Format And Type Fonts
CHEMICAL ENGINEERING TRANSACTIONS
VOL. 45, 2015
A publication of
The Italian Association
of Chemical Engineering
www.aidic.it/cet
Guest Editors: Petar Sabev Varbanov, Jiří Jaromír Klemeš, Sharifah Rafidah Wan Alwi, Jun Yow Yong, Xia Liu
Copyright © 2015, AIDIC Servizi S.r.l.,
ISBN 978-88-95608-36-5; ISSN 2283-9216 DOI: 10.3303/CET1545054
Please cite this article as: Barna B., Varbanov P.S., Klemeš J.J., Yong J.Y., 2015, Object-oriented model and file format for
heat exchanger network computations, Chemical Engineering Transactions, 45, 319-324 DOI:10.3303/CET1545054
319
Object-Oriented Model and File Format for Heat Exchanger
Network Computations
Balázs Barna, Petar S. Varbanov*, Jiří J. Klemeš, Jun Yow Yong
Centre for Process Integration and intensification – CPI
2
, Faculty of IT, University of Pannonia, Egyetem u.10,
Veszprém, Hungary
varbanov@cpi.uni-pannon.hu
There have been software packages available for designing, retrofitting and optimising Heat Exchanger
Networks (HENs). From those only a handful is available without any charge. Most of them are offered
commercially. For professional consultants and large industry such solutions are adequate. However, for
researchers they are usually too complicated, not too flexible and expensive. Converting data manually
and unifying them in MS-Excel has been practiced to remedy this, but it is time-consuming and leaves a
room for errors and semantic mismatch. A step towards a solution of this problem can be an open data
exchange file format, which correctly reflects the entities in the HEN domain.
The goal of this contribution has been to develop an object oriented model and a prototype file storage
format primarily for HEN related tasks. This file format should enable collaboration on simulation,
optimisation and synthesis of HENs. It is based on mapping the relevant process units and stream types to
object-oriented concepts. An XML-based file format has been derived from the class design to store the
topology and relevant data. To test the object model and the file format, a prototype software application
has been created.
1. Introduction
Efficient software tools are essential for research, design and industrial implementation. For process
optimisation as well as Process Integration, there have been several attempts to introduce data exchange
formats based on XML. Some examples are e.g. electronic document management systems in university
context (Costoiu et al., 2012) and the use of ontologies in supply chain optimisation (Silvente et al., 2013).
The benefit of enabling data exchange with preservation of the data structure and model semantics, that
the community accepts, can open the door for creating new applications focusing on different parts of the
same domain, and at the same time use a common language, for achieving good mutual understanding,
saving project cost and increasing scientific and industrial productivity.
A number of software packages for design of Heat Exchanger Networks (HENs) are available. Only
several tools are available free of charge and those well-developed are offered commercially. For
consultants and large industry such solutions are adequate. For researchers they are usually too
complicated, needing a substantial training and too expensive. Data exchange between researchers
needed for an efficient collaboration is usually not easy as the software tools are rarely compatible. Using
MS-Excel as a data exchange platform, for example, is flexible. However, it is time-consuming and leaves
a room for errors and misunderstanding.
Freeware tools have been developed for educational or research purposes. An example comes from the
Louisiana State University (Knopf, 2015), available since 2001 – displaying and saving HEN topology.
However it has been developed for Windows 95, storing the data in plain text files, without an open
specification. Other, more sophisticated, software tools are available. For instance, Heat Integration tool ―i-
Heat‖ developed by Process Integration Ltd (i-HEAT, 2015) provides capability to import from or export to
process simulators, but inter-operability with other tools of similar purpose or a data exchange format
description are limited as the tool is mainly for the in-house use. A commercial tool – SuperTarget®, has
been developed originally by Linnhoff March and from the acquisition by KBC (SuperTarget, 2015). It has
320
similar features; however being developed as commercial tool for a long time. SuperTarget® software tool
can also exchange data with process simulators.
