Microsoft Word - ETASR_V12_N5_pp9276-9281


Engineering, Technology & Applied Science Research Vol. 12, No. 5, 2022, 9276-9281 9276 
 

www.etasr.com Hussein & Abdul Rasoul: Steel Fiber Addition in Eco-Friendly Zero-Cement Concrete: Proportions and … 

 

Steel Fiber Addition in Eco-Friendly Zero-Cement 

Concrete: Proportions and Properties 
 

Ali N. Hussein 

Department of Civil Engineering 

University of Kerbala 

Kerbala Iraq 

ali.naser@s.uokerbala.edu.iq 

Zainab M. R. Abdul Rasoul 

Department of Civil Engineering 

University of Kerbala 

Kerbala Iraq 

zainabm@uokerbala.edu.iq

Aymen J. Alsaad 

Department of Civil Engineering 

University of Kerbala 

Kerbala Iraq 

aymen.alsaad@uokerbala.edu.iq  
 

Received: 4 July 2022 | Revised: 20 July 2022 | Accepted: 23 July 2022 

 

Abstract-The main objective of this paper is to study the 

behavior of eco-friendly zero-cement concrete, its proportions, 

and its properties. The experimental program involves casting 

and testing many specimens divided into three main groups 

according to the percentage of added steel fibers in order to 

investigate the effect of steel fibers on the density, compressive 

strength, modulus of elasticity, and splitting tensile strength of 

concrete. The experimental outcomes indicated that the 

percentage of steel fibers has a small impact on the dry density: 

adding 0.5% and 1% of steel fibers increased the dry density by 

about 0.9% and 1.6% respectively. The percentage of steel fibers 

has an important impact on the compressive strength: after 28 

days, steel fibers increased the compressive strength by about 

4.9% and 12.8% for added steel fiber percentages of 0.5% and 

1%. Also, the results indicated that steel fiber had an important 

impact on the splitting tensile strength in concrete after 28 days 

of curing: adding 0.5% and 1% steel fibers increased the splitting 

tensile strength by about 11.8%and 23.2% respectively. Finally, 

adding steel fibers has an impact on the modulus of elasticity: 

after 28 days, adding 0.5% and 1% steel fibers improved the 

modulus of elasticity approximately by 1.7% and 5%. 

Keywords-eco-friendly concrete; Pozzolime concrete; steel 

fibers; mechanical properties  

I. INTRODUCTION  

Global attention in eco-friendly and sustainable building 
materials has increased over the last decades and new 
constructional adhesives to replace conventional cement are 
researched. Researchers are being urged to investigate 
alternatives, such as the reinstitution of lime Pozzolanic 
systems. Lime might be considered an ecologically friendly 
binder due to its low energy needs, limited CO2 emissions 
during production, and carbonation-induced CO2 uptake 
through setting [1]. Lime natural Pozzolans are ancient 
building materials that were utilized in the process of building 

using masonry. The use of lime natural Pozzolanic materials 
had ceased to exist due to the development of inorganic 
bindings due to their sluggish setting and hardening. After the 
discovery of Portland cement in the nineteenth century, the use 
of natural pozzolan-lime binding materials decreased 
considerably. The environmental repercussions of the Portland 
cement production process have increased interest in lime-
natural Pozzolan cement during the last 50 years [2]. Kadum 
[3], created Pozzolime, a unique, sustainable binder composed 
of hydrated-lime, silica fumes, and fly ashes. Many studies 
have shown that the addition of fibers, especially steel fibers, to 
concrete can reduce the requirement for conventional 
reinforcement in certain circumstances. Steel fibers increase the 
post-cracking tension response and cracking control qualities of 
reinforced concrete [4]. Utilizing deformed fibers, like those 
that are hooked, corrugated, or twisted, can further boost the 
mechanical strength of composite materials. Reportedly, 
deformed steel fibers give 3 to 7 times the fiber-matrix binding 
strength of straight fibers. Several factors, including fiber 
shape, fiber length, and curing conditions, influence the degree 
to which mechanical properties are enhanced [5]. Fibers are 
typically added to Fiber-Reinforced Cementitious Composites 
(FRCCs) in order to restrict the volumetric ratio of the mix to 
3% in order to address mixing and casting issues such as fiber 
floating and balling. 

