id	sid	tid	token	lemma	pos
fuelectenerg-3675	1	1	facta	facta	PROPN
fuelectenerg-3675	1	2	universitatis	universitatis	PROPN
fuelectenerg-3675	1	3	series	series	NOUN
fuelectenerg-3675	1	4	:	:	PUNCT
fuelectenerg-3675	1	5	electronics	electronic	NOUN
fuelectenerg-3675	1	6	and	and	CCONJ
fuelectenerg-3675	1	7	energetics	energetics	NOUN
fuelectenerg-3675	1	8	vol	vol	NOUN
fuelectenerg-3675	1	9	.	.	PUNCT
fuelectenerg-3675	2	1	31	31	NUM
fuelectenerg-3675	2	2	,	,	PUNCT
fuelectenerg-3675	2	3	no	no	DET
fuelectenerg-3675	2	4	4	4	NUM
fuelectenerg-3675	2	5	,	,	PUNCT
fuelectenerg-3675	2	6	december	december	PROPN
fuelectenerg-3675	2	7	2018	2018	NUM
fuelectenerg-3675	2	8	,	,	PUNCT
fuelectenerg-3675	2	9	pp	pp	ADV
fuelectenerg-3675	2	10	.	.	PUNCT
fuelectenerg-3675	3	1	613	613	NUM
fuelectenerg-3675	3	2	-	-	SYM
fuelectenerg-3675	3	3	626	626	NUM
fuelectenerg-3675	3	4	https://doi.org/10.2298/fuee1804613k	https://doi.org/10.2298/fuee1804613k	PROPN
fuelectenerg-3675	3	5	calibration	calibration	NOUN
fuelectenerg-3675	3	6	of	of	ADP
fuelectenerg-3675	3	7	ac	ac	PROPN
fuelectenerg-3675	3	8	induction	induction	NOUN
fuelectenerg-3675	3	9	magnetometer	magnetometer	NOUN
fuelectenerg-3675	3	10			PROPN
fuelectenerg-3675	3	11	branko	branko	PROPN
fuelectenerg-3675	3	12	koprivica	koprivica	PROPN
fuelectenerg-3675	3	13	,	,	PUNCT
fuelectenerg-3675	3	14	marko	marko	PROPN
fuelectenerg-3675	3	15	šućurović	šućurović	PROPN
fuelectenerg-3675	3	16	,	,	PUNCT
fuelectenerg-3675	3	17	alenka	alenka	NOUN
fuelectenerg-3675	3	18	milovanović	milovanović	PROPN
fuelectenerg-3675	3	19	university	university	PROPN
fuelectenerg-3675	3	20	of	of	ADP
fuelectenerg-3675	3	21	kragujevac	kragujevac	PROPN
fuelectenerg-3675	3	22	,	,	PUNCT
fuelectenerg-3675	3	23	faculty	faculty	NOUN
fuelectenerg-3675	3	24	of	of	ADP
fuelectenerg-3675	3	25	technical	technical	PROPN
fuelectenerg-3675	3	26	sciences	sciences	PROPN
fuelectenerg-3675	3	27	ĉaĉak	ĉaĉak	PROPN
fuelectenerg-3675	3	28	,	,	PUNCT
fuelectenerg-3675	3	29	ĉaĉak	ĉaĉak	PROPN
fuelectenerg-3675	3	30	,	,	PUNCT
fuelectenerg-3675	3	31	serbia	serbia	PROPN
fuelectenerg-3675	3	32	abstract	abstract	ADJ
fuelectenerg-3675	3	33	.	.	PUNCT
fuelectenerg-3675	4	1	the	the	DET
fuelectenerg-3675	4	2	aim	aim	NOUN
fuelectenerg-3675	4	3	of	of	ADP
fuelectenerg-3675	4	4	this	this	DET
fuelectenerg-3675	4	5	paper	paper	NOUN
fuelectenerg-3675	4	6	is	be	AUX
fuelectenerg-3675	4	7	to	to	PART
fuelectenerg-3675	4	8	describe	describe	VERB
fuelectenerg-3675	4	9	a	a	DET
fuelectenerg-3675	4	10	procedure	procedure	NOUN
fuelectenerg-3675	4	11	and	and	CCONJ
fuelectenerg-3675	4	12	experimental	experimental	ADJ
fuelectenerg-3675	4	13	setup	setup	NOUN
fuelectenerg-3675	4	14	for	for	ADP
fuelectenerg-3675	4	15	calibration	calibration	NOUN
fuelectenerg-3675	4	16	of	of	ADP
fuelectenerg-3675	4	17	ac	ac	PROPN
fuelectenerg-3675	4	18	induction	induction	PROPN
fuelectenerg-3675	4	19	magnetometer	magnetometer	NOUN
fuelectenerg-3675	4	20	.	.	PUNCT
fuelectenerg-3675	5	1	the	the	DET
fuelectenerg-3675	5	2	paper	paper	NOUN
fuelectenerg-3675	5	3	presents	present	VERB
fuelectenerg-3675	5	4	an	an	DET
fuelectenerg-3675	5	5	overview	overview	NOUN
fuelectenerg-3675	5	6	of	of	ADP
fuelectenerg-3675	5	7	the	the	DET
fuelectenerg-3675	5	8	previous	previous	ADJ
fuelectenerg-3675	5	9	research	research	NOUN
fuelectenerg-3675	5	10	and	and	CCONJ
fuelectenerg-3675	5	11	results	result	NOUN
fuelectenerg-3675	5	12	of	of	ADP
fuelectenerg-3675	5	13	measurement	measurement	NOUN
fuelectenerg-3675	5	14	of	of	ADP
fuelectenerg-3675	5	15	magnetic	magnetic	ADJ
fuelectenerg-3675	5	16	flux	flux	PROPN
fuelectenerg-3675	5	17	density	density	PROPN
fuelectenerg-3675	5	18	inside	inside	ADP
fuelectenerg-3675	5	19	largediameter	largediameter	NOUN
fuelectenerg-3675	5	20	multilayer	multilayer	PROPN
fuelectenerg-3675	5	21	solenoid	solenoid	NOUN
fuelectenerg-3675	5	22	.	.	PUNCT
fuelectenerg-3675	6	1	this	this	DET
fuelectenerg-3675	6	2	solenoid	solenoid	NOUN
fuelectenerg-3675	6	3	is	be	AUX
fuelectenerg-3675	6	4	magnetising	magnetise	VERB
fuelectenerg-3675	6	5	coil	coil	NOUN
fuelectenerg-3675	6	6	of	of	ADP
fuelectenerg-3675	6	7	the	the	DET
fuelectenerg-3675	6	8	magnetometer	magnetometer	NOUN
fuelectenerg-3675	6	9	.	.	PUNCT
fuelectenerg-3675	7	1	the	the	DET
fuelectenerg-3675	7	2	paper	paper	NOUN
fuelectenerg-3675	7	3	also	also	ADV
fuelectenerg-3675	7	4	describes	describe	VERB
fuelectenerg-3675	7	5	a	a	DET
fuelectenerg-3675	7	6	system	system	NOUN
fuelectenerg-3675	7	7	of	of	ADP
fuelectenerg-3675	7	8	five	five	NUM
fuelectenerg-3675	7	9	smaller	small	ADJ
fuelectenerg-3675	7	10	coils	coil	NOUN
fuelectenerg-3675	7	11	of	of	ADP
fuelectenerg-3675	7	12	the	the	DET
fuelectenerg-3675	7	13	magnetometer	magnetometer	NOUN
fuelectenerg-3675	7	14	which	which	PRON
fuelectenerg-3675	7	15	are	be	AUX
fuelectenerg-3675	7	16	placed	place	VERB
fuelectenerg-3675	7	17	inside	inside	ADP
fuelectenerg-3675	7	18	the	the	DET
fuelectenerg-3675	7	19	large	large	ADJ
fuelectenerg-3675	7	20	solenoid	solenoid	NOUN
fuelectenerg-3675	7	21	.	.	PUNCT
fuelectenerg-3675	8	1	three	three	NUM
fuelectenerg-3675	8	2	small	small	ADJ
fuelectenerg-3675	8	3	coils	coil	NOUN
fuelectenerg-3675	8	4	are	be	AUX
fuelectenerg-3675	8	5	pickup	pickup	ADJ
fuelectenerg-3675	8	6	coils	coil	NOUN
fuelectenerg-3675	8	7	,	,	PUNCT
fuelectenerg-3675	8	8	accompanied	accompany	VERB
fuelectenerg-3675	8	9	with	with	ADP
fuelectenerg-3675	8	10	two	two	NUM
fuelectenerg-3675	8	11	compensation	compensation	NOUN
fuelectenerg-3675	8	12	coils	coil	NOUN
fuelectenerg-3675	8	13	,	,	PUNCT
fuelectenerg-3675	8	14	of	of	ADP
fuelectenerg-3675	8	15	which	which	PRON
fuelectenerg-3675	8	16	one	one	NOUN
fuelectenerg-3675	8	17	is	be	AUX
fuelectenerg-3675	8	18	an	an	DET
fuelectenerg-3675	8	19	empty	empty	ADJ
fuelectenerg-3675	8	20	coil	coil	NOUN
fuelectenerg-3675	8	21	for	for	ADP
fuelectenerg-3675	8	22	magnetic	magnetic	ADJ
fuelectenerg-3675	8	23	field	field	NOUN
fuelectenerg-3675	8	24	measurement	measurement	NOUN
fuelectenerg-3675	8	25	.	.	PUNCT
fuelectenerg-3675	9	1	the	the	DET
fuelectenerg-3675	9	2	experimental	experimental	ADJ
fuelectenerg-3675	9	3	results	result	NOUN
fuelectenerg-3675	9	4	of	of	ADP
fuelectenerg-3675	9	5	calibration	calibration	NOUN
fuelectenerg-3675	9	6	of	of	ADP
fuelectenerg-3675	9	7	this	this	DET
fuelectenerg-3675	9	8	coil	coil	NOUN
fuelectenerg-3675	9	9	system	system	NOUN
fuelectenerg-3675	9	10	have	have	AUX
fuelectenerg-3675	9	11	been	be	AUX
fuelectenerg-3675	9	12	presented	present	VERB
fuelectenerg-3675	9	13	.	.	PUNCT
fuelectenerg-3675	10	1	a	a	DET
fuelectenerg-3675	10	2	proper	proper	ADJ
fuelectenerg-3675	10	3	discussion	discussion	NOUN
fuelectenerg-3675	10	4	of	of	ADP
fuelectenerg-3675	10	5	all	all	DET
fuelectenerg-3675	10	6	the	the	DET
fuelectenerg-3675	10	7	results	result	NOUN
fuelectenerg-3675	10	8	presented	present	VERB
fuelectenerg-3675	10	9	has	have	AUX
fuelectenerg-3675	10	10	been	be	AUX
fuelectenerg-3675	10	11	also	also	ADV
fuelectenerg-3675	10	12	given	give	VERB
fuelectenerg-3675	10	13	in	in	ADP
fuelectenerg-3675	10	14	the	the	DET
fuelectenerg-3675	10	15	paper	paper	NOUN
fuelectenerg-3675	10	16	.	.	PUNCT
fuelectenerg-3675	11	1	key	key	ADJ
fuelectenerg-3675	11	2	words	word	NOUN
fuelectenerg-3675	11	3	:	:	PUNCT
fuelectenerg-3675	11	4	induction	induction	NOUN
fuelectenerg-3675	11	5	magnetometer	magnetometer	NOUN
fuelectenerg-3675	11	6	,	,	PUNCT
fuelectenerg-3675	11	7	calibration	calibration	NOUN
fuelectenerg-3675	11	8	,	,	PUNCT
fuelectenerg-3675	11	9	measurement	measurement	NOUN
fuelectenerg-3675	11	10	uncertainty	uncertainty	NOUN
fuelectenerg-3675	11	11	,	,	PUNCT
fuelectenerg-3675	11	12	hall	hall	NOUN
fuelectenerg-3675	11	13	sensor	sensor	NOUN
fuelectenerg-3675	11	14	,	,	PUNCT
fuelectenerg-3675	11	15	labview	labview	NOUN
fuelectenerg-3675	11	16	.	.	PUNCT
fuelectenerg-3675	12	1	1	1	X
fuelectenerg-3675	12	2	.	.	X
fuelectenerg-3675	12	3	introduction	introduction	NOUN
fuelectenerg-3675	12	4	iron	iron	NOUN
fuelectenerg-3675	12	5	loss	loss	NOUN
fuelectenerg-3675	12	6	in	in	ADP
fuelectenerg-3675	12	7	induction	induction	NOUN
fuelectenerg-3675	12	8	motors	motor	NOUN
fuelectenerg-3675	12	9	can	can	AUX
fuelectenerg-3675	12	10	reach	reach	VERB
fuelectenerg-3675	12	11	up	up	ADP
fuelectenerg-3675	12	12	to	to	PART
fuelectenerg-3675	12	13	20	20	NUM
fuelectenerg-3675	12	14	%	%	NOUN
fuelectenerg-3675	12	15	of	of	ADP
fuelectenerg-3675	12	16	the	the	DET
fuelectenerg-3675	12	17	total	total	ADJ
fuelectenerg-3675	12	18	losses	loss	NOUN
fuelectenerg-3675	12	19	[	[	X
fuelectenerg-3675	12	20	2	2	NUM
fuelectenerg-3675	12	21	]	]	PUNCT
fuelectenerg-3675	12	22	.	.	PUNCT
fuelectenerg-3675	13	1	large	large	ADJ
fuelectenerg-3675	13	2	efforts	effort	NOUN
fuelectenerg-3675	13	3	were	be	AUX
fuelectenerg-3675	13	4	made	make	VERB
fuelectenerg-3675	13	5	to	to	PART
fuelectenerg-3675	13	6	improve	improve	VERB
fuelectenerg-3675	13	7	production	production	NOUN
fuelectenerg-3675	13	8	of	of	ADP
fuelectenerg-3675	13	9	the	the	DET
fuelectenerg-3675	13	10	electrical	electrical	ADJ
fuelectenerg-3675	13	11	steel	steel	NOUN
fuelectenerg-3675	13	12	and	and	CCONJ
fuelectenerg-3675	13	13	to	to	PART
fuelectenerg-3675	13	14	reduce	reduce	VERB
fuelectenerg-3675	13	15	losses	loss	NOUN
fuelectenerg-3675	13	16	.	.	PUNCT
fuelectenerg-3675	14	1	amorphous	amorphous	ADJ
fuelectenerg-3675	14	2	materials	material	NOUN
fuelectenerg-3675	14	3	have	have	AUX
fuelectenerg-3675	14	4	been	be	AUX
fuelectenerg-3675	14	5	also	also	ADV
fuelectenerg-3675	14	6	used	use	VERB
fuelectenerg-3675	14	7	because	because	SCONJ
fuelectenerg-3675	14	8	of	of	ADP
fuelectenerg-3675	14	9	lower	low	ADJ
fuelectenerg-3675	14	10	losses	loss	NOUN
fuelectenerg-3675	14	11	.	.	PUNCT
fuelectenerg-3675	15	1	measurement	measurement	NOUN
fuelectenerg-3675	15	2	of	of	ADP
fuelectenerg-3675	15	3	their	their	PRON
fuelectenerg-3675	15	4	magnetic	magnetic	ADJ
fuelectenerg-3675	15	5	characteristics	characteristic	NOUN
fuelectenerg-3675	15	6	has	have	AUX
fuelectenerg-3675	15	7	become	become	VERB
fuelectenerg-3675	15	8	of	of	ADP
fuelectenerg-3675	15	9	great	great	ADJ
fuelectenerg-3675	15	10	importance	importance	NOUN
fuelectenerg-3675	15	11	in	in	ADP
fuelectenerg-3675	15	12	order	order	NOUN
fuelectenerg-3675	15	13	to	to	PART
fuelectenerg-3675	15	14	obtain	obtain	VERB
fuelectenerg-3675	15	15	reliable	reliable	ADJ
fuelectenerg-3675	15	16	data	datum	NOUN
fuelectenerg-3675	15	17	on	on	ADP
fuelectenerg-3675	15	18	power	power	NOUN
fuelectenerg-3675	15	19	loss	loss	NOUN
fuelectenerg-3675	15	20	of	of	ADP
fuelectenerg-3675	15	21	these	these	DET
fuelectenerg-3675	15	22	materials	material	NOUN
fuelectenerg-3675	15	23	.	.	PUNCT
fuelectenerg-3675	16	1	ac	ac	PROPN
fuelectenerg-3675	16	2	induction	induction	NOUN
fuelectenerg-3675	16	3	magnetometer	magnetometer	NOUN
fuelectenerg-3675	16	4	have	have	AUX
fuelectenerg-3675	16	5	proved	prove	VERB
fuelectenerg-3675	16	6	to	to	PART
fuelectenerg-3675	16	7	be	be	AUX
fuelectenerg-3675	16	8	a	a	DET
fuelectenerg-3675	16	9	powerful	powerful	ADJ
fuelectenerg-3675	16	10	tool	tool	NOUN
fuelectenerg-3675	16	11	for	for	ADP
fuelectenerg-3675	16	12	characterisation	characterisation	NOUN
fuelectenerg-3675	16	13	of	of	ADP
fuelectenerg-3675	16	14	the	the	DET
fuelectenerg-3675	16	15	ferromagnetic	ferromagnetic	ADJ
fuelectenerg-3675	16	16	materials	material	NOUN
fuelectenerg-3675	16	17	[	[	X
fuelectenerg-3675	16	18	3	3	NUM
fuelectenerg-3675	16	19	,	,	PUNCT
fuelectenerg-3675	16	20	4	4	NUM
fuelectenerg-3675	16	21	]	]	PUNCT
fuelectenerg-3675	16	22	.	.	PUNCT
fuelectenerg-3675	17	1	induction	induction	NOUN
fuelectenerg-3675	17	2	magnetometer	magnetometer	PROPN
fuelectenerg-3675	17	3	uses	use	VERB
fuelectenerg-3675	17	4	a	a	DET
fuelectenerg-3675	17	5	long	long	ADJ
fuelectenerg-3675	17	6	solenoid	solenoid	NOUN
fuelectenerg-3675	17	7	for	for	ADP
fuelectenerg-3675	17	8	magnetisation	magnetisation	NOUN
fuelectenerg-3675	17	9	of	of	ADP
fuelectenerg-3675	17	10	the	the	DET
fuelectenerg-3675	17	11	sample	sample	NOUN
fuelectenerg-3675	17	12	[	[	X
fuelectenerg-3675	17	13	3	3	NUM
fuelectenerg-3675	17	14	,	,	PUNCT
fuelectenerg-3675	17	15	4	4	NUM
fuelectenerg-3675	17	16	]	]	PUNCT
fuelectenerg-3675	17	17	.	.	PUNCT
fuelectenerg-3675	18	1	a	a	DET
fuelectenerg-3675	18	2	pickup	pickup	NOUN
fuelectenerg-3675	18	3	coil	coil	NOUN
fuelectenerg-3675	18	4	is	be	AUX
fuelectenerg-3675	18	5	placed	place	VERB
fuelectenerg-3675	18	6	inside	inside	ADP
fuelectenerg-3675	18	7	the	the	DET
fuelectenerg-3675	18	8	long	long	ADJ
fuelectenerg-3675	18	9	solenoid	solenoid	NOUN
fuelectenerg-3675	18	10	and	and	CCONJ
fuelectenerg-3675	18	11	used	use	VERB
fuelectenerg-3675	18	12	for	for	ADP
fuelectenerg-3675	18	13	measurement	measurement	NOUN
fuelectenerg-3675	18	14	of	of	ADP
fuelectenerg-3675	18	15	the	the	DET
fuelectenerg-3675	18	16	magnetic	magnetic	PROPN
fuelectenerg-3675	18	17	flux	flux	NOUN
fuelectenerg-3675	18	18	density	density	NOUN
fuelectenerg-3675	18	19	in	in	ADP
fuelectenerg-3675	18	20	the	the	DET
fuelectenerg-3675	18	21	sample	sample	NOUN
fuelectenerg-3675	18	22	of	of	ADP
fuelectenerg-3675	18	23	ferromagnetic	ferromagnetic	ADJ
fuelectenerg-3675	18	24	material	material	NOUN
fuelectenerg-3675	18	25	.	.	PUNCT
fuelectenerg-3675	19	1	a	a	DET
fuelectenerg-3675	19	2	lateral	lateral	ADJ
fuelectenerg-3675	19	3	dimension	dimension	NOUN
fuelectenerg-3675	19	4	of	of	ADP
fuelectenerg-3675	19	5	the	the	DET
fuelectenerg-3675	19	6	sample	sample	NOUN
fuelectenerg-3675	19	7	is	be	AUX
fuelectenerg-3675	19	8	not	not	PART
fuelectenerg-3675	19	9	large	large	ADJ
fuelectenerg-3675	19	10	,	,	PUNCT
fuelectenerg-3675	19	11	usually	usually	ADV
fuelectenerg-3675	19	12	in	in	ADP
fuelectenerg-3675	19	13	order	order	NOUN
fuelectenerg-3675	19	14	of	of	ADP
fuelectenerg-3675	19	15	several	several	ADJ
fuelectenerg-3675	19	16	millimetres	millimetre	NOUN
fuelectenerg-3675	19	17	(	(	PUNCT
fuelectenerg-3675	19	18	diameter	diameter	NOUN
fuelectenerg-3675	19	19	of	of	ADP
fuelectenerg-3675	19	20	wire	wire	NOUN
fuelectenerg-3675	19	21	or	or	CCONJ
fuelectenerg-3675	19	22	bar	bar	VERB
fuelectenerg-3675	19	23	and	and	CCONJ
fuelectenerg-3675	19	24	width	width	NOUN
fuelectenerg-3675	19	25	of	of	ADP
fuelectenerg-3675	19	26	strips	strip	NOUN
fuelectenerg-3675	19	27	)	)	PUNCT
fuelectenerg-3675	19	28	,	,	PUNCT
fuelectenerg-3675	19	29	while	while	SCONJ
fuelectenerg-3675	19	30	its	its	PRON
fuelectenerg-3675	19	31	length	length	NOUN
fuelectenerg-3675	19	32	usually	usually	ADV
fuelectenerg-3675	19	33	amounts	amount	VERB