The available commercial and freeware tools for HEN synthesis, optimisation and integration do offer
some import-export functionality. However none of them provides an open specification of the data storage
formats, which can be established as an essential enabler for the use of those tools and improved
efficiency in project teams. The goal of this contribution is to develop an object oriented model and an
efficient file storage format for HENs integration and synthesis. This has to adequately describe the
information structure and functionalities of heat exchangers, the topology and all relevant HEN properties.
They should support the Heat Integration, simulation, synthesis, design of HENs including retrofit. A key
goal is to make the model and the related file format open, enabling the exchange of information between
research and business partners while preserving of data quality and semantics.
2. Process Integration and Heat Integration Summary
Process Integration serves the industry in solving the challenges posed initially by the oil crises in the
second half of 20
th
century. This is a family of methodologies for combining parts of processes or whole
processes together, aiming at reducing consumption of resources or harmful emissions into the
environment. It started (Linnhoff and Flower, 1978) mainly as Heat Integration (HI). It has been extensively
used in the processing and power generating industry over the last 40 y (Klemeš and Kravanja, 2013).
HI has several definitions, almost always referring to the thermal combination of process streams in
continuous or batch processes for achieving heat recovery. The definition of PI, as adopted by the
International Energy Agency (Gundersen, 2000) reads as: ―Systematic and General Methods for Designing
Integrated Production Systems ranging from Individual Processes to Total Sites, with special emphasis on
the Efficient Use of Energy and reducing Environmental Effects‖.
3. The Problem Domain: Heat Exchanger Networks (HENs)
A HI analysis, has a number of steps, including Data Extraction, Pinch Analysis, HEN optimisation, design
or retrofit actions, and eventually further iterations until stable results and customer satisfaction are
reached. A complete reference on this can be found in (Klemeš, 2013), while Klemeš et al. (2014) provide
a textbook university curricula. The parts of the methodology, essential for the current work, include
starting from a process flowsheet, performing data extraction, tabulating the process stream data (Table
1). After that the relevant HEN representation – usually as a Grid Diagram, see Figure 1, is constructed.
Figure 1: Grid Diagram for the a HEN (adopted from Klemeš et al., 2014)
Table 1: An example dataset for HEN construction
No. Type TS [°C] TT [°C] CP [kW/°C]
1 Cold 20 180 20
2 Hot 250 40 15
3 Cold 140 230 30
4 Hot 200 80 25
Key concepts in HI are Process Streams and Branches, Utility Streams (hot and cold utilities), Heat
Exchanger, Heater, Cooler, Heat Exchanger Network, Temperature Difference, Minimum Allowed
Temperature Difference (ΔTmin), Splitters and Mixers – to support stream splitting (Klemeš et al., 2013).
These and all related concepts have been analysed, proposing consistent conceptual and class models.
PINCH
40 ºC
80 ºC
20 ºC
QHmin = 750 kW QCmin = 1,000 kW
1,750 kW
52.5 ºC
650 kW
106.7 ºC
1,000 kW
2
800 kW
1,250 kW
203 ºC
Tx = 181.7 ºC
3
250 ºC
200 ºC
180 ºC
230 ºC140 ºC
CP
15
25
20
30
150 ºC
150 ºC
140 ºC
3
4
[kW/°C]
H
205 ºC
700 kW 750 kW
1
C
321
4. The Concept and Class Models
First the underlying concepts related to Heat Exchanger Networks are identified, followed by Object-
Oriented Analysis and data model identification (Roebuck, 2011), following the steps of finding the objects,
organising them, describing their interactions, identifying their behaviour and their sub-items.
4.1 Main Concepts and Relations
The overall concepts mapping is given in Figure 2. Heat Exchanger Network is the container class. It has
two members: Id and Name. The name is a free text field which is used to provide an easy to remember
key for the system. The description field is optional. Each HEN object has a set of ―ProcessingUnit‖ objects
– modelled as a collection based on the Processing Unit class.
