id	author	title	date	pages	extension	mime	words	sentence	flesch	summary	cache	txt
aiua-5562	Kaynar, Mehmet; Akand, Murat; Goktas, Serdar	A novel cannulation technique for difficult urethral catheterization	2016	2	.pdf	application/pdf	1164	59	47	Technique: The sheath tip of an intravenous catheter is cut off, replaced to the needle tip and pushed through the distal drainage side hole to Foley catheter tip, and finally with- drawn for cannulation. Foley catheter (Rüsch Gold TMGermany), and a scalpel are the necessary tools (Figure 1A).	cache/aiua-5562.pdf	txt/aiua-5562.txt