fuelectenerg-3675	19	34	several	several	ADJ
fuelectenerg-3675	19	35	centimetres	centimetre	NOUN
fuelectenerg-3675	19	36	and	and	CCONJ
fuelectenerg-3675	19	37	may	may	AUX
fuelectenerg-3675	19	38	be	be	AUX
fuelectenerg-3675	19	39	up	up	ADP
fuelectenerg-3675	19	40	to	to	PART
fuelectenerg-3675	19	41	10	10	NUM
fuelectenerg-3675	19	42	-	-	SYM
fuelectenerg-3675	19	43	15	15	NUM
fuelectenerg-3675	19	44	cm	cm	NOUN
fuelectenerg-3675	19	45	.	.	PUNCT
fuelectenerg-3675	20	1	another	another	DET
fuelectenerg-3675	20	2	pickup	pickup	ADJ
fuelectenerg-3675	20	3	coil	coil	NOUN
fuelectenerg-3675	20	4	may	may	AUX
fuelectenerg-3675	20	5	be	be	AUX
fuelectenerg-3675	20	6	also	also	ADV
fuelectenerg-3675	20	7	placed	place	VERB
fuelectenerg-3675	20	8	inside	inside	ADP
fuelectenerg-3675	20	9	the	the	DET
fuelectenerg-3675	20	10	long	long	ADJ
fuelectenerg-3675	20	11	solenoid	solenoid	NOUN
fuelectenerg-3675	20	12	,	,	PUNCT
fuelectenerg-3675	20	13	without	without	ADP
fuelectenerg-3675	20	14	the	the	DET
fuelectenerg-3675	20	15	sample	sample	NOUN
fuelectenerg-3675	20	16	,	,	PUNCT
fuelectenerg-3675	20	17	and	and	CCONJ
fuelectenerg-3675	20	18	used	use	VERB
fuelectenerg-3675	20	19	for	for	ADP
fuelectenerg-3675	20	20	measurement	measurement	NOUN
fuelectenerg-3675	20	21	of	of	ADP
fuelectenerg-3675	20	22	the	the	DET
fuelectenerg-3675	20	23	magnetic	magnetic	ADJ
fuelectenerg-3675	20	24	field	field	NOUN
fuelectenerg-3675	20	25	.	.	PUNCT
fuelectenerg-3675	21	1	received	receive	VERB
fuelectenerg-3675	21	2	february	february	PROPN
fuelectenerg-3675	21	3	25	25	NUM
fuelectenerg-3675	21	4	,	,	PUNCT
fuelectenerg-3675	21	5	2018	2018	NUM
fuelectenerg-3675	21	6	;	;	PUNCT
fuelectenerg-3675	21	7	received	receive	VERB
fuelectenerg-3675	21	8	in	in	ADP
fuelectenerg-3675	21	9	revised	revise	VERB
fuelectenerg-3675	21	10	form	form	NOUN
fuelectenerg-3675	21	11	july	july	PROPN
fuelectenerg-3675	21	12	5	5	NUM
fuelectenerg-3675	21	13	,	,	PUNCT
fuelectenerg-3675	21	14	2018	2018	NUM
fuelectenerg-3675	21	15	corresponding	correspond	VERB
fuelectenerg-3675	21	16	author	author	NOUN
fuelectenerg-3675	21	17	:	:	PUNCT
fuelectenerg-3675	21	18	branko	branko	PROPN
fuelectenerg-3675	21	19	koprivica	koprivica	PROPN
fuelectenerg-3675	21	20	university	university	PROPN
fuelectenerg-3675	21	21	of	of	ADP
fuelectenerg-3675	21	22	kragujevac	kragujevac	PROPN
fuelectenerg-3675	21	23	,	,	PUNCT
fuelectenerg-3675	21	24	faculty	faculty	NOUN
fuelectenerg-3675	21	25	of	of	ADP
fuelectenerg-3675	21	26	technical	technical	ADJ
fuelectenerg-3675	21	27	sciences	science	NOUN
fuelectenerg-3675	21	28	,	,	PUNCT
fuelectenerg-3675	21	29	svetog	svetog	NOUN
fuelectenerg-3675	21	30	save	save	VERB
fuelectenerg-3675	21	31	65	65	NUM
fuelectenerg-3675	21	32	,	,	PUNCT
fuelectenerg-3675	21	33	32000	32000	NUM
fuelectenerg-3675	21	34	ĉaĉak	ĉaĉak	NOUN
fuelectenerg-3675	21	35	,	,	PUNCT
fuelectenerg-3675	21	36	serbia	serbia	PROPN
fuelectenerg-3675	21	37	(	(	PUNCT
fuelectenerg-3675	21	38	e	e	NOUN
fuelectenerg-3675	21	39	-	-	NOUN
fuelectenerg-3675	21	40	mail	mail	NOUN
fuelectenerg-3675	21	41	:	:	PUNCT
fuelectenerg-3675	21	42	branko.koprivica@ftn.kg.ac.rs	branko.koprivica@ftn.kg.ac.rs	ADJ
fuelectenerg-3675	21	43	)	)	PUNCT
fuelectenerg-3675	21	44	*	*	PUNCT
fuelectenerg-3675	21	45	an	an	DET
fuelectenerg-3675	21	46	earlier	early	ADJ
fuelectenerg-3675	21	47	version	version	NOUN
fuelectenerg-3675	21	48	of	of	ADP
fuelectenerg-3675	21	49	this	this	DET
fuelectenerg-3675	21	50	paper	paper	NOUN
fuelectenerg-3675	21	51	was	be	AUX
fuelectenerg-3675	21	52	presented	present	VERB
fuelectenerg-3675	21	53	at	at	ADP
fuelectenerg-3675	21	54	the	the	DET
fuelectenerg-3675	21	55	13th	13th	ADJ
fuelectenerg-3675	21	56	international	international	ADJ
fuelectenerg-3675	21	57	conference	conference	NOUN
fuelectenerg-3675	21	58	on	on	ADP
fuelectenerg-3675	21	59	applied	applied	ADJ
fuelectenerg-3675	21	60	electromagnetics	electromagnetic	NOUN
fuelectenerg-3675	21	61	(	(	PUNCT
fuelectenerg-3675	21	62	пес	пес	ADJ
fuelectenerg-3675	21	63	2017	2017	NUM
fuelectenerg-3675	21	64	)	)	PUNCT
fuelectenerg-3675	21	65	,	,	PUNCT
fuelectenerg-3675	21	66	august	august	PROPN
fuelectenerg-3675	21	67	31	31	NUM
fuelectenerg-3675	21	68	september	september	PROPN
fuelectenerg-3675	21	69	01	01	NUM
fuelectenerg-3675	21	70	,	,	PUNCT
fuelectenerg-3675	21	71	2017	2017	NUM
fuelectenerg-3675	21	72	,	,	PUNCT
fuelectenerg-3675	21	73	in	in	ADP
fuelectenerg-3675	21	74	niš	niš	NOUN
fuelectenerg-3675	21	75	,	,	PUNCT
fuelectenerg-3675	21	76	serbia	serbia	PROPN
fuelectenerg-3675	21	77	[	[	X
fuelectenerg-3675	21	78	1	1	NUM
fuelectenerg-3675	21	79	]	]	PUNCT
fuelectenerg-3675	21	80	.	.	PUNCT
fuelectenerg-3675	22	1	614	614	NUM
fuelectenerg-3675	22	2	b.	b.	PROPN
fuelectenerg-3675	22	3	koprivica	koprivica	PROPN
fuelectenerg-3675	22	4	,	,	PUNCT
fuelectenerg-3675	22	5	m.	m.	NOUN
fuelectenerg-3675	22	6	šućurović	šućurović	PROPN
fuelectenerg-3675	22	7	,	,	PUNCT
fuelectenerg-3675	22	8	a.	a.	NOUN
fuelectenerg-3675	22	9	milovanović	milovanović	NOUN
fuelectenerg-3675	22	10	in	in	ADP
fuelectenerg-3675	22	11	general	general	ADJ
fuelectenerg-3675	22	12	,	,	PUNCT
fuelectenerg-3675	22	13	it	it	PRON
fuelectenerg-3675	22	14	is	be	AUX
fuelectenerg-3675	22	15	easy	easy	ADJ
fuelectenerg-3675	22	16	to	to	PART
fuelectenerg-3675	22	17	control	control	VERB
fuelectenerg-3675	22	18	a	a	DET
fuelectenerg-3675	22	19	time	time	NOUN
fuelectenerg-3675	22	20	waveform	waveform	NOUN
fuelectenerg-3675	22	21	of	of	ADP
fuelectenerg-3675	22	22	the	the	DET
fuelectenerg-3675	22	23	magnetic	magnetic	ADJ
fuelectenerg-3675	22	24	field	field	NOUN
fuelectenerg-3675	22	25	created	create	VERB
fuelectenerg-3675	22	26	by	by	ADP
fuelectenerg-3675	22	27	the	the	DET
fuelectenerg-3675	22	28	long	long	ADJ
fuelectenerg-3675	22	29	solenoid	solenoid	NOUN
fuelectenerg-3675	22	30	.	.	PUNCT
fuelectenerg-3675	23	1	therefore	therefore	ADV
fuelectenerg-3675	23	2	,	,	PUNCT
fuelectenerg-3675	23	3	the	the	DET
fuelectenerg-3675	23	4	magnetic	magnetic	ADJ
fuelectenerg-3675	23	5	field	field	NOUN
fuelectenerg-3675	23	6	has	have	AUX
fuelectenerg-3675	23	7	desired	desire	VERB
fuelectenerg-3675	23	8	shape	shape	NOUN
fuelectenerg-3675	23	9	,	,	PUNCT
fuelectenerg-3675	23	10	while	while	SCONJ
fuelectenerg-3675	23	11	the	the	DET
fuelectenerg-3675	23	12	magnetic	magnetic	ADJ
fuelectenerg-3675	23	13	flux	flux	NOUN
fuelectenerg-3675	23	14	density	density	NOUN
fuelectenerg-3675	23	15	shape	shape	NOUN
fuelectenerg-3675	23	16	depends	depend	VERB
fuelectenerg-3675	23	17	on	on	ADP
fuelectenerg-3675	23	18	the	the	DET
fuelectenerg-3675	23	19	material	material	NOUN
fuelectenerg-3675	23	20	response	response	NOUN
fuelectenerg-3675	23	21	.	.	PUNCT
fuelectenerg-3675	24	1	when	when	SCONJ
fuelectenerg-3675	24	2	it	it	PRON
fuelectenerg-3675	24	3	is	be	AUX
fuelectenerg-3675	24	4	used	use	VERB
fuelectenerg-3675	24	5	along	along	ADP
fuelectenerg-3675	24	6	with	with	ADP
fuelectenerg-3675	24	7	the	the	DET
fuelectenerg-3675	24	8	personal	personal	ADJ
fuelectenerg-3675	24	9	computer	computer	NOUN
fuelectenerg-3675	24	10	,	,	PUNCT
fuelectenerg-3675	24	11	as	as	ADP
fuelectenerg-3675	24	12	a	a	DET
fuelectenerg-3675	24	13	digital	digital	ADJ
fuelectenerg-3675	24	14	measurement	measurement	NOUN
fuelectenerg-3675	24	15	setup	setup	NOUN
fuelectenerg-3675	24	16	,	,	PUNCT
fuelectenerg-3675	24	17	it	it	PRON
fuelectenerg-3675	24	18	enables	enable	VERB
fuelectenerg-3675	24	19	performing	perform	VERB
fuelectenerg-3675	24	20	of	of	ADP
fuelectenerg-3675	24	21	very	very	ADV
fuelectenerg-3675	24	22	complex	complex	ADJ
fuelectenerg-3675	24	23	experiments	experiment	NOUN
fuelectenerg-3675	24	24	,	,	PUNCT
fuelectenerg-3675	24	25	such	such	ADJ
fuelectenerg-3675	24	26	as	as	ADP
fuelectenerg-3675	24	27	those	those	PRON
fuelectenerg-3675	24	28	for	for	ADP
fuelectenerg-3675	24	29	measurement	measurement	NOUN
fuelectenerg-3675	24	30	of	of	ADP
fuelectenerg-3675	24	31	first	first	ADJ
fuelectenerg-3675	24	32	-	-	PUNCT
fuelectenerg-3675	24	33	order	order	NOUN
fuelectenerg-3675	24	34	reversal	reversal	NOUN
fuelectenerg-3675	24	35	curves	curve	NOUN
fuelectenerg-3675	24	36	[	[	X
fuelectenerg-3675	24	37	3	3	NUM
fuelectenerg-3675	24	38	,	,	PUNCT
fuelectenerg-3675	24	39	4	4	NUM
fuelectenerg-3675	24	40	]	]	PUNCT
fuelectenerg-3675	24	41	.	.	PUNCT
fuelectenerg-3675	25	1	this	this	DET
fuelectenerg-3675	25	2	measurement	measurement	NOUN
fuelectenerg-3675	25	3	method	method	NOUN
fuelectenerg-3675	25	4	is	be	AUX
fuelectenerg-3675	25	5	based	base	VERB
fuelectenerg-3675	25	6	on	on	ADP
fuelectenerg-3675	25	7	two	two	NUM
fuelectenerg-3675	25	8	basic	basic	ADJ
fuelectenerg-3675	25	9	laws	law	NOUN
fuelectenerg-3675	25	10	of	of	ADP
fuelectenerg-3675	25	11	magnetism	magnetism	NOUN
fuelectenerg-3675	25	12	ampere	ampere	PROPN
fuelectenerg-3675	25	13	’s	’s	PART
fuelectenerg-3675	25	14	law	law	NOUN
fuelectenerg-3675	25	15	for	for	ADP
fuelectenerg-3675	25	16	magnetising	magnetise	VERB
fuelectenerg-3675	25	17	coil	coil	NOUN
fuelectenerg-3675	25	18	and	and	CCONJ
fuelectenerg-3675	25	19	faraday	faraday	PROPN
fuelectenerg-3675	25	20	’s	’s	PART
fuelectenerg-3675	25	21	law	law	NOUN
fuelectenerg-3675	25	22	for	for	ADP
fuelectenerg-3675	25	23	pickup	pickup	ADJ
fuelectenerg-3675	25	24	coil	coil	NOUN
fuelectenerg-3675	25	25	.	.	PUNCT
fuelectenerg-3675	26	1	in	in	ADP
fuelectenerg-3675	26	2	the	the	DET
fuelectenerg-3675	26	3	case	case	NOUN
fuelectenerg-3675	26	4	when	when	SCONJ
fuelectenerg-3675	26	5	a	a	DET
fuelectenerg-3675	26	6	long	long	ADJ
fuelectenerg-3675	26	7	solenoid	solenoid	NOUN
fuelectenerg-3675	26	8	with	with	ADP
fuelectenerg-3675	26	9	small	small	ADJ
fuelectenerg-3675	26	10	diameter	diameter	NOUN
fuelectenerg-3675	26	11	is	be	AUX
fuelectenerg-3675	26	12	used	use	VERB
fuelectenerg-3675	26	13	as	as	ADP
fuelectenerg-3675	26	14	magnetising	magnetise	VERB
fuelectenerg-3675	26	15	coil	coil	NOUN
fuelectenerg-3675	26	16	,	,	PUNCT
fuelectenerg-3675	26	17	according	accord	VERB
fuelectenerg-3675	26	18	to	to	ADP
fuelectenerg-3675	26	19	the	the	DET
fuelectenerg-3675	26	20	ampere	ampere	NOUN
fuelectenerg-3675	26	21	’s	’s	PART
fuelectenerg-3675	26	22	law	law	NOUN
fuelectenerg-3675	26	23	,	,	PUNCT
fuelectenerg-3675	26	24	the	the	DET
fuelectenerg-3675	26	25	magnetic	magnetic	ADJ
fuelectenerg-3675	26	26	field	field	NOUN
fuelectenerg-3675	26	27	is	be	AUX
fuelectenerg-3675	26	28	homogeneous	homogeneous	ADJ
fuelectenerg-3675	26	29	and	and	CCONJ
fuelectenerg-3675	26	30	has	have	VERB
fuelectenerg-3675	26	31	longitudinal	longitudinal	ADJ
fuelectenerg-3675	26	32	direction	direction	NOUN
fuelectenerg-3675	26	33	and	and	CCONJ
fuelectenerg-3675	26	34	constant	constant	ADJ
fuelectenerg-3675	26	35	amplitude	amplitude	NOUN
fuelectenerg-3675	26	36	[	[	X
fuelectenerg-3675	26	37	4	4	NUM
fuelectenerg-3675	26	38	]	]	PUNCT
fuelectenerg-3675	26	39	.	.	PUNCT
fuelectenerg-3675	27	1	however	however	ADV
fuelectenerg-3675	27	2	,	,	PUNCT
fuelectenerg-3675	27	3	this	this	PRON
fuelectenerg-3675	27	4	is	be	AUX
fuelectenerg-3675	27	5	not	not	PART
fuelectenerg-3675	27	6	easy	easy	ADJ
fuelectenerg-3675	27	7	to	to	PART
fuelectenerg-3675	27	8	achieve	achieve	VERB
fuelectenerg-3675	27	9	in	in	ADP
fuelectenerg-3675	27	10	practice	practice	NOUN
fuelectenerg-3675	27	11	and	and	CCONJ
fuelectenerg-3675	27	12	in	in	ADP
fuelectenerg-3675	27	13	many	many	ADJ
fuelectenerg-3675	27	14	cases	case	NOUN
fuelectenerg-3675	27	15	the	the	DET
fuelectenerg-3675	27	16	magnetic	magnetic	ADJ
fuelectenerg-3675	27	17	field	field	NOUN
fuelectenerg-3675	27	18	is	be	AUX
fuelectenerg-3675	27	19	homogenous	homogenous	ADJ
fuelectenerg-3675	27	20	only	only	ADV
fuelectenerg-3675	27	21	in	in	ADP
fuelectenerg-3675	27	22	the	the	DET
fuelectenerg-3675	27	23	middle	middle	ADJ
fuelectenerg-3675	27	24	zone	zone	NOUN
fuelectenerg-3675	27	25	of	of	ADP
fuelectenerg-3675	27	26	the	the	DET
fuelectenerg-3675	27	27	solenoid	solenoid	NOUN
fuelectenerg-3675	27	28	.	.	PUNCT
fuelectenerg-3675	28	1	this	this	PRON
fuelectenerg-3675	28	2	limits	limit	VERB
fuelectenerg-3675	28	3	the	the	DET
fuelectenerg-3675	28	4	length	length	NOUN
fuelectenerg-3675	28	5	of	of	ADP
fuelectenerg-3675	28	6	the	the	DET
fuelectenerg-3675	28	7	pickup	pickup	ADJ
fuelectenerg-3675	28	8	coil	coil	NOUN
fuelectenerg-3675	28	9	.	.	PUNCT
fuelectenerg-3675	29	1	because	because	SCONJ
fuelectenerg-3675	29	2	of	of	ADP
fuelectenerg-3675	29	3	this	this	DET
fuelectenerg-3675	29	4	inhomogeneity	inhomogeneity	NOUN
fuelectenerg-3675	29	5	,	,	PUNCT
fuelectenerg-3675	29	6	the	the	DET
fuelectenerg-3675	29	7	magnetic	magnetic	ADJ
fuelectenerg-3675	29	8	field	field	NOUN
fuelectenerg-3675	29	9	can	can	AUX
fuelectenerg-3675	29	10	not	not	PART
fuelectenerg-3675	29	11	be	be	AUX
fuelectenerg-3675	29	12	always	always	ADV
fuelectenerg-3675	29	13	accurately	accurately	ADV
fuelectenerg-3675	29	14	calculated	calculate	VERB
fuelectenerg-3675	29	15	according	accord	VERB
fuelectenerg-3675	29	16	to	to	ADP
fuelectenerg-3675	29	17	ampere	ampere	PROPN
fuelectenerg-3675	29	18	’s	’s	PART
fuelectenerg-3675	29	19	law	law	NOUN
fuelectenerg-3675	29	20	,	,	PUNCT
fuelectenerg-3675	29	21	using	use	VERB
fuelectenerg-3675	29	22	measured	measured	ADJ
fuelectenerg-3675	29	23	current	current	NOUN
fuelectenerg-3675	29	24	of	of	ADP
fuelectenerg-3675	29	25	the	the	DET
fuelectenerg-3675	29	26	solenoid	solenoid	NOUN
fuelectenerg-3675	29	27	.	.	PUNCT
fuelectenerg-3675	30	1	the	the	DET
fuelectenerg-3675	30	2	faraday	faraday	PROPN
fuelectenerg-3675	30	3	’s	’s	PART
fuelectenerg-3675	30	4	law	law	NOUN
fuelectenerg-3675	30	5	applied	apply	VERB
fuelectenerg-3675	30	6	to	to	ADP
fuelectenerg-3675	30	7	the	the	DET
fuelectenerg-3675	30	8	pickup	pickup	NOUN
fuelectenerg-3675	30	9	coil	coil	NOUN
fuelectenerg-3675	30	10	may	may	AUX
fuelectenerg-3675	30	11	also	also	ADV
fuelectenerg-3675	30	12	provide	provide	VERB
fuelectenerg-3675	30	13	inaccurate	inaccurate	ADJ
fuelectenerg-3675	30	14	result	result	NOUN
fuelectenerg-3675	30	15	if	if	SCONJ
fuelectenerg-3675	30	16	the	the	DET
fuelectenerg-3675	30	17	pickup	pickup	NOUN
fuelectenerg-3675	30	18	coil	coil	NOUN
fuelectenerg-3675	30	19	is	be	AUX
fuelectenerg-3675	30	20	placed	place	VERB
fuelectenerg-3675	30	21	in	in	ADP
fuelectenerg-3675	30	22	the	the	DET
fuelectenerg-3675	30	23	zone	zone	NOUN
fuelectenerg-3675	30	24	where	where	SCONJ
fuelectenerg-3675	30	25	the	the	DET
fuelectenerg-3675	30	26	magnetic	magnetic	ADJ
fuelectenerg-3675	30	27	field	field	NOUN
fuelectenerg-3675	30	28	is	be	AUX
fuelectenerg-3675	30	29	not	not	PART
