All rights reserved. Downloaded from: www.jemerg.com Naghipour et al 84 the best anatomic location and cut points. Therefore, the purpose of this study was determining the best anatomic location to find precise correlation between CVP and IVC diameter using TEE. Methods: Study design and setting In the present prospective cross-sectional study, the cor- relation of sonographic IVC diameter, aorta diameter, and IVC / aorta ratio with CVP were evaluated. Patients in need of catheterization and TEE who were referred to a teaching hospital in Tabriz, Iran, from 2013 to 2015 were enrolled. This study was approved by the Ethics Committee of Tabriz University of Medical Sciences. The patients or their relatives had signed the informed writ- ten consent form before initiation of the study and the researchers adhered to the principles of Helsinki decla- ration. Participants: Over the course of the study, all patients over 18 years old who needed central venous catheterization and TEE were included. Consecutive sampling was used and the patients’ need for catheterization and TEE was deter- mined by an independent cardiologist. Those who were prohibited from assuming a supine position (severe or- thopnea, intracerebral pressure rising), patients who had moderate-to-severe tricuspid regurgitation, conges- tive heart failure, broncho-pulmonary dysplasia, body mass index > 30, and renal and liver diseases were ex- cluded. Measurements: Central venous catheterization and TEE were done in the operating room. After central catheterization using Seldinger technique, CVP was measured using electronic transducer connected to the CV line inserted in the right internal jugular vein by central approach while the pa- tient was placed in a 15-degree Trendelenburg position (18). IVC and aorta diameter were measured using TEE (SONOS 5500; Philips Medical Systems, Andover, MA) and a 3.5 MHz probe. All the ultrasonographies were done by a trained cardiology fellow who was blind to the patients’ CVP. IVC and aorta diameter were measured at end-expiration and end-diastole in 2-dimensional long- axis mid-esophageal bicaval view. Measurements were done in the level of diaphragm, 2 centimeters above the diaphragm and at the point of entry into the right atrium and recorded in millimeter. All evaluations were done in the supine position. Statistical analysis Sample size was determined to be about 45 patients con- sidering minimum correlation coefficient of IVC diame- ter and CVP to be 0.48 with 95% confidence interval (CI) (α = 0.05) and 90% power (β = 0.1). Analyzes were done with SPSS 20. Spearman’s rank correlation test was used to determine the relationship between sonographic IVC diameter and CVP. Best index (IVC diameter, aorta diam- eter, or IVC / aorta ratio) and best measurement location (the level of diaphragm, 2cm above the diaphragm and at the point of entry into the right atrium) were deter- mined via calculating and comparing area under the re- ceiver operating characteristics (ROC) curve (AUC). Nor- mal CVP was considered 2-6 mmHg for this purpose (19). In all analyses, p < 0.05 was considered as signifi- cance level. Table 1: Baseline characteristics of the patients Variable Mean (SD) Median Minimum Maximum Age (year) 62.1 (5.8) 61 54 83 Weight (kg) 69.5 (11.0) 68 53 94 Height (cm) 161.3 (7.3) 160 145 178 SBP (mmHg) 110 (9.6) 110 95 130 DBP (mmHg) 63.8 (6.9) 63 45 80 HR (beat/min) 71.3 (12.4) 73 45 90 CVP (mmHg) 6.8 (1.04) 7 4 9 IVC diameter (mm) Point of entry into the right atrium 23.2 (3.6) 22 18 31 2cm above the diaphragm 18.6 (2.6) 19 12 23 Level of diaphragm 17.1 (3.4) 17 10 25 Aorta diameter (mm) Point of entry into the right atrium 24.6 (2.1) 25 21 29 2cm above the diaphragm 22.4 (1.6) 23 19 27 Level of diaphragm 21.3 (1.6) 21 19 27 IVC/Aorta ratio Point of entry into the right atrium 0.94 (0.09) 0.96 0.78 1.12 2cm above the diaphragm 0.83 (0.13) 0.86 0.52 1.05 Level of diaphragm 0.81 (0.16) 0.81 0.48 1.09 SBP: systolic blood pressure, DBP: diastolic blood pressure, HR: heart rate, CVP: central venous pressure, IVC: inferior vena cava. This open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0). Copyright © 2016 Shahid Beheshti University