Performances of a Biomass Powered Micro-Chp System in a 

Demonstrative Environment 

Maria Antonietta Costagliola, Gabriele Di Blasio, Roberto Ianniello, Gaia 

Martoriello*, Maria Vittoria Prati, Giovanna Ruoppolo, Massimo Urciuolo 

CNR – Istituto di Scienze e Tecnologie per l’Energia e la Mobilità Sostenibili, Dipartimento di Ingegneria, Viale Marconi, 4, 

80125 Naples,  

g.martoriello@im.cnr.it  

A viable solution for residual biomass exploitation to reduce the cost related to biomass disposal and 

simultaneously create profit by electrical and thermal energy use is combined heat and power generation over 

the micro-scale of power (m-CHP) based on biomass gasification. The exploitation and improvement of these 

systems were the main objectives of the Italian project “PROMETEO – Production of electrical, thermal and 

cooling energy with m-CHP fueled by residual biomass”, funded by the local Ministry of Economic Development 

(MISE). The present work shows an extended experimental activity based on a 20kW micro-cogeneration 

system as powered by two types of residual lignocellulosic biomasses briquettes in a demonstrative environment 

site identified in a waste management and storage plant in the Municipality of Mugnano, Naples, in the south of 

Italy. The m-CHP plant is made of a gasifier, a syngas cleaning circuit and a spark ignition (SI) internal 

combustion engine (ICE) connected to an electric-generator. The electrical output was meant to power the plant 

machines for the operations of waste storage. For both biomasses, tests were conducted for the complete 

characterization of the system in low and medium load and in different spark ignition timing to assess the system 

sensitivity. The m-CHP performance was investigated with a complete characterization of the syngas and tar 

compositions, main pollutant emissions and internal combustion engine analyses, aimed at the evaluation of 

the energetic and environmental efficiencies. An analysis of the air quality near the site by evaluating CO, O3, 

NO2, C6H6 and PM10 concentration was also carried out. The ultimate purpose of the present work is the 

demonstration of the advantages of the employment of biomass-powered cogeneration systems in the 

Mediterranean regions.  

Introduction 

Modern bioenergy is currently the largest renewable energy source, with a share in final energy consumption 

five times greater than wind and solar PV combined (Frankl, 2017). Because of its broad availability, woody 

biomass has gotten a lot of interest, especially if gasification is involved, even though itis only been used for 

energy production in a few places so far. Biomass derived syngas is a low-energy and adaptable fuel gas that 

can be used in spark ignition internal combustion engines (ICEs) (Costa et al., 2020) that were designed to run 

on gasoline or diesel fuels to decrease or eliminate the need for petroleum-based fuels. Lund’s paper (Lund, 

2014) shows an analysis of smart energy systems synergies, highlighting the possible infrastructures for 

biomass to energy systems and the use of gasification in the cogeneration technology. The exploitation of 

electrical generation employing a syngas-powered engine in combined heat and power assets can be used in 

both the developed and developing countries to reduce greenhouse gas emissions and to provide electricity in 

rural locations where biomass is normally available. The main goal of this work is to show the benefits of using 

biomass-powered air cogeneration systems in Mediterranean regions as part of biomass-to-energy chains that 

can be set up in rural areas and to serve municipalities that need to dispose of green waste from pruning and 

maintenance operations.  

301



 
 

Experimental layout 

A micro-cogeneration system based on biomass gasification, whose description and main specification are 

reported in ref. (Costa et al., 2020), was characterized in a demonstrative environment aiming at concretely 

verifying the sustainability of whole biomass-to-energy chains and understanding its viability as a green energy 

system in a waste management and storage plant. The micro-cogeneration plant is made of a gasifier, a syngas 

cleaning circuit and a spark ignition ICE connected to an electric generator. Gasifycation agents is air with an 

equivalence ratio – the ratio between gasifyication agents-to-biomass to their stoichiometric mixture – of 0.3. 

Compared to steam gasification (Stark et al., 2019), air gasification is a cheaper but less efficient alternative, 

leading to a syngas with a high percentage of nitrogen (>45%) that reduce the overall LHV. Figure 1a shows 

the experimental setup. The properties of biomasses were determined by means of proximate analysis (TGA 