fuelectenerg-3675	30	30	homogeneous	homogeneous	ADJ
fuelectenerg-3675	30	31	.	.	PUNCT
fuelectenerg-3675	31	1	therefore	therefore	ADV
fuelectenerg-3675	31	2	,	,	PUNCT
fuelectenerg-3675	31	3	the	the	DET
fuelectenerg-3675	31	4	whole	whole	ADJ
fuelectenerg-3675	31	5	system	system	NOUN
fuelectenerg-3675	31	6	needs	need	VERB
fuelectenerg-3675	31	7	to	to	PART
fuelectenerg-3675	31	8	be	be	AUX
fuelectenerg-3675	31	9	calibrated	calibrate	VERB
fuelectenerg-3675	31	10	.	.	PUNCT
fuelectenerg-3675	32	1	in	in	ADP
fuelectenerg-3675	32	2	this	this	DET
fuelectenerg-3675	32	3	paper	paper	NOUN
fuelectenerg-3675	32	4	,	,	PUNCT
fuelectenerg-3675	32	5	a	a	DET
fuelectenerg-3675	32	6	calibration	calibration	NOUN
fuelectenerg-3675	32	7	procedure	procedure	NOUN
fuelectenerg-3675	32	8	will	will	AUX
fuelectenerg-3675	32	9	be	be	AUX
fuelectenerg-3675	32	10	described	describe	VERB
fuelectenerg-3675	32	11	and	and	CCONJ
fuelectenerg-3675	32	12	performed	perform	VERB
fuelectenerg-3675	32	13	on	on	ADP
fuelectenerg-3675	32	14	the	the	DET
fuelectenerg-3675	32	15	coil	coil	NOUN
fuelectenerg-3675	32	16	systems	system	NOUN
fuelectenerg-3675	32	17	of	of	ADP
fuelectenerg-3675	32	18	one	one	NUM
fuelectenerg-3675	32	19	old	old	ADJ
fuelectenerg-3675	32	20	ac	ac	PROPN
fuelectenerg-3675	32	21	induction	induction	NOUN
fuelectenerg-3675	32	22	magnetometer	magnetometer	NOUN
fuelectenerg-3675	32	23	ferrotester	ferrotester	NOUN
fuelectenerg-3675	32	24	2738	2738	NUM
fuelectenerg-3675	32	25	/	/	SYM
fuelectenerg-3675	32	26	s-3	s-3	NOUN
fuelectenerg-3675	32	27	.	.	PUNCT
fuelectenerg-3675	33	1	as	as	ADP
fuelectenerg-3675	33	2	an	an	DET
fuelectenerg-3675	33	3	initial	initial	ADJ
fuelectenerg-3675	33	4	step	step	NOUN
fuelectenerg-3675	33	5	in	in	ADP
fuelectenerg-3675	33	6	the	the	DET
fuelectenerg-3675	33	7	calibration	calibration	NOUN
fuelectenerg-3675	33	8	of	of	ADP
fuelectenerg-3675	33	9	the	the	DET
fuelectenerg-3675	33	10	magnetometer	magnetometer	NOUN
fuelectenerg-3675	33	11	,	,	PUNCT
fuelectenerg-3675	33	12	a	a	DET
fuelectenerg-3675	33	13	homogeneity	homogeneity	NOUN
fuelectenerg-3675	33	14	of	of	ADP
fuelectenerg-3675	33	15	the	the	DET
fuelectenerg-3675	33	16	magnetic	magnetic	ADJ
fuelectenerg-3675	33	17	field	field	NOUN
fuelectenerg-3675	33	18	inside	inside	ADP
fuelectenerg-3675	33	19	a	a	DET
fuelectenerg-3675	33	20	largediameter	largediameter	NOUN
fuelectenerg-3675	33	21	multilayer	multilayer	NOUN
fuelectenerg-3675	33	22	solenoid	solenoid	NOUN
fuelectenerg-3675	33	23	(	(	PUNCT
fuelectenerg-3675	33	24	large	large	ADJ
fuelectenerg-3675	33	25	solenoid	solenoid	NOUN
fuelectenerg-3675	33	26	)	)	PUNCT
fuelectenerg-3675	33	27	has	have	AUX
fuelectenerg-3675	33	28	been	be	AUX
fuelectenerg-3675	33	29	investigated	investigate	VERB
fuelectenerg-3675	33	30	in	in	ADP
fuelectenerg-3675	33	31	the	the	DET
fuelectenerg-3675	33	32	prior	prior	ADJ
fuelectenerg-3675	33	33	research	research	NOUN
fuelectenerg-3675	34	1	[	[	X
fuelectenerg-3675	34	2	1	1	NUM
fuelectenerg-3675	34	3	]	]	PUNCT
fuelectenerg-3675	34	4	.	.	PUNCT
fuelectenerg-3675	35	1	it	it	PRON
fuelectenerg-3675	35	2	has	have	AUX
fuelectenerg-3675	35	3	been	be	AUX
fuelectenerg-3675	35	4	found	find	VERB
fuelectenerg-3675	35	5	that	that	SCONJ
fuelectenerg-3675	35	6	the	the	DET
fuelectenerg-3675	35	7	homogeneity	homogeneity	NOUN
fuelectenerg-3675	35	8	zone	zone	NOUN
fuelectenerg-3675	35	9	covers	cover	VERB
fuelectenerg-3675	35	10	only	only	ADV
fuelectenerg-3675	35	11	one	one	NUM
fuelectenerg-3675	35	12	third	third	NOUN
fuelectenerg-3675	35	13	of	of	ADP
fuelectenerg-3675	35	14	the	the	DET
fuelectenerg-3675	35	15	solenoid	solenoid	NOUN
fuelectenerg-3675	35	16	(	(	PUNCT
fuelectenerg-3675	35	17	its	its	PRON
fuelectenerg-3675	35	18	central	central	ADJ
fuelectenerg-3675	35	19	part	part	NOUN
fuelectenerg-3675	35	20	)	)	PUNCT
fuelectenerg-3675	35	21	.	.	PUNCT
fuelectenerg-3675	36	1	a	a	DET
fuelectenerg-3675	36	2	variation	variation	NOUN
fuelectenerg-3675	36	3	of	of	ADP
fuelectenerg-3675	36	4	the	the	DET
fuelectenerg-3675	36	5	magnetic	magnetic	ADJ
fuelectenerg-3675	36	6	field	field	NOUN
fuelectenerg-3675	36	7	in	in	ADP
fuelectenerg-3675	36	8	this	this	DET
fuelectenerg-3675	36	9	zone	zone	NOUN
fuelectenerg-3675	36	10	was	be	AUX
fuelectenerg-3675	36	11	less	less	ADJ
fuelectenerg-3675	36	12	than	than	ADP
fuelectenerg-3675	36	13	1	1	NUM
fuelectenerg-3675	36	14	%	%	NOUN
fuelectenerg-3675	36	15	of	of	ADP
fuelectenerg-3675	36	16	its	its	PRON
fuelectenerg-3675	36	17	maximum	maximum	ADJ
fuelectenerg-3675	36	18	value	value	NOUN
fuelectenerg-3675	36	19	.	.	PUNCT
fuelectenerg-3675	37	1	an	an	DET
fuelectenerg-3675	37	2	inner	inner	ADJ
fuelectenerg-3675	37	3	coil	coil	NOUN
fuelectenerg-3675	37	4	system	system	NOUN
fuelectenerg-3675	37	5	of	of	ADP
fuelectenerg-3675	37	6	this	this	DET
fuelectenerg-3675	37	7	magnetometer	magnetometer	NOUN
fuelectenerg-3675	37	8	contains	contain	VERB
fuelectenerg-3675	37	9	five	five	NUM
fuelectenerg-3675	37	10	smaller	small	ADJ
fuelectenerg-3675	37	11	coils	coil	NOUN
fuelectenerg-3675	37	12	,	,	PUNCT
fuelectenerg-3675	37	13	one	one	NUM
fuelectenerg-3675	37	14	coil	coil	NOUN
fuelectenerg-3675	37	15	for	for	ADP
fuelectenerg-3675	37	16	measurement	measurement	NOUN
fuelectenerg-3675	37	17	of	of	ADP
fuelectenerg-3675	37	18	the	the	DET
fuelectenerg-3675	37	19	magnetic	magnetic	ADJ
fuelectenerg-3675	37	20	field	field	NOUN
fuelectenerg-3675	37	21	(	(	PUNCT
fuelectenerg-3675	37	22	empty	empty	ADJ
fuelectenerg-3675	37	23	coil	coil	NOUN
fuelectenerg-3675	37	24	)	)	PUNCT
fuelectenerg-3675	37	25	and	and	CCONJ
fuelectenerg-3675	37	26	two	two	NUM
fuelectenerg-3675	37	27	pairs	pair	NOUN
fuelectenerg-3675	37	28	of	of	ADP
fuelectenerg-3675	37	29	coils	coil	NOUN
fuelectenerg-3675	37	30	in	in	ADP
fuelectenerg-3675	37	31	mutual	mutual	ADJ
fuelectenerg-3675	37	32	opposition	opposition	NOUN
fuelectenerg-3675	37	33	for	for	ADP
fuelectenerg-3675	37	34	measurement	measurement	NOUN
fuelectenerg-3675	37	35	of	of	ADP
fuelectenerg-3675	37	36	the	the	DET
fuelectenerg-3675	37	37	magnetic	magnetic	PROPN
fuelectenerg-3675	37	38	flux	flux	NOUN
fuelectenerg-3675	37	39	density	density	NOUN
fuelectenerg-3675	37	40	and	and	CCONJ
fuelectenerg-3675	37	41	magnetisation	magnetisation	NOUN
fuelectenerg-3675	37	42	.	.	PUNCT
fuelectenerg-3675	38	1	the	the	DET
fuelectenerg-3675	38	2	calibration	calibration	NOUN
fuelectenerg-3675	38	3	of	of	ADP
fuelectenerg-3675	38	4	this	this	DET
fuelectenerg-3675	38	5	coil	coil	NOUN
fuelectenerg-3675	38	6	system	system	NOUN
fuelectenerg-3675	38	7	,	,	PUNCT
fuelectenerg-3675	38	8	along	along	ADP
fuelectenerg-3675	38	9	with	with	ADP
fuelectenerg-3675	38	10	the	the	DET
fuelectenerg-3675	38	11	calibration	calibration	NOUN
fuelectenerg-3675	38	12	of	of	ADP
fuelectenerg-3675	38	13	the	the	DET
fuelectenerg-3675	38	14	magnetising	magnetising	PROPN
fuelectenerg-3675	38	15	solenoid	solenoid	NOUN
fuelectenerg-3675	38	16	,	,	PUNCT
fuelectenerg-3675	38	17	will	will	AUX
fuelectenerg-3675	38	18	be	be	AUX
fuelectenerg-3675	38	19	presented	present	VERB
fuelectenerg-3675	38	20	in	in	ADP
fuelectenerg-3675	38	21	this	this	DET
fuelectenerg-3675	38	22	paper	paper	NOUN
fuelectenerg-3675	38	23	.	.	PUNCT
fuelectenerg-3675	39	1	a	a	DET
fuelectenerg-3675	39	2	calibration	calibration	NOUN
fuelectenerg-3675	39	3	of	of	ADP
fuelectenerg-3675	39	4	the	the	DET
fuelectenerg-3675	39	5	magnetometer	magnetometer	NOUN
fuelectenerg-3675	39	6	has	have	AUX
fuelectenerg-3675	39	7	been	be	AUX
fuelectenerg-3675	39	8	performed	perform	VERB
fuelectenerg-3675	39	9	using	use	VERB
fuelectenerg-3675	39	10	a	a	DET
fuelectenerg-3675	39	11	pc	pc	NOUN
fuelectenerg-3675	39	12	based	base	VERB
fuelectenerg-3675	39	13	measurement	measurement	NOUN
fuelectenerg-3675	39	14	setup	setup	NOUN
fuelectenerg-3675	39	15	.	.	PUNCT
fuelectenerg-3675	40	1	the	the	DET
fuelectenerg-3675	40	2	hall	hall	NOUN
fuelectenerg-3675	40	3	sensor	sensor	NOUN
fuelectenerg-3675	40	4	has	have	AUX
fuelectenerg-3675	40	5	been	be	AUX
fuelectenerg-3675	40	6	used	use	VERB
fuelectenerg-3675	40	7	for	for	ADP
fuelectenerg-3675	40	8	measurement	measurement	NOUN
fuelectenerg-3675	40	9	of	of	ADP
fuelectenerg-3675	40	10	the	the	DET
fuelectenerg-3675	40	11	magnetic	magnetic	PROPN
fuelectenerg-3675	40	12	flux	flux	NOUN
fuelectenerg-3675	40	13	density	density	NOUN
fuelectenerg-3675	40	14	in	in	ADP
fuelectenerg-3675	40	15	a	a	DET
fuelectenerg-3675	40	16	homogeneity	homogeneity	NOUN
fuelectenerg-3675	40	17	zone	zone	NOUN
fuelectenerg-3675	40	18	of	of	ADP
fuelectenerg-3675	40	19	the	the	DET
fuelectenerg-3675	40	20	large	large	ADJ
fuelectenerg-3675	40	21	solenoid	solenoid	NOUN
fuelectenerg-3675	40	22	.	.	PUNCT
fuelectenerg-3675	41	1	voltage	voltage	NOUN
fuelectenerg-3675	41	2	supplied	supply	VERB
fuelectenerg-3675	41	3	and	and	CCONJ
fuelectenerg-3675	41	4	electric	electric	ADJ
fuelectenerg-3675	41	5	current	current	NOUN
fuelectenerg-3675	41	6	of	of	ADP
fuelectenerg-3675	41	7	large	large	ADJ
fuelectenerg-3675	41	8	solenoid	solenoid	NOUN
fuelectenerg-3675	41	9	have	have	AUX
fuelectenerg-3675	41	10	been	be	AUX
fuelectenerg-3675	41	11	also	also	ADV
fuelectenerg-3675	41	12	measured	measure	VERB
fuelectenerg-3675	41	13	.	.	PUNCT
fuelectenerg-3675	42	1	five	five	NUM
fuelectenerg-3675	42	2	voltages	voltage	NOUN
fuelectenerg-3675	42	3	from	from	ADP
fuelectenerg-3675	42	4	the	the	DET
fuelectenerg-3675	42	5	system	system	NOUN
fuelectenerg-3675	42	6	of	of	ADP
fuelectenerg-3675	42	7	pickup	pickup	ADJ
fuelectenerg-3675	42	8	coils	coil	NOUN
fuelectenerg-3675	42	9	have	have	AUX
fuelectenerg-3675	42	10	been	be	AUX
fuelectenerg-3675	42	11	measured	measure	VERB
fuelectenerg-3675	42	12	:	:	PUNCT
fuelectenerg-3675	42	13	one	one	NUM
fuelectenerg-3675	42	14	on	on	ADP
fuelectenerg-3675	42	15	the	the	DET
fuelectenerg-3675	42	16	empty	empty	ADJ
fuelectenerg-3675	42	17	coil	coil	NOUN
fuelectenerg-3675	42	18	,	,	PUNCT
fuelectenerg-3675	42	19	two	two	NUM
fuelectenerg-3675	42	20	on	on	ADP
fuelectenerg-3675	42	21	coils	coil	NOUN
fuelectenerg-3675	42	22	in	in	ADP
fuelectenerg-3675	42	23	the	the	DET
fuelectenerg-3675	42	24	opposition	opposition	NOUN
fuelectenerg-3675	42	25	and	and	CCONJ
fuelectenerg-3675	42	26	two	two	NUM
fuelectenerg-3675	42	27	compensated	compensated	ADJ
fuelectenerg-3675	42	28	voltages	voltage	NOUN
fuelectenerg-3675	42	29	.	.	PUNCT
fuelectenerg-3675	43	1	measurements	measurement	NOUN
fuelectenerg-3675	43	2	have	have	AUX
fuelectenerg-3675	43	3	been	be	AUX
fuelectenerg-3675	43	4	performed	perform	VERB
fuelectenerg-3675	43	5	using	use	VERB
fuelectenerg-3675	43	6	ni	ni	PROPN
fuelectenerg-3675	43	7	usb	usb	PROPN
fuelectenerg-3675	43	8	6009	6009	NUM
fuelectenerg-3675	43	9	data	datum	NOUN
fuelectenerg-3675	43	10	acquisition	acquisition	NOUN
fuelectenerg-3675	43	11	card	card	NOUN
fuelectenerg-3675	43	12	and	and	CCONJ
fuelectenerg-3675	43	13	application	application	NOUN
fuelectenerg-3675	43	14	created	create	VERB
fuelectenerg-3675	43	15	in	in	ADP
fuelectenerg-3675	43	16	labview	labview	NOUN
fuelectenerg-3675	43	17	software	software	NOUN
fuelectenerg-3675	43	18	.	.	PUNCT
fuelectenerg-3675	44	1	a	a	DET
fuelectenerg-3675	44	2	ratio	ratio	NOUN
fuelectenerg-3675	44	3	of	of	ADP
fuelectenerg-3675	44	4	the	the	DET
fuelectenerg-3675	44	5	magnetic	magnetic	PROPN
fuelectenerg-3675	44	6	flux	flux	PROPN
fuelectenerg-3675	44	7	density	density	PROPN
fuelectenerg-3675	44	8	maximum	maximum	NOUN
fuelectenerg-3675	44	9	and	and	CCONJ
fuelectenerg-3675	44	10	the	the	DET
fuelectenerg-3675	44	11	electric	electric	ADJ
fuelectenerg-3675	44	12	current	current	ADJ
fuelectenerg-3675	44	13	maximum	maximum	NOUN
fuelectenerg-3675	44	14	gives	give	VERB
fuelectenerg-3675	44	15	a	a	DET
fuelectenerg-3675	44	16	calibration	calibration	NOUN
fuelectenerg-3675	44	17	constant	constant	ADJ
fuelectenerg-3675	44	18	of	of	ADP
fuelectenerg-3675	44	19	the	the	DET
fuelectenerg-3675	44	20	large	large	ADJ
fuelectenerg-3675	44	21	solenoid	solenoid	NOUN
fuelectenerg-3675	44	22	.	.	PUNCT
fuelectenerg-3675	45	1	a	a	DET
fuelectenerg-3675	45	2	calibration	calibration	NOUN
fuelectenerg-3675	45	3	constant	constant	ADJ
fuelectenerg-3675	45	4	of	of	ADP
fuelectenerg-3675	45	5	each	each	DET
fuelectenerg-3675	45	6	pickup	pickup	NOUN
fuelectenerg-3675	45	7	coil	coil	NOUN
fuelectenerg-3675	45	8	has	have	AUX
fuelectenerg-3675	45	9	been	be	AUX
fuelectenerg-3675	45	10	calculated	calculate	VERB
fuelectenerg-3675	45	11	from	from	ADP
fuelectenerg-3675	45	12	the	the	DET
fuelectenerg-3675	45	13	corresponding	correspond	VERB
fuelectenerg-3675	45	14	voltage	voltage	NOUN
fuelectenerg-3675	45	15	maximum	maximum	NOUN
fuelectenerg-3675	45	16	.	.	PUNCT
fuelectenerg-3675	46	1	this	this	DET
fuelectenerg-3675	46	2	paper	paper	NOUN
fuelectenerg-3675	46	3	gives	give	VERB
fuelectenerg-3675	46	4	a	a	DET
fuelectenerg-3675	46	5	detailed	detailed	ADJ
fuelectenerg-3675	46	6	description	description	NOUN
fuelectenerg-3675	46	7	of	of	ADP
fuelectenerg-3675	46	8	ac	ac	PROPN
fuelectenerg-3675	46	9	induction	induction	NOUN
fuelectenerg-3675	46	10	magnetometer	magnetometer	NOUN
fuelectenerg-3675	46	11	,	,	PUNCT
fuelectenerg-3675	46	12	all	all	DET
fuelectenerg-3675	46	13	information	information	NOUN
fuelectenerg-3675	46	14	on	on	ADP
fuelectenerg-3675	46	15	the	the	DET
fuelectenerg-3675	46	16	measuring	measure	VERB
fuelectenerg-3675	46	17	equipment	equipment	NOUN
fuelectenerg-3675	46	18	and	and	CCONJ
fuelectenerg-3675	46	19	calibration	calibration	NOUN
fuelectenerg-3675	46	20	procedure	procedure	NOUN
fuelectenerg-3675	46	21	,	,	PUNCT
fuelectenerg-3675	46	22	as	as	ADV
fuelectenerg-3675	46	23	well	well	ADV
fuelectenerg-3675	46	24	as	as	ADP
fuelectenerg-3675	46	25	the	the	DET
fuelectenerg-3675	46	26	results	result	NOUN
fuelectenerg-3675	46	27	obtained	obtain	VERB
fuelectenerg-3675	46	28	during	during	ADP
fuelectenerg-3675	46	29	the	the	DET
fuelectenerg-3675	46	30	calibration	calibration	NOUN
fuelectenerg-3675	46	31	.	.	PUNCT
fuelectenerg-3675	47	1	it	it	PRON
fuelectenerg-3675	47	2	also	also	ADV
fuelectenerg-3675	47	3	gives	give	VERB
fuelectenerg-3675	47	4	a	a	DET
fuelectenerg-3675	47	5	detailed	detailed	ADJ
fuelectenerg-3675	47	6	calculation	calculation	NOUN
fuelectenerg-3675	47	7	of	of	ADP
fuelectenerg-3675	47	8	the	the	DET
fuelectenerg-3675	47	9	measurement	measurement	NOUN
fuelectenerg-3675	47	10	uncertainty	uncertainty	NOUN
fuelectenerg-3675	47	11	,	,	PUNCT
fuelectenerg-3675	47	12	as	as	ADV
fuelectenerg-3675	47	13	well	well	ADV
fuelectenerg-3675	47	14	as	as	ADP
fuelectenerg-3675	47	15	a	a	DET
