Emergency. 2018; 6 (1): e5 REV I EW ART I C L E Applications of End-Tidal Carbon Dioxide (ETCO2) Moni- toring in Emergency Department; a Narrative Review Hamed Aminiahidashti1, Sajad Shafiee2, Alieh Zamani Kiasari3∗, Mohammad Sazgar1 1. Department of Emergency Medicine, Mazandaran University of Medical Sciences, Sari, Iran. 2. Department of Neurosurgery, Mazandaran University of Medical Sciences, Sari, Iran. 3. Departments of Anesthesiology and Critical Care, Mazandaran University of Medical Sciences, Sari, Iran. Received: November 2017; Accepted: December 2017; Published online: 15 January 2018 Abstract: Capnograph is an indispensable tool for monitoring metabolic and respiratory function. In this study, the aim was to review the applications of end-tidal carbon dioxide (ETCO2) monitoring in emergency department, mul- tiple databases were comprehensively searched with combination of following keywords: “ETCO2”, “emergency department monitoring”, and “critical monitoring” in PubMed, Google Scholar, Scopus, Index Copernicus, EB- SCO and Cochrane Database. Keywords: Capnography; Emergency service, hospital; exhalation; carbon dioxide; monitoring, physiologic © Copyright (2018) Shahid Beheshti University of Medical Sciences Cite this article as: Aminiahidashti H, Shafiee S, Zamani Kiasari A, Sazgar M. Applications of End-Tidal Carbon Dioxide (ETCO2 ) Monitoring in Emergency Department; a Narrative Review. 2018; 6(1): e5. 1. Introduction C apnometry, measuring the concentration of carbon dioxide (CO2) in the atmosphere, was used for the first time during World War II as a tool for monitor- ing the internal environment (1). It was used in medicine for the first time in 1950 to measure the amount of CO2 exhaled during anesthesia. However, it was not used in practice until the early 1980s and with development of smaller machines, capnometry officially entered the anesthesia field (2, 3). There are two types of capnograph, “side stream” and “main- stream” (4) . In the “mainstream” technique, sampling win- dow is in the ventilator circuit and measures CO2, while in the “side stream”, the gas analyzer is located out of the ven- tilator circuit. In both types, gas analyzer uses infrared radi- ation, mass or Raman spectra and a photo acoustic spectra technology (1, 4). Flow measurement equipment is used in volumetric capnograph. Colorimetric CO2 detector is an example of mainstream form. These devices have a pH sensitive indicator, which changes color in inspiration and expiration. These color ∗Corresponding Author: Alieh Zamani Kiasari, Intensive Care Unit, Imam Khomeini Hospital, Amirmazandarani Bolivar, Sari, Iran. Tel: 09111517833 Email: Aliehzamani@yahoo.com. changes are in response to CO2 concentration changes. In the presence of a small amount of CO2, the device has a base color, which changes gradually with increase in CO2 concen- tration (5). A normal capnograph (Figure 1) has a square-wave pat- tern, which begins in inspiratory phase (peak expiratory CO2 (PECO2) = 0 mmHg) and will continue until the expiratory phase (6). Phase 0 (inspiratory phase): Happens suddenly with an inspiration. The expiration phase includes three-phases: Phase I (latency phase): Beginning of expiration, represents anatomical dead space of the respiratory tract and is not discernible from the inspiratory phase before it (PECO2 = 0 mmHg), Phase II: A very rapid increase in PECO2, which represents exhalation of mixed air. Phase III (Plateau phase): Reflects the alveolar expiratory flow (a small increase in PECO2), which happens the peak at the end of tidal expiration (ETCO2). In this phase PECO2 is close to alveolar carbon dioxide tension (PACO2). Emergency physicians are always looking for a non-invasive, reliable instrument to detect life-threatening conditions in patients. One of the methods that have been suggested recently in the emergency department is capnography or ETCO2 monitoring. This study aimed to review the applica- tions of ETCO2 monitoring in emergency department. This open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0). Downloaded from: www.jemerg.com