ARID ZONE JOURNAL OF ENGINEERING, TECHNOLOGY & ENVIRONMENT AZOJETE, March, 2019. Vol. 15(1):124-132 Published by the Faculty of Engineering, University of Maiduguri, Maiduguri, Nigeria. Print ISSN: 1596-2490, Electronic ISSN: 2545-5818 www.azojete.com.ng 124 ORIGINAL RESEARCH ARTICLE EFFECT OF DIFFERENT RISER HEIGHTS ON SPRINKLER IRRIGATION PERFORMANCE UNDER CONSTANT OPERATING PRESSURE I. A. Kuti1, T. A. Ewemoje2, B. A. Adabembe3, J. J. Musa1, S. C. Nwosu1 (1Department of Agricultural and Bioresources Engineering, Federal University of Technology, Minna, Nigeria 2 Department of Agricultural and Environmental Engineering, University of Ibadan, Ibadan, Nigeria 3 Department of Water Resources Management and Agro meteorology, Federal University Oye -Ekiti, Nigeria) *Corresponding Author: abykuti6@futminna.edu.ng ARTICLE INFORMATION Submitted 15 April 2018 Revised 15 September 2018 Accepted 19 September 2018 Keywords: Riser Height Operating Pressure Coefficient of Uniformity (CU) Distribution of Uniformity (DU) Sprinkler Irrigation ABSTRACT The study assessed the effect of different riser heights on the sprinkler irrigation performance to cater for the cultivation of taller crops and reduce water losses. A layout of 144 m2 was designed according to the length of mainline and lateral lines, and 36 catch cans were positioned in a grid of 2 m apart. The water caught in Cans were subjected to One-way ANOVA using the Tukey method in Minitab 17 Environment. The risers 4m, 3m and 2m, were significantly different because the means without any letter in common and concluded that some of the riser height have the different mean value of water caught in the catch cans. The results showed that as the riser height increased the mean application rate decreased. Also, the Coefficient of Uniformity (%) for riser height 2 m and 3 m were rated excellent. The Distribution of Uniformity (%) for 2 m and 3 m were rated excellent and fair. The study concluded that riser heights 2 m and 3 m had the optimum CU and DU at 1.6 bar (operating pressure) reduce water losses. The study suggested that sprinkler irrigation should be carried out in Gidan Kwano campus between 5:06 pm and 11:35 am. Also, wind direction should be established before the installation of sprinkler irrigation. © 2019 Faculty of Engineering, University of Maiduguri, Nigeria. All rights reserved. 1.0 Introduction Irrigation is viewed as the application of water to the soil to supply moisture for plant development and crop production (Yahaya, 2002). The need for irrigation arises when the frequency and amount of rainfall are insufficient to replenish the water required by the crop. In more arid regions, drought periods last longer in a year, and the seasonal rainfall is unable to meet crop needs during their growth period (Onwualu et al., 2006). Irrigation systems are classified as surface, sub-surface, sprinkler and drip irrigation (Onwualu et al., 2006). Sprinkler irrigation method is a pressurised irrigation system that consumes water from a different source and sprays it to the cultivated ground or earth as in the shape of rain using an enclosed system and under pressure (Nakayama and Bucks, 2012). Sprinkler irrigation is an adaptable means of supplying crops with common and uniform application of water over a broad range of topography and ground conditions (Nakayama and Bucks, 2012; Fanadzo et al., 2010; Evans and Sadler, 2008). Water distribution application in a sprinkler system is rich and more coherent than surface irrigation system (Yazar et al., 1999). A riser is one of the essential elements of a solid set mailto:abykuti6@futminna.edu.ng http://www.azojete.com.ng Arid Zone Journal of Engineering, Technology and Environment, March, 2019; Vol. 15(1):124-132. ISSN 1596-2490; e-ISSN 2545-5818; www.azojete.com.ng