fuelectenerg-3675	47	16	discussion	discussion	NOUN
fuelectenerg-3675	47	17	of	of	ADP
fuelectenerg-3675	47	18	the	the	DET
fuelectenerg-3675	47	19	results	result	NOUN
fuelectenerg-3675	47	20	obtained	obtain	VERB
fuelectenerg-3675	47	21	,	,	PUNCT
fuelectenerg-3675	47	22	and	and	CCONJ
fuelectenerg-3675	47	23	explains	explain	VERB
fuelectenerg-3675	47	24	how	how	SCONJ
fuelectenerg-3675	47	25	to	to	PART
fuelectenerg-3675	47	26	calculate	calculate	VERB
fuelectenerg-3675	47	27	the	the	DET
fuelectenerg-3675	47	28	magnetic	magnetic	ADJ
fuelectenerg-3675	47	29	field	field	NOUN
fuelectenerg-3675	47	30	,	,	PUNCT
fuelectenerg-3675	47	31	the	the	DET
fuelectenerg-3675	47	32	magnetic	magnetic	ADJ
fuelectenerg-3675	47	33	flux	flux	NOUN
fuelectenerg-3675	47	34	density	density	NOUN
fuelectenerg-3675	47	35	and	and	CCONJ
fuelectenerg-3675	47	36	the	the	DET
fuelectenerg-3675	47	37	magnetisation	magnetisation	NOUN
fuelectenerg-3675	47	38	using	use	VERB
fuelectenerg-3675	47	39	obtained	obtain	VERB
fuelectenerg-3675	47	40	calibration	calibration	NOUN
fuelectenerg-3675	47	41	constants	constant	NOUN
fuelectenerg-3675	47	42	.	.	PUNCT
fuelectenerg-3675	48	1	moreover	moreover	ADV
fuelectenerg-3675	48	2	,	,	PUNCT
fuelectenerg-3675	48	3	some	some	DET
fuelectenerg-3675	48	4	practical	practical	ADJ
fuelectenerg-3675	48	5	comments	comment	NOUN
fuelectenerg-3675	48	6	on	on	ADP
fuelectenerg-3675	48	7	measurements	measurement	NOUN
fuelectenerg-3675	48	8	at	at	ADP
fuelectenerg-3675	48	9	various	various	ADJ
fuelectenerg-3675	48	10	frequencies	frequency	NOUN
fuelectenerg-3675	48	11	of	of	ADP
fuelectenerg-3675	48	12	the	the	DET
fuelectenerg-3675	48	13	magnetising	magnetising	NOUN
fuelectenerg-3675	48	14	current	current	NOUN
fuelectenerg-3675	48	15	are	be	AUX
fuelectenerg-3675	48	16	given	give	VERB
fuelectenerg-3675	48	17	in	in	ADP
fuelectenerg-3675	48	18	the	the	DET
fuelectenerg-3675	48	19	paper	paper	NOUN
fuelectenerg-3675	48	20	.	.	PUNCT
fuelectenerg-3675	49	1	calibration	calibration	NOUN
fuelectenerg-3675	49	2	of	of	ADP
fuelectenerg-3675	49	3	ac	ac	PROPN
fuelectenerg-3675	49	4	induction	induction	NOUN
fuelectenerg-3675	49	5	magnetometer	magnetometer	NOUN
fuelectenerg-3675	49	6	615	615	NUM
fuelectenerg-3675	49	7	2	2	NUM
fuelectenerg-3675	49	8	.	.	PUNCT
fuelectenerg-3675	50	1	ac	ac	PROPN
fuelectenerg-3675	50	2	induction	induction	NOUN
fuelectenerg-3675	50	3	magnetometer	magnetometer	NOUN
fuelectenerg-3675	50	4	a	a	DET
fuelectenerg-3675	50	5	photo	photo	NOUN
fuelectenerg-3675	50	6	of	of	ADP
fuelectenerg-3675	50	7	the	the	DET
fuelectenerg-3675	50	8	ac	ac	PROPN
fuelectenerg-3675	50	9	induction	induction	NOUN
fuelectenerg-3675	50	10	magnetometer	magnetometer	NOUN
fuelectenerg-3675	50	11	is	be	AUX
fuelectenerg-3675	50	12	given	give	VERB
fuelectenerg-3675	50	13	in	in	ADP
fuelectenerg-3675	50	14	fig	fig	NOUN
fuelectenerg-3675	50	15	.	.	PUNCT
fuelectenerg-3675	51	1	1	1	X
fuelectenerg-3675	51	2	.	.	X
fuelectenerg-3675	52	1	it	it	PRON
fuelectenerg-3675	52	2	was	be	AUX
fuelectenerg-3675	52	3	a	a	DET
fuelectenerg-3675	52	4	part	part	NOUN
fuelectenerg-3675	52	5	of	of	ADP
fuelectenerg-3675	52	6	equipment	equipment	NOUN
fuelectenerg-3675	52	7	of	of	ADP
fuelectenerg-3675	52	8	ferrotester	ferrotester	NOUN
fuelectenerg-3675	52	9	2738	2738	NUM
fuelectenerg-3675	52	10	/	/	SYM
fuelectenerg-3675	52	11	s-3	s-3	NOUN
fuelectenerg-3675	52	12	.	.	PUNCT
fuelectenerg-3675	53	1	it	it	PRON
fuelectenerg-3675	53	2	has	have	VERB
fuelectenerg-3675	53	3	360	360	NUM
fuelectenerg-3675	53	4	mm	mm	INTJ
fuelectenerg-3675	53	5	long	long	ADJ
fuelectenerg-3675	53	6	magnetising	magnetise	VERB
fuelectenerg-3675	53	7	coil	coil	NOUN
fuelectenerg-3675	53	8	(	(	PUNCT
fuelectenerg-3675	53	9	large	large	ADJ
fuelectenerg-3675	53	10	solenoid	solenoid	NOUN
fuelectenerg-3675	53	11	)	)	PUNCT
fuelectenerg-3675	53	12	of	of	ADP
fuelectenerg-3675	53	13	inner	inner	ADJ
fuelectenerg-3675	53	14	diameter	diameter	NOUN
fuelectenerg-3675	53	15	2r0=65	2r0=65	NUM
fuelectenerg-3675	53	16	mm	mm	PROPN
fuelectenerg-3675	53	17	,	,	PUNCT
fuelectenerg-3675	53	18	fig	fig	NOUN
fuelectenerg-3675	53	19	1a	1a	NOUN
fuelectenerg-3675	53	20	.	.	PUNCT
fuelectenerg-3675	54	1	a	a	DET
fuelectenerg-3675	54	2	number	number	NOUN
fuelectenerg-3675	54	3	of	of	ADP
fuelectenerg-3675	54	4	turns	turn	NOUN
fuelectenerg-3675	54	5	is	be	AUX
fuelectenerg-3675	54	6	unknown	unknown	ADJ
fuelectenerg-3675	54	7	(	(	PUNCT
fuelectenerg-3675	54	8	it	it	PRON
fuelectenerg-3675	54	9	is	be	AUX
fuelectenerg-3675	54	10	not	not	PART
fuelectenerg-3675	54	11	given	give	VERB
fuelectenerg-3675	54	12	in	in	ADP
fuelectenerg-3675	54	13	the	the	DET
fuelectenerg-3675	54	14	user	user	NOUN
fuelectenerg-3675	54	15	manual	manual	NOUN
fuelectenerg-3675	54	16	)	)	PUNCT
fuelectenerg-3675	54	17	.	.	PUNCT
fuelectenerg-3675	55	1	it	it	PRON
fuelectenerg-3675	55	2	also	also	ADV
fuelectenerg-3675	55	3	has	have	VERB
fuelectenerg-3675	55	4	a	a	DET
fuelectenerg-3675	55	5	system	system	NOUN
fuelectenerg-3675	55	6	of	of	ADP
fuelectenerg-3675	55	7	five	five	NUM
fuelectenerg-3675	55	8	pickup	pickup	ADJ
fuelectenerg-3675	55	9	coils	coil	NOUN
fuelectenerg-3675	55	10	,	,	PUNCT
fuelectenerg-3675	55	11	each	each	DET
fuelectenerg-3675	55	12	100	100	NUM
fuelectenerg-3675	55	13	mm	mm	INTJ
fuelectenerg-3675	55	14	long	long	ADV
fuelectenerg-3675	55	15	with	with	ADP
fuelectenerg-3675	55	16	inner	inner	ADJ
fuelectenerg-3675	55	17	diameter	diameter	NOUN
fuelectenerg-3675	55	18	15	15	NUM
fuelectenerg-3675	55	19	mm	mm	NOUN
fuelectenerg-3675	55	20	,	,	PUNCT
fuelectenerg-3675	55	21	fig	fig	NOUN
fuelectenerg-3675	55	22	1b	1b	NUM
fuelectenerg-3675	55	23	.	.	PUNCT
fuelectenerg-3675	56	1	a	a	DET
fuelectenerg-3675	56	2	number	number	NOUN
fuelectenerg-3675	56	3	of	of	ADP
fuelectenerg-3675	56	4	turns	turn	NOUN
fuelectenerg-3675	56	5	is	be	AUX
fuelectenerg-3675	56	6	also	also	ADV
fuelectenerg-3675	56	7	unknown	unknown	ADJ
fuelectenerg-3675	56	8	.	.	PUNCT
fuelectenerg-3675	57	1	a	a	DET
fuelectenerg-3675	57	2	cross	cross	NOUN
fuelectenerg-3675	57	3	-	-	NOUN
fuelectenerg-3675	57	4	section	section	NOUN
fuelectenerg-3675	57	5	of	of	ADP
fuelectenerg-3675	57	6	the	the	DET
fuelectenerg-3675	57	7	magnetometer	magnetometer	NOUN
fuelectenerg-3675	57	8	is	be	AUX
fuelectenerg-3675	57	9	presented	present	VERB
fuelectenerg-3675	57	10	in	in	ADP
fuelectenerg-3675	57	11	fig	fig	NOUN
fuelectenerg-3675	57	12	.	.	PUNCT
fuelectenerg-3675	58	1	2a	2a	NUM
fuelectenerg-3675	58	2	and	and	CCONJ
fuelectenerg-3675	58	3	an	an	DET
fuelectenerg-3675	58	4	electrical	electrical	ADJ
fuelectenerg-3675	58	5	scheme	scheme	NOUN
fuelectenerg-3675	58	6	of	of	ADP
fuelectenerg-3675	58	7	connections	connection	NOUN
fuelectenerg-3675	58	8	of	of	ADP
fuelectenerg-3675	58	9	pickup	pickup	ADJ
fuelectenerg-3675	58	10	coils	coil	NOUN
fuelectenerg-3675	58	11	is	be	AUX
fuelectenerg-3675	58	12	given	give	VERB
fuelectenerg-3675	58	13	in	in	ADP
fuelectenerg-3675	58	14	fig	fig	NOUN
fuelectenerg-3675	58	15	.	.	PUNCT
fuelectenerg-3675	59	1	2b	2b	NUM
fuelectenerg-3675	59	2	.	.	PUNCT
fuelectenerg-3675	60	1	a	a	DET
fuelectenerg-3675	60	2	)	)	PUNCT
fuelectenerg-3675	60	3	b	b	NOUN
fuelectenerg-3675	60	4	)	)	PUNCT
fuelectenerg-3675	60	5	fig	fig	NOUN
fuelectenerg-3675	60	6	.	.	PUNCT
fuelectenerg-3675	61	1	1	1	NUM
fuelectenerg-3675	61	2	photos	photo	NOUN
fuelectenerg-3675	61	3	of	of	ADP
fuelectenerg-3675	61	4	the	the	DET
fuelectenerg-3675	61	5	induction	induction	NOUN
fuelectenerg-3675	61	6	magnetometer	magnetometer	NOUN
fuelectenerg-3675	61	7	:	:	PUNCT
fuelectenerg-3675	61	8	a	a	X
fuelectenerg-3675	61	9	)	)	PUNCT
fuelectenerg-3675	61	10	large	large	ADJ
fuelectenerg-3675	61	11	solenoid	solenoid	NOUN
fuelectenerg-3675	61	12	,	,	PUNCT
fuelectenerg-3675	61	13	b	b	X
fuelectenerg-3675	61	14	)	)	PUNCT
fuelectenerg-3675	61	15	pickup	pickup	NOUN
fuelectenerg-3675	61	16	coils	coil	NOUN
fuelectenerg-3675	61	17	inside	inside	ADP
fuelectenerg-3675	61	18	large	large	ADJ
fuelectenerg-3675	61	19	solenoid	solenoid	NOUN
fuelectenerg-3675	61	20	five	five	NUM
fuelectenerg-3675	61	21	pickup	pickup	NOUN
fuelectenerg-3675	61	22	coils	coil	NOUN
fuelectenerg-3675	61	23	are	be	AUX
fuelectenerg-3675	61	24	placed	place	VERB
fuelectenerg-3675	61	25	inside	inside	ADP
fuelectenerg-3675	61	26	a	a	DET
fuelectenerg-3675	61	27	large	large	ADJ
fuelectenerg-3675	61	28	solenoid	solenoid	NOUN
fuelectenerg-3675	61	29	l0	l0	PROPN
fuelectenerg-3675	61	30	in	in	ADP
fuelectenerg-3675	61	31	its	its	PRON
fuelectenerg-3675	61	32	central	central	ADJ
fuelectenerg-3675	61	33	part	part	NOUN
fuelectenerg-3675	61	34	(	(	PUNCT
fuelectenerg-3675	61	35	z(−5	z(−5	PROPN
fuelectenerg-3675	61	36	,	,	PUNCT
fuelectenerg-3675	61	37	5	5	NUM
fuelectenerg-3675	61	38	)	)	PUNCT
fuelectenerg-3675	61	39	in	in	ADP
fuelectenerg-3675	61	40	fig	fig	NOUN
fuelectenerg-3675	61	41	.	.	PUNCT
fuelectenerg-3675	62	1	3	3	NUM
fuelectenerg-3675	62	2	)	)	PUNCT
fuelectenerg-3675	62	3	at	at	ADP
fuelectenerg-3675	62	4	the	the	DET
fuelectenerg-3675	62	5	same	same	ADJ
fuelectenerg-3675	62	6	distance	distance	NOUN
fuelectenerg-3675	62	7	r1=20	r1=20	NOUN
fuelectenerg-3675	62	8	mm	mm	INTJ
fuelectenerg-3675	62	9	from	from	ADP
fuelectenerg-3675	62	10	its	its	PRON
fuelectenerg-3675	62	11	axis	axis	NOUN
fuelectenerg-3675	62	12	(	(	PUNCT
fuelectenerg-3675	62	13	x=0	x=0	NUM
fuelectenerg-3675	62	14	in	in	ADP
fuelectenerg-3675	62	15	fig	fig	NOUN
fuelectenerg-3675	62	16	.	.	PUNCT
fuelectenerg-3675	63	1	3	3	NUM
fuelectenerg-3675	63	2	)	)	PUNCT
fuelectenerg-3675	63	3	.	.	PUNCT
fuelectenerg-3675	64	1	as	as	SCONJ
fuelectenerg-3675	64	2	it	it	PRON
fuelectenerg-3675	64	3	has	have	AUX
fuelectenerg-3675	64	4	been	be	AUX
fuelectenerg-3675	64	5	presented	present	VERB
fuelectenerg-3675	64	6	in	in	ADP
fuelectenerg-3675	64	7	[	[	X
fuelectenerg-3675	64	8	1	1	NUM
fuelectenerg-3675	64	9	]	]	PUNCT
fuelectenerg-3675	64	10	,	,	PUNCT
fuelectenerg-3675	64	11	this	this	PRON
fuelectenerg-3675	64	12	is	be	AUX
fuelectenerg-3675	64	13	a	a	DET
fuelectenerg-3675	64	14	zone	zone	NOUN
fuelectenerg-3675	64	15	with	with	ADP
fuelectenerg-3675	64	16	a	a	DET
fuelectenerg-3675	64	17	homogeneous	homogeneous	ADJ
fuelectenerg-3675	64	18	magnetic	magnetic	ADJ
fuelectenerg-3675	64	19	field	field	NOUN
fuelectenerg-3675	64	20	in	in	ADP
fuelectenerg-3675	64	21	which	which	PRON
fuelectenerg-3675	64	22	the	the	DET
fuelectenerg-3675	64	23	variation	variation	NOUN
fuelectenerg-3675	64	24	of	of	ADP
fuelectenerg-3675	64	25	the	the	DET
fuelectenerg-3675	64	26	magnetic	magnetic	ADJ
fuelectenerg-3675	64	27	field	field	NOUN
fuelectenerg-3675	64	28	intensity	intensity	NOUN
fuelectenerg-3675	64	29	is	be	AUX
fuelectenerg-3675	64	30	less	less	ADJ
fuelectenerg-3675	64	31	than	than	ADP
fuelectenerg-3675	64	32	1	1	NUM
fuelectenerg-3675	64	33	%	%	NOUN
fuelectenerg-3675	64	34	of	of	ADP
fuelectenerg-3675	64	35	its	its	PRON
fuelectenerg-3675	64	36	maximum	maximum	NOUN
fuelectenerg-3675	64	37	.	.	PUNCT
fuelectenerg-3675	65	1	since	since	SCONJ
fuelectenerg-3675	65	2	whole	whole	ADJ
fuelectenerg-3675	65	3	system	system	NOUN
fuelectenerg-3675	65	4	has	have	VERB
fuelectenerg-3675	65	5	axial	axial	ADJ
fuelectenerg-3675	65	6	symmetry	symmetry	NOUN
fuelectenerg-3675	65	7	,	,	PUNCT
fuelectenerg-3675	65	8	pickup	pickup	ADJ
fuelectenerg-3675	65	9	coils	coil	NOUN
fuelectenerg-3675	65	10	are	be	AUX
fuelectenerg-3675	65	11	exposed	expose	VERB
fuelectenerg-3675	65	12	to	to	ADP
fuelectenerg-3675	65	13	the	the	DET
fuelectenerg-3675	65	14	same	same	ADJ
fuelectenerg-3675	65	15	magnetic	magnetic	ADJ
fuelectenerg-3675	65	16	field	field	NOUN
fuelectenerg-3675	65	17	.	.	PUNCT
fuelectenerg-3675	66	1	coil	coil	PROPN
fuelectenerg-3675	66	2	l1	l1	PROPN
fuelectenerg-3675	66	3	is	be	AUX
fuelectenerg-3675	66	4	used	use	VERB
fuelectenerg-3675	66	5	for	for	ADP
fuelectenerg-3675	66	6	measurement	measurement	NOUN
fuelectenerg-3675	66	7	of	of	ADP
fuelectenerg-3675	66	8	the	the	DET
fuelectenerg-3675	66	9	magnetic	magnetic	ADJ
fuelectenerg-3675	66	10	field	field	NOUN
fuelectenerg-3675	66	11	and	and	CCONJ
fuelectenerg-3675	66	12	its	its	PRON
fuelectenerg-3675	66	13	interior	interior	NOUN
fuelectenerg-3675	66	14	should	should	AUX
fuelectenerg-3675	66	15	not	not	PART
fuelectenerg-3675	66	16	contain	contain	VERB
fuelectenerg-3675	66	17	samples	sample	NOUN
fuelectenerg-3675	66	18	of	of	ADP
fuelectenerg-3675	66	19	ferromagnetic	ferromagnetic	ADJ
fuelectenerg-3675	66	20	material	material	NOUN
fuelectenerg-3675	66	21	.	.	PUNCT
fuelectenerg-3675	67	1	coils	coil	NOUN
fuelectenerg-3675	67	2	l2	l2	NOUN
fuelectenerg-3675	67	3	and	and	CCONJ
fuelectenerg-3675	67	4	l′2	l′2	NOUN
fuelectenerg-3675	67	5	are	be	AUX
fuelectenerg-3675	67	6	two	two	NUM
fuelectenerg-3675	67	7	identical	identical	ADJ
fuelectenerg-3675	67	8	coils	coil	NOUN
fuelectenerg-3675	67	9	wound	wound	NOUN
fuelectenerg-3675	67	10	in	in	ADP
fuelectenerg-3675	67	11	the	the	DET
fuelectenerg-3675	67	12	opposite	opposite	ADJ
fuelectenerg-3675	67	13	direction	direction	NOUN
fuelectenerg-3675	67	14	and	and	CCONJ
fuelectenerg-3675	67	15	connected	connect	VERB
fuelectenerg-3675	67	16	in	in	ADP
fuelectenerg-3675	67	17	mutual	mutual	ADJ
fuelectenerg-3675	67	18	opposition	opposition	NOUN
fuelectenerg-3675	67	19	,	,	PUNCT
fuelectenerg-3675	67	20	as	as	SCONJ
fuelectenerg-3675	67	21	it	it	PRON
fuelectenerg-3675	67	22	is	be	AUX
fuelectenerg-3675	67	23	given	give	VERB
fuelectenerg-3675	67	24	in	in	ADP
fuelectenerg-3675	67	25	fig	fig	NOUN
fuelectenerg-3675	67	26	.	.	PUNCT
fuelectenerg-3675	68	1	2b	2b	NOUN
fuelectenerg-3675	68	2	.	.	PUNCT
fuelectenerg-3675	69	1	coils	coil	NOUN
fuelectenerg-3675	69	2	l3	l3	PROPN
fuelectenerg-3675	69	3	and	and	CCONJ
fuelectenerg-3675	69	4	l′3	l′3	PROPN
fuelectenerg-3675	69	5	are	be	AUX
fuelectenerg-3675	69	6	identical	identical	ADJ
fuelectenerg-3675	69	7	,	,	PUNCT
fuelectenerg-3675	69	8	wound	wound	VERB
fuelectenerg-3675	69	9	in	in	ADP
fuelectenerg-3675	69	10	the	the	DET
fuelectenerg-3675	69	11	opposite	opposite	ADJ
fuelectenerg-3675	69	12	direction	direction	NOUN
fuelectenerg-3675	69	13	,	,	PUNCT
fuelectenerg-3675	69	14	and	and	CCONJ
fuelectenerg-3675	69	15	connected	connect	VERB
fuelectenerg-3675	69	16	in	in	ADP
fuelectenerg-3675	69	17	mutual	mutual	ADJ
fuelectenerg-3675	69	18	opposition	opposition	NOUN
fuelectenerg-3675	69	19	(	(	PUNCT
fuelectenerg-3675	69	20	fig	fig	NOUN
fuelectenerg-3675	69	21	.	.	PUNCT
fuelectenerg-3675	69	22	2b	2b	NUM
fuelectenerg-3675	69	23	)	)	PUNCT
fuelectenerg-3675	69	24	.	.	PUNCT
fuelectenerg-3675	70	1	a	a	DET
fuelectenerg-3675	70	2	small	small	ADJ