H. Aminiahidashti et al. 2 2. Evidence Acquisition A review of the literature was performed in November 2017 to find all previously published articles that included ETCO2 application in the emergency department. The review was done in multiple electronic databases (PubMed, Google Scholar, Scopus, Index Copernicus, EBSCO and Cochrane Database) using key words including ETCO2, emergency department monitoring, and critical monitoring, searching for articles published between 1966 and 2017. In addition, all references cited in these studies were searched for the keywords. All clinical trials, case reports, case series and meta-analyses were reviewed regarding their content. In the initial search, 386 articles were found and 65 articles were eligible to be included in this review. 3. ETCO2 Applications 3.1. Cardio Pulmonary Resuscitation (CPR) ETCO2 concentration is a reliable index of effective heart compression during CPR, which is associated with cardiac output (7, 8). The first sign of the return of spontaneous circulation (ROSC) during CPR is increase in ETCO2, there- fore monitoring of ETCO2 provides very useful information to guide treatment during CPR (8-10). ETCO2 is a reliable in- dicator with a high prognostic value in determining the CPR outcome (11, 12) . Studies have shown that in patients who had ETCO2 of 10 mmHg or less, cardiac arrest was associated with death (13, 14). After 20 minutes of CPR, death occurs if ETCO2 is consistently below 10 mmHg, with 100% sensitiv- ity and specificity (15). ETco2 is more sensitive than cerebral oxygen saturations (rSO2) in ROSC prediction (16). 3.2. Airway assessment Confirmation of endotracheal intubation is vital in airway management in the emergency department, while there is no definitive diagnostic tool to verify correct intubation in emergency rooms (17). Recently, capnography was used as the gold standard for confirming the correct location of the endotracheal tube (18, 19). Colorimetric ETCO2 is a safe, reli- able, simple and portable tool to determine the proper place- ment of endotracheal tube in patients with stable hemody- namic and it is very useful when a capnograph is not avail- able (20) . However, when patients have a bag or mask ven- tilation or consume carbonated beverages or antacids it can cause a false positive result, yet it usually indicates the true result after 6 breaths (21). The use of sodium bicarbonate leads to a higher level of ETCO2 for 5 to 10 minutes (22). During a cardiac arrest, which leads to decrease in tissue- pulmonary CO2 transportation, capnography can show a correct intubation as a wrong one (false negative)(23). Figure 1: Diagram of a normal capnogram that includes the inspi- ratory and expiratory phase. 3.3. Procedural sedation and analgesia Capnography is an effective method to diagnose early respi- ratory depression and airway disorders, especially during se- dation, leading to a reduction in serious complications (23, 24). Capnography provided more safety in monitoring pa- tients during sedation. Oxygen prescription does not have an effect on respiratory function parameters evaluated by capnography (25). It shows impaired airway function sooner than any other device, 5 to 240 seconds earlier than pulse oximetry (26, 27). Capnography is more sensitive than clini- cal evaluation in diagnosis of respiratory dysfunction, for in- stance, in many cases where apnea was experienced during sedation, doctors at the bedside did not recognize the apnea but capnography could identify it (28). 3.4. Pulmonary disease 3.4.1. Obstructive pulmonary disease In obstructive airway diseases, hypoventilation can cause shortness of breath and hypercarbia (29). There is a rela- tionship between ETCO2 and partial arterial carbon diox- ide (PaCO2) in patients with acute asthma in the emergency department (30, 31). Capnography is dynamic monitoring of patients with acute respiratory distress conditions such as asthma, chronic obstructive pulmonary disease (COPD), bronchiolitis, and heart failure (32). Bronchospasm is associ- ated with a prolonged expiratory phase (E1, E2, E3) in capno- gram (Figure 1) in patients with obstructive diseases such as COPD (32, 33). Changes in ETCO2 and expiratory phase slope correlated with (E1, E2, E3) forced expiratory volume in 1 second (FEV1) and Peak expiratory flow rate (PEFR) (32, 34). ETCO2 is an indispensable tool in assessing the severity of obstructive respiratory disease in the emergency depart- ment. ETCO2 is higher in patients with COPD exacerbation who are admitted to the hospital compared to those who are discharged from the emergency department (35). 