id	author	title	date	pages	extension	mime	words	sentence	flesch	summary	cache	txt
cet-13064		cet-13064		6	.pdf	application/pdf	2205	101	48	Table 1: Resulting Capacitances of the four granules and their calculated EASAs Single granule Small packed bed Medium packed bed Big packed bed Capacitance (mF) 13.5 10.5 10.1 9.8 EASA (cm2) 67 52 50 49 Figure 2: Cyclic Voltammetries of the four anodes conducted at 100 mV/s. -3200 -2400 -1600 -800 0 800 1600 2400 -0,35 -0,15 Table 2: Bioelectrochemical performance of the cathodic biofilm during the two operating periods Single granule Small packed bed Medium packed bed Big packed bed Average current (µA) 1152 ± 88 752 ± 66 698 ± 54 427 ± 47 Current peak (µA) 1824 1195 1129 756 Average current density (µA/cm2) 17.2 ± 1.3 14.5 ± 1.1 14 ± 1 8.7 ± 0.9 Current Peak density (µA/cm2) 27.2 23 22.6 15.4 Figures 4-A-B-C-D show how the packed bed negatively influenced the current generation.	cache/cet-13064.pdf	txt/cet-13064.txt