fuelectenerg-3675	70	3	difference	difference	NOUN
fuelectenerg-3675	70	4	between	between	ADP
fuelectenerg-3675	70	5	coil	coil	NOUN
fuelectenerg-3675	70	6	systems	system	NOUN
fuelectenerg-3675	70	7	2	2	NUM
fuelectenerg-3675	70	8	and	and	CCONJ
fuelectenerg-3675	70	9	3	3	NUM
fuelectenerg-3675	70	10	has	have	AUX
fuelectenerg-3675	70	11	been	be	AUX
fuelectenerg-3675	70	12	observed	observe	VERB
fuelectenerg-3675	70	13	.	.	PUNCT
fuelectenerg-3675	71	1	a	a	DET
fuelectenerg-3675	71	2	sample	sample	NOUN
fuelectenerg-3675	71	3	of	of	ADP
fuelectenerg-3675	71	4	ferromagnetic	ferromagnetic	ADJ
fuelectenerg-3675	71	5	material	material	NOUN
fuelectenerg-3675	71	6	under	under	ADP
fuelectenerg-3675	71	7	test	test	NOUN
fuelectenerg-3675	71	8	can	can	AUX
fuelectenerg-3675	71	9	be	be	AUX
fuelectenerg-3675	71	10	placed	place	VERB
fuelectenerg-3675	71	11	in	in	ADP
fuelectenerg-3675	71	12	any	any	PRON
fuelectenerg-3675	71	13	of	of	ADP
fuelectenerg-3675	71	14	these	these	DET
fuelectenerg-3675	71	15	616	616	NUM
fuelectenerg-3675	71	16	b.	b.	PROPN
fuelectenerg-3675	71	17	koprivica	koprivica	PROPN
fuelectenerg-3675	71	18	,	,	PUNCT
fuelectenerg-3675	71	19	m.	m.	NOUN
fuelectenerg-3675	71	20	šućurović	šućurović	PROPN
fuelectenerg-3675	71	21	,	,	PUNCT
fuelectenerg-3675	71	22	a.	a.	NOUN
fuelectenerg-3675	71	23	milovanović	milovanović	NOUN
fuelectenerg-3675	71	24	four	four	NUM
fuelectenerg-3675	71	25	pickup	pickup	NOUN
fuelectenerg-3675	71	26	coils	coil	NOUN
fuelectenerg-3675	71	27	and	and	CCONJ
fuelectenerg-3675	71	28	the	the	DET
fuelectenerg-3675	71	29	magnetic	magnetic	PROPN
fuelectenerg-3675	71	30	flux	flux	NOUN
fuelectenerg-3675	71	31	density	density	NOUN
fuelectenerg-3675	71	32	can	can	AUX
fuelectenerg-3675	71	33	be	be	AUX
fuelectenerg-3675	71	34	measured	measure	VERB
fuelectenerg-3675	71	35	.	.	PUNCT
fuelectenerg-3675	72	1	a	a	DET
fuelectenerg-3675	72	2	resistor	resistor	NOUN
fuelectenerg-3675	72	3	(	(	PUNCT
fuelectenerg-3675	72	4	45	45	NUM
fuelectenerg-3675	72	5	kω	kω	NOUN
fuelectenerg-3675	72	6	)	)	PUNCT
fuelectenerg-3675	72	7	is	be	AUX
fuelectenerg-3675	72	8	connected	connect	VERB
fuelectenerg-3675	72	9	in	in	ADP
fuelectenerg-3675	72	10	series	series	NOUN
fuelectenerg-3675	72	11	with	with	ADP
fuelectenerg-3675	72	12	two	two	NUM
fuelectenerg-3675	72	13	coils	coil	NOUN
fuelectenerg-3675	72	14	in	in	ADP
fuelectenerg-3675	72	15	opposition	opposition	NOUN
fuelectenerg-3675	72	16	to	to	PART
fuelectenerg-3675	72	17	reduce	reduce	VERB
fuelectenerg-3675	72	18	the	the	DET
fuelectenerg-3675	72	19	electric	electric	ADJ
fuelectenerg-3675	72	20	current	current	NOUN
fuelectenerg-3675	72	21	in	in	ADP
fuelectenerg-3675	72	22	the	the	DET
fuelectenerg-3675	72	23	coils	coil	NOUN
fuelectenerg-3675	72	24	,	,	PUNCT
fuelectenerg-3675	72	25	fig	fig	NOUN
fuelectenerg-3675	72	26	.	.	PUNCT
fuelectenerg-3675	73	1	2b	2b	NOUN
fuelectenerg-3675	73	2	.	.	PUNCT
fuelectenerg-3675	74	1	0l	0l	NUM
fuelectenerg-3675	74	2	1l	1l	NUM
fuelectenerg-3675	74	3	2l	2l	NOUN
fuelectenerg-3675	74	4	'	'	PART
fuelectenerg-3675	74	5	2l	2l	PROPN
fuelectenerg-3675	74	6	'	'	PART
fuelectenerg-3675	74	7	3l	3l	NUM
fuelectenerg-3675	74	8	3l	3l	NUM
fuelectenerg-3675	74	9	0r	0r	X
fuelectenerg-3675	74	10	1r	1r	NUM
fuelectenerg-3675	74	11	hs	hs	PROPN
fuelectenerg-3675	74	12	1l	1l	PROPN
fuelectenerg-3675	74	13	'	'	PART
fuelectenerg-3675	74	14	2l2l	2l2l	NOUN
fuelectenerg-3675	74	15	'	'	PART
fuelectenerg-3675	74	16	3l	3l	NUM
fuelectenerg-3675	74	17	3l	3l	NUM
fuelectenerg-3675	74	18	k45	k45	ADP
fuelectenerg-3675	74	19	4	4	NUM
fuelectenerg-3675	74	20	12	12	NUM
fuelectenerg-3675	74	21	3	3	NUM
fuelectenerg-3675	74	22	k45	k45	ADP
fuelectenerg-3675	74	23	1′2′	1′2′	NUM
fuelectenerg-3675	74	24	a	a	PRON
fuelectenerg-3675	74	25	)	)	PUNCT
fuelectenerg-3675	74	26	b	b	NOUN
fuelectenerg-3675	74	27	)	)	PUNCT
fuelectenerg-3675	74	28	fig	fig	NOUN
fuelectenerg-3675	74	29	.	.	PUNCT
fuelectenerg-3675	75	1	2	2	NUM
fuelectenerg-3675	75	2	induction	induction	NOUN
fuelectenerg-3675	75	3	magnetometer	magnetometer	NOUN
fuelectenerg-3675	75	4	:	:	PUNCT
fuelectenerg-3675	75	5	a	a	X
fuelectenerg-3675	75	6	)	)	PUNCT
fuelectenerg-3675	75	7	cross	cross	NOUN
fuelectenerg-3675	75	8	-	-	NOUN
fuelectenerg-3675	75	9	section	section	ADJ
fuelectenerg-3675	75	10	,	,	PUNCT
fuelectenerg-3675	75	11	b	b	X
fuelectenerg-3675	75	12	)	)	PUNCT
fuelectenerg-3675	75	13	electrical	electrical	ADJ
fuelectenerg-3675	75	14	scheme	scheme	NOUN
fuelectenerg-3675	75	15	of	of	ADP
fuelectenerg-3675	75	16	connections	connection	NOUN
fuelectenerg-3675	75	17	of	of	ADP
fuelectenerg-3675	75	18	pickup	pickup	ADJ
fuelectenerg-3675	75	19	coils	coil	NOUN
fuelectenerg-3675	75	20	fig	fig	NOUN
fuelectenerg-3675	75	21	.	.	PUNCT
fuelectenerg-3675	76	1	3	3	NUM
fuelectenerg-3675	76	2	total	total	PROPN
fuelectenerg-3675	76	3	magnetic	magnetic	ADJ
fuelectenerg-3675	76	4	flux	flux	NOUN
fuelectenerg-3675	76	5	density	density	NOUN
fuelectenerg-3675	76	6	distribution	distribution	NOUN
fuelectenerg-3675	76	7	inside	inside	ADP
fuelectenerg-3675	76	8	large	large	ADJ
fuelectenerg-3675	76	9	solenoid	solenoid	ADJ
fuelectenerg-3675	76	10	fig	fig	NOUN
fuelectenerg-3675	76	11	.	.	PUNCT
fuelectenerg-3675	77	1	2a	2a	PROPN
fuelectenerg-3675	77	2	also	also	ADV
fuelectenerg-3675	77	3	shows	show	VERB
fuelectenerg-3675	77	4	a	a	DET
fuelectenerg-3675	77	5	position	position	NOUN
fuelectenerg-3675	77	6	of	of	ADP
fuelectenerg-3675	77	7	hall	hall	NOUN
fuelectenerg-3675	77	8	sensor	sensor	PROPN
fuelectenerg-3675	77	9	(	(	PUNCT
fuelectenerg-3675	77	10	hs	hs	X
fuelectenerg-3675	77	11	)	)	PUNCT
fuelectenerg-3675	77	12	used	use	VERB
fuelectenerg-3675	77	13	for	for	ADP
fuelectenerg-3675	77	14	direct	direct	ADJ
fuelectenerg-3675	77	15	measurement	measurement	NOUN
fuelectenerg-3675	77	16	of	of	ADP
fuelectenerg-3675	77	17	the	the	DET
fuelectenerg-3675	77	18	magnetic	magnetic	PROPN
fuelectenerg-3675	77	19	flux	flux	NOUN
fuelectenerg-3675	77	20	density	density	NOUN
fuelectenerg-3675	77	21	inside	inside	ADP
fuelectenerg-3675	77	22	large	large	ADJ
fuelectenerg-3675	77	23	solenoid	solenoid	NOUN
fuelectenerg-3675	77	24	.	.	PUNCT
fuelectenerg-3675	78	1	this	this	DET
fuelectenerg-3675	78	2	sensor	sensor	NOUN
fuelectenerg-3675	78	3	(	(	PUNCT
fuelectenerg-3675	78	4	type	type	NOUN
fuelectenerg-3675	78	5	ss49e	ss49e	NOUN
fuelectenerg-3675	78	6	)	)	PUNCT
fuelectenerg-3675	78	7	is	be	AUX
fuelectenerg-3675	78	8	inserted	insert	VERB
fuelectenerg-3675	78	9	in	in	ADP
fuelectenerg-3675	78	10	the	the	DET
fuelectenerg-3675	78	11	vertical	vertical	ADJ
fuelectenerg-3675	78	12	gap	gap	NOUN
fuelectenerg-3675	78	13	of	of	ADP
fuelectenerg-3675	78	14	the	the	DET
fuelectenerg-3675	78	15	cylindrical	cylindrical	ADJ
fuelectenerg-3675	78	16	plastic	plastic	NOUN
fuelectenerg-3675	78	17	holder	holder	NOUN
fuelectenerg-3675	78	18	(	(	PUNCT
fuelectenerg-3675	78	19	perpendicular	perpendicular	ADJ
fuelectenerg-3675	78	20	to	to	ADP
fuelectenerg-3675	78	21	its	its	PRON
fuelectenerg-3675	78	22	axis	axis	NOUN
fuelectenerg-3675	78	23	)	)	PUNCT
fuelectenerg-3675	78	24	.	.	PUNCT
fuelectenerg-3675	79	1	along	along	ADP
fuelectenerg-3675	79	2	with	with	ADP
fuelectenerg-3675	79	3	holder	holder	NOUN
fuelectenerg-3675	79	4	,	,	PUNCT
fuelectenerg-3675	79	5	the	the	DET
fuelectenerg-3675	79	6	sensor	sensor	NOUN
fuelectenerg-3675	79	7	is	be	AUX
fuelectenerg-3675	79	8	placed	place	VERB
fuelectenerg-3675	79	9	inside	inside	ADP
fuelectenerg-3675	79	10	the	the	DET
fuelectenerg-3675	79	11	coil	coil	NOUN
fuelectenerg-3675	79	12	l1	l1	PROPN
fuelectenerg-3675	79	13	in	in	ADP
fuelectenerg-3675	79	14	the	the	DET
fuelectenerg-3675	79	15	middle	middle	NOUN
fuelectenerg-3675	79	16	of	of	ADP
fuelectenerg-3675	79	17	its	its	PRON
fuelectenerg-3675	79	18	length	length	NOUN
fuelectenerg-3675	79	19	,	,	PUNCT
fuelectenerg-3675	79	20	perpendicular	perpendicular	ADJ
fuelectenerg-3675	79	21	to	to	ADP
fuelectenerg-3675	79	22	the	the	DET
fuelectenerg-3675	79	23	calibration	calibration	NOUN
fuelectenerg-3675	79	24	of	of	ADP
fuelectenerg-3675	79	25	ac	ac	PROPN
fuelectenerg-3675	79	26	induction	induction	PROPN
fuelectenerg-3675	79	27	magnetometer	magnetometer	NOUN
fuelectenerg-3675	79	28	617	617	NUM
fuelectenerg-3675	79	29	longitudinal	longitudinal	ADJ
fuelectenerg-3675	79	30	axis	axis	NOUN
fuelectenerg-3675	79	31	of	of	ADP
fuelectenerg-3675	79	32	the	the	DET
fuelectenerg-3675	79	33	coil	coil	NOUN
fuelectenerg-3675	79	34	and	and	CCONJ
fuelectenerg-3675	79	35	perpendicular	perpendicular	NOUN
fuelectenerg-3675	79	36	to	to	ADP
fuelectenerg-3675	79	37	the	the	DET
fuelectenerg-3675	79	38	magnetic	magnetic	ADJ
fuelectenerg-3675	79	39	field	field	NOUN
fuelectenerg-3675	79	40	.	.	PUNCT
fuelectenerg-3675	80	1	a	a	DET
fuelectenerg-3675	80	2	photo	photo	NOUN
fuelectenerg-3675	80	3	of	of	ADP
fuelectenerg-3675	80	4	the	the	DET
fuelectenerg-3675	80	5	sensor	sensor	NOUN
fuelectenerg-3675	80	6	and	and	CCONJ
fuelectenerg-3675	80	7	3d	3d	NUM
fuelectenerg-3675	80	8	printed	print	VERB
fuelectenerg-3675	80	9	plastic	plastic	NOUN
fuelectenerg-3675	80	10	holder	holder	NOUN
fuelectenerg-3675	80	11	are	be	AUX
fuelectenerg-3675	80	12	presented	present	VERB
fuelectenerg-3675	80	13	in	in	ADP
fuelectenerg-3675	80	14	fig	fig	NOUN
fuelectenerg-3675	80	15	.	.	PUNCT
fuelectenerg-3675	81	1	4	4	X
fuelectenerg-3675	81	2	.	.	X
fuelectenerg-3675	81	3	fig	fig	NOUN
fuelectenerg-3675	81	4	.	.	PUNCT
fuelectenerg-3675	82	1	4	4	NUM
fuelectenerg-3675	82	2	hall	hall	NOUN
fuelectenerg-3675	82	3	sensor	sensor	NOUN
fuelectenerg-3675	82	4	and	and	CCONJ
fuelectenerg-3675	82	5	its	its	PRON
fuelectenerg-3675	82	6	position	position	NOUN
fuelectenerg-3675	82	7	inside	inside	ADP
fuelectenerg-3675	82	8	plastic	plastic	NOUN
fuelectenerg-3675	82	9	holder	holder	NOUN
fuelectenerg-3675	82	10	usually	usually	ADV
fuelectenerg-3675	82	11	,	,	PUNCT
fuelectenerg-3675	82	12	the	the	DET
fuelectenerg-3675	82	13	magnetic	magnetic	ADJ
fuelectenerg-3675	82	14	field	field	NOUN
fuelectenerg-3675	82	15	h	h	NOUN
fuelectenerg-3675	82	16	generated	generate	VERB
fuelectenerg-3675	82	17	by	by	ADP
fuelectenerg-3675	82	18	a	a	DET
fuelectenerg-3675	82	19	long	long	ADJ
fuelectenerg-3675	82	20	solenoid	solenoid	NOUN
fuelectenerg-3675	82	21	is	be	AUX
fuelectenerg-3675	82	22	calculated	calculate	VERB
fuelectenerg-3675	82	23	from	from	ADP
fuelectenerg-3675	82	24	the	the	DET
fuelectenerg-3675	82	25	measured	measure	VERB
fuelectenerg-3675	82	26	electric	electric	ADJ
fuelectenerg-3675	82	27	current	current	NOUN
fuelectenerg-3675	82	28	i	i	PRON
fuelectenerg-3675	82	29	using	use	VERB
fuelectenerg-3675	82	30	expression	expression	NOUN
fuelectenerg-3675	82	31	(	(	PUNCT
fuelectenerg-3675	82	32	1	1	NUM
fuelectenerg-3675	82	33	)	)	PUNCT
fuelectenerg-3675	83	1	[	[	X
fuelectenerg-3675	83	2	5	5	NUM
fuelectenerg-3675	83	3	]	]	PUNCT
fuelectenerg-3675	83	4	,	,	PUNCT
fuelectenerg-3675	83	5	according	accord	VERB
fuelectenerg-3675	83	6	to	to	ADP
fuelectenerg-3675	83	7	ampere	ampere	PROPN
fuelectenerg-3675	83	8	’s	’s	PART
fuelectenerg-3675	83	9	law	law	NOUN
fuelectenerg-3675	83	10	:	:	PUNCT
fuelectenerg-3675	83	11	n	n	CCONJ
fuelectenerg-3675	83	12	n	n	CCONJ
fuelectenerg-3675	84	1	u	u	NOUN
fuelectenerg-3675	84	2	h	h	NOUN
fuelectenerg-3675	85	1	i	i	NOUN
fuelectenerg-3675	85	2	l	l	NOUN
fuelectenerg-3675	85	3	l	l	NOUN
fuelectenerg-3675	86	1	r	r	NOUN
fuelectenerg-3675	87	1			NOUN
fuelectenerg-3675	87	2			NOUN
fuelectenerg-3675	87	3	,	,	PUNCT
fuelectenerg-3675	87	4	(	(	PUNCT
fuelectenerg-3675	87	5	1	1	X
fuelectenerg-3675	87	6	)	)	PUNCT
fuelectenerg-3675	87	7	where	where	SCONJ
fuelectenerg-3675	87	8	n	n	PRON
fuelectenerg-3675	87	9	is	be	AUX
fuelectenerg-3675	87	10	the	the	DET
fuelectenerg-3675	87	11	number	number	NOUN
fuelectenerg-3675	87	12	of	of	ADP
fuelectenerg-3675	87	13	the	the	DET
fuelectenerg-3675	87	14	turns	turn	NOUN
fuelectenerg-3675	87	15	of	of	ADP
fuelectenerg-3675	87	16	large	large	ADJ
fuelectenerg-3675	87	17	solenoid	solenoid	NOUN
fuelectenerg-3675	87	18	l0	l0	PROPN
fuelectenerg-3675	87	19	,	,	PUNCT
fuelectenerg-3675	87	20	l	l	PROPN
fuelectenerg-3675	87	21	is	be	AUX
fuelectenerg-3675	87	22	its	its	PRON
fuelectenerg-3675	87	23	length	length	NOUN
fuelectenerg-3675	87	24	,	,	PUNCT
fuelectenerg-3675	87	25	r	r	NOUN
fuelectenerg-3675	87	26	is	be	AUX
fuelectenerg-3675	87	27	the	the	DET
fuelectenerg-3675	87	28	resistor	resistor	NOUN
fuelectenerg-3675	87	29	connected	connect	VERB
fuelectenerg-3675	87	30	in	in	ADP
fuelectenerg-3675	87	31	the	the	DET
fuelectenerg-3675	87	32	series	series	NOUN
fuelectenerg-3675	87	33	with	with	ADP
fuelectenerg-3675	87	34	the	the	DET
fuelectenerg-3675	87	35	solenoid	solenoid	NOUN
fuelectenerg-3675	87	36	and	and	CCONJ
fuelectenerg-3675	87	37	u	u	NOUN
fuelectenerg-3675	87	38	is	be	AUX
fuelectenerg-3675	87	39	the	the	DET
fuelectenerg-3675	87	40	voltage	voltage	NOUN
fuelectenerg-3675	87	41	measured	measure	VERB
fuelectenerg-3675	87	42	at	at	ADP
fuelectenerg-3675	87	43	the	the	DET
fuelectenerg-3675	87	44	ends	end	NOUN
fuelectenerg-3675	87	45	of	of	ADP
fuelectenerg-3675	87	46	r.	r.	PROPN
fuelectenerg-3675	87	47	however	however	ADV
fuelectenerg-3675	87	48	,	,	PUNCT
fuelectenerg-3675	87	49	this	this	PRON
fuelectenerg-3675	87	50	can	can	AUX
fuelectenerg-3675	87	51	not	not	PART
fuelectenerg-3675	87	52	be	be	AUX
fuelectenerg-3675	87	53	used	use	VERB
fuelectenerg-3675	87	54	since	since	SCONJ
fuelectenerg-3675	87	55	n	n	NUM
fuelectenerg-3675	87	56	is	be	AUX
fuelectenerg-3675	87	57	unknown	unknown	ADJ
fuelectenerg-3675	87	58	for	for	ADP
fuelectenerg-3675	87	59	l0	l0	PROPN
fuelectenerg-3675	87	60	.	.	PUNCT
fuelectenerg-3675	88	1	in	in	ADP
fuelectenerg-3675	88	2	general	general	ADJ
fuelectenerg-3675	88	3	,	,	PUNCT
fuelectenerg-3675	88	4	the	the	DET
fuelectenerg-3675	88	5	expression	expression	NOUN
fuelectenerg-3675	88	6	(	(	PUNCT
fuelectenerg-3675	88	7	1	1	X
fuelectenerg-3675	88	8	)	)	PUNCT
fuelectenerg-3675	88	9	can	can	AUX
fuelectenerg-3675	88	10	not	not	PART
fuelectenerg-3675	88	11	be	be	AUX
fuelectenerg-3675	88	12	used	use	VERB
fuelectenerg-3675	88	13	with	with	ADP
fuelectenerg-3675	88	14	good	good	ADJ
fuelectenerg-3675	88	15	accuracy	accuracy	NOUN
fuelectenerg-3675	88	16	in	in	ADP
fuelectenerg-3675	88	17	the	the	DET
fuelectenerg-3675	88	18	case	case	NOUN
fuelectenerg-3675	88	19	of	of	ADP
fuelectenerg-3675	88	20	a	a	DET
fuelectenerg-3675	88	21	large	large	ADJ
fuelectenerg-3675	88	22	-	-	PUNCT
fuelectenerg-3675	88	23	diameter	diameter	NOUN
fuelectenerg-3675	88	24	multilayer	multilayer	NOUN