Pozzolans are natural or man-made materials that are not 
cementitious on their own but, because they are made of 
aluminosilicates, they create hydraulic cement when mixed 
with lime hydrates. Authors in [6] investigated the viability of 
employing Pozzolans derived from natural sources in Algeria. 
This Pozzolanic material is seldom used in concrete, so its 
features have not been thoroughly examined. To learn more 
about the effectiveness of Pozzolan concrete, 6 concrete mixes 
were tested: one with Portland cement (as a reference), and 5 

Corresponding author: Ali N. Hussein



Engineering, Technology & Applied Science Research Vol. 12, No. 5, 2022, 9276-9281 9277 
 

www.etasr.com Hussein & Abdul Rasoul: Steel Fiber Addition in Eco-Friendly Zero-Cement Concrete: Proportions and … 

 

with 10, 20, 30, 40, and 50% Pozzolan substitution of cement. 
To make lightweight aggregate concrete, shattered Pozzolan 
was used as the Lightweight Aggregates (LA), and fine sand 
was added to all mixes (LAC). Workability and density of fresh 
concrete mixes were evaluated. The compressive strength, 
splitting tensile strength, and flexural strength of hardened 
concrete samples were measured after 3, 7, 28, 90, and 365 
days. All the concrete mixes had a constant cementitious 
material concentration of 400kg/m

3
. The findings of this 

experiment indicated that the inclusion of Pozzolan at 20% of 
the weight of cement results in the greatest gain in strength 
among the evaluated mixes. 

The experimental results of [7-12] showed that the addition 
of fly ash particles had little effect on the mechanical properties 
of normal concrete, while steel fibers had the greatest effect. 
The highest increase was reported in compressive and flexural 
strength. 

II. EXPERIMENTAL WORK 

A. Materials  

1) Hydrated Lime 

In Pozzolime concrete compositions, hydrated lime is 
utilized. The main component of hydrated lime is calcium 
hydroxide (Ca(OH)2). The utilized hydrated lime was 
manufactured at a lime factory in Karbala and conforms to the 
Iraqi standard IQS No. 807 /2004 [13]. Table I displays the 
chemical analyses, chemical composition, and physical 
properties. 

TABLE I.  CHEMICAL AND PHYSICAL TEST VALUES OF HYDRATED 
LIME* 

C
h
e
m

ic
a
l 

a
n

a
ly

si
s 

Components Results % Limits IQS NO. 807 

CaO + MgO 73.1 Min. 65% 

SiO2 2.28  

Al2O3 1.08  

Fe2O3 0.23  

MgO 0.46 5% Max. 

Fe2O3+Al2O3+ SiO2 3.60 5% Max. 

SO3 0.2  

Loss on ignition 22.8  

Ca(OH)2 92.49 85% Min 

CaO % activity 70.12  

P
h

y
si

c
a
l 

te
st

 

CO2 % 2.27 5% Max. 

Residue on 90µ m 2.2 10% Max. 

Slaking time 24 Min 

Fineness m
2
/kg 361  

* The tests were carried out in Karbala plant for cement and lime 

 

2) Cement  

This study utilized Portland cement, since it is readily 
accessible on the market. The used cement was utilized in the 
production of earlier concrete mixtures. The chemical and 
physical characteristics agree to the limitations of Iraqi 
standard No.5/1984 type V [14] (see Tables II and III). 

3) Fine Aggregates  

Local fine sand complying to zone two of the IQS No. 45 
was utilized as FA [15]. According to the findings, the FA 
satisfies the grading requirements of this standard.  

TABLE II.  CHEMICAL COMPOSITION AND MAIN COMPOUNDS OF 
SULFATE-RESISTING PORTLAND CEMENT* 

Oxides composition Content % Limits of Iraqi standard No.5/1984 

CaO 62.15 --- 

SiO2 19.88 --- 

Al2O3 3.5 --- 

Fe2O3 4.7 --- 

MgO 3.23 < 5.00 

SO3 1.84 < 2.50 

Na2O 0.26  

K2O 0.51  

L.O.I. 1.25 < 4.00 

Insoluble residue 0.80 < 1.5 

Lime Saturation Factor 0.928 0.66-1.02 

Main compounds (Bogue's equations) 