Figure 2: HEN Concepts Model
―ProcessingUnit‖ is the abstract base class of everything that can modify the state of a stream – including
heat exchangers, mixers and splitters. Each ―ProcessingUnit‖ is identified by its
―ProcessingUnitReference‖. A possible alternative would be to extend this identifier with a ―Name‖ property
of type ―string‖ for easier comprehension. Figure 3 highlights the complete ―ProcessingUnit‖ hierarchy.
Process Streams are modelled as a collection of ―AbstractProcessStream‖ objects – normal Process
Streams and utilities. The ―Branch‖ class is derived from ―Stream‖ to enable handling stream splits, where
―Branch‖ objects belong to the streams.
Regular Process Streams and utilities have semantic and functional differences. Although nominally each
of them has flowrate or heat capacity flowrate (CP) and starting and target temperatures, they are treated
differently – all Process Stream properties are usually specified and fixed for the Heat Integration analysis,
while the CPs or loads for the utility streams are allowed to vary within certain bounds, providing degrees
of freedom in the HEN optimisation. This semantic and functional set of requirements is reflected by firstly
defining the ―Stream‖ and ―AbstractProcessStream‖ classes deriving from the latter the ―ProcessStream‖
and ―UtilityProcessStream‖ classes.
The HEN class (―HeatExchangerNetwork‖) holds ―ProcessingUnit‖ instances directly and ―Stream‖ only
holds references to those ―ProcessingUnit‖ entities using ―ProcessingUnitReference‖ links. They are
reflecting the streams passing through the processing unit, which enables specifying the HEN topology. It
is sufficient to declare an entity and refer to it avoiding repetition and conflicts. Such data organisation
makes the resulting XML, less cluttered and less error prone.
―HeatExchanger‖ represents recovery heat exchangers, with two ―ProcessStream‖(s). For utility heat
exchangers, ―Heater‖ and ―Cooler‖ classes are derived from ―HeatExchanger‖, imposing the constraint that
322
one of the input streams is an ―UtilityProcessStream‖ and the other a ―ProcessStream‖. They have the
same attributes as ―HeatExchanger‖, but allow implementation flexibility. ―Splitter‖ and ―Mixer‖ classes
work in combination with the ―Branch‖ class. A ―Splitter‖ divides a stream into two ―Branches‖. Two
―Branches‖ can be joined in a ―Mixer‖. Each ―Stream‖ instance (including ―AbstractProcessStream‖) can
store a list of ―Branches‖, allowing a ―Branch‖ to have further nested ―Branch‖ instances.
Figure 3: “ProcessingUnits” Hierarchy
Figure 4: The simple HEN from the Example (after Klemeš et al., 2014)
4.2 Topology Representation
―Stream‖ is an abstract class containing the attributes of a stream. The key attribute, storing the topology
for the stream, is the ―ProcessSteps‖ list. It contains the references (―ProcessingUnitReference‖) of the
units through which the stream passes. Assume a stream instance ―Stream[Id=0]‖, having
―ProcessingUnitReference[Id=3]‖, ―ProcessingUnitReference[Id=1]‖. This means that the stream enters
first Heat Exchanger 3 and then Heat Exchanger 1.
323
4.3 The resulting XML format
Following the described class system, the ―HeatExchangerNetwork‖ class is instantiated in the root
element in the xml document. Taking the simple HEN in Figure 4, Figure 5 shows an XML representation.
The first section of the document, after the HEN description, is an inventory represented by the
―ProcessingUnits‖ class. Every unit that is part of the HEN model is a member of the collection. This is
followed by the ―ProcessStreams‖ section with embedded stream splits/merges and heat exchanger links.
Figure 5: The XML representation of the HEN from Figure 4
5. Prototype Software for Validation of the Data Model
A prototype software application has been developed to test the described class model and XML format
definition. The application enables users to create and edit HEN descriptions, saving them into an XML
file, loading saved work from XML, Grid Diagram view to display topology, and HEN simulation. Figure 6
shows a partial screenshot from a test of the split-merge functionality designed in the XML format.