3.4.2. Pulmonary embolism In thromboembolism, ETCO2 is significantly lower than nor- This open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0). Downloaded from: www.jemerg.com 3 Emergency. 2018; 6 (1): e5 mal due to the reduction of pulmonary perfusion and in- creased alveolar dead space that reduces the amount of CO2 exhaled from the lungs, so venous carbon dioxide pressure (PvCO2) increases and all of these changes lead to an in- crease in arterial CO2-ETCO2 gradient (36). This helps in correctly diagnosing pulmonary embolism, especially silent pulmonary embolism (37). Volumetric capnography is used for monitoring of thrombolysis in large pulmonary embolism (38). The average value of ETCO2 and decrease in PCO2 / PO2 pressure for 30 seconds correlates with clinical probability or rule out of pulmonary embolism (39). 3.5. Heart failure Rapid differentiation of heart failure as the cause of dyspnea from other respiratory causes, is very important for choos- ing an appropriate therapy (40). Sometimes distinguishing COPD / asthma exacerbation and acute heart failure is very difficult, especially when both exist together, and treatment decisions in this situation are very complex (41). ETCO2 in patients with cardiac causes is markedly different from patients with respiratory distress due to obstructive causes. ETC02 level > 37 mmHg was not observed in any patient with heart failure, although ETC02 level > 37 mmHg has a slight sensitivity for diagnosis of COPD / asthma (42, 43). ETCO2 level during cardiopulmonary exercise testing in pa- tients with heart failure has high prognostic value for cardiac events (44, 45). N-Terminal Pro- brain Natriuretic Peptide on the side of quantitative capnography is very useful in early diagnosis and treatment of patients with acute dyspnea (res- piratory or cardiac causes) in emergency departments. The widespread use of quantitative capnography can be benefi- cial in everyday work for emergency physicians (46). 3.6. Shock Hypotensive shock is a clinical feature for many diseases and is related to high mortality rate in emergency departments. Emergency physicians continuously strive to find new ways to diagnose early-stage shock to start treatment as soon as possible (47). Capnography is considered as a simple and non-invasive method to detect and estimate shock intensity in the early stage (48, 49). ETCO2 is known to be decreased in volume-related hypotensive states (50). ETCO2 has a cor- relation with blood pressure, serum lactate and base excess. In early-stage shock that is linked to reduced cardiac output, the amount of ETCO2 significantly decreases. This is due to decreased blood flow in the pulmonary artery during the car- diac output reduction, which disrupts ventilation perfusion ratio. With increase in shunt ETCO2 level decreases, while PaCO2 does not change (51, 52). With decrease in blood pres- sure, ETCO2 drops and PaCO2-ETCO2 gradient increases (53, 54). There is a correlation between the amount of dehydra- tion and the amount of sodium bicarbonate and ETCO2, and ETCO2 can be used as a simple and non-invasive indicator for determination of dehydration (55). 