C3S 54.51 --- 

C2S 18.77 --- 

C3A 1.51 < 3.50 

C4AF 14.14 --- 

* Chemical analysis wase carried out in the Karbala Laboratory 

TABLE III.  PHYSICAL PROPERTIES OF CEMENT 

Physical properties 
Test 

results 

Limits of Iraqi 

standard No.5/1984 

Surface area (Blaine) m
2
/kg 282 ≥ 250 

Setting time (Vicat) 

Initial setting, 

hrs: min 
3:51 ≥ 45 min 

Final setting, 

hrs: min 
6:20 ≤ 10 hrs 

Compressive 

strength, MPa 

3 days 23.7 ≥ 15.00 

7 days 27.9 ≥ 23.00 

Soundness (autoclave) % 0.13 ≤ 0.8 

 

4) Coarse Aggregates 

All mixtures contained local river gravel broken to a 
maximum size of 12.50mm as Coarse Aggregates (CA). The 
grading of CA corresponds to the Iraqi standard IQS No.45/ 
1984 [15]. The CA properties were determined at the Karbala 
construction laboratory. 

TABLE IV.  CHEMICAL ANALYSIS OF SILICA FUME* 

No. Components 
Silica 

fume % 

ASTM C1240 

limitations 

1 

CaO 1.22  

SiO2 91.05 ≥ 85 

Al2O3 0.018  

Fe2O3 0.012  

MgO 0.01  

SO3 0.225  

Na2O 0.205  

K2O 0.155  

Loss on ignition 2.975 ≤ 6 

Moisture content 0.68 ≤ 3  

2 

Activity index with Portland 

cement at 7 days 
132.4 ≥ 105  

Percentage retained on 45µm 

(No. 325) sieve, max, % 
7 ≤ 10  

Surface area (Blaine) m
2
/kg 20000 ≥ 15000 

*The tests was carrying by the manufacturer 

 



Engineering, Technology & Applied Science Research Vol. 12, No. 5, 2022, 9276-9281 9278 
 

www.etasr.com Hussein & Abdul Rasoul: Steel Fiber Addition in Eco-Friendly Zero-Cement Concrete: Proportions and … 

 

5) Silica Fume 

Silica fume is a by-product of the production of silicon 
composites in electrical arched furnaces and may be utilized as 
a cementitious additive to improve the performance of concrete 
[16]. Densified micro-silica fume from Mega-Add MC (D) 
type was utilized in this study. Its Pozzolanic activity index is 
132.4% after 7 days. Table IV displays the chemical and 
particular surface of the utilized silica fume, which conforms to 
ASTM C1240 [17]. 

6) High-Range Water Reducing Admixture 

As shown in Table V, this additive belongs to the 3rd 
generation of superplasticizers. The admixture satisfies the 
standards of ASTM C 494 type G [18]. 

TABLE V.  TECHNICAL DESCRIPTION OF THE ADDITIVE* 

Chemical Base Polycarboxylic ether based 

Appearance/color Amber homogenous liquid 

Density 1.082 - 1.142 kg/liter, at 20°C 

Chlorine content% < 0.1 

Alkaline content% < 3 

Recommended dosage (0.5 - 1.5) of binder weight % 

*Manufacturer data sheet 

7) Water  

Tap water was utilized for mixing and curing. The molten 
salts comprise fewer than one thousand parts per million. 
Distilled water was utilized for concrete mixing and curing. 

8) Steel Fibers 

Micro-steel fibers of the RC 59/13 BN type, with low 
carbon content, and with both straight ends were utilized. The 
fibers have a length of 13mm, diameter of 0.22mm, aspect ratio 
of 59, tensile strength of 2850MPa, and density of 7.85g/cm

3
. 

B. Mix Proportion  

Authors in [3] have invented a sustainable binder known as 
Pozzolime. This binder consists of hydrated-lime, silica-fume; 
and does not include Portland cement. Table VI displays the 
proportions chosen for two Pozzolime mixtures, mix1 and 
mix2, based on the work of [3]. Using a small quantity of 
cement in mix2 hastened setting time. Firstly, 6 cubes were 
tested for compressive strength (fcu) for each mix, and the 
results show that the value of fcu for mix2 was 15.4 and 
18.3MPa for age of 7 and 14 days respectively, while the fcu for 
mix1 was 16.6 and 18.6MPa respectively. So, mix1 was chosen 
for the rest of the experimental work. 