fuelectenerg-3675	88	25	solenoid	solenoid	PROPN
fuelectenerg-3675	88	26	l0	l0	PROPN
fuelectenerg-3675	88	27	.	.	PUNCT
fuelectenerg-3675	89	1	if	if	SCONJ
fuelectenerg-3675	89	2	the	the	DET
fuelectenerg-3675	89	3	ferromagnetic	ferromagnetic	ADJ
fuelectenerg-3675	89	4	sample	sample	NOUN
fuelectenerg-3675	89	5	is	be	AUX
fuelectenerg-3675	89	6	placed	place	VERB
fuelectenerg-3675	89	7	inside	inside	ADP
fuelectenerg-3675	89	8	pickup	pickup	NOUN
fuelectenerg-3675	89	9	coil	coil	NOUN
fuelectenerg-3675	89	10	,	,	PUNCT
fuelectenerg-3675	89	11	according	accord	VERB
fuelectenerg-3675	89	12	to	to	ADP
fuelectenerg-3675	89	13	faraday	faraday	PROPN
fuelectenerg-3675	89	14	’s	’s	PART
fuelectenerg-3675	89	15	law	law	NOUN
fuelectenerg-3675	89	16	,	,	PUNCT
fuelectenerg-3675	89	17	a	a	DET
fuelectenerg-3675	89	18	voltage	voltage	NOUN
fuelectenerg-3675	89	19	induced	induce	VERB
fuelectenerg-3675	89	20	ul	ul	INTJ
fuelectenerg-3675	89	21	in	in	ADP
fuelectenerg-3675	89	22	the	the	DET
fuelectenerg-3675	89	23	pickup	pickup	NOUN
fuelectenerg-3675	89	24	coil	coil	NOUN
fuelectenerg-3675	89	25	is	be	AUX
fuelectenerg-3675	89	26	equal	equal	ADJ
fuelectenerg-3675	89	27	to	to	ADP
fuelectenerg-3675	89	28	[	[	X
fuelectenerg-3675	89	29	4	4	NUM
fuelectenerg-3675	89	30	]	]	PUNCT
fuelectenerg-3675	89	31	:	:	PUNCT
fuelectenerg-3675	89	32	0	0	NUM
fuelectenerg-3675	90	1	d	d	PUNCT
fuelectenerg-3675	90	2	d	d	PROPN
fuelectenerg-3675	90	3	d	d	PROPN
fuelectenerg-3675	90	4	d	d	PROPN
fuelectenerg-3675	90	5	d	d	PROPN
fuelectenerg-3675	90	6	d	d	NOUN
fuelectenerg-3675	90	7	l	l	NOUN
fuelectenerg-3675	91	1	p	p	NOUN
fuelectenerg-3675	91	2	p	p	X
fuelectenerg-3675	91	3	s	s	X
fuelectenerg-3675	91	4	p	p	NOUN
fuelectenerg-3675	91	5	m	m	NOUN
fuelectenerg-3675	91	6	h	h	NOUN
fuelectenerg-3675	91	7	u	u	NOUN
fuelectenerg-3675	91	8	n	n	CCONJ
fuelectenerg-3675	91	9	n	n	PROPN
fuelectenerg-3675	91	10	s	s	NOUN
fuelectenerg-3675	91	11	s	s	PROPN
fuelectenerg-3675	91	12	t	t	PROPN
fuelectenerg-3675	91	13	t	t	NOUN
fuelectenerg-3675	91	14	t	t	PROPN
fuelectenerg-3675	91	15			PROPN
fuelectenerg-3675	91	16			NOUN
fuelectenerg-3675	91	17			NOUN
fuelectenerg-3675	91	18			PROPN
fuelectenerg-3675	91	19			PROPN
fuelectenerg-3675	91	20			PROPN
fuelectenerg-3675	91	21			PROPN
fuelectenerg-3675	91	22			PROPN
fuelectenerg-3675	91	23			CCONJ
fuelectenerg-3675	91	24			PROPN
fuelectenerg-3675	91	25			NOUN
fuelectenerg-3675	91	26	,	,	PUNCT
fuelectenerg-3675	91	27	(	(	PUNCT
fuelectenerg-3675	91	28	2	2	X
fuelectenerg-3675	91	29	)	)	PUNCT
fuelectenerg-3675	91	30	where	where	SCONJ
fuelectenerg-3675	91	31	μ0	μ0	PROPN
fuelectenerg-3675	91	32	is	be	AUX
fuelectenerg-3675	91	33	the	the	DET
fuelectenerg-3675	91	34	permeability	permeability	NOUN
fuelectenerg-3675	91	35	of	of	ADP
fuelectenerg-3675	91	36	vacuum	vacuum	NOUN
fuelectenerg-3675	91	37	,	,	PUNCT
fuelectenerg-3675	91	38	np	np	INTJ
fuelectenerg-3675	91	39	is	be	AUX
fuelectenerg-3675	91	40	the	the	DET
fuelectenerg-3675	91	41	number	number	NOUN
fuelectenerg-3675	91	42	of	of	ADP
fuelectenerg-3675	91	43	the	the	DET
fuelectenerg-3675	91	44	turns	turn	NOUN
fuelectenerg-3675	91	45	of	of	ADP
fuelectenerg-3675	91	46	pickup	pickup	ADJ
fuelectenerg-3675	91	47	coil	coil	NOUN
fuelectenerg-3675	91	48	,	,	PUNCT
fuelectenerg-3675	91	49	sp	sp	NOUN
fuelectenerg-3675	91	50	is	be	AUX
fuelectenerg-3675	91	51	the	the	DET
fuelectenerg-3675	91	52	cross	cross	ADJ
fuelectenerg-3675	91	53	-	-	ADJ
fuelectenerg-3675	91	54	section	section	ADJ
fuelectenerg-3675	91	55	area	area	NOUN
fuelectenerg-3675	91	56	of	of	ADP
fuelectenerg-3675	91	57	the	the	DET
fuelectenerg-3675	91	58	pickup	pickup	NOUN
fuelectenerg-3675	91	59	coil	coil	NOUN
fuelectenerg-3675	91	60	,	,	PUNCT
fuelectenerg-3675	91	61	ss	ss	PROPN
fuelectenerg-3675	91	62	is	be	AUX
fuelectenerg-3675	91	63	the	the	DET
fuelectenerg-3675	91	64	cross	cross	ADJ
fuelectenerg-3675	91	65	-	-	ADJ
fuelectenerg-3675	91	66	section	section	ADJ
fuelectenerg-3675	91	67	area	area	NOUN
fuelectenerg-3675	91	68	of	of	ADP
fuelectenerg-3675	91	69	the	the	DET
fuelectenerg-3675	91	70	sample	sample	NOUN
fuelectenerg-3675	91	71	,	,	PUNCT
fuelectenerg-3675	91	72	φ	φ	PROPN
fuelectenerg-3675	91	73	is	be	AUX
fuelectenerg-3675	91	74	the	the	DET
fuelectenerg-3675	91	75	magnetic	magnetic	ADJ
fuelectenerg-3675	91	76	flux	flux	NOUN
fuelectenerg-3675	91	77	and	and	CCONJ
fuelectenerg-3675	91	78	m	m	PROPN
fuelectenerg-3675	91	79	is	be	AUX
fuelectenerg-3675	91	80	the	the	DET
fuelectenerg-3675	91	81	magnetisation	magnetisation	NOUN
fuelectenerg-3675	91	82	.	.	PUNCT
fuelectenerg-3675	92	1	the	the	DET
fuelectenerg-3675	92	2	voltage	voltage	NOUN
fuelectenerg-3675	92	3	measured	measure	VERB
fuelectenerg-3675	92	4	at	at	ADP
fuelectenerg-3675	92	5	the	the	DET
fuelectenerg-3675	92	6	non	non	ADJ
fuelectenerg-3675	92	7	-	-	ADJ
fuelectenerg-3675	92	8	common	common	ADJ
fuelectenerg-3675	92	9	ends	end	NOUN
fuelectenerg-3675	92	10	of	of	ADP
fuelectenerg-3675	92	11	the	the	DET
fuelectenerg-3675	92	12	pickup	pickup	ADJ
fuelectenerg-3675	92	13	coils	coil	NOUN
fuelectenerg-3675	92	14	in	in	ADP
fuelectenerg-3675	92	15	mutual	mutual	ADJ
fuelectenerg-3675	92	16	opposition	opposition	NOUN
fuelectenerg-3675	92	17	is	be	AUX
fuelectenerg-3675	92	18	equal	equal	ADJ
fuelectenerg-3675	92	19	to	to	ADP
fuelectenerg-3675	92	20	the	the	DET
fuelectenerg-3675	92	21	first	first	ADJ
fuelectenerg-3675	92	22	term	term	NOUN
fuelectenerg-3675	92	23	in	in	ADP
fuelectenerg-3675	92	24	the	the	DET
fuelectenerg-3675	92	25	expression	expression	NOUN
fuelectenerg-3675	92	26	(	(	PUNCT
fuelectenerg-3675	92	27	2	2	NUM
fuelectenerg-3675	92	28	)	)	PUNCT
fuelectenerg-3675	92	29	.	.	PUNCT
fuelectenerg-3675	93	1	if	if	SCONJ
fuelectenerg-3675	93	2	no	no	DET
fuelectenerg-3675	93	3	sample	sample	NOUN
fuelectenerg-3675	93	4	is	be	AUX
fuelectenerg-3675	93	5	placed	place	VERB
fuelectenerg-3675	93	6	inside	inside	ADP
fuelectenerg-3675	93	7	the	the	DET
fuelectenerg-3675	93	8	pickup	pickup	NOUN
fuelectenerg-3675	93	9	coil	coil	NOUN
fuelectenerg-3675	93	10	in	in	ADP
fuelectenerg-3675	93	11	mutual	mutual	ADJ
fuelectenerg-3675	93	12	opposition	opposition	NOUN
fuelectenerg-3675	93	13	,	,	PUNCT
fuelectenerg-3675	93	14	the	the	DET
fuelectenerg-3675	93	15	voltage	voltage	NOUN
fuelectenerg-3675	93	16	induced	induce	VERB
fuelectenerg-3675	93	17	in	in	ADP
fuelectenerg-3675	93	18	that	that	DET
fuelectenerg-3675	93	19	pickup	pickup	ADJ
fuelectenerg-3675	93	20	coil	coil	NOUN
fuelectenerg-3675	93	21	is	be	AUX
fuelectenerg-3675	93	22	equal	equal	ADJ
fuelectenerg-3675	93	23	to	to	ADP
fuelectenerg-3675	93	24	the	the	DET
fuelectenerg-3675	93	25	second	second	ADJ
fuelectenerg-3675	93	26	term	term	NOUN
fuelectenerg-3675	93	27	in	in	ADP
fuelectenerg-3675	93	28	the	the	DET
fuelectenerg-3675	93	29	expression	expression	NOUN
fuelectenerg-3675	93	30	(	(	PUNCT
fuelectenerg-3675	93	31	2	2	NUM
fuelectenerg-3675	93	32	)	)	PUNCT
fuelectenerg-3675	93	33	.	.	PUNCT
fuelectenerg-3675	94	1	if	if	SCONJ
fuelectenerg-3675	94	2	no	no	DET
fuelectenerg-3675	94	3	sample	sample	NOUN
fuelectenerg-3675	94	4	is	be	AUX
fuelectenerg-3675	94	5	placed	place	VERB
fuelectenerg-3675	94	6	inside	inside	ADP
fuelectenerg-3675	94	7	pickup	pickup	NOUN
fuelectenerg-3675	94	8	coils	coil	NOUN
fuelectenerg-3675	94	9	,	,	PUNCT
fuelectenerg-3675	94	10	induced	induced	ADJ
fuelectenerg-3675	94	11	voltages	voltage	NOUN
fuelectenerg-3675	94	12	are	be	AUX
fuelectenerg-3675	94	13	equal	equal	ADJ
fuelectenerg-3675	94	14	and	and	CCONJ
fuelectenerg-3675	94	15	the	the	DET
fuelectenerg-3675	94	16	resulting	result	VERB
fuelectenerg-3675	94	17	voltage	voltage	NOUN
fuelectenerg-3675	94	18	is	be	AUX
fuelectenerg-3675	94	19	equal	equal	ADJ
fuelectenerg-3675	94	20	to	to	ADP
fuelectenerg-3675	94	21	zero	zero	NUM
fuelectenerg-3675	94	22	or	or	CCONJ
fuelectenerg-3675	94	23	very	very	ADV
fuelectenerg-3675	94	24	close	close	ADJ
fuelectenerg-3675	94	25	to	to	ADP
fuelectenerg-3675	94	26	zero	zero	NUM
fuelectenerg-3675	94	27	.	.	PUNCT
fuelectenerg-3675	95	1	according	accord	VERB
fuelectenerg-3675	95	2	to	to	ADP
fuelectenerg-3675	95	3	the	the	DET
fuelectenerg-3675	95	4	iec	iec	NOUN
fuelectenerg-3675	95	5	standard	standard	NOUN
fuelectenerg-3675	95	6	for	for	ADP
fuelectenerg-3675	95	7	epstein	epstein	PROPN
fuelectenerg-3675	95	8	frame	frame	NOUN
fuelectenerg-3675	95	9	[	[	X
fuelectenerg-3675	95	10	6	6	NUM
fuelectenerg-3675	95	11	]	]	PUNCT
fuelectenerg-3675	95	12	,	,	PUNCT
fuelectenerg-3675	95	13	the	the	DET
fuelectenerg-3675	95	14	resulting	result	VERB
fuelectenerg-3675	95	15	voltage	voltage	NOUN
fuelectenerg-3675	95	16	should	should	AUX
fuelectenerg-3675	95	17	be	be	AUX
fuelectenerg-3675	95	18	smaller	small	ADJ
fuelectenerg-3675	95	19	than	than	ADP
fuelectenerg-3675	95	20	0.1	0.1	NUM
fuelectenerg-3675	95	21	%	%	NOUN
fuelectenerg-3675	95	22	of	of	ADP
fuelectenerg-3675	95	23	the	the	DET
fuelectenerg-3675	95	24	individual	individual	ADJ
fuelectenerg-3675	95	25	voltages	voltage	NOUN
fuelectenerg-3675	95	26	.	.	PUNCT
fuelectenerg-3675	96	1	expression	expression	NOUN
fuelectenerg-3675	96	2	(	(	PUNCT
fuelectenerg-3675	96	3	2	2	X
fuelectenerg-3675	96	4	)	)	PUNCT
fuelectenerg-3675	96	5	can	can	AUX
fuelectenerg-3675	96	6	not	not	PART
fuelectenerg-3675	96	7	be	be	AUX
fuelectenerg-3675	96	8	applied	apply	VERB
fuelectenerg-3675	96	9	to	to	ADP
fuelectenerg-3675	96	10	the	the	DET
fuelectenerg-3675	96	11	pickup	pickup	ADJ
fuelectenerg-3675	96	12	coils	coil	NOUN
fuelectenerg-3675	96	13	of	of	ADP
fuelectenerg-3675	96	14	the	the	DET
fuelectenerg-3675	96	15	described	describe	VERB
fuelectenerg-3675	96	16	magnetometer	magnetometer	NOUN
fuelectenerg-3675	96	17	since	since	SCONJ
fuelectenerg-3675	96	18	these	these	DET
fuelectenerg-3675	96	19	coils	coil	NOUN
fuelectenerg-3675	96	20	are	be	AUX
fuelectenerg-3675	96	21	multilayer	multilayer	ADJ
fuelectenerg-3675	96	22	coils	coil	NOUN
fuelectenerg-3675	96	23	and	and	CCONJ
fuelectenerg-3675	96	24	the	the	DET
fuelectenerg-3675	96	25	number	number	NOUN
fuelectenerg-3675	96	26	of	of	ADP
fuelectenerg-3675	96	27	turns	turn	NOUN
fuelectenerg-3675	96	28	is	be	AUX
fuelectenerg-3675	96	29	unknown	unknown	ADJ
fuelectenerg-3675	96	30	.	.	PUNCT
fuelectenerg-3675	97	1	3	3	X
fuelectenerg-3675	97	2	.	.	X
fuelectenerg-3675	97	3	calibration	calibration	NOUN
fuelectenerg-3675	97	4	procedure	procedure	NOUN
fuelectenerg-3675	97	5	and	and	CCONJ
fuelectenerg-3675	97	6	results	result	VERB
fuelectenerg-3675	97	7	the	the	DET
fuelectenerg-3675	97	8	calibration	calibration	NOUN
fuelectenerg-3675	97	9	of	of	ADP
fuelectenerg-3675	97	10	induction	induction	NOUN
fuelectenerg-3675	97	11	magnetometer	magnetometer	NOUN
fuelectenerg-3675	97	12	is	be	AUX
fuelectenerg-3675	97	13	performed	perform	VERB
fuelectenerg-3675	97	14	in	in	ADP
fuelectenerg-3675	97	15	three	three	NUM
fuelectenerg-3675	97	16	steps	step	NOUN
fuelectenerg-3675	97	17	:	:	PUNCT
fuelectenerg-3675	97	18	1	1	X
fuelectenerg-3675	97	19	.	.	X
fuelectenerg-3675	97	20	calibration	calibration	NOUN
fuelectenerg-3675	97	21	of	of	ADP
fuelectenerg-3675	97	22	hall	hall	PROPN
fuelectenerg-3675	97	23	sensor	sensor	NOUN
fuelectenerg-3675	97	24	,	,	PUNCT
fuelectenerg-3675	97	25	2	2	NUM
fuelectenerg-3675	97	26	.	.	X
fuelectenerg-3675	97	27	calibration	calibration	NOUN
fuelectenerg-3675	97	28	of	of	ADP
fuelectenerg-3675	97	29	large	large	ADJ
fuelectenerg-3675	97	30	solenoid	solenoid	NOUN
fuelectenerg-3675	97	31	and	and	CCONJ
fuelectenerg-3675	97	32	3	3	X
fuelectenerg-3675	97	33	.	.	X
fuelectenerg-3675	98	1	calibration	calibration	NOUN
fuelectenerg-3675	98	2	of	of	ADP
fuelectenerg-3675	98	3	pickup	pickup	ADJ
fuelectenerg-3675	98	4	coils	coil	NOUN
fuelectenerg-3675	98	5	.	.	PUNCT
fuelectenerg-3675	99	1	the	the	DET
fuelectenerg-3675	99	2	calibration	calibration	NOUN
fuelectenerg-3675	99	3	is	be	AUX
fuelectenerg-3675	99	4	necessary	necessary	ADJ
fuelectenerg-3675	99	5	because	because	SCONJ
fuelectenerg-3675	99	6	numbers	number	NOUN
fuelectenerg-3675	99	7	of	of	ADP
fuelectenerg-3675	99	8	turns	turn	NOUN
fuelectenerg-3675	99	9	of	of	ADP
fuelectenerg-3675	99	10	all	all	DET
fuelectenerg-3675	99	11	coils	coil	NOUN
fuelectenerg-3675	99	12	are	be	AUX
fuelectenerg-3675	99	13	unknown	unknown	ADJ
fuelectenerg-3675	99	14	for	for	ADP
fuelectenerg-3675	99	15	the	the	DET
fuelectenerg-3675	99	16	used	use	VERB
fuelectenerg-3675	99	17	induction	induction	NOUN
fuelectenerg-3675	99	18	magnetometer	magnetometer	NOUN
fuelectenerg-3675	99	19	.	.	PUNCT
fuelectenerg-3675	100	1	the	the	DET
fuelectenerg-3675	100	2	large	large	ADJ
fuelectenerg-3675	100	3	solenoid	solenoid	NOUN
fuelectenerg-3675	100	4	generates	generate	VERB
fuelectenerg-3675	100	5	a	a	DET
fuelectenerg-3675	100	6	homogeneous	homogeneous	ADJ
fuelectenerg-3675	100	7	magnetic	magnetic	ADJ
fuelectenerg-3675	100	8	618	618	NUM
fuelectenerg-3675	100	9	b.	b.	PROPN
fuelectenerg-3675	100	10	koprivica	koprivica	PROPN
fuelectenerg-3675	100	11	,	,	PUNCT
fuelectenerg-3675	100	12	m.	m.	NOUN
fuelectenerg-3675	100	13	šućurović	šućurović	PROPN
fuelectenerg-3675	100	14	,	,	PUNCT
fuelectenerg-3675	100	15	a.	a.	NOUN
fuelectenerg-3675	100	16	milovanović	milovanović	PROPN
fuelectenerg-3675	100	17	field	field	NOUN
fuelectenerg-3675	100	18	only	only	ADV
fuelectenerg-3675	100	19	in	in	ADP
fuelectenerg-3675	100	20	the	the	DET
fuelectenerg-3675	100	21	central	central	ADJ
fuelectenerg-3675	100	22	zone	zone	NOUN
fuelectenerg-3675	100	23	.	.	PUNCT
fuelectenerg-3675	101	1	even	even	ADV
fuelectenerg-3675	101	2	if	if	SCONJ
fuelectenerg-3675	101	3	this	this	PRON
fuelectenerg-3675	101	4	is	be	AUX
fuelectenerg-3675	101	5	not	not	PART
fuelectenerg-3675	101	6	the	the	DET
fuelectenerg-3675	101	7	case	case	NOUN
fuelectenerg-3675	101	8	,	,	PUNCT
fuelectenerg-3675	101	9	it	it	PRON
fuelectenerg-3675	101	10	is	be	AUX
fuelectenerg-3675	101	11	always	always	ADV
fuelectenerg-3675	101	12	better	well	ADJ
fuelectenerg-3675	101	13	to	to	PART
fuelectenerg-3675	101	14	perform	perform	VERB
fuelectenerg-3675	101	15	the	the	DET
fuelectenerg-3675	101	16	calibration	calibration	NOUN
fuelectenerg-3675	101	17	and	and	CCONJ
fuelectenerg-3675	101	18	to	to	PART
fuelectenerg-3675	101	19	compare	compare	VERB
fuelectenerg-3675	101	20	obtained	obtain	VERB
fuelectenerg-3675	101	21	results	result	NOUN
fuelectenerg-3675	101	22	with	with	ADP
fuelectenerg-3675	101	23	calculations	calculation	NOUN
fuelectenerg-3675	101	24	.	.	PUNCT
fuelectenerg-3675	102	1	all	all	DET
fuelectenerg-3675	102	2	measurements	measurement	NOUN
fuelectenerg-3675	102	3	are	be	AUX
fuelectenerg-3675	102	4	performed	perform	VERB