Corresponding author’s e-mail address: gbengailori@unilag.edu.ng 125 sprinkler system that influence the performance indicators of the Coefficient of Uniformity (CU) and Distribution Uniformity (DU) under specified environmental conditions. The CU has either a positive or negative effect on crop production (Okasha and Pibars, 2016). In summation, the weak CU and DU reduce the efficiency of sprinkler irrigation system. Water losses in sprinkler irrigation system occur due to evaporation and wind movement. Thus, there is a need to improve the functioning of the sprinkler irrigation system to bring down the cost of irrigation and water losses (Okasha and Pibars, 2016). Various surveys have indicated that the two common methods of determining sprinkler water uniformity are the coefficient of uniformity (CU) and distribution uniformity (DU). CU is the average deviation of the catch compared to the depth of the catch can, while DU compares the driest quarter of the field to the rest (Kara, 2008). Magagula (2013) reported that a catch-can test is a safe method of assessing the efficiencies of the existing sprinkler irrigation system. Bishaw and Olumana (2015) said that increase in riser heights between 2.5 m and 4.0 m lead to increase in sprinkler water uniformity and riser height 4 m produced optimum CU and DU at low wind speed. In view of this, the study aims at assessing the effect of different riser heights on the sprinkler irrigation performance to cater for taller crops and reduce water losses. 2 Materials and Methods 2.1 Study Area The study area is located within the Federal University of Technology, Minna, Gidan Kwano, Minna, Nigeria. It lies on latitude 9°32'04.1 N and longitude 6°26'53 E. The study was carried out on the land adjacent to the Department of Agricultural and Bio-resources Engineering Laboratory of the University. Gidan Kwano has two seasons namely rainy and dry. The annual maximum and minimum rainfall in the area is 1086 mm and 1309 mm, respectively, which occurs in May and ends in October. The yearly maximum and minimum temperature in the area is 37 °C and 19.3 °C respectively (Galadima, 2014). 2.2 Materials and Equipment 2.2.1 Water Pump The water pump moves water by pressure or suction from the reservoir to field, and its specification was presented in Table 1. Table 1:Water Pump Specifications Item Description Water pump model WP20X Type DF1 Connection diameter 50 mm Delivered volume 600 L/min Total head 26 m Power speed 3600 rpm 2.2.2 Sprinkler Irrigation system The sprinkler irrigation system has a main line of 6 m long with 50 mm diameter. Two lateral lines have 25 mm diameter with 3 m long each. It has different riser heights such as 1.5 m, 2 m, 3 file:///C:/Users/user/Downloads/azojete143/www.azojete.com.ng Kuti, et al. Effect of different riser heights on sprinkler irrigation performance under constant operating pressure AZOJETE, 15(1):124-132. ISSN 1596-2490; e-ISSN 2545-5818, www.azojete.com.ng 126 m, and 4 m with 2.5 mm diameter. Sprinkler irrigation system conveys water from the reservoir through the main and lateral line to the nozzle which sprays the water in the form of rain to the field. 2.2.3 Sprinkler Heads The sprinkler head sprays the water in the form of raindrops to the area. The specifications, characteristics and manufacturers details of the pressure, spraying radius, nozzle diameter and discharge of the four sprinkler heads were shown in Table 2. Table 2: Sprinkler Head Manufacturers’ Specifications Specification Comments/remarks Pressure 0.5 – 4.0 Bar Spraying Radius 3.0 – 16.5 m Nozzle Diameter 5.0+2.5 mm (7.5 mm) Flux/ Discharge 6.8-32.4 L/min Size ¾ inches Operation Capacity 360º full circle coverage Model RC130 zinc/brass 2.2.4 Catch Cans The diameter, height and volume of the catch cans were 84 mm, 130 mm and one litre respectively. 