701 LECO thermogravimetric analyzer), ultimate analysis (CHN 628 LECO analyzer; SC 144 DR LECO 

analyzer). All the analyses were performed in triplicate at least. The analysis of syngas composition is made by 

online measurement (O2, CO, CO2, CH4 and H2) by Vario Luxx analyser and an off-line sampling in Tedlar bags 

the stream which is subsequently analyzed through a by a micro gas chromatograph (micro-GC) (Agilent 3000A) 

providing the concentration of light hydrocarbons (CxHy). The syngas sampling (Figure 1b) was performed with 

a probe heated to 463K, positioned on the syngas supply duct to the engine. Before the analysis, the syngas 

was forced to pass through a quartz fiber filter, to restrain any solid particles and then to a double condensation 

stage: (the first happens at room temperature, and the second stage at about 273 K) to condense the tar and to 

perform its quantification weighting the condensation train before and after the sampling. The experimental 

setup used for the analysis of the tar concentration is shown in Figure 1d. Exhaust gases composition is 

analyzed through a direct measurement with Sensors Semtech analyzer. The analysis system is equipped with 

a NDIR infrared absorption analyzer to measure CO, CO2, a Non-Dispersive Ultra-Violet (NDUV) detector for 

NO/NO2 measurement and an electrochemical sensor for O2. A volumetric flow meter (0-4.96 m3/min) was also 

installed (Figure 1c), operating using the Pitot principle. The exhaust gas temperature was measured near the 

exhaust gas flow measurement section. An NOx/O2 sensor (Continental UniNOx) was also mounted.  

 
a) 

   
b) c) d) 

Figure 1: Experimental setup(a), probe for syngas sampling (b), duct for exhaust volumetric flow meter (c) and 

quartz fiber filter (d) 

In order to measure the ICE indicated pressure cycle, the engine was equipped with properly defined and/or 

designed sensors, specialized for non-traditional gaseous fuels: 

302



 
 

1. a spark plug relative pressure sensor, type AVL ZI45-F5D, for the high-frequency measurement of the 

indicated pressure cycle, placed in the spark-plug seat, based on the piezo-quartz principle, very precise 

and robust; 

2. a low-pressure absolute sensor, type AVL LP12DA-05, for the high-frequency measurement of the 

dynamic pressure in the intake duct, necessary for referencing the indicated pressure cycle, based on the 

piezo-resistive principle. It was placed in a proper realized threatened hole in the intake runner. 

A multiparametric station (ETL-One) with Unitec SENS-IT technology for continuous gas and dust monitoring 

was hired from the Orion company for air quality assessment analysis of the micro-cogeneration system installed 

in the waste management and storage plant of Mugnano, Napoli. The experimental campaign was performed 

in two days, during which the prevailing wind is was a wind that blew from the SOUTH-WEST. Therefore, the 

monitoring station was located in a NORTH, NORTH-EAST position related to the location of the plant in order 

to be downwind of the polluting emissions. 

Results 

Table 1 reports the proximate and ultimate analysis of the used feedstocks: sawdust (Biomass 1) and straw 

(Biomass 2) while Table 2 shows the average syngas compositions and the tar concentration. As 

aforementioned, the nitrogen percentage higher than 45% is due to air used as the gasifier agent.The ultimate 

analysis of the two feedstocks is similar to each other, except for the greater nitrogen concentration observed 

in sawdust. A higher presence of ash and moisture in the Biomass 2, which is slightly over the systems’ limits 

has been also evidenced. Syngas compositions do not differ much; lower heating values and stoichiometric 

ratios are comparable even if tar concentration obtained using the Biomass 2 is three times higher than that 

obtained for Biomass 1. Despite that, the cleaning circuit ran well, as no plant stop is noticed during both days.   

Table 1: Biomass proximate and ultimate analyses 

 Biomass 1 Biomass 2 

Proximate Analysis (%) 

Moisture 7.2 23.9 
Ash 2.5 5.1 

Fixed Carbon 18.0 14.1 
Volatile matter 72.3 57.0 

Ultimate Analysis (%) ash and moisture free 

C 48.1 46.7 
N 4.5 0.2 
O 41.4 46.7 
H 6.0 6.3 

Table 3: Engine operating condition test matrix 

Load kWe 
Spark 

Advance 
(°CAD) 

λ (-) 

L 4-6 -20 1.03 

M 14-15 
-15, -20 
-25, -30 

1.03 

 

Table 2: Syngas compositions and lower heating 

values 

 Biomass 1 Biomass 2 

O2 (%vol) 1.64 1.26 
CO2 (%vol) 11.48 12.02 
CO (%vol) 18.77 18.35 
H2S (ppm) 9.65 12.82 
CH4 (%vol) 2.05 1.82 
H2 (%vol) 16.74 16.94 
N2 (%vol) 49.32 49.61 

LHV (MJ/kg) 4.21 4.13 
αst 1.45 1.42 

Tar concentration 
(g/m3) 

2.13 8.57 

 

 

 

 

 

 