fuelectenerg-3675	102	5	with	with	ADP
fuelectenerg-3675	102	6	controlled	control	VERB
fuelectenerg-3675	102	7	sinusoidal	sinusoidal	ADJ
fuelectenerg-3675	102	8	excitation	excitation	NOUN
fuelectenerg-3675	102	9	voltage	voltage	NOUN
fuelectenerg-3675	102	10	and	and	CCONJ
fuelectenerg-3675	102	11	current	current	ADJ
fuelectenerg-3675	102	12	,	,	PUNCT
fuelectenerg-3675	102	13	at	at	ADP
fuelectenerg-3675	102	14	the	the	DET
fuelectenerg-3675	102	15	frequency	frequency	NOUN
fuelectenerg-3675	102	16	of	of	ADP
fuelectenerg-3675	102	17	50	50	NUM
fuelectenerg-3675	102	18	hz	hz	NOUN
fuelectenerg-3675	102	19	.	.	PUNCT
fuelectenerg-3675	103	1	ni	ni	PROPN
fuelectenerg-3675	103	2	usb	usb	PROPN
fuelectenerg-3675	103	3	6009	6009	NUM
fuelectenerg-3675	103	4	data	datum	NOUN
fuelectenerg-3675	103	5	acquisition	acquisition	NOUN
fuelectenerg-3675	103	6	card	card	NOUN
fuelectenerg-3675	103	7	is	be	AUX
fuelectenerg-3675	103	8	used	use	VERB
fuelectenerg-3675	103	9	in	in	ADP
fuelectenerg-3675	103	10	all	all	DET
fuelectenerg-3675	103	11	measurements	measurement	NOUN
fuelectenerg-3675	103	12	[	[	X
fuelectenerg-3675	103	13	7	7	NUM
fuelectenerg-3675	103	14	]	]	PUNCT
fuelectenerg-3675	103	15	.	.	PUNCT
fuelectenerg-3675	104	1	three	three	NUM
fuelectenerg-3675	104	2	simple	simple	ADJ
fuelectenerg-3675	104	3	labview	labview	NOUN
fuelectenerg-3675	104	4	applications	application	NOUN
fuelectenerg-3675	104	5	are	be	AUX
fuelectenerg-3675	104	6	developed	develop	VERB
fuelectenerg-3675	104	7	for	for	ADP
fuelectenerg-3675	104	8	each	each	DET
fuelectenerg-3675	104	9	step	step	NOUN
fuelectenerg-3675	104	10	of	of	ADP
fuelectenerg-3675	104	11	the	the	DET
fuelectenerg-3675	104	12	calibration	calibration	NOUN
fuelectenerg-3675	104	13	.	.	PUNCT
fuelectenerg-3675	105	1	in	in	ADP
fuelectenerg-3675	105	2	all	all	DET
fuelectenerg-3675	105	3	measurements	measurement	NOUN
fuelectenerg-3675	105	4	the	the	DET
fuelectenerg-3675	105	5	averaging	averaging	NOUN
fuelectenerg-3675	105	6	is	be	AUX
fuelectenerg-3675	105	7	used	use	VERB
fuelectenerg-3675	105	8	to	to	PART
fuelectenerg-3675	105	9	reduce	reduce	VERB
fuelectenerg-3675	105	10	the	the	DET
fuelectenerg-3675	105	11	noise	noise	NOUN
fuelectenerg-3675	105	12	[	[	X
fuelectenerg-3675	105	13	8	8	NUM
fuelectenerg-3675	105	14	]	]	SYM
fuelectenerg-3675	105	15	.	.	PUNCT
fuelectenerg-3675	106	1	3.1	3.1	NUM
fuelectenerg-3675	106	2	.	.	PUNCT
fuelectenerg-3675	106	3	calibration	calibration	NOUN
fuelectenerg-3675	106	4	of	of	ADP
fuelectenerg-3675	106	5	hall	hall	NOUN
fuelectenerg-3675	106	6	sensor	sensor	PROPN
fuelectenerg-3675	106	7	the	the	DET
fuelectenerg-3675	106	8	hall	hall	NOUN
fuelectenerg-3675	106	9	sensor	sensor	NOUN
fuelectenerg-3675	106	10	ss49e	ss49e	NOUN
fuelectenerg-3675	106	11	has	have	VERB
fuelectenerg-3675	106	12	linear	linear	ADJ
fuelectenerg-3675	106	13	output	output	NOUN
fuelectenerg-3675	106	14	voltage	voltage	NOUN
fuelectenerg-3675	106	15	in	in	ADP
fuelectenerg-3675	106	16	the	the	DET
fuelectenerg-3675	106	17	range	range	NOUN
fuelectenerg-3675	106	18	of	of	ADP
fuelectenerg-3675	106	19	magnetic	magnetic	ADJ
fuelectenerg-3675	106	20	flux	flux	NOUN
fuelectenerg-3675	106	21	density	density	NOUN
fuelectenerg-3675	106	22	from	from	ADP
fuelectenerg-3675	106	23	−100	−100	PROPN
fuelectenerg-3675	106	24	mt	mt	PROPN
fuelectenerg-3675	106	25	to	to	ADP
fuelectenerg-3675	106	26	100	100	NUM
fuelectenerg-3675	106	27	mt	mt	PROPN
fuelectenerg-3675	107	1	[	[	X
fuelectenerg-3675	107	2	9	9	NUM
fuelectenerg-3675	107	3	]	]	PUNCT
fuelectenerg-3675	107	4	.	.	PUNCT
fuelectenerg-3675	108	1	therefore	therefore	ADV
fuelectenerg-3675	108	2	,	,	PUNCT
fuelectenerg-3675	108	3	it	it	PRON
fuelectenerg-3675	108	4	is	be	AUX
fuelectenerg-3675	108	5	suitable	suitable	ADJ
fuelectenerg-3675	108	6	for	for	ADP
fuelectenerg-3675	108	7	measurement	measurement	NOUN
fuelectenerg-3675	108	8	of	of	ADP
fuelectenerg-3675	108	9	the	the	DET
fuelectenerg-3675	108	10	magnetic	magnetic	PROPN
fuelectenerg-3675	108	11	flux	flux	PROPN
fuelectenerg-3675	108	12	density	density	NOUN
fuelectenerg-3675	108	13	generated	generate	VERB
fuelectenerg-3675	108	14	by	by	ADP
fuelectenerg-3675	108	15	large	large	ADJ
fuelectenerg-3675	108	16	solenoid	solenoid	PROPN
fuelectenerg-3675	108	17	l0	l0	PROPN
fuelectenerg-3675	108	18	.	.	PUNCT
fuelectenerg-3675	109	1	however	however	ADV
fuelectenerg-3675	109	2	,	,	PUNCT
fuelectenerg-3675	109	3	it	it	PRON
fuelectenerg-3675	109	4	needs	need	VERB
fuelectenerg-3675	109	5	to	to	PART
fuelectenerg-3675	109	6	be	be	AUX
fuelectenerg-3675	109	7	calibrated	calibrate	VERB
fuelectenerg-3675	109	8	in	in	ADP
fuelectenerg-3675	109	9	order	order	NOUN
fuelectenerg-3675	109	10	to	to	PART
fuelectenerg-3675	109	11	determine	determine	VERB
fuelectenerg-3675	109	12	its	its	PRON
fuelectenerg-3675	109	13	sensitivity	sensitivity	NOUN
fuelectenerg-3675	109	14	.	.	PUNCT
fuelectenerg-3675	110	1	a	a	DET
fuelectenerg-3675	110	2	calibration	calibration	NOUN
fuelectenerg-3675	110	3	is	be	AUX
fuelectenerg-3675	110	4	performed	perform	VERB
fuelectenerg-3675	110	5	using	use	VERB
fuelectenerg-3675	110	6	a	a	DET
fuelectenerg-3675	110	7	long	long	ADJ
fuelectenerg-3675	110	8	solenoid	solenoid	NOUN
fuelectenerg-3675	110	9	(	(	PUNCT
fuelectenerg-3675	110	10	l=340	l=340	NOUN
fuelectenerg-3675	110	11	mm	mm	NOUN
fuelectenerg-3675	110	12	)	)	PUNCT
fuelectenerg-3675	110	13	with	with	ADP
fuelectenerg-3675	110	14	small	small	ADJ
fuelectenerg-3675	110	15	diameter	diameter	NOUN
fuelectenerg-3675	110	16	(	(	PUNCT
fuelectenerg-3675	110	17	25	25	NUM
fuelectenerg-3675	110	18	mm	mm	NOUN
fuelectenerg-3675	110	19	)	)	PUNCT
fuelectenerg-3675	110	20	.	.	PUNCT
fuelectenerg-3675	111	1	a	a	DET
fuelectenerg-3675	111	2	varnished	varnish	VERB
fuelectenerg-3675	111	3	copper	copper	NOUN
fuelectenerg-3675	111	4	wire	wire	NOUN
fuelectenerg-3675	111	5	of	of	ADP
fuelectenerg-3675	111	6	1.8	1.8	NUM
fuelectenerg-3675	111	7	mm	mm	NOUN
fuelectenerg-3675	111	8	thick	thick	ADJ
fuelectenerg-3675	111	9	is	be	AUX
fuelectenerg-3675	111	10	used	use	VERB
fuelectenerg-3675	111	11	for	for	ADP
fuelectenerg-3675	111	12	winding	winding	NOUN
fuelectenerg-3675	111	13	of	of	ADP
fuelectenerg-3675	111	14	n=190	n=190	NUM
fuelectenerg-3675	111	15	turns	turn	NOUN
fuelectenerg-3675	111	16	of	of	ADP
fuelectenerg-3675	111	17	this	this	DET
fuelectenerg-3675	111	18	solenoid	solenoid	NOUN
fuelectenerg-3675	111	19	.	.	PUNCT
fuelectenerg-3675	112	1	an	an	DET
fuelectenerg-3675	112	2	electric	electric	ADJ
fuelectenerg-3675	112	3	current	current	ADJ
fuelectenerg-3675	112	4	i(t	i(t	PROPN
fuelectenerg-3675	112	5	)	)	PUNCT
fuelectenerg-3675	112	6	of	of	ADP
fuelectenerg-3675	112	7	the	the	DET
fuelectenerg-3675	112	8	solenoid	solenoid	NOUN
fuelectenerg-3675	112	9	is	be	AUX
fuelectenerg-3675	112	10	measured	measure	VERB
fuelectenerg-3675	112	11	using	use	VERB
fuelectenerg-3675	112	12	a	a	DET
fuelectenerg-3675	112	13	shunt	shunt	NOUN
fuelectenerg-3675	112	14	resistor	resistor	NOUN
fuelectenerg-3675	112	15	(	(	PUNCT
fuelectenerg-3675	112	16	20	20	NUM
fuelectenerg-3675	112	17	a	a	PRON
fuelectenerg-3675	112	18	,	,	PUNCT
fuelectenerg-3675	112	19	75	75	NUM
fuelectenerg-3675	112	20	mv	mv	NOUN
fuelectenerg-3675	112	21	)	)	PUNCT
fuelectenerg-3675	112	22	.	.	PUNCT
fuelectenerg-3675	113	1	the	the	DET
fuelectenerg-3675	113	2	magnetic	magnetic	PROPN
fuelectenerg-3675	113	3	flux	flux	NOUN
fuelectenerg-3675	113	4	density	density	NOUN
fuelectenerg-3675	113	5	is	be	AUX
fuelectenerg-3675	113	6	calculated	calculate	VERB
fuelectenerg-3675	113	7	as	as	SCONJ
fuelectenerg-3675	113	8	follows	follow	VERB
fuelectenerg-3675	113	9	:	:	PUNCT
fuelectenerg-3675	113	10	0	0	PUNCT
fuelectenerg-3675	114	1	(	(	PUNCT
fuelectenerg-3675	114	2	)	)	PUNCT
fuelectenerg-3675	114	3	(	(	PUNCT
fuelectenerg-3675	114	4	)	)	PUNCT
fuelectenerg-3675	114	5	ni	ni	PROPN
fuelectenerg-3675	114	6	t	t	PROPN
fuelectenerg-3675	114	7	b	b	PROPN
fuelectenerg-3675	114	8	t	t	PROPN
fuelectenerg-3675	114	9	l	l	NOUN
fuelectenerg-3675	114	10			NOUN
fuelectenerg-3675	114	11			NOUN
fuelectenerg-3675	114	12	.	.	PUNCT
fuelectenerg-3675	115	1	(	(	PUNCT
fuelectenerg-3675	115	2	3	3	X
fuelectenerg-3675	115	3	)	)	PUNCT
fuelectenerg-3675	115	4	the	the	DET
fuelectenerg-3675	115	5	sensor	sensor	NOUN
fuelectenerg-3675	115	6	characteristic	characteristic	ADJ
fuelectenerg-3675	115	7	uhmax	uhmax	NOUN
fuelectenerg-3675	115	8	=	=	SYM
fuelectenerg-3675	115	9	f(bmax	f(bmax	ADV
fuelectenerg-3675	115	10	)	)	PUNCT
fuelectenerg-3675	115	11	is	be	AUX
fuelectenerg-3675	115	12	obtained	obtain	VERB
fuelectenerg-3675	115	13	according	accord	VERB
fuelectenerg-3675	115	14	to	to	ADP
fuelectenerg-3675	115	15	the	the	DET
fuelectenerg-3675	115	16	maximum	maximum	NOUN
fuelectenerg-3675	115	17	of	of	ADP
fuelectenerg-3675	115	18	the	the	DET
fuelectenerg-3675	115	19	voltage	voltage	NOUN
fuelectenerg-3675	115	20	uh	uh	INTJ
fuelectenerg-3675	115	21	measured	measure	VERB
fuelectenerg-3675	115	22	at	at	ADP
fuelectenerg-3675	115	23	the	the	DET
fuelectenerg-3675	115	24	output	output	NOUN
fuelectenerg-3675	115	25	of	of	ADP
fuelectenerg-3675	115	26	the	the	DET
fuelectenerg-3675	115	27	sensor	sensor	NOUN
fuelectenerg-3675	115	28	and	and	CCONJ
fuelectenerg-3675	115	29	the	the	DET
fuelectenerg-3675	115	30	maximum	maximum	NOUN
fuelectenerg-3675	115	31	of	of	ADP
fuelectenerg-3675	115	32	the	the	DET
fuelectenerg-3675	115	33	magnetic	magnetic	ADJ
fuelectenerg-3675	115	34	flux	flux	NOUN
fuelectenerg-3675	115	35	density	density	NOUN
fuelectenerg-3675	115	36	calculated	calculate	VERB
fuelectenerg-3675	115	37	using	use	VERB
fuelectenerg-3675	115	38	expression	expression	NOUN
fuelectenerg-3675	115	39	(	(	PUNCT
fuelectenerg-3675	115	40	3	3	NUM
fuelectenerg-3675	115	41	)	)	PUNCT
fuelectenerg-3675	115	42	.	.	PUNCT
fuelectenerg-3675	116	1	measurements	measurement	NOUN
fuelectenerg-3675	116	2	are	be	AUX
fuelectenerg-3675	116	3	performed	perform	VERB
fuelectenerg-3675	116	4	in	in	ADP
fuelectenerg-3675	116	5	the	the	DET
fuelectenerg-3675	116	6	increasing	increase	VERB
fuelectenerg-3675	116	7	and	and	CCONJ
fuelectenerg-3675	116	8	the	the	DET
fuelectenerg-3675	116	9	decreasing	decrease	VERB
fuelectenerg-3675	116	10	direction	direction	NOUN
fuelectenerg-3675	116	11	in	in	ADP
fuelectenerg-3675	116	12	order	order	NOUN
fuelectenerg-3675	116	13	to	to	PART
fuelectenerg-3675	116	14	examine	examine	VERB
fuelectenerg-3675	116	15	the	the	DET
fuelectenerg-3675	116	16	linearity	linearity	NOUN
fuelectenerg-3675	116	17	of	of	ADP
fuelectenerg-3675	116	18	the	the	DET
fuelectenerg-3675	116	19	characteristic	characteristic	NOUN
fuelectenerg-3675	116	20	.	.	PUNCT
fuelectenerg-3675	117	1	a	a	DET
fuelectenerg-3675	117	2	sensitivity	sensitivity	NOUN
fuelectenerg-3675	117	3	of	of	ADP
fuelectenerg-3675	117	4	the	the	DET
fuelectenerg-3675	117	5	sensor	sensor	NOUN
fuelectenerg-3675	117	6	is	be	AUX
fuelectenerg-3675	117	7	calculated	calculate	VERB
fuelectenerg-3675	117	8	from	from	ADP
fuelectenerg-3675	117	9	the	the	DET
fuelectenerg-3675	117	10	slope	slope	NOUN
fuelectenerg-3675	117	11	of	of	ADP
fuelectenerg-3675	117	12	the	the	DET
fuelectenerg-3675	117	13	obtained	obtain	VERB
fuelectenerg-3675	117	14	characteristic	characteristic	NOUN
fuelectenerg-3675	117	15	.	.	PUNCT
fuelectenerg-3675	118	1	characteristics	characteristic	NOUN
fuelectenerg-3675	118	2	of	of	ADP
fuelectenerg-3675	118	3	the	the	DET
fuelectenerg-3675	118	4	sensor	sensor	NOUN
fuelectenerg-3675	118	5	(	(	PUNCT
fuelectenerg-3675	118	6	blue	blue	ADJ
fuelectenerg-3675	118	7	lines	line	NOUN
fuelectenerg-3675	118	8	)	)	PUNCT
fuelectenerg-3675	118	9	obtained	obtain	VERB
fuelectenerg-3675	118	10	from	from	ADP
fuelectenerg-3675	118	11	two	two	NUM
fuelectenerg-3675	118	12	measurements	measurement	NOUN
fuelectenerg-3675	118	13	for	for	ADP
fuelectenerg-3675	118	14	maximal	maximal	ADJ
fuelectenerg-3675	118	15	magnetic	magnetic	ADJ
fuelectenerg-3675	118	16	flux	flux	NOUN
fuelectenerg-3675	118	17	densities	density	NOUN
fuelectenerg-3675	118	18	of	of	ADP
fuelectenerg-3675	118	19	10	10	NUM
fuelectenerg-3675	118	20	mt	mt	PROPN
fuelectenerg-3675	118	21	(	(	PUNCT
fuelectenerg-3675	118	22	green	green	ADJ
fuelectenerg-3675	118	23	squares	square	NOUN
fuelectenerg-3675	118	24	)	)	PUNCT
fuelectenerg-3675	118	25	and	and	CCONJ
fuelectenerg-3675	118	26	20	20	NUM
fuelectenerg-3675	118	27	mt	mt	PROPN
fuelectenerg-3675	118	28	(	(	PUNCT
fuelectenerg-3675	118	29	red	red	ADJ
fuelectenerg-3675	118	30	circles	circle	NOUN
fuelectenerg-3675	118	31	)	)	PUNCT
fuelectenerg-3675	118	32	are	be	AUX
fuelectenerg-3675	118	33	presented	present	VERB
fuelectenerg-3675	118	34	in	in	ADP
fuelectenerg-3675	118	35	fig	fig	NOUN
fuelectenerg-3675	118	36	.	.	PUNCT
fuelectenerg-3675	119	1	5	5	NUM
fuelectenerg-3675	119	2	.	.	NOUN
fuelectenerg-3675	119	3	0.0	0.0	NUM
fuelectenerg-3675	120	1	2.5	2.5	NUM
fuelectenerg-3675	120	2	5.0	5.0	NUM
fuelectenerg-3675	120	3	7.5	7.5	NUM
fuelectenerg-3675	120	4	10.0	10.0	NUM
fuelectenerg-3675	120	5	12.5	12.5	NUM
fuelectenerg-3675	120	6	15.0	15.0	NUM
fuelectenerg-3675	120	7	17.5	17.5	NUM
fuelectenerg-3675	120	8	20.0	20.0	NUM
fuelectenerg-3675	120	9	0.0	0.0	NUM
fuelectenerg-3675	120	10	0.1	0.1	NUM
fuelectenerg-3675	120	11	0.2	0.2	NUM
fuelectenerg-3675	120	12	0.3	0.3	NUM
fuelectenerg-3675	120	13	0.4	0.4	NUM
fuelectenerg-3675	120	14	0.5	0.5	NUM
fuelectenerg-3675	120	15	0.6	0.6	NUM
fuelectenerg-3675	120	16	measured	measure	VERB
fuelectenerg-3675	120	17	up	up	ADP
fuelectenerg-3675	120	18	to	to	PART
fuelectenerg-3675	120	19	10	10	NUM
fuelectenerg-3675	120	20	mt	mt	PROPN
fuelectenerg-3675	120	21	measured	measure	VERB
fuelectenerg-3675	120	22	up	up	ADP
fuelectenerg-3675	120	23	to	to	PART
fuelectenerg-3675	120	24	20	20	NUM
fuelectenerg-3675	120	25	mt	mt	PROPN
fuelectenerg-3675	120	26	linear	linear	PROPN
fuelectenerg-3675	120	27	fit	fit	PROPN
fuelectenerg-3675	120	28	u	u	PROPN
fuelectenerg-3675	121	1	h	h	NOUN
fuelectenerg-3675	121	2	m	m	VERB
fuelectenerg-3675	121	3	ax	ax	ADJ
fuelectenerg-3675	121	4	[	[	PUNCT
fuelectenerg-3675	121	5	v	v	NOUN
fuelectenerg-3675	121	6	]	]	PUNCT
fuelectenerg-3675	121	7	equation	equation	NOUN
fuelectenerg-3675	121	8	y	y	NOUN
fuelectenerg-3675	121	9	=	=	PUNCT
fuelectenerg-3675	122	1	a	a	DET
fuelectenerg-3675	122	2	+	+	NUM
fuelectenerg-3675	122	3	bx	bx	NOUN
fuelectenerg-3675	122	4	slope	slope	NOUN
fuelectenerg-3675	122	5	(	(	PUNCT
fuelectenerg-3675	122	6	b	b	NOUN
fuelectenerg-3675	122	7	)	)	PUNCT
fuelectenerg-3675	122	8	stand	stand	NOUN
fuelectenerg-3675	122	9	.	.	PUNCT