3.7. Metabolic disorder Carbon dioxide (CO2) is one of the final products of metabolism and is transferred to lungs through the blood circulation and transmitted through respiratory system, so exhaling CO2 reflects the body’s metabolic status (56, 57). ETCO2 is a fast, inexpensive and non-invasive indicator to estimate the amount of HCO3- bicarbonate and PaCO2 in emergency and critical situations (58). Due to the direct con- nection between ETCO2 and HCO3, ETCO2 is a predictor of metabolic acidosis and mortality, so capnograph as a screen- ing tool for metabolic acidosis is very useful in the emergency department (59) . ETCO2 can be recommended as a nonin- vasive method for determination of metabolic acidosis and can be used to detect early metabolic acidosis in patients with spontaneous breathing, however, ABG should be used as the gold standard for diagnosis and management of treat- ment (60). 3.7.1. Diabetic keto acidosis (DKA) Patients with diabetes mellitus are at increased risk of ma- jor and disabling complications, one of the most important of which is DKA (61). The Direct linear relationship between ETCO2 and HCO3 is useful in prediction of acidosis. It was shown that there is no DKA diagnosis when ETCO2 > 36, and there is DKA diagnosis when ETCO2 ≥ 29. ETCO2 30 to 35 is considered as the cut –point, so it is clinically useful in di- agnosis of acidosis (62, 63). In addition, a low PaCO2 level is correlated with increased risk of cerebral edema in children with DKA (64). Thus, according to the relationship between ETCO2 and PaCO2, capnography can be used to identify in- dividuals with high risk of cerebral edema (62). When the pa- tient’s glucose is above 550 mg/dl, ETCO2 is a useful tool to rule out the DKA (65). 3.7.2. Gastroenteritis Among children with diarrhea and vomiting, ETCO2 is inde- pendently correlated with serum HCO3 concentration. This is a non-invasive index for measuring the severity of acidosis in patients with gastroenteritis (66). ETCO2 can be used to estimate HCO3 in many emergency situations(58). 3.8. Trauma End-tidal carbon dioxide cannot be used to rule out severe injury in patients meeting the criteria for trauma care. ETCO2 ≥30 mmHg may be associated with increased risk of traumatic severe injury (67). There is a reverse relationship between pre-hospital ETCO2 and traumatic mortality rates, so ETCO2 can be used to improve triage and also helps the emergency medical service staff in planning for the transfer of patients to the appropriate trauma center (68). Low ETCO2 has a strong association with shock in patients with This open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0). Downloaded from: www.jemerg.com H. Aminiahidashti et al. 4 trauma and suggests the severity of the patient’s condition in the first 6 hours of admission (69). 4. Conclusion: ETCO2 is used in the emergency department as an indicator for measurement in many clinical situations. Capnography is a non-invasive and accurate method to measure ETCO2 and can help emergency physicians in some critical situations. Although this is not used in many emergency situations and it is not used routinely in the emergency department, its ap- plication is increasing in many emergency situations, such as patients undergoing mechanical ventilation, procedural se- dation and analgesia, pulmonary disease, heat failure, shock, metabolic disorder and trauma. This means that capnogra- phy must be considered as an essential tool in emergency department, however, more researches are needed to evalu- ate its application in specific clinical conditions and diseases. 5. Appendix 5.1. Acknowledgements None. 5.2. Author’s Contributions Conception and design, collection of data and writing of the manuscript: Hamed Aminiahidashti; Conception and de- sign, and data interpretation: Mohammad Sazgar and Sajad Shafiee; Conception and design, and critical revision of the manuscript: Alieh Zamani Kiasari. 5.3. Funding Support None. 5.4. Conflict of Interest We declare no conflict of interest with any financial organi- zation regarding the material discussed in the manuscript. References 1. O’Flaherty. Capnography: principles and practice. Lon- don: BMJ Publishing Group. 1994. 2. Smalhout B KZ. An atlas of capnography. Amsterdam: Kerchebosch-Zeist,. 1981. 3. M W. Respiratory monitoring: a ten year perspective. J Clin Monit. 1990;6:217-25. 4. Block FE Jr MJ. Sidestream versus mainstream carbon dioxide analyzers. J Clin Monit. 1992;8(2):139-41. 