Table 3 reports the engine operating condition test matrix adopted for both biomasses. It should be noted that 

the table shows a range of load, low or medium, due to the variability of load required by plant machines for the 

operations of waste storage during the execution of the experimental tests. Figure 2 shows the exhaust mass 

flow (a) and temperature (b) of both feedstocks. No difference between sawdust and straw arises for exhaust 

mass flow ratio, which appears to not be influenced by the initial feedstock. Biomass 2 presents a slightly higher 

exhaust temperature than Biomass 1 for medium load and a spark advance of -20 ° CAD. However, these 

values remain in the range of effective exhaust temperature for the reduction of CO emissions, as they indicate 

temperature higher than 250°C and lower than 650°C in the after-treatment system. An extreme exhaust 

temperature, indeed, could destroy the catalytic converter. The measured emission species are summarized in 

Figure 3. The emissions have been recalculated on a wet basis as required by the Italian legislation Dlgs. 

11/15/2017, no. 183 – Fixed engine in cogenerative asset (D.lgs. n. 183). In the M load condition and -15 °CAD 

spark advance, a high variability is found in the determination of CO due to a sudden and fast load variation, so 

the data were recalculated only in the times with a fairly constant load condition.

303



  

a) 

  

b) 

Figure 2: Exhaust mass flow rate (a), temperature (b) for both processed feedstocks. 

  

a) 

  

b) 

Figure 3: CO (a) and NOx (b) for both processed feedstocks. 

CO and NOx concentrations are not particularly variable with the ignition advance. For Biomass 1 CO and NOX 

emissions are below 70 mg/m3 in all tested conditions, below the limits set by Dlgs. no. 183. Even in the most 

critical condition for CO, which occurred at M load and advance -15 ° with a sudden load variation, the CO 

remains below the limits. It should be noted that on the Biomass 2 test day there was a concurrence with a small 

fire in a close area (south) which influenced the air quality assessment (in terms of CO) and, therefore, also the 

air sucked by the system itself. Furthermore, there were problems on the lambda control which in some 

304



 
 

conditions dropped to 0.9. In the conducted analyses, it is not always possible to filter the data to eliminate these 

effects. This is highlighted in the Biomass 2 CO emission that presents high variability and, in some cases, also 

overtakes Italian limits. NOx  for Biomass 2 was always below limits. 

Engine sensibility analysis  

The following analysis show the engine response varying biomasses, loads and spark timing. Figure 4 shows 

the trend of the Mean Indicated Pressure (IMEP), covariance of the IMEP (IMEPCOV), the maximum pressure 

(Pmax), the combustion phasing (MFB50), and the combustion duration (MFB10-90) calculated from the 

measured pressure curve in the combustion chamber. MFB50 is defined as the crank angle in which 50% of the 

fuel is burned. MFB10-90 is the crank angle interval between 10% and 90% of the burned fuel mass. The IMEP 

values fluctuate in the range 1-1.5 bar with a maximum pressure value of about 10 bar, and due to the electrical 

real-time request from the municipal site. As regards the IMEPCOV, as well as the MFB50 and the MFB10-90, 

an important variability is highlighted. They vary due to the non-constant syngas composition. Indeed, the 

covariance, which is indicative of the combustion stability, oscillates between 8-12% for Biomass 1 and 10-13% 

for Biomass 2, much higher values compared to automotive or natural gases applications, whose maximum 

values set about 5% (Heywood, 2018). This instability is partially transferred to MBF10-90 and MBF50 values, 

which highlights a more delayed combustion phase in low loads.  

  

Low load Medium load 

Figure 3: IMEP, IMEPCOV, Pmax, MFB50 and MFB10-90 for both biomasses (low and medium load). 

For the medium load condition, the thermodynamic efficiency trends, and the combustion main parameters at 

the different start of spark are shown in Figure 4 (on the right). There are no radical differences between the two 

fuels; the thermodynamic efficiencies are in line with those present in the literature (Caputo et al., 2019; Costa 

et al., 2020). Thermodynamic efficiency is sensitive to the ignition advance and has an optimal value for both 

biomasses for values around 20 crank angle degrees aTDC. This demonstrates the optimal calibration obtained 

by both numerical models and experimental measurement. The IMEP values for Biomass 2 are less sensitive 

to the variation of the spark advance. Indeed, a rather flat trend is observed. Combustion stability, on the other 

hand, is markedly sensitive to early ignitions, with values almost in line with the previous case (sawdust), except 

for the most anticipated case. Regarding the maximum peak pressure, values and trends between the two fuels 

are aligned. MFB50 is in line with the low load cases. Syngas deriving from Biomass 1 presents a higher burn 

duration than Biomass 1 for all spark advances. 