TABLE VI.  POZZOLIME CONCRETE MIX PROPORTIONS AND PROPERTIES 

Mixing 

Materials   

Hydrate lime 

(kg/m
3
) 

Cement 

(kg/m
3
) 

Silica fume 

(kg/m
3
) 

FA 

(kg/m
3
) 

CA 

(kg/m
3
) 

W/B ratio 

by wt. 

HRWR 

by wt. of cement (%) 

Slump 

mm 

Compressive strength, 

28 days (MP)a 

Mix1 225 - 225 625 945 0.45 2.9 100 24.3 

Mix2 310 25* 110 600 940 0.5 2.5 115 23.8 

* for accelerated setting time 

 

C. Casting and Curing of Specimens 

All steel molds (cylinders and cubes) were cleaned and 
their inside was completely lubricated to prevent the concrete 
from adhering to the molds after setting. The concrete was 
poured in two layers before being compacted with a tamping 
rod or vibrating machine to exclude as much air as possible 
[19-21]. The samples' top surfaces were then troweled, and in 
order to avoid the loss of mixing water and moisture from the 
top surface and plastic shrinkage breaking, they were protected 
with polythene sheets for 24 hours.  

 

 
Fig. 1.  The tested specimens. 

The samples were then demolded and completely 
submerged in tap water until testing time. The curing schedule 

for pervious concrete was 7 and 28 days of water curing. Figure 
1 shows the tested specimens. Control specimens were also 
used in this research, so the total samples used were 9 cubes 
(10×10×10cm) for the density test, 27 cubes (10×10×10cm) for 
the compressive strength test, 27 cylinders (30×15cm) for the 
splitting tensile strength test, and 27 cylinders (30×15cm) for 
the modulus of elasticity test. 

III. RESULTS AND DISCUSSION 

A. Dry Density 

Concrete's dry density following ASTM C138 [22] was 
determined using a cylinder mold. The specimens were 
evaluated after 28 days of water curing. The density of 
hardened concrete was determined using the subsequent 
procedures: 

γdry = Wdry / Vol    (1) 

where γdry is the dry density (kg/m
3
), Wdry the oven-dry mass 

(kg), and Vol the volume of the specimens (m
3
). 

B. Compressive Strength 

Compressive strength testing was determined in accordance 
with the BS EN 12390.0 [23] using a standard hydraulic digit 
ELE machine of 2000kN capacity at a loading rate of about 
0.30MPa/s. At each test, the average value of 3 tested cubes 
was determined. The tests on Pozzolime concrete were 
conducted after 7 and 28 days of curing. 



Engineering, Technology & Applied Science Research Vol. 12, No. 5, 2022, 9276-9281 9279 
 

www.etasr.com Hussein & Abdul Rasoul: Steel Fiber Addition in Eco-Friendly Zero-Cement Concrete: Proportions and … 

 

C. Splitting Tensile Strength (fct) 

Splitting tensile strength tests were based on ASTM C 
496/C496M-(2011) [24]. A hydraulic digital testing ELE 
machine of 2000kN capacity was used to load the cylinders 
constantly up to failure at a loading rate of 2.2kN/sec. The 
mean splitting tensile strength was calculated using the average 
of 3 cylinders. 

D. Modulus of Elasticity (Ec) 

The modulus of elasticity of concrete (Ec) was tested using 
3 concrete cylinders in accordance with ASTM C-469-(2002), 
[25]. Ec is calculated from the stress-strain diagram using a 
compress meter gauge with a length of 20cm and an accuracy 
of 0.001mm. The load was applied at a steady rate up to 40% 
of the maximum load. 

All laboratory tests values for concrete mix1 are shown in 
Tables VII and VIII. 

TABLE VII.  TEST RESULTS OF CONCRETE MIX1 

Property 
Steel fibers 

(%) 

Density 

(kg/m
3
) 

Increase 

in density (%) 

Fresh density 0 2283 Ref. 

Fresh density 0.5 2288 0.2 

Fresh density 1 2292 0.4 

Dry density 0 2250 Ref. 

