id	author	title	date	pages	extension	mime	words	sentence	flesch	summary	cache	txt
eurjchem-1358	El-Kerdawy, Mohamed Mahmoud; El-Bagary, Ramzia Ismail; Elkady, Ehab Farouk; Othman, Ahmed Adel	Development and validation of a stability-indicating RP-LC method for the simultaneous determination of otilonium bromide and its expected degradation product in bulk drug and pharmaceutical preparation	2016	5	.pdf	application/pdf	4096	193	65	The parameters of these tests are column efficiency (number of theoretical plates), tailing of chromatographic peak, repeatability as %R.S.D of peak area for six injections and reproducibility of retention as %R.S.D of retention time of a solution of a 50 µg/mL of OB (100% concentration) and 25 µg/mL of its degradant. Changing the flow rate of mobile phase by ±0.1, acetonitrile ratio by ±2%, Varying the pH of the mobile phase by ±0.1 didn’t have significant effect on chromatographic resolution by the proposed LC method for OB and its degradation product, indicating good robustness of the proposed method as shown in Tables 7‐9.	cache/eurjchem-1358.pdf	txt/eurjchem-1358.txt