of Medical Sciences. All rights reserved. Downloaded from: www.jemerg.com 85 Emergency (2016); 4(2): 83-87 Results: Over the course of the study, 39 patients were included (53.8% male; mean age 62.1 ± 5.8 years). Baseline char- acteristics of the patients are summarized in table 1. Mean CVP was 6.8 ± 1.4 mmHg and 25 (64.1%) patients had normal CVP, while 14 (35.9%) showed elevated CVP (> 6 mmHg). The relationship of CVP with IVC and aorta diameter Table 2 shows the relationship of CVP with sonographic IVC diameter, aorta diameter, and IVC / aorta. As can be seen, CVP had a significant correlation with IVC diameter at the point of entry into the right atrium (r = 0.85; p < 0.001), 2cm above the diaphragm (r = 0.48; p = 0.002), and in the level of diaphragm (r = 0.85; p < 0.001). At the same time, aorta diameter showed a significant correla- tion with CVP at the point of entry into the right atrium (r = 0.68; p < 0.001) and 2cm above the diaphragm (r = 0.44; p = 0.005). IVC / aorta ratio also had a significant correlation with CVP at all 3 points. Comparing diagnostic values of IVC and aorta diam- eter Evaluation of area under the ROC curve showed that the best point for determining CVP was at the point of entry into the right atrium for IVC diameter (p = 0.01), aorta diameter (p = 0.01), and IVC / aorta ratio (p = 0.004) (fig- ure 1A-C). Therefore, to identify the best index among the 3, their area under the ROC curve was compared at this point (table 3 and figure 1-D). Based on the findings, IVC diameter (AUC = 0.98; 95% CI: 0.95-1.0) and IVC / aorta ratio (AUC = 0.96; 95% CI: 0.92-1.0) had higher di- agnostic values compared to aorta diameter (AUC = 0.89; 95% CI: 0.79-0.98) at this point (p = 0.01). Discussion: This study was conducted to find the precise anatomic location with the best correlation between CVP and IVC diameter, aorta diameter, or IVC/aorta ratio. Based on the present findings, the IVC diameters and IVC / aorta ratio had acceptable correlation with CVP. In addition, the point of IVC entry into the right atrium was the best anatomic location to estimate CVP. Ultrasound is a non- invasive, easy, available, and useful tool for assessment of volume status (20). Wiwatworapan et al. showed that when end-expiratory IVC diameter was lower than 10 mm, the CVP would be 10 cmH2O, (sensitivity 77% and specificity 91%) and when end-expiratory IVC diameter was 15 mm, CVP would be 15 cmH2O (sensitivity 90% Table 2: Correlation of CVP with IVC and aorta diameters, and IVC/Aorta ratio Index R 95 % CI P IVC Point of entry into the right atrium 0.85 0.73-0.92 <0.001 2cm above the diaphragm 0.48 0.19-0.69 0.002 Level of diaphragm 0.68 0.47-0.82 <0.001 Aorta Point of IVC entry into the right atrium 0.68 0.45-0.81 <0.001 2cm above the diaphragm 0.44 0.15-0.66 0.005 Level of diaphragm 0.15 -0.17-0.44 0.37 IVC/Aorta ratio Point of IVC entry into the right atrium 0.69 0.48-0.83 0.001 2cm above the diaphragm 0.43 0.16-0.68 0.007 Level of diaphragm 0.53 0.26-0.72 0.001 IVC: Inferior vena cava; CI: Confidence interval. Table 3: area under ROC curve of IVC and aorta diameters, and IVC/Aorta ratio in estimation of CVP Index AUC 95 % CI P IVC Point of entry into the right atrium 0.98 0.95-1.0 0.01 2cm above the diaphragm 0.78 0.62-0.93 Level of diaphragm 0.81 0.66-0.96 Aorta Point of IVC entry into the right atrium 0.89 0.79-0.98 0.01 2cm above the diaphragm 0.64 0.45-0.84 Level of diaphragm 0.53 0.45-0.84 IVC/Aorta ratio Point of IVC entry into the right atrium 0.96 0.92-1.0 0.004 2cm above the diaphragm 0.67 0.48-0.85 Level of diaphragm 0.80 0.66-0.94 IVC: Inferior vena cava; AUC: Area under curve; CI: Confidence interval. This open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0). Copyright © 2016 Shahid Beheshti University of Medical Sciences. All rights reserved. Downloaded from: www.jemerg.com Naghipour et al 86 and specificity 89%) (21). Baumann et al. measured CVP using ultrasound and concluded that although estima- tion of CVP by ultrasound is easy, but absolute values dif- fer from invasive measurements of CVP and IVC indices alone can’t be used to accurately estimate intravascular volume status (22). In line with our study, Arthur