5. Garey DM WR, Rich W, Heldt G, Leone T, Finer NN. T idal volume threshold for colorimetric carbon dioxide detectors available for use in neonates. Pediatrics ; 1. 2008;21(6):1524-7. 6. Berengo A C. Single-breath analysis of carbon dioxide concentration records. J Appl Physiol. 1961;16:522-30. 7. Falk JL RE, Weil MH. End-tidal carbon dioxide concentra- tion during cardiopulmonary resuscitation. N Engl7 Med 1989;318:607-11. 8. Garnett AR OJ, Gonzalez ER, Johnson EB. End-tidal car- bon dioxide monitoring during cardiopulmonary resus- citation. JAMA. 1987;257:512-5. 9. Ahrens T ea. End-tidal carbon dioxide measurements as a prognostic indicator of outcome in cardiac arrest Am J Crit Care. 2001;10:391-8. 10. Ornato JP GE, Garnett AR, Levine RL, McClung BK. Ef- fect of cardiopulmonary resuscitation compression rate on end-tidal carbon dioxide concentration and arterial pressure in man. Crit Care Med. 1988;16:241-5. 11. Cantineau JP ea. End-tidal carbon dioxide during cardiopulmonary resuscitation in humans presenting mostly with asystole: A predictor of outcome. Crit Care Med. 1996;24:791-6. 12. Pokorna M AM, Necas E. End tidal CO2 monitoring in condition of constant ventilation: a useful guide during advanced cardiac life support. Prague Med Rep. 2006;107 (3):317-26. 13. Callaham M BC. Prediction of outcome of cardiopul- monary resuscitation from end-tidal carbon dioxide con- centration. Crit Care Med. 1990;18:358-62. 14. Cantineau JP MP, Lambert Y, Sorkine M, Bertrand C, Du- valdestin P. Effect of epinephrine on end-tidal carbon dioxide pressure during prehospital cardiopulmonary re- suscitation. Am J Emerg Med. 1994;12:267- 70. 15. Levine RL WM, Miller CC. End-tidal carbon dioxide and outcome of out-of-hospital cardiac arrest. N Engl J Med. 1997;337:301-6. 16. Cournoyer A, Iseppon M, Chauny JM, Denault A, Cossette S, Notebaert E. Near-infrared Spectroscopy Monitoring During Cardiac Arrest: A Systematic Re- view and Meta-analysis. Academic Emergency Medicine. 2016;23(8):851-62. 17. Ma G DD, Schmitt J, Vilke GM, Chan TC, Hayden SR. the sensitivity and specificity of transcricothyroid ultra- sonography to confirm endotracheal tube placement in a cadaver model. J Emerg Med. 2007 32(4):405-7. 18. Turle S SP, Nicholson S, Callaghan T, Shepherd SJ. Avail- ability and use of capnography for in-hospital cardiac ar- rests in the United Kingdom. Resuscitation. 2015 94:80-4. 19. S G. Comparison of three different methods to confirm tracheal tube placement in emergency intubation. Inten- sive Care Med. 2002;28:701-4. 20. Goldberg JS RP, Zehnder JL, Sladen RN. Colorimetric end- tidal carbon dioxide monitoring for tracheal intubation. This open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0). Downloaded from: www.jemerg.com 5 Emergency. 2018; 6 (1): e5 Anesth Analg. 1990 70(2):191-4. 21. Garnett AR GC, Gervin AS. Capnographic waveforms in esophageal intubation: Effect of carbonated beverages. Ann Emerg Med. 1989;18:387-90. 22. Okamoto H HS, Kawasaki T, Okuyama T, Takahashi S. Changes in end-tidal carbon dioxide tension following sodium bicarbonate administration: Correlation with cardiac output and haemoglobin concentration. Acta Anaesthesiol Scand 1995;39:79-84. 23. B K. Capnography as a rapid assessment and triage tool for chemical terrorism. Pediatr Emerg Care. 2005;21:493- 7. 24. Adams L BS, Spurlock D Jr. Capnography (ETCO2), respiratory depression, and nursing interventions in moderately sedated adults undergoing transesophageal echocardiography (TEE). J Perianesth Nurs. 2015 30(1):14-22. 25. Mora Capin A MNC, Lopez Lopez R, Maranon Pardillo R. Usefulness of capnography for monitoring sedoanalge- sia: influence of oxygen on the parameters monitored. An Pediatr (Barc). 2014;80(1):41-6. 26. Burton JH HJ, Germann CA, Dillon DC. Does end- tidal carbon dioxide monitoring detect respiratory events prior to current sedation monitoring practices? Acad Emerg Med. 2006;13(500-504). 27. Deitch K MJ, Chudnofsky CR, Dominici P, Latta D. Does end tidal CO2 monitoring during emergency depart- ment procedural sedation and analgesia with propofol decrease the incidence of hypoxic events? A randomized, controlled trial. Ann Emerg Med. 2010;55(258-264). 