2.2.5 Water Hose and Siphon Tube Siphon tube sucks water from the tank to the pump impeller. Water hose conveys water from the pump to the mainline. The hose connected at the other end of the impeller to the main line which was held firmly by a clip to prevent leakages. 2.2.5 Tape A 50 m tape was used to measure the layout and the spacing of the catch cans. 2.2.6 Volumetric cylinder The cylinder was used to measure the water caught in the catch cans. It has a capacity of 500 cm3. 2.2.7 Marking pegs Pegs were used to map out the area and grid system. 2.2.8 Stopwatch A stopwatch was used to measure the time it takes the sprinkler head to fill the container. 2.2.9 Pipe Wrenches Pipe Wrenches was used to screw in the laterals into the main line and the risers into the laterals. 2.2.9 Cup Anemometer Cup anemometer was used to measure wind speed and direction. 2.2.9 Portable Thermo-hygrometer Portable Thermo-hygrometer was used to measure the temperature and humidity of the area http://www.azojete.com.ng Arid Zone Journal of Engineering, Technology and Environment, March, 2019; Vol. 15(1):124-132. ISSN 1596-2490; e-ISSN 2545-5818; www.azojete.com.ng Corresponding author’s e-mail address: gbengailori@unilag.edu.ng 127 2.3 Methods 2.3.1 Experimental description and Design Layout Field evaluation was carried out at Agricultural and Bio-resources Department, Federal University of Technology, Minna. The field had an area of 144 m2 (12 m by 12 m). The vegetation of the field was cleared in line with Osie (2009) and mapped out with pegs to form a grid as shown in Figure 1. Sprinkler compositions used were different riser height (such as 1.5 m, 2.0 m, 3.0 m and 4.0 m), pump, siphon tube, rubber hose, 36 catch cans, four sprinkler nozzles (model RC130), one main line (6 m in distance and 50 mm in diameter) and two laterals (6 m in length and 25 mm in diameter). The water pump has two impeller hoses which included a siphon tube and a rubber hose. The rubber hose was attached or connected to the mainline while the siphon tube was attached water tank as shown in Figure 1. These components assembled such that the laterals were spaced 3 m apart on the main line. In summation, the catch cans were spaced 2 m apart along the grid. The 36 Catch Cans estimated according to the area of the field Figure 1: Experimental view of sprinkler set up, the arrangement of catch cans on the grid and design layout 2.3.2 Operation of Sprinkler System Performance The operating pressure of the water pump adjusted via a pressure gauge and pitot tube. The Pitot tube was held at 3 mm from the nozzle head and recorded with the operating pressure. In the trial test, the operating pressure and flow rate were adequately controlled in this experiment. The speed and direction of the wind are measured every 15 minutes at height 2m with cup anemometer. At the end of the trial, the amount of water accrued in each catch cans was measured with cylinders (mL), and the procedures were repeated for each sprinkler nozzle as described by Kara et al. (2008). file:///C:/Users/user/Downloads/azojete143/www.azojete.com.ng Kuti, et al. Effect of different riser heights on sprinkler irrigation performance under constant operating pressure AZOJETE, 15(1):124-132. ISSN 1596-2490; e-ISSN 2545-5818, www.azojete.com.ng 128 2.4 Calculation of Basic Parameters 2.4.1 Evaporation and wind drift losses In sprinkler irrigation, water losses came from the nozzle to the irrigated areas due to the wind in the form of water drift and direct evaporation from the nozzle to the soil (Molle et al., 2012). Because of this, it is essential to determine evaporation and wind drift losses as described by Bishaw and Olumana (2015). E =[1.98 (D)−0.72 + 0.22 (Es – Ea)0.63 + 3.6 