id	author	title	date	pages	extension	mime	words	sentence	flesch	summary	cache	txt
brj-24310	Bóna, Dušan; Chovanec, Daniel; Jaďuďová , Jana; Makovická Osvaldová, Linda; Marková, Iveta	Analysis of Spontaneous Ignition Temperature and Flash Point for Predicting Fire Risk in Biomass Fuel Pellet Storage	2025	14	.pdf	application/pdf	5310	276	48	The activation energy was higher for the Norway spruce pellet (65.4 KJ.mol-1) for spontaneous ignition temperature and for the experimental pellet (42.1 KJ.mol-1) for flash point temperature. DOI: 10.15376/biores.20.2.3676-3688 Keywords: Spontaneous ignition temperature; Flash point temperature; Setchin Furnace test; Wood pellets Contact information: a: Department of Fire Engineering, University of Žilina, Univerzitna 8215/1, 01026 Zilina; b: Department of Crisis Management, Faculty of Security Engineering, University of Žilina, Univerzitna 8215/1, 01026 Zilina; *Corresponding author: jana.jadudova@uniza.sk INTRODUCTION Biomass-based fuels, such as wood pellets, have emerged as a sustainable and renewable energy source in recent decades, offering an alternative to fossil fuels for mitigating climate change.	cache/brj-24310.pdf	txt/brj-24310.txt