cet-13162		cet-13162		6	.pdf	application/pdf	3437	106	37	Increasing the dosing time enhances the process safety because it permits the shift of the RB towards higher setpoint temperatures; this means that it is possible to work at higher temperatures avoiding the loss of temperature control. Finally, another important aspect emerged from Figure 3: temperature controller parameters must not be changed without looking at their corresponding runaway boundaries; this means that they shouldn’t be considered as mere operating parameters which can be set directly online without further investigation.	cache/cet-13162.pdf	txt/cet-13162.txt