x 10−4(H)1.16 + 0.14 (U)0.7]4.2 (1) where: E = Evaporation and wind drift, per cent D = Nozzle diameter, m H = Riser height, m U = Wind velocity, m/s = Vapor pressure deficit, kPa Vapour pressure deficit is a predominant factor that affects evaporation from the sprinkler sprays. It is important to determine the vapour pressure deficit affecting the evaporation of the water from the nozzle (Bavi et al., 2009). The vapour pressure deficit was determined as follows: Es – Ea = 0.61 exp [17.27 � �+237.3 ] (1 − RH) (2) where, T = Air temperature, °C RH = Relative humidity, fraction. The evaporation and drift losses were determined for different riser height as recommended by Smajstrla and Zazueta (1994). (3) where, E = Evaporation and drift losses, % D = Nozzle diameter, m H = Riser height, m U = Wind velocity, m hr-1 RH = Relative humidity, % T= Air temperature, °C http://www.azojete.com.ng Arid Zone Journal of Engineering, Technology and Environment, March, 2019; Vol. 15(1):124-132. ISSN 1596-2490; e-ISSN 2545-5818; www.azojete.com.ng Corresponding author’s e-mail address: gbengailori@unilag.edu.ng 129 2.4.2 Christiansen’s Coefficient of Uniformity (CU) The coefficient of uniformity (CU) was determined as follows: CU % = 100(1 − the standard deviation of the water in the catch can mean of water in the catch can ) (4) 2.4.3 Distribution Uniformity (DU) The distribution uniformity (DU) was calculated as follows: DU % = 100 × ( an average low quarter of water in the catch can the average total of water in the catch can ) (5) 2.4.4 Mean Application Rate (MAR) The mean application rate (MAR) was determined as follows: I = q Sm × Sl × 100 (6) I= mean application rate is (m hr-1) q = Sprinkler discharge (m3 hr-1), Sl = Sprinkler spacing (m), Sm = lateral spacing (m). 2.5 Data Analysis The quantity of water measured in each riser were subjected to One-way ANOVA with multiple comparisons in Minitab 17 Environment. The amounts of water caught in the Cans were used to compute the Coefficient of Uniformity, Distribution Uniformity and Mean Application Rate of the sprinkler irrigation system. The results are presented in Tables and charts. 3. Results and Discussion 3.1 Determination of the volume of water Caught in the Catch Cans The evaporation and wind drift losses range between 5.22% to 10.2% which was in line with the work of Okasha and Pibars (2016). The amount of water determined in each riser was shown in Table 3. In a riser 1.5, the amount of water computed in the catch-can equal 799 ml. Also, the amount of water estimated in riser 2 was 632 ml. The amount of water calculated at riser 3m was 745 ml. The riser 4m has a total amount of 874 ml. The mean application rate for each riser 1.5, 2, 3 and 4 was 8.56 mm hr-1, 7.76 mm hr-1, 7.56 mm hr-1 and 6.76 mm hr-1 respectively as shown in Table 3. The study revealed that as the riser height increases the mean application rate decreases because the evaporation and drift losses also increase as indicated in Table 3. This study agrees with the work of Bishaw and Olumana (2015). The riser heights 4.0 m, 3.0 m and 1.5 m have the highest depth of water, whereas 2.0 m has the lowest volume of water caught in the catch cans as shown in Table 3. The practical implication is that more water was well distributed on the land at riser height 2 m while risers 4.0 m, 3.0 m and 1.5 m were not. Thus, riser (2 m) generates less runoff. file:///C:/Users/user/Downloads/azojete143/www.azojete.com.ng Kuti, et al. Effect of different riser heights on sprinkler irrigation performance under constant operating pressure AZOJETE, 15(1):124-132. ISSN 1596-2490; e-ISSN 2545-5818, www.azojete.com.ng 130 Table 3: Determination of the Volume of water Caught in the Cans under constant operating pressure Date Time Riser Height (m) Total Volume