Air assessment analysis  

The air quality assessment analysis is carried out for both test days and ETL-One is leaved in its position 

overnight, with the system shut off, to have the full-scale measurement to understand the effect of the installation 

305



 
 

of the micro-cogeneration system in the area. The hourly average concentrations of carbon monoxide (CO), 

nitrogen dioxide (NO2), benzene (C6H6), ozone (O3) and dust (PM10) are obtained for both test days.The 

following Table 4 shows the hourly average measured concentrations measured in g/m3. A conclusion that can 

be drawn in relation to the environmental impact of the CMD ECO20x mCHP system, it seems not to influence 

the air quality.  

Table 4: Air quality assessment during the two test days and full-scale measurement. 

- CO (g/m3) NO2 (g/m3) C6H6 (g/m3) O3 (g/m3) PM10 (g/m3) 

Biomass 1 test day 350 44.2 0.50 97.6 15.30 

Biomass 2 test day 1150 67.0 0.60 26.4 1,5 

Full-scale 300÷1700 37÷100 0.3÷2,9 6÷95 0.6÷22 
Limit (D.lgs. n. 155) 

(Sampling time) 
10000 

(8h Moving average) 
200 
(1h) 

5 
(1year) 

- 
50 

(24h) 

Conclusions 

The experimental analysis of a micro-combined heat and power generation unit powered by biomass is 

discussed to estimate the effects of different feedstocks in terms of overall performances and reliable operation 

and the possibility of employment in a waste management and storage system in the locality of Mugnano, 

Naples, Italy. The strict link between feedstock composition and ICE performance in terms of efficiency, tar 

quantity and emissions are found to underline the possibility of using biomass-based microcogeneration plant 

in a real demonstrative environment. The here analysed system is shown to be a versatile plant as different 

biomasses can be processed. Through the proposed analysis, the following considerations could be drawn: 

1. Biomass composition influences tar percentages in syngas sampling; 

2. CO and NOx emissions are below limits when ICE syngas-air mixture is lean. 

3. Engine performance and operative conditions are reliable regardless of the initial feedstocks. 

4. The micro-cogeneration system does not have an impact on the air quality. 

The described methodology is universal and can show the potentiality of micro cogeneration system based on 

biomass gasification. 

Acknowledgments 

Authors gratefully acknowledge the financial support of project PROMETEO - Production of electrical, thermal 

and cooling energy with m-CHP fueled by residual biomass - by the Italian Ministry of Economic Development 

(MISE). A particular greeting goes to the Costruzioni Motori Diesel S.p.A. and eng. Domenico Cirillo, for their 

supports to the experimental work by using their micro-cogeneration system, the CMD ECO20x.  

References 

Bates, R. and Dölle, K. (2017) ‘Syngas Use in Internal Combustion Engines - A Review’, Advances in Research, 

10(1), pp. 1–8. doi:10.9734/AIR/2017/32896. 

Caputo, C. et al. (2019) Multi-Level Modeling of Real Syngas Combustion in a Spark Ignition Engine and 

Experimental Validation. SAE Technical Paper 2019-24–0012. Warrendale, PA: SAE International. 

doi:10.4271/2019-24-0012. 

Costa, M. et al. (2020) ‘Multi-objective optimization of a syngas powered reciprocating engine equipping a 

combined heat and power unit’, Applied Energy, 275, p. 115418. doi:10.1016/j.apenergy.2020.115418. 

Italian Legislation, Dlgs 13 agosto 2010, n. 155 - Normattiva [Online], https://www.normattiva.it/uri-

res/N2Ls?urn:nir:stato:decreto.legislativo:2010;155  , 2010 (accessed 1.9.22) - Italy. 

Italian Legislation, Dlgs 15 novembre 2017, n. 183 - [Online] https://www.normattiva.it/uri-

res/N2Ls?urn:nir:stato:decreto.legislativo:2017-11-15;183 , 2017 (accessed 11.12.21) - Italy. 

Frankl, P., (2017). IEA Technology Roadmap: The need to scale up sustainable bioenergy. 

Heywood, J.B. (2018) Internal Combustion Engine Fundamentals. McGraw-Hill Education. Available at: 

https://www.accessengineeringlibrary.com/content/book/9781260116106 (Accessed: 20 December 2021). 

Lund, H., (2014).”Renewable energy systems: a smart energy systems approach to the choice and modeling of 

100% renewable solutions”. Chemical Engineering Transaction. doi: https://doi.org/10.3303/CET1439001  

2014. 

Stark, M., et al. (2019) "Design Parameters of Steam Accumulators for the Utilization in Industrial Solid Biomass-

Fuelled CHP Plants." CHEMICAL ENGINEERING, 76. doi: https://doi.org/10.3303/CET1976137 

306


	101urciuolo.pdf
	Performances of a Biomass Powered Micro-Chp System in a Demonstrative Environment