et al. reported a statistically significant correlation between IVC diameter and CVP (16). In addition, De Lorenzo et al. compared different anatomic locations such as subxiphoid, mid-abdomen and suprailiac to find best an- atomic location for calculating the correlation between CVP and IVC diameter. They reported that suprailiac view had better correlation with CVP compared to other anatomic locations but measurement of CVP using ultra- sound had low yield (23). Yet, some studies demonstrate that an increase or decrease in the collapsibility of IVC can be helpful in management of patients in poor condi- tion. Based on the findings of those studies, the combina- tion of absolute IVC diameter and collapsibility level, which is known as Caval index, is a better estimation of CVP compared to absolute IVC diameter and can be a good replacement for invasive tests (24-26). The mech- anism of this method is based on the fact that the nega- tive pressure generated while inhalation leads to an in- crease in venous return to heart and IVC collapse. While exhaling, venous return decreases and IVC diameter goes back to the basic state (25, 27, 28). In the present study, Caval index could not be assessed, as the ultraso- nography film could not be recorded in the device used. Therefore, it is recommended to take this into account in future studies. Another limitation of this study was the little sample size, yet the minimum power calculated for this study was 85%; so it seems that little sample size has not affected the results of this study. Conclusion: Based on the present findings, the IVC sonographic diam- eter and IVC / aorta ratio had acceptable correlation with CVP at the level of IVC entry into the right atrium. Acknowledgments: Authors would like to thank all the staff of operating A B C D Figure 1: Comparison of area under the curve of inferior vena cava (IVC) diameter (A), aorta diameter (B), and IVC / aorta ratio (C) in different points in estimation of central venous pressure and comparison between the three indices (D). P = 0.01 0 .0 0 0 .2 5 0 .5 0 0 .7 5 1 .0 0 S e n si ti v it y 0.00 0.25 0.50 0.75 1.00 1-Specificity AUC of IVC at right atrium= 0.98 AUC of IVC at 2 cm above diaphragm= 0.78 AUC of IVC diaphragm level=0.81 P = 0.01 0 .0 0 0 .2 5 0 .5 0 0 .7 5 1 .0 0 S e n si ti v it y 0.00 0.25 0.50 0.75 1.00 1-Specificity AUC of aorta at right atrium = 0.89 AUC of aorta at 2 cm above diaphragm= 0.64 AUC of aorta at diaphragm level=0.53 P=0.004 0 .0 0 0 .2 5 0 .5 0 0 .7 5 1 .0 0 S e n si ti v it y 0.00 0.25 0.50 0.75 1.00 1-Specificity AUC IVC/aorta at right atrium= 0.96 AUC of IVC/aorta at 2 cm above diaphragm= 0.67 AUC of IVC/aorta at diaphragm level= 0.80 P = 0.01 0 .0 0 0 .2 5 0 .5 0 0 .7 5 1 .0 0 S e n si ti v it y 0.00 0.25 0.50 0.75 1.00 1-Specificity AUC of IVC= 0.983 AUC of aorta= 0.89 AUC of IVC/aorta= 0.96 This open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0). Copyright © 2016 Shahid Beheshti University of Medical Sciences. All rights reserved. Downloaded from: www.jemerg.com 87 Emergency (2016); 4(2): 83-87 room in Shahid Madani Hospital. Conflict of interest: None Funding support: None Authors’ contributions: All authors passed four criteria for authorship contribu- tion based on recommendations of the International Committee of Medical Journal Editors. References: 1. Thanakitcharu P, Charoenwut M, Siriwiwatanakul N. Inferior vena cava diameter and collapsibility index: a practical non- invasive evaluation of intravascular fluid volume in critically- ill patients. J Med Assoc Thai. 2013;96:S14-22. 2. Control CfD, Prevention. Managing acute gastroenteritis among children: oral rehydration, maintenance, and nutritional therapy. Pediatrics. 2004;114(2):507. 3. Riccardi A, Chiarbonello B, Minuto P, Guiddo G, Corti L, Lerza R. Identification of the hydration state in emergency patients: correlation between caval index and BUN/creatinine ratio. Eur Rev Med Pharmacol Sci. 2013;17(13):1800-3. 4. Gorelick MH, Shaw KN, Murphy KO. Validity and reliability of clinical signs in the diagnosis of dehydration in children. Pediatrics. 1997;99(5):E6. 