of Water in the Cans (ml) Evaporation and Drift Losses (%) Wind Direction Mean Application Rate (mm hr-1) 29/72016 5:06 PM 1.5 799 5.22 NW 8.56 30/7/2106 9:32 AM 2 632 5.7 NE 7.76 30/7/2106 10:27 AM 3 745 8.21 NE 7.56 30/7/2106 11:23 AM 4 874 10.2 SE 6.76 3.2 Effect of Riser Height on Water Caught in the Catch Cans under Constant Operating Pressure The analysis of variance for the water determined in the catch cans was shown in Table 1. The factor riser 1.5m, 2m, 3m and 4m do bring significant information to the model since the computed p-value is less than alpha (0.05). The risers 2 and 3 were significantly different because their means do not have any letter in common (Table 1), and concluded that the riser height has the different mean value of water caught in the catch cans. Besides, the Tukey pairwise comparisons show that riser heights 1.5 m, 2 m, 3 m and 4 m have different water trapped in the catch cans because the Means that do not share a letter are significantly different. Tukey simultaneous tests for differences of means for water caught were shown in Table 3. The difference in level between riser height 4 m and 2 m have a higher effect on the water found in the catch-can be followed by the riser 2m and 1.5m, 4m and 3m and 3m and 2m since their p- values were 0.000, 0.001, 0.016 and 0.046 respectively. Thus, the risers have a different effect on the volume of water caught. Table 1: Analysis of Variance Source DF Adj SS Adj MS F-value P-value Riser 3 863.9 287.97 11.28 0.000 Error 140 3575.4 25.54 Total 143 4439.3 Table 2: Tukey Pairwise Comparison Risers Mean Grouping 4 24.28 A 1.5 22.19 AB 3 20.694 B 2 17.556 C Means that do not share a letter are significantly different http://www.azojete.com.ng Arid Zone Journal of Engineering, Technology and Environment, March, 2019; Vol. 15(1):124-132. ISSN 1596-2490; e-ISSN 2545-5818; www.azojete.com.ng Corresponding author’s e-mail address: gbengailori@unilag.edu.ng 131 Table 3: Tukey Simultaneous Tests for Differences of Means (volume of water) Difference in Level Difference of Means SE of Difference 95% CI T-Value Adjusted P- value 2.0 - 1.5 -4.64 1.19 (-7.74, -1.54) -3.89 0.001 3.0 - 1.5 -1.50 1.19 (-4.60, 1.60) -1.26 0.590 4.0 - 1.5 2.08 1.19 (-1.02, 5.18) 1.75 0.303 3.0 - 2.0 3.14 1.19 ( 0.04, 6.24) 2.64 0.046 4.0 - 2.0 6.72 1.19 ( 3.62, 9.82) 5.64 0.000 4.0 – 3.0 3.58 1.19 ( 0.48, 6.68) 3.01 0.016 3.3 Determination of Coefficient of Uniformity (CU) and Distribution Uniformity (DU) under different Riser Heights at Constant Operating Pressure (1.6 bars) The uniformity coefficient and the distribution coefficient of the sprinkler irrigation system were shown in Table 4. At riser height 1.5 m, the Coefficient of Uniformity (CU) and distribution uniformity (DU) were 70% and 61% respectively. The CU and DU values at 2 m riser height were 89% and 85% respectively. At riser 3.0 m, CU and DU values were 85% and 78% respectively. The CU and DU at 4 m riser height were 72% and 70 respectively. This study found out that the riser height 2.0 m had the highest CU (89%) and DU (85%) values. Also, the riser height of 1.5 m had the lowest CU (70%) and DU (61%) values. CU for riser height 4.0 m and 1.5 m were classified unsatisfactory while the CU for riser height 2 m and 3 m were rated good (Little et al., 1993). Also, the DU for 2 m and 3 m were rated excellent and fair while the DU for 1.5 m and 4 m were rated poor (Bloomer, 2006). The study revealed that riser heights 2 m and 3 m have optimum CU and DU. Table 4: Coefficient of Uniformity and Distribution of Uniformity of different Risers Riser Height (m) CU (%) DU (%) 1.5 70 61 2 89 85 3 85 78 4 72 70 4 Conclusion The effect of different riser heights on the performance of sprinkler irrigation at constant operating pressure was assessed to provide