Figure 6: Screenshot of the HEN Editor interface
xml
version = "1.0"
encoding = "utf - 8" ?>
0
TestSystem
Sample network: Two streams, three heat exchangers.
TargetTemperature = "25"
TargetTemperature = "180"
324
6. Conclusions and suggestions for future work
This contribution has presented a class model and a suggestion for an XML format for storing HEN related
data and enabling efficient data exchange. This is a prototyping effort responding to the challenge of
providing distributed research teams with means of exchanging model information with the model
semantics accompanying the data in appropriate context. The presented model and XML format are the
first step towards fully addressing this challenge. The correctness of the model has been validated using a
simple prototype software tool where all key functionalities regarding the data have been verified –
including editing, saving, loading and simulating a HEN. It is important to stress that the format allows
handling stream splits.
The future work should include evolution of the class model and XML format to more fully integrate stream
splits, allowing direct implementation of more than two branches as well as measurement units. Further,
the possibility to combine the developed ideas with the CAPE-OPEN initiative (Co-LaN, 2015) should be
investigated, potentially providing interfaces and compliance with the CAPE-OPEN compliant software
tools on the market.
Acknowledgement
The authors gratefully acknowledge the financial support from Hungarian Project TÁMOP-4.2.2.B-
15/1/KONV-2015-0004 "A Pannon Egyetem tudományos műhelyeinek támogatása".
References
Co-LaN, 2015. The CAPE-OPEN Laboratories Network accessed 16.06.2015.
Costoiu M., Plesu V., Isopescu R., Soriga S.G., Alesincu S.H., Arsene I., 2012. Electronic document
management information system for universities, Chemical Engineering Transactions, 29, 1639-1644.
Gundersen T., 2000. A Process Integration Primer — Implementing agreement on process integration.
International Energy Agency, SINTEF Energy Research, Trondheim, Norway.
i-HEAT, 2015. Innovative Software for the Design and Optimisation of Heat Recovery Systems
accessed 05.05.2015.
Klemeš J.J. (Ed.), 2013. Handbook of Process Integration (PI). Minimisation of Energy and Water Use,
Waste and Emissions. Woodhead Publishing/Elsevier, Cambridge, United Kingdom, ISBN: 978-0-
85709-593-0
Klemeš, J. J., Kravanja, Z., 2013, Forty Years of Heat Integration: Pinch Analysis (PA) and Mathematical
Programming (MP), Current Opinion in Chemical Engineering, 2 (4) 461-474
Klemeš, J.J., Varbanov, P.S., Kravanja Z., 2013. Recent Developments in Process Integration, Chemical
Engineering Research and Design, 91 (10) 2037–2053
Klemeš J.J., Varbanov P.S., Wan Alwi, S.R., Abdul Manan, Z, 2014, Process Integration and
Intensification: Saving Energy, Water and Resources, De Gruyter, Berlin, Germany
Knopf F.C., 2015. The Heat Exchanger Network , accessed
10.06.2015.
Linnhoff B., Flower J.R., 1978. Synthesis of heat exchanger networks: I. Systematic generation of energy
optimal networks. AIChE Journal, 24(4), 633–642.
Roebuck K., 2011 Object-oriented Analysis and Design (OOAD): High-impact Strategies - What You Need
to Know: Definitions, Adoptions, Impact, Benefits, Maturity, Vendors. Emereo Pty Ltd Books, Brisbane,
Australia, ISBN-1743044917.
Silvente J., Crexells G., Zamarripa M., Muñoz E., Espuña A., 2013. Use of Ontological Structures for
Integrated Supply Chain Management. Chemical Engineering Transactions, 32, 1165-1170.
Supertarget, 2015. Improve heat integration while reducing operating costs and optimizing capital
investment accessed 10.06.2015