Dry density 0.5 2270 0.9 

Dry density 1 2285 1.6 

Oven density 0 2150 Ref. 

Oven density 0.5 2200 2.3 

Oven density 1 2225 3.5 

 

Table VII indicates that the steel fiber percentage has a 
small effect on the fresh density: the increase of the percentage 
increased the fresh density by about 0.2, and 0.4% for added 
steel fiber percentage of 0.5 and 1% with respect to the 
reference specimens. Also, the steel fiber percentage has a 
small impact on dry density. Steel fibers increased dry density 
by about 0.9 and 1.6% for 0.5 and 1% added steel fiber 
percentage. Steel fibers had a higher impact on the oven 
density: steel fibers increased the oven density by about 2.3 and 
3.5% for 0.5 and 1% added steel fiber percentage. Figure 2 
shows the impact of steel fiber percentage on concrete density. 

 

 

Fig. 2.  The impact of steel fiber percentage on concrete density. 

Table VII indicates that the steel fiber percentage has an 
important impact on compressive strength: steel fibers 

increased compressive strength by about 2.4 and 16.3% when 
0.5 and 1% steel fibers were added at curing age of 7 days. 
This is comparable to [7], which shows that the percentage of 
2% steel fibers increased the compressive strength by about 
10.8%. Adding steel fibers increased the compressive strength 
by about 4.1, and 37.6% for 0.5 and 1% steel fiber addition at 
14 days. At 28 days, the respective increase percentages were 
4.9 and 12.8%. Figure 3 shows the effect of steel fiber 
percentage on concrete compressive strength at various ages. 

TABLE VIII.  RESULTS OF LABORATORY TESTS FOR CONCRETE MIX1 

Property Steel fiber (%) Result (MPa) Increase (%) 

fcu, 7 days 

0 16.6 Ref. 

0.5 17 2.4 

1 19.3 16.3 

fcu, 14 days 

0 18.6 Ref. 

0.5 22.7 4.1 

1 25.6 37.6 

fcu, 14 days 

0 24.3 Ref. 

0.5 25.5 4.9 

1 27.4 12.8 

fct, 7 days 0 2.11 Ref. 

fct, 14 days 0.5 2.36 11.8 

fct, 28 days 1 2.6 23.2 

Ec, 7 days 0 23800 Ref. 

Ec, 14 days 0.5 24200 1.7 

Ec, 28 days 1 25000  5 

 

 
Fig. 3.  The impact of steel fiber percentage on concrete compressive 
strength at various ages. 

Also, Table VIII indicates that the steel fiber percentage has 
a significant impact on splitting tensile strength (fct) for 28 days 
curing age. Steel fiber 0.5 and 1% addition increased fct by 
about 11.8 and 23.2%. Finally, the addition of steel fibers has 
an impact on Ec after 28 days of curing. Steel fiber 0.5 and 1% 
addition increased Ec by about 1.7 and 5%. 

IV. PARAMETRIC STUDY 

Figures 4, 5, 6, and 7 indicate the impact of steel fiber 
percentage on density, compressive strength, splitting tensile 
strength, and modulus of elasticity respectively. The relation 
between the steel fibers percentage and splitting tensile strength 
was linear, while the relation between steel fiber percentage 
and compressive strength and modulus of elasticity was 
nonlinear for specimens cured for 28 days. 

 



Engineering, Technology & Applied Science Research Vol. 12, No. 5, 2022, 9276-9281 9280 
 

www.etasr.com Hussein & Abdul Rasoul: Steel Fiber Addition in Eco-Friendly Zero-Cement Concrete: Proportions and … 

 

 

Fig. 4.  Impact of steel fiber percentage on density. 

 

Fig. 5.  Impact of steel fiber percentage on compressive strength. 

 

Fig. 6.  Impact of steel fiber percentage on splitting tensile strength after 
28 days of curing. 

 

Fig. 7.  Effect of steel fiber percentage on the modulus of elasticity after 28 
days of curing. 

V. CONCLUSIONS 

• Steel fiber percentage had a minor influence on fresh 
density. Adding 0.50 and 1.0% steel fiber to the reference 
specimen enhanced the fresh density by 0.2% and 0.4% 
respectively.  