water for the cultivation of high crops and reduce water wastage. The study revealed that as the riser height increases the mean application rate decreases. The riser heights 2 and 3 m were significantly different because their means do not have any letter in common, and concluded that some of the riser height have the different mean value of water found in the catch-can. This study reveals that as the wind direction changes the volume of water trapped in catch cans also increases which in turn cause weak CU. The study concluded that riser heights 2m and 3m have the highest CU and DU at 1.6 bars and these riser heights can provide water for taller crop and reduce water losses on the field. file:///C:/Users/user/Downloads/azojete143/www.azojete.com.ng Kuti, et al. Effect of different riser heights on sprinkler irrigation performance under constant operating pressure AZOJETE, 15(1):124-132. ISSN 1596-2490; e-ISSN 2545-5818, www.azojete.com.ng 132 References Bavi, A., Kashkuli, HA., Boroomand, S., Naseri, A. and Albaji, M. 2009. Evaporation losses from sprinkler irrigation systems under various operating conditions. Journal of Applied Sciences, 9(3), 597-600. Bishaw, D., and Olumana, M. 2015. Evaluating the Effect of Operating Pressure and Riser Height on Irrigation Water Application under Different Wind Conditions in Ethiopia. Asia Pacific Journal of Energy and Environment, 2(1): 41-48. Bloomer DJ. 2006. Irrigation Evaluation Code of Practice. Hastings, New Zealand: Bloomer Associates Ltd. Evans, RG., and Sadler, EJ. 2008. Methods and technologies to improve the efficiency of water use. Water Resources Research, 44, 1-15. Fanadzo, M., Chiduza, C., Mnkeni, PNS., Van der Stoep, I., and Stevens, J. 2010. Crop production management practices as a cause for low water productivity at Zanyokwe Irrigation Scheme. Water South African, 36 (1): 27-36. Galadima, IM. 2014. An analysis of growth trends in Gidan Kwano and its impact on agriculture. Project submitted to Federal University of Technology Minna, pp 9. Little, GE., DJ. Hills, BR. and Hanson. 1993. Uniformity in Pressurized Irrigation Systems Depends on Design, Installation. California Agriculture, 47: 18-21. Magagula, C. 2013. Technical efficiency of sprinkler irrigation in Swaziland: a case study of the Lusip Phase 1 in Lubovane area. M. Sc. Thesis submitted to the University of Zimbabwe, pp. 1-15. Molle, B., Tomas, S., Hendawi, M. and Granier, J. 2012. Evaporation and wind drift losses during sprinkler irrigation influenced by droplet size distribution: irrigation and Drainage, 61(2), pp.240- 250. Nakayama, FS., and Bucks, DA. 2012. Trickle irrigation for crop production: design, operation and management. Tokyo: Elsevier Science, pp 10. Onwualu, AP., Akubuo, CO., and Ahaneku, IE. 2006. Fundamentals of engineering for agriculture. Lagos: Immaculate Ltd., pp. 259-262. Okasha, EM. and Pibars, SK. 2016. Investigation of riser height and operating pressure on sprinkler irrigation performance under different wind condition. International Journal of ChemTech Research, 9(7): 292-299. Smajstrla, AG., and Zazueta, FS. 1994. Evaporation loss during sprinkler irrigation. University of Florida Cooperative Extension Service, Institute of Food and Agriculture Sciences, EDIS, pp. 1-8. Yahaya, MK. 2002. Development and challenges of Bakolori irrigation project in Sokoto State, Nigeria. Nordic Journal of African Studies, 11 (3): 411-430. Yazar, A., Howell, TA., Dusek, DA., and Copeland, KS. 1999. Evaluation of crop water stress index for LEPA irrigated corn. Irrigation Science, 18(4): 171-180 Kara, T., Ekmekci, E. and Apan, M. 2008. Determining the uniformity coefficient and water distribution characteristics of some sprinklers. Pakistan Journal of Biological Sciences, 11(2), 214- 219. http://www.azojete.com.ng