28. Soto RG FE, Vila H Jr, Miguel RV. Capnography accurately detects apnea during monitored anesthesia care. Anesth Analg. 2004;99:379-82. 29. Hawkins NM PM, Pardeep SJ, et al. Heart failure and chronic obstructive pulmonary disease: diagnostic pit- falls and epidemiology. Eur J Heart Failure. 2009;11:130- 9. 30. Corbo J BP, Lahn M, et al. Concordance between capnog- raphy and arterial blood gas measurements of carbon dioxide in acute asthma. Ann Emerg Med. 2005;46(323- 327). 31. Cinar O AY, Arziman I, et al. Can mainstream end-tidal carbon dioxide measurement accurately predict the ar- terial carbon dioxide level of patients with acute dyspnea in ED. Am J Emerg Med. 2012;30(358-361). 32. Krauss B ea. Capnogram shape in obstructive lung dis- ease. Anesth Analg. 2005;100:884-8. 33. Krauss B HD. Capnography for procedural sedation and analgesia in the emergency department. Ann Emerg Med. 2007;50:172-81. 34. Yaron M PP, Hutsinpiller M, Cairns CB. Utility of the ex- piratory capnogram in the assessment of bronchospasm. Ann Emerg Med. 1996;28:403-7. 35. Dogan NO SA, Gunaydin GP, Icme F, Celik GK, Kavakli HS, Temrel TA. T. he accuracy of mainstream end-tidal car- bon dioxide levels to predict the severity of chronic ob- structive pulmonary disease exacerbations presented to the ED. Am J Emerg Med. 2014 32(5):408-11. 36. Anderson C T BPH. Carbon dioxide kinetics and capnog- raphy during critical care. Crit Care Med. 2000;4:207-15. 37. Taniguchi S IK, Sakaguchi Y. et al. Capnometry as a tool to unmask silent pulmonary embolism. Tohoku J Exp Med. 1997;183(4):263-71. 38. Verschuren F HE, Clause D, Roeseler J, Thys F, Meert P, Marion E, El Gariani A, Col J, Reynaert M, Liistro G. Volu- metric capnography as a bedside monitoring of throm- bolysis in major pulmonary embolism. Intensive Care Med. 2004 30(11):2129-32. 39. Kline JA HM. Measurement of expired carbon dioxide, oxygen and volume in conjunction with pretest probabil- ity estimation as a method to diagnose and exclude pul- monary venous thromboembolism. Clin Physiol Funct Imaging. 2006 26(4):212-9. 40. Stiell IG SD, Field B, Nesbitt LP, Munkley D, Maloney J, Dreyer J, Toohey LL, Campeau T, Dagnone E, Lyver M, Wells GA. OPALS Study Group. Advanced life support for out-of-hospital respiratory distress. N Engl J Med. 2007;356(21):2156-64. 41. Macchia A MS, Romero M, D’Ettorre A, Tognoni G. The prognostic influence of chronic obstructive pulmonary disease in patients hospitalised for chronic heart failure. Eur J Heart Fail. 2007;9(9):942-8. 42. Brown LH GJ, Seim RH. Can quantitative capnometry dif- ferentiate between cardiac and obstructive causes of res- piratory distress? Chest. 1998;113(2):323-6. 43. Grmec Åă GM, Klemen P, Cander D. Utility of the quan- titative capnometry (QC) and rapid bedside test for N- terminal pro-brain natriuretic peptide (pro-BNP) in the evaluation of respiratory distress in prehospital setting - preliminary results. J Emerg Med. 2007;33(3):322. 44. Arena R GM, Myers J. Prognostic value of end-tidal car- bon dioxide during exercise testing in heart failure. Int J Cardiol. 2007;117(1):103-8. 45. Arena R GM, Myers J, Chase P, Bensimhon D, Cahalin LP, Peberdy MA, Ashley E, West E, Forman. Prognostic value of capnography during rest and exercise in patients with heart failure. Congest Heart Fail. 2012;18(6):230-307. 46. Klemen P GM, Grmec S. Combination of quantitative capnometry, N-terminal pro-brain natriuretic peptide, and clinical assessment in differentiating acute heart fail- ure from pulmonary disease as cause of acute dyspnea in pre-hospital emergency setting: study of diagnostic ac- curacy. Croat Med J. 2009 50(2):133-42. 47. Emanuel RM P, Bryant Nguyenn H. A Comprehensive This open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0). Downloaded from: www.jemerg.com H. Aminiahidashti et al. 6 Study Guide. In Emergency Medicine. Tintinalli JE KG SJ, editor. New York: McGraw-Hill, Inc; 2004. 48. Weil MH NY, Tang W, Sato Y, Ercoli F, Finegan R, Grayman G, Bisera J. Sublingual capnometry: a new noninvasive measurement for diagnosis and quantitation of severity of circulatory shock. Crit Care Med. 1999 27(7):1225-9. 