• Steel fiber percentage had a marginal impact on dry density. 
Adding 0.5 and 1.0% steel fibers to the reference specimen 
raised the dry density by 0.9% and 1.6% respectively.  

• Steel fiber percentage had a larger influence on oven 
density. Adding 0.5 and 1% steel fibers raised oven density 
by 2.3% and 3.5% respectively. 

• Steel fiber percentage had an important impact on 
compressive strength. Adding 0.50 and 1.0% steel fibers 
increased compressive strength by 2.4% and 16.3% 
respectively, after 7 days of curing. Adding 0.50 and 1.0% 
steel fibers increased compressive strength by 4.1% and 
37.6% at 14 days and 4.9% and 12.8% at 28 days. 

• Steel fiber percentage had a substantial influence on 
splitting tensile strength at 28 days. Adding 0.50 and 1.0% 
steel fibers enhanced splitting tensile strength by 11.8% and 
23.2% respectively. 

• Steel fiber percentage affects the modulus of elasticity at 28 
days. Adding 0.50 and 1.0% steel fibers increased the 
modulus of elasticity by 1.7% and 5% respectively.. 

VI. RECOMMENDATIONS FOR FUTURE WORK 

• Studying eco-friendly zero-cement concrete proportions 
and properties under the effects of high-temperature. 

• Studying slurry Infiltrated Fiber Concrete (SIFCON) 
proportions and properties under the effects of high-
temperature. 

REFERENCES 

[1] A. J. Alsaad, T. S. Al-Attar, and B. S. Al-Shathr, "Utilization of Mineral 
Sequestration for CO2 Capturing in Car Parks and Tunnels," 
Engineering and Technology Journal, vol. 38, no. 5, pp. 728–737, May 
2020, https://doi.org/10.30684/etj.v38i5A.594. 

[2] A. Moropoulou, A. Cakmak, K. C. Labropoulos, R. Van Grieken, and K. 
Torfs, "Accelerated microstructural evolution of a calcium-silicate-
hydrate (C-S-H) phase in pozzolanic pastes using fine siliceous sources: 
Comparison with historic pozzolanic mortars," Cement and Concrete 
Research, vol. 34, no. 1, pp. 1–6, Jan. 2004, https://doi.org/10.1016/ 
S0008-8846(03)00187-X. 

[3] N. Kadum, T. al-Attar, and Z. Al-Azzawi, "Evaluation of pozzolime 
mixtures as a sustainable binder to replace portland cement in structural 
concrete," MATEC Web of Conferences, vol. 120, 2017, Art. no. 02009, 
https://doi.org/10.1051/matecconf/201712002009. 

[4] S. P. Shah and B. V. Rangan, "Fiber Reinforced Concrete Properties," 
Journal Proceedings, vol. 68, no. 2, pp. 126–137, Feb. 1971, 
https://doi.org/10.14359/11299. 

[5] G. K. Mohammed, K. F. Sarsam, and I. N. Gorgis, "Flexural 
Performance of Reinforced Concrete Built-up Beams with SIFCON," 
Engineering and Technology Journal, vol. 38, no. 5, pp. 669–680, May 
2020, https://doi.org/10.30684/etj.v38i5A.501. 

[6] M. Mouli and H. Khelafi, "Performance characteristics of lightweight 
aggregate concrete containing natural pozzolan," Building and 
Environment, vol. 43, no. 1, pp. 31–36, Jan. 2008, https://doi.org/ 
10.1016/j.buildenv.2006.11.038. 



Engineering, Technology & Applied Science Research Vol. 12, No. 5, 2022, 9276-9281 9281 
 

www.etasr.com Hussein & Abdul Rasoul: Steel Fiber Addition in Eco-Friendly Zero-Cement Concrete: Proportions and … 

 

[7] N. A. Farhan, M. N. Sheikh, and M. N. S. Hadi, "Engineering Properties 
of Ambient Cured Alkali-Activated Fly Ash–Slag Concrete Reinforced 
with Different Types of Steel Fiber," Journal of Materials in Civil 
Engineering, vol. 30, no. 7, Jul. 2018, Art. no. 04018142, https://doi.org/ 
10.1061/(ASCE)MT.1943-5533.0002333. 

