Archives of Academic Emergency Medicine. 2019; 7 (1): e54 LE T T E R TO ED I TO R A Polyvinyl Chloride Eraser as a Surface Marker for Com- puted Tomography in Emergency Imaging; a Letter to Edi- tor Yuya Murakami1, Taihei Yamada1, Hiromichi Naito1∗ 1. Department of Emergency, Critical Care and Disaster Medicine, Okayama University Hospital, Okayama, Japan. Received: July 2019; Accepted: August 2019; Published online: 28 September 2019 Cite this article as: Murakami Y, Yamada T, Naito H. A Polyvinyl Chloride Eraser as a Surface Marker for Computed Tomography in Emer- gency Imaging; a Letter to Editor. Arch Acad Emerg Med. 2019; 7(1): e54. Dear Editor, In the wake of recent progress in computed tomography (CT) enabling to obtain high quality images within five minutes, CT scan has been widely used in emergency diagnostic radi- ology and is considered best suited for detection of patholo- gies, as well as assessing the location and extent of lesions in the emergency department. Emergency physicians often require confirmation of surface bruises or wounds coexisting with pathology on CT scan. Al- ternatively, they may want to confirm the presence or ab- sence of pathology in the painful lesion. The use of an ap- propriate surface marker on the skin surface of the painful lesion may enable them to identify areas of interest and safely reduce radiation exposure. CT skin markers detected as virtually artifact-free and opaque, particularly for mammography, have been commer- cially available from several healthcare companies, but these markers are expensive ($57-$86 USD) and may not be easily accessible. Most metal objects cause artifacts through mul- tiple mechanisms, including beam hardening, scatter, and Poisson noise, although some can be reduced using iterative reconstruction or by combining data from multiple scans (1). We found that a polyvinyl chloride eraser may be the best sur- face marker for CT marking applications. As shown in Figure 1, a polyvinyl chloride eraser is visualized as a high-density, artifact-free homogenous object on CT scan and can be used as a skin surface marker in the emergency setting. Interest- ingly, an eraser impacted in the nose of a five-year-old girl was reported to be identified as a calcified nodular mass by ∗Corresponding Author: Hiromichi Naito; Emergency Department, Crit- ical Care and Disaster Medicine, Okayama University Graduate School of Medicine Dentistry and Pharmaceutical Sciences, 2-5-1 Shikata-cho, Kita-ku, Okayama-shi, Okayama, 700-8558, Japan. Email: qq-nakao@okayama-u.ac.jp, naito05084@gmail.com, Tel: +81-86-235-7426, FAX: +81-86-235-7427. Figure 1: Computed tomography scan of the chest revealed corre- spondence of rib fracture (arrowhead) and pain location, marked with an eraser (arrow). CT, which was diagnosed as rhinoliths. Thus, an eraser is de- tected as a high-density and opaque object without artifacts (2, 3). In conclusion, a polyvinyl chloride eraser, inexpensive and easily available in the stationery section of retail stores, even in developing countries, can serve as a suitable surface marker for CT examination in an emergency setting to local- ize pathology from the skin surface. This study protocol was approved by ethical committee of Okayama University Hos- pital. 1. Appendix 1.1. Acknowledgements The staff members of Department of Emergency, Critical Care and Disaster Medicine, Okayama University Hospital This open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0). Downloaded from: http://journals.sbmu.ac.ir/aaem Y. Murakami et al. 2 are thanked for their cooperation in performance of this study. 1.2. Author’s contribution YM and TH performed the procedure. HN wrote the manuscript and edited the manuscript. All authors read and approved the final manuscript. Authors ORCIDs Hiromichi Naito: 0000-0002-7308-1716 Taihei Yamada: 0000-0001-7575-0365 1.3. Conflict of interest The authors declare that they have no competing interests. 1.4. Funding and support None. References 1. Wellenberg RHH, Hakvoort ET, Slump CH, Boomsma MF, Maas M, Streekstra GJ. Metal artifact reduction techniques in musculoskeletal CT-imaging. Eur J Radiol. 2018;107:60- 9. 2. Munoz A, Pedrosa I, Villafruela M. "Eraseroma" as a cause of rhinolith: CT and MRI in a child. Neuroradiology. 1997;39(11):824-6. 3. Mukherji SK, Castillo M, Sarangi S, Jacoway J. "Eraseroma" in a nasal cavity. AJR Am J Roentgenol. 1996;166(3):727. This open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0). Downloaded from: http://journals.sbmu.ac.ir/aaem Appendix References