49. Rackow EC ONP, Astiz ME, Carpati CM. S. ublingual cap- nometry and indexes of tissue perfusion in patients with circulatory failure. Chest. 2001;120(5):1633-88. 50. Hemnes AR NA, Rosenbaum B, Barrett TW, Zhou C, Rice TW, Newman JH. Bedside end tidal CO2 as a screen- ing tool to exclude pulmonary embolism. EurRespir J. 2010;35(4):735-41. 51. Kheng CP RN. The use of end-tidal carbon dioxide moni- toring in patients with hypotension in the emergency de- partment. International Journal of Emergency Medicine. 2012;5(1):31. 52. DMello J BM. Capnography. Indian J Anesth. 2002;46(4):269-78. 53. Syed Shujat A AD, Abdul Raheem al Gattan. The relation- ship between end tidal carboon dioxide and urterial car- bon dioxide during controlled hypotensice anesthesia. Med principles pact. 2002;11:35-7. 54. Mahoori A HE, Mehdizadeh H, and Nanbakhsh N. the ef- fects of blood pressure variations on end-tidal and ar- terial CO2 pressure differences in patients undergoing coronary artery bypass graft. Journal of Iranian Society of Anesthesiology and Intensive Care. 2014;36(85):3-9. 55. Yang HW, Jeon W, Min YG, Lee JS. Usefulness of end-tidal carbon dioxide as an indicator of dehydration in pedi- atric emergency departments: A retrospective observa- tional study. Medicine. 2017;96(35). 56. BS K. Capnography outside the operating rooms. Anes- thesiology. 2013;118:192-201. 57. Rafael O CC, Sora K, et al. Monitoring Ventilation with Capnography. N Eng J Med. 2012;367. 58. Pishbin E AG, Sharifi MD, Deloei MT, Shamloo AS, Rei- hani H. The correlation between end-tidal carbon diox- ide and arterial blood gas parameters in patients evalu- ated for metabolic acid-base disorders. Electron Physi- cian. 2015;7(3):1095-101. 59. Kartal M EO, Rinnert S, Goksu E, Bektas F, Eken C. ET- COâĆĆ. a predictive tool for excluding metabolic dis- turbances in nonintubated patients. Am J Emerg Med. 2011;29(1):65-9. 60. Taghizadieh A, Pouraghaei M, Moharamzadeh P, Ala A, Rahmani F, Sofiani KB. Comparison of end-tidal car- bon dioxide and arterial blood bicarbonate levels in pa- tients with metabolic acidosis referred to emergency medicine. Journal of cardiovascular and thoracic re- search. 2016;8(3):98. 61. Losman ED. Weakness. In: A MJ, editor. Rosen’s Emer- gency Medicine. 87-92. Philadelphia: Mosby; 2010. 62. Fearon DM SD. End-tidal carbon dioxide predicts the presence and severity of acidosis in children with dia- betes. Acad Emerg Med. 2002 9(12):1373-8. 63. Soleimanpour H TA, Niafar M, Rahmani F, Golzari SE, Esfanjani RM. Predictive value of capnography for sus- pected diabetic ketoacidosis in the emergency depart- ment. West J Emerg Med. 2013;14(6):590-4. 64. Glaser NS BP, McCaslin I, et al. Risk factors for cerebral edema in children with diabetic ketoacidosis. N Engl J Med. 2001;344:264-9. 65. Chebl RB, Madden B, Belsky J, Harmouche E, Yessayan L. Diagnostic value of end tidal capnography in patients with hyperglycemia in the emergency department. BMC emergency medicine. 2016;16(1):7. 66. Nagler J WR, Krauss B. End-tidal carbon dioxide as a mea- sure of acidosis among children with gastroenteritis. Pe- diatrics ; 1. 2006 118(1):260-7. 67. Williams DJ, Guirgis FW, Morrissey TK, Wilkerson J, Wears RL, Kalynych C, et al. End-tidal carbon dioxide and occult injury in trauma patients: ETCO2 does not rule out severe injury. The American journal of emergency medicine. 2016;34(11):2146-9. 68. Childress K, Arnold K, Hunter C, Ralls G, Papa L, Silvestri S. Prehospital End-tidal Carbon Dioxide Predicts Mor- tality in Trauma Patients. Prehospital Emergency Care. 2017:1-5. 69. Stone ME, Kalata S, Liveris A, Adorno Z, Yellin S, Chao E, et al. End-tidal CO 2 on admission is associated with hemorrhagic shock and predicts the need for mas- sive transfusion as defined by the critical administration threshold: A pilot study. Injury. 2017;48(1):51-7. This open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0). Downloaded from: www.jemerg.com Introduction Evidence Acquisition Applications in Emergency department Conclusion: Appendix References