[8] Q. Wang, Y. Yi, G. Ma, and H. Luo, "Hybrid effects of steel fibers, 
basalt fibers and calcium sulfate on mechanical performance of PVA-
ECC containing high-volume fly ash," Cement and Concrete 
Composites, vol. 97, pp. 357–368, Mar. 2019, https://doi.org/10.1016/ 
j.cemconcomp.2019.01.009. 

[9] M. A. Faris et al., "Comparison of Hook and Straight Steel Fibers 
Addition on Malaysian Fly Ash-Based Geopolymer Concrete on the 
Slump, Density, Water Absorption and Mechanical Properties," 
Materials (Basel, Switzerland), vol. 14, no. 5, Mar. 2021, Art. no. 1310, 
https://doi.org/10.3390/ma14051310. 

[10] B. Ali, S. S. Raza, R. Kurda, and R. Alyousef, "Synergistic effects of fly 
ash and hooked steel fibers on strength and durability properties of high 
strength recycled aggregate concrete," Resources, Conservation and 
Recycling, vol. 168, May 2021, Art. no. 105444, https://doi.org/10.1016/ 
j.resconrec.2021.105444. 

[11] M. Shariq, S. Pal, R. Chaubey, and A. Masood, "An experimental and 
analytical study into the strength of hooked-end steel fiber reinforced 
HVFA concrete," Advances in concrete construction, vol. 13, no. 1, pp. 
35–43, 2022, https://doi.org/10.12989/acc.2022.13.1.035. 

[12] M. H. Kumar, I. Saikrishnamacharyulu, N. R. Mohanta, A. Ashutosh, P. 
Mishra, and S. Samantaray, "Mechanical behaviour of high strength 
concrete modified with triple blend of fly ash, silica fume and steel 
fibers," Materials Today: Proceedings, Apr. 2022, https://doi.org/10. 
1016/j.matpr.2022.03.528. 

[13] Iraqi specification no 807: Lime Used in Buildings. 2004. 

[14] Iraqi specification Standard no 5: Portland Cement. 1984. 

[15] Iraqi Specification Standard no 45: Natural Aggregate Resources Used 
in Buildings and Concrete. 1984. 

[16] P. K. Mehta and P. J. M. Monteiro, Concrete: Microstructure, 
Properties, and Materials, 4th ed. New York, NY, USA: McGraw Hill, 
2013. 

[17] ASTM C1240-20 : Standard Specification for Silica Fume Used in 
Cementitious Mixtures. ASTM International, 2020. 

[18] ASTM C494/C494M-13: Standard Specification for Chemical 
Admixtures for Concrete. ASTM International, 2013. 

[19] A. M. Al-Hilali, A. F. Izzet, and N. Oukaili, "Static Shear Strength of a 
Non-Prismatic Beam with Transverse Openings," Engineering, 
Technology & Applied Science Research, vol. 12, no. 2, pp. 8349–8353, 
Apr. 2022, https://doi.org/10.48084/etasr.4789. 

[20] B. F. Abdulkareem, A. F. Izzet, and N. Oukaili, "Post-Fire Behavior of 
Non-Prismatic Beams with Multiple Rectangular Openings 
Monotonically Loaded," Engineering, Technology & Applied Science 
Research, vol. 11, no. 6, pp. 7763–7769, Dec. 2021, https://doi.org/ 
10.48084/etasr.4488. 

[21] H. M. Hekmet and A. F. Izzet, "Performance of Segmental Post-
Τensioned Concrete Beams Exposed to High Fire Temperature," 
Engineering, Technology & Applied Science Research, vol. 9, no. 4, pp. 
4440–4447, Aug. 2019, https://doi.org/10.48084/etasr.2864. 

[22] ASTM C138/C138M-17a: Standard Test Method for Density (Unit 
Weight), Yield, and Air Content (Gravimetric) of Concrete. ASTM 
International, 2017. 

[23] BS EN 12390-3:2019 - TC: Testing hardened concrete - Compressive 
strength of test specimens. BSI, 2019. 

[24] ASTM C496/C496M-17 : Standard Test Method for Splitting Tensile 
Strength of Cylindrical Concrete Specimens. ASTM International, 2017. 

[25] ASTM C469/C469M-14: Standard Test Method for Static Modulus of 
Elasticity and Poisson’s Ratio of Concrete in Compression. ASTM 
International, 2014.