5. Pershad J, Myers S, Plouman C, et al. Bedside limited echocardiography by the emergency physician is accurate during evaluation of the critically ill patient. Pediatrics. 2004;114(6):e667-71. 6. Marcelino P, Fernandes A, Marum S, Ribeiro J. Non-invasive evaluation of central venous pressure by echocardiography. Rev Port Cardiol. 2002;21(2):125-33. 7. Rivers E, Nguyen B, Havstad S, et al. Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med. 2001;345(19):1368-77. 8. Gong P, Huang X-E, Chen C-Y, Liu J-H, Meng A-F, Feng J-F. Comparison of complications of peripherally inserted central catheters with ultrasound guidance or conventional methods in cancer patients. Asian Pac J Cancer Prev. 2012;13(5):1873- 5. 9. Jardim JM, Lacerda RA, Soares NdJD, Nunes BK. Evaluation of practices for the prevention and control of bloodstream infections in a government hospital. Rev Esc Enferm USP. 2013;47(1):38-45. 10. Kaye C, Smith D. Complications of central venous cannulation. BMJ. 1988;297(6648):572-3. 11. McGee DC, Gould MK. Preventing complications of central venous catheterization. N Engl J Med. 2003;348(12):1123-33. 12. Pivalizza EG, Gumbert SD, Marasigan B, Guzman-Reyes S. 'Evidence'for practice guidelines for central venous access? Anesthesiology. 2012;117(4):916-7. 13. Chen L, Kim Y, Santucci KA. Use of ultrasound measurement of the inferior vena cava diameter as an objective tool in the assessment of children with clinical dehydration. Acad Emerg Med. 2007;14(10):841-5. 14. Chen L, Hsiao A, Langhan M, Riera A, Santucci KA. Use of bedside ultrasound to assess degree of dehydration in children with gastroenteritis. Acad Emerg Med. 2010;17(10):1042-7. 15. Bailey JK, McCall J, Smith S, Kagan RJ. Correlation of internal jugular vein/common carotid artery ratio to central venous pressure: a pilot study in pediatric burn patients. J Burn Care Res. 2012;33(1):89-92. 16. Arthur ME, Landolfo C, Wade M, Castresana MR. Inferior vena cava diameter (IVCD) measured with transesophageal echocardiography (TEE) can be used to derive the central venous pressure (CVP) in anesthetized mechanically ventilated patients. Echocardiography. 2009;26(2):140-9. 17. Donahue SP, Wood JP, Patel BM, Quinn JV. Correlation of sonographic measurements of the internal jugular vein with central venous pressure. Am J Emerg Med. 2009;27(7):851-5. 18. Ely EW, Smith AC, Chiles C, et al. Radiologic determination of intravascular volume status using portable, digital chest radiography: a prospective investigation in 100 patients. Crit Care Med. 2001;29(8):1502-12. 19. Jeremias A, Brown D. Cardiac Intensive Care. 2 ed. Philadelphia: Elsevier Health Sciences; 2010. p. 384. 20. Zengin S, Al B, Genc S, et al. Role of inferior vena cava and right ventricular diameter in assessment of volume status: a comparative study: ultrasound and hypovolemia. Am J Emerg Med. 2013;31(5):763-7. 21. Wiwatworapan W, Ratanajaratroj N, Sookananchai B. Correlation between inferior vena cava diameter and central venous pressure in critically ill patients. J Med Assoc Thai. 2012;95(3):320-4. 22. Baumann UA, Marquis C, Stoupis C, Willenberg TA, Takala J, Jakob SM. Estimation of central venous pressure by ultrasound. Resuscitation. 2005;64(2):193-9. 23. De Lorenzo RA, Morris MJ, Williams JB, et al. Does a simple bedside sonographic measurement of the inferior vena cava correlate to central venous pressure? J Emerg Med. 2012;42(4):429-36. 24. Goldflam K, Saul T, Lewiss R. Focus On: Inferior Vena Cava Ultrasound. ACEP News. 2011;6:24-5. 25. Nagdev AD, Merchant RC, Tirado-Gonzalez A, Sisson CA, Murphy MC. Emergency department bedside ultrasonographic measurement of the caval index for noninvasive determination of low central venous pressure. Ann Emerg Med. 2010;55(3):290-5. 26. Sridhar H, Mangalore P, Chandrasekaran V, Manikam R. Caval Aorta Index and Central Venous Pressure Correlation in Assessing Fluid Status!“Ultrasound Bridging the Gap”. ISRN Emerg Med. 2012;2012:1-5. 27. Tayal V, Blaivas M. American College of Emergency Physicians: ACEP emergency ultrasound guidelines-2001. Ann Emerg Med. 2009;53:470-81. 28. Blehar DJ, Dickman E, Gaspari R. Identification of congestive heart failure via respiratory variation of inferior vena cava diameter. Am J Emerg Med. 2009;27(1):71-5.