fuelectenerg-3675	123	1	deviation	deviation	NOUN
fuelectenerg-3675	123	2	adj	adj	PROPN
fuelectenerg-3675	123	3	.	.	PUNCT
fuelectenerg-3675	124	1	r	r	X
fuelectenerg-3675	124	2	-	-	PUNCT
fuelectenerg-3675	124	3	square	square	ADJ
fuelectenerg-3675	124	4	20	20	NUM
fuelectenerg-3675	124	5	mt	mt	PROPN
fuelectenerg-3675	124	6	0.02991	0.02991	NUM
fuelectenerg-3675	124	7	2.57e-4	2.57e-4	NOUN
fuelectenerg-3675	124	8	0.99957	0.99957	NUM
fuelectenerg-3675	124	9	10	10	NUM
fuelectenerg-3675	124	10	mt	mt	NOUN
fuelectenerg-3675	124	11	0.03026	0.03026	NUM
fuelectenerg-3675	124	12	1.25e-4	1.25e-4	NUM
fuelectenerg-3675	125	1	0.99889	0.99889	NUM
fuelectenerg-3675	125	2	b	b	X
fuelectenerg-3675	125	3	max	max	PROPN
fuelectenerg-3675	126	1	[	[	X
fuelectenerg-3675	126	2	mt	mt	X
fuelectenerg-3675	126	3	]	]	X
fuelectenerg-3675	126	4	fig	fig	NOUN
fuelectenerg-3675	126	5	.	.	PUNCT
fuelectenerg-3675	127	1	5	5	NUM
fuelectenerg-3675	127	2	calibration	calibration	NOUN
fuelectenerg-3675	127	3	of	of	ADP
fuelectenerg-3675	127	4	hall	hall	NOUN
fuelectenerg-3675	127	5	sensor	sensor	NOUN
fuelectenerg-3675	127	6	measurement	measurement	NOUN
fuelectenerg-3675	127	7	results	result	NOUN
fuelectenerg-3675	127	8	and	and	CCONJ
fuelectenerg-3675	127	9	linear	linear	VERB
fuelectenerg-3675	127	10	fit	fit	ADJ
fuelectenerg-3675	127	11	calibration	calibration	NOUN
fuelectenerg-3675	127	12	of	of	ADP
fuelectenerg-3675	127	13	ac	ac	PROPN
fuelectenerg-3675	127	14	induction	induction	NOUN
fuelectenerg-3675	127	15	magnetometer	magnetometer	NOUN
fuelectenerg-3675	127	16	619	619	NUM
fuelectenerg-3675	127	17	the	the	DET
fuelectenerg-3675	127	18	figure	figure	NOUN
fuelectenerg-3675	127	19	presents	present	VERB
fuelectenerg-3675	127	20	also	also	ADV
fuelectenerg-3675	127	21	a	a	DET
fuelectenerg-3675	127	22	table	table	NOUN
fuelectenerg-3675	127	23	with	with	ADP
fuelectenerg-3675	127	24	calculated	calculate	VERB
fuelectenerg-3675	127	25	slopes	slope	NOUN
fuelectenerg-3675	127	26	,	,	PUNCT
fuelectenerg-3675	127	27	standard	standard	ADJ
fuelectenerg-3675	127	28	errors	error	NOUN
fuelectenerg-3675	127	29	and	and	CCONJ
fuelectenerg-3675	127	30	adjusted	adjusted	ADJ
fuelectenerg-3675	127	31	rsquares	rsquare	NOUN
fuelectenerg-3675	127	32	.	.	PUNCT
fuelectenerg-3675	128	1	for	for	ADP
fuelectenerg-3675	128	2	a	a	DET
fuelectenerg-3675	128	3	given	give	VERB
fuelectenerg-3675	128	4	dataset	dataset	NOUN
fuelectenerg-3675	128	5	(	(	PUNCT
fuelectenerg-3675	128	6	xi	xi	PROPN
fuelectenerg-3675	128	7	,	,	PUNCT
fuelectenerg-3675	128	8	yi	yi	PROPN
fuelectenerg-3675	128	9	)	)	PUNCT
fuelectenerg-3675	128	10	,	,	PUNCT
fuelectenerg-3675	128	11	i=1	i=1	PROPN
fuelectenerg-3675	128	12	,	,	PUNCT
fuelectenerg-3675	128	13	2	2	NUM
fuelectenerg-3675	128	14	,	,	PUNCT
fuelectenerg-3675	128	15	…	…	PUNCT
fuelectenerg-3675	128	16	,	,	PUNCT
fuelectenerg-3675	128	17	n	n	CCONJ
fuelectenerg-3675	128	18	,	,	PUNCT
fuelectenerg-3675	128	19	the	the	DET
fuelectenerg-3675	128	20	standard	standard	ADJ
fuelectenerg-3675	128	21	deviation	deviation	NOUN
fuelectenerg-3675	128	22	(	(	PUNCT
fuelectenerg-3675	128	23	error	error	NOUN
fuelectenerg-3675	128	24	)	)	PUNCT
fuelectenerg-3675	128	25	ε	ε	PROPN
fuelectenerg-3675	128	26	and	and	CCONJ
fuelectenerg-3675	128	27	the	the	DET
fuelectenerg-3675	128	28	adjusted	adjusted	ADJ
fuelectenerg-3675	128	29	r	r	NOUN
fuelectenerg-3675	128	30	-	-	PUNCT
fuelectenerg-3675	128	31	square	square	ADJ
fuelectenerg-3675	128	32	2r	2r	NUM
fuelectenerg-3675	128	33	of	of	ADP
fuelectenerg-3675	128	34	linear	linear	PROPN
fuelectenerg-3675	128	35	model	model	NOUN
fuelectenerg-3675	128	36	y	y	PROPN
fuelectenerg-3675	128	37	=	=	PROPN
fuelectenerg-3675	128	38	a+bx	a+bx	ADV
fuelectenerg-3675	128	39	can	can	AUX
fuelectenerg-3675	128	40	be	be	AUX
fuelectenerg-3675	128	41	calculated	calculate	VERB
fuelectenerg-3675	128	42	as	as	ADP
fuelectenerg-3675	128	43	[	[	X
fuelectenerg-3675	128	44	10	10	NUM
fuelectenerg-3675	128	45	]	]	SYM
fuelectenerg-3675	128	46	:	:	PUNCT
fuelectenerg-3675	128	47	2	2	NUM
fuelectenerg-3675	128	48	1	1	NUM
fuelectenerg-3675	128	49	2	2	NUM
fuelectenerg-3675	128	50	1	1	NUM
fuelectenerg-3675	128	51	(	(	PUNCT
fuelectenerg-3675	128	52	(	(	PUNCT
fuelectenerg-3675	128	53	)	)	PUNCT
fuelectenerg-3675	128	54	)	)	PUNCT
fuelectenerg-3675	129	1	1	1	NUM
fuelectenerg-3675	129	2	n	n	NOUN
fuelectenerg-3675	129	3	i	i	PRON
fuelectenerg-3675	130	1	i	i	PRON
fuelectenerg-3675	130	2	i	i	PRON
fuelectenerg-3675	131	1	n	n	VERB
fuelectenerg-3675	132	1	i	i	PRON
fuelectenerg-3675	132	2	i	i	INTJ
fuelectenerg-3675	132	3	y	y	VERB
fuelectenerg-3675	132	4	a	a	DET
fuelectenerg-3675	132	5	bx	bx	NOUN
fuelectenerg-3675	132	6	n	n	NOUN
fuelectenerg-3675	132	7	x	x	NOUN
fuelectenerg-3675	132	8			NUM
fuelectenerg-3675	132	9			PROPN
fuelectenerg-3675	132	10			PROPN
fuelectenerg-3675	132	11			CCONJ
fuelectenerg-3675	132	12			PROPN
fuelectenerg-3675	132	13			PROPN
fuelectenerg-3675	132	14			PRON
fuelectenerg-3675	132	15			X
fuelectenerg-3675	132	16			X
fuelectenerg-3675	132	17	,	,	PUNCT
fuelectenerg-3675	132	18	(	(	PUNCT
fuelectenerg-3675	132	19	4	4	X
fuelectenerg-3675	132	20	)	)	SYM
fuelectenerg-3675	132	21	2	2	NUM
fuelectenerg-3675	132	22	1	1	NUM
fuelectenerg-3675	132	23	2	2	NUM
fuelectenerg-3675	132	24	2	2	NUM
fuelectenerg-3675	132	25	1	1	NUM
fuelectenerg-3675	132	26	1	1	NUM
fuelectenerg-3675	132	27	(	(	PUNCT
fuelectenerg-3675	132	28	(	(	PUNCT
fuelectenerg-3675	132	29	)	)	PUNCT
fuelectenerg-3675	132	30	)	)	PUNCT
fuelectenerg-3675	132	31	11	11	NUM
fuelectenerg-3675	132	32	;	;	PUNCT
fuelectenerg-3675	132	33	(	(	PUNCT
fuelectenerg-3675	132	34	)	)	PUNCT
fuelectenerg-3675	132	35	n	n	CCONJ
fuelectenerg-3675	133	1	i	i	PRON
fuelectenerg-3675	133	2	i	i	PRON
fuelectenerg-3675	133	3	i	i	PRON
fuelectenerg-3675	133	4	n	n	VERB
fuelectenerg-3675	133	5	in	in	ADP
fuelectenerg-3675	133	6	i	i	PRON
fuelectenerg-3675	134	1	i	i	PRON
fuelectenerg-3675	134	2	i	i	VERB
fuelectenerg-3675	134	3	y	y	VERB
fuelectenerg-3675	135	1	a	a	PRON
fuelectenerg-3675	135	2	bx	bx	NOUN
fuelectenerg-3675	135	3	nr	nr	NOUN
fuelectenerg-3675	135	4	y	y	PROPN
fuelectenerg-3675	135	5	y	y	PROPN
fuelectenerg-3675	135	6	y	y	PROPN
fuelectenerg-3675	135	7	y	y	PROPN
fuelectenerg-3675	136	1	n	n	CCONJ
fuelectenerg-3675	136	2			NUM
fuelectenerg-3675	137	1			PROPN
fuelectenerg-3675	137	2			PROPN
fuelectenerg-3675	137	3			PROPN
fuelectenerg-3675	137	4			VERB
fuelectenerg-3675	137	5			ADJ
fuelectenerg-3675	137	6			PROPN
fuelectenerg-3675	137	7			PROPN
fuelectenerg-3675	137	8			PROPN
fuelectenerg-3675	137	9			X
fuelectenerg-3675	137	10			X
fuelectenerg-3675	137	11			X
fuelectenerg-3675	137	12	.	.	PUNCT
fuelectenerg-3675	138	1	(	(	PUNCT
fuelectenerg-3675	138	2	5	5	NUM
fuelectenerg-3675	138	3	)	)	PUNCT
fuelectenerg-3675	138	4	according	accord	VERB
fuelectenerg-3675	138	5	to	to	ADP
fuelectenerg-3675	138	6	fig	fig	NOUN
fuelectenerg-3675	138	7	.	.	PUNCT
fuelectenerg-3675	139	1	5	5	NUM
fuelectenerg-3675	139	2	,	,	PUNCT
fuelectenerg-3675	139	3	the	the	DET
fuelectenerg-3675	139	4	sensitivity	sensitivity	NOUN
fuelectenerg-3675	139	5	of	of	ADP
fuelectenerg-3675	139	6	hall	hall	NOUN
fuelectenerg-3675	139	7	sensor	sensor	NOUN
fuelectenerg-3675	139	8	is	be	AUX
fuelectenerg-3675	139	9	equal	equal	ADJ
fuelectenerg-3675	139	10	to	to	ADP
fuelectenerg-3675	139	11	s=0.03	s=0.03	ADJ
fuelectenerg-3675	139	12	v	v	PROPN
fuelectenerg-3675	139	13	/	/	SYM
fuelectenerg-3675	139	14	mt	mt	PROPN
fuelectenerg-3675	139	15	.	.	PUNCT
fuelectenerg-3675	140	1	it	it	PRON
fuelectenerg-3675	140	2	is	be	AUX
fuelectenerg-3675	140	3	interesting	interesting	ADJ
fuelectenerg-3675	140	4	to	to	PART
fuelectenerg-3675	140	5	notice	notice	VERB
fuelectenerg-3675	140	6	that	that	SCONJ
fuelectenerg-3675	140	7	both	both	DET
fuelectenerg-3675	140	8	measurements	measurement	NOUN
fuelectenerg-3675	140	9	in	in	ADP
fuelectenerg-3675	140	10	fig	fig	NOUN
fuelectenerg-3675	140	11	.	.	PUNCT
fuelectenerg-3675	141	1	5	5	NUM
fuelectenerg-3675	141	2	show	show	VERB
fuelectenerg-3675	141	3	a	a	DET
fuelectenerg-3675	141	4	dispersion	dispersion	NOUN
fuelectenerg-3675	141	5	of	of	ADP
fuelectenerg-3675	141	6	results	result	NOUN
fuelectenerg-3675	141	7	.	.	PUNCT
fuelectenerg-3675	142	1	this	this	DET
fuelectenerg-3675	142	2	effect	effect	NOUN
fuelectenerg-3675	142	3	has	have	AUX
fuelectenerg-3675	142	4	been	be	AUX
fuelectenerg-3675	142	5	examined	examine	VERB
fuelectenerg-3675	142	6	more	more	ADV
fuelectenerg-3675	142	7	thoroughly	thoroughly	ADV
fuelectenerg-3675	142	8	.	.	PUNCT
fuelectenerg-3675	143	1	it	it	PRON
fuelectenerg-3675	143	2	has	have	AUX
fuelectenerg-3675	143	3	been	be	AUX
fuelectenerg-3675	143	4	found	find	VERB
fuelectenerg-3675	143	5	that	that	SCONJ
fuelectenerg-3675	143	6	this	this	DET
fuelectenerg-3675	143	7	behaviour	behaviour	NOUN
fuelectenerg-3675	143	8	comes	come	VERB
fuelectenerg-3675	143	9	from	from	ADP
fuelectenerg-3675	143	10	the	the	DET
fuelectenerg-3675	143	11	heating	heating	NOUN
fuelectenerg-3675	143	12	and	and	CCONJ
fuelectenerg-3675	143	13	cooling	cooling	NOUN
fuelectenerg-3675	143	14	of	of	ADP
fuelectenerg-3675	143	15	the	the	DET
fuelectenerg-3675	143	16	shunt	shunt	NOUN
fuelectenerg-3675	143	17	resistor	resistor	NOUN
fuelectenerg-3675	143	18	during	during	ADP
fuelectenerg-3675	143	19	the	the	DET
fuelectenerg-3675	143	20	measurement	measurement	NOUN
fuelectenerg-3675	143	21	of	of	ADP
fuelectenerg-3675	143	22	electric	electric	PROPN
fuelectenerg-3675	143	23	current	current	NOUN
fuelectenerg-3675	143	24	.	.	PUNCT
fuelectenerg-3675	144	1	for	for	ADP
fuelectenerg-3675	144	2	lower	low	ADJ
fuelectenerg-3675	144	3	values	value	NOUN
fuelectenerg-3675	144	4	of	of	ADP
fuelectenerg-3675	144	5	the	the	DET
fuelectenerg-3675	144	6	supply	supply	NOUN
fuelectenerg-3675	144	7	current	current	NOUN
fuelectenerg-3675	144	8	(	(	PUNCT
fuelectenerg-3675	144	9	up	up	ADP
fuelectenerg-3675	144	10	to	to	PART
fuelectenerg-3675	144	11	10	10	NUM
fuelectenerg-3675	144	12	a	a	PRON
fuelectenerg-3675	144	13	,	,	PUNCT
fuelectenerg-3675	144	14	rms	rm	NOUN
fuelectenerg-3675	144	15	)	)	PUNCT
fuelectenerg-3675	144	16	this	this	DET
fuelectenerg-3675	144	17	effect	effect	NOUN
fuelectenerg-3675	144	18	is	be	AUX
fuelectenerg-3675	144	19	not	not	PART
fuelectenerg-3675	144	20	expressed	express	VERB
fuelectenerg-3675	144	21	so	so	ADV
fuelectenerg-3675	144	22	much	much	ADJ
fuelectenerg-3675	144	23	(	(	PUNCT
fuelectenerg-3675	144	24	green	green	ADJ
fuelectenerg-3675	144	25	squares	square	NOUN
fuelectenerg-3675	144	26	)	)	PUNCT
fuelectenerg-3675	144	27	and	and	CCONJ
fuelectenerg-3675	144	28	it	it	PRON
fuelectenerg-3675	144	29	can	can	AUX
fuelectenerg-3675	144	30	be	be	AUX
fuelectenerg-3675	144	31	neglected	neglect	VERB
fuelectenerg-3675	144	32	.	.	PUNCT
fuelectenerg-3675	145	1	therefore	therefore	ADV
fuelectenerg-3675	145	2	,	,	PUNCT
fuelectenerg-3675	145	3	it	it	PRON
fuelectenerg-3675	145	4	can	can	AUX
fuelectenerg-3675	145	5	be	be	AUX
fuelectenerg-3675	145	6	concluded	conclude	VERB
fuelectenerg-3675	145	7	that	that	SCONJ
fuelectenerg-3675	145	8	the	the	DET
fuelectenerg-3675	145	9	sensor	sensor	NOUN
fuelectenerg-3675	145	10	output	output	NOUN
fuelectenerg-3675	145	11	is	be	AUX
fuelectenerg-3675	145	12	linear	linear	ADJ
fuelectenerg-3675	145	13	with	with	ADP
fuelectenerg-3675	145	14	a	a	DET
fuelectenerg-3675	145	15	constant	constant	ADJ
fuelectenerg-3675	145	16	sensitivity	sensitivity	NOUN
fuelectenerg-3675	145	17	.	.	PUNCT
fuelectenerg-3675	146	1	however	however	ADV
fuelectenerg-3675	146	2	,	,	PUNCT
fuelectenerg-3675	146	3	the	the	DET
fuelectenerg-3675	146	4	second	second	ADJ
fuelectenerg-3675	146	5	measurement	measurement	NOUN
fuelectenerg-3675	146	6	(	(	PUNCT
fuelectenerg-3675	146	7	red	red	ADJ
fuelectenerg-3675	146	8	circles	circle	NOUN
fuelectenerg-3675	146	9	)	)	PUNCT
fuelectenerg-3675	146	10	shows	show	VERB
fuelectenerg-3675	146	11	significant	significant	ADJ
fuelectenerg-3675	146	12	dispersion	dispersion	NOUN
fuelectenerg-3675	146	13	of	of	ADP
fuelectenerg-3675	146	14	the	the	DET
fuelectenerg-3675	146	15	results	result	NOUN
fuelectenerg-3675	146	16	and	and	CCONJ
fuelectenerg-3675	146	17	the	the	DET
fuelectenerg-3675	146	18	calculated	calculate	VERB
fuelectenerg-3675	146	19	slope	slope	NOUN
fuelectenerg-3675	146	20	is	be	AUX
fuelectenerg-3675	146	21	lower	low	ADJ
fuelectenerg-3675	146	22	by	by	ADP
fuelectenerg-3675	146	23	1.16	1.16	NUM
fuelectenerg-3675	146	24	%	%	NOUN
fuelectenerg-3675	146	25	than	than	ADP
fuelectenerg-3675	146	26	in	in	ADP
fuelectenerg-3675	146	27	the	the	DET
fuelectenerg-3675	146	28	first	first	ADJ
fuelectenerg-3675	146	29	measurement	measurement	NOUN
fuelectenerg-3675	146	30	.	.	PUNCT
fuelectenerg-3675	147	1	such	such	DET
fuelectenerg-3675	147	2	a	a	DET
fuelectenerg-3675	147	3	difference	difference	NOUN
fuelectenerg-3675	147	4	can	can	AUX
fuelectenerg-3675	147	5	be	be	AUX
fuelectenerg-3675	147	6	in	in	ADP
fuelectenerg-3675	147	7	the	the	DET
fuelectenerg-3675	147	8	range	range	NOUN
fuelectenerg-3675	147	9	or	or	CCONJ
fuelectenerg-3675	147	10	even	even	ADV
fuelectenerg-3675	147	11	higher	high	ADJ
fuelectenerg-3675	147	12	than	than	ADP
fuelectenerg-3675	147	13	the	the	DET
fuelectenerg-3675	147	14	overall	overall	ADJ
fuelectenerg-3675	147	15	measurement	measurement	NOUN
fuelectenerg-3675	147	16	uncertainty	uncertainty	NOUN
fuelectenerg-3675	147	17	of	of	ADP
fuelectenerg-3675	147	18	the	the	DET
fuelectenerg-3675	147	19	experiment	experiment	NOUN
fuelectenerg-3675	147	20	(	(	PUNCT
fuelectenerg-3675	147	21	discussed	discuss	VERB
fuelectenerg-3675	147	22	in	in	ADP
fuelectenerg-3675	147	23	details	detail	NOUN
fuelectenerg-3675	147	24	in	in	ADP
fuelectenerg-3675	147	25	section	section	NOUN
fuelectenerg-3675	147	26	4	4	NUM
fuelectenerg-3675	147	27	)	)	PUNCT
fuelectenerg-3675	147	28	.	.	PUNCT
fuelectenerg-3675	148	1	therefore	therefore	ADV
fuelectenerg-3675	148	2	,	,	PUNCT
fuelectenerg-3675	148	3	attention	attention	NOUN
fuelectenerg-3675	148	4	needs	need	VERB
fuelectenerg-3675	148	5	to	to	PART
fuelectenerg-3675	148	6	be	be	AUX
fuelectenerg-3675	148	7	paid	pay	VERB
fuelectenerg-3675	148	8	to	to	ADP
fuelectenerg-3675	148	9	such	such	ADJ
fuelectenerg-3675	148	10	effect	effect	NOUN
fuelectenerg-3675	148	11	and	and	CCONJ
fuelectenerg-3675	148	12	its	its	PRON
fuelectenerg-3675	148	13	influence	influence	NOUN
fuelectenerg-3675	148	14	on	on	ADP
fuelectenerg-3675	148	15	the	the	DET
fuelectenerg-3675	148	16	calculated	calculate	VERB
fuelectenerg-3675	148	17	results	result	NOUN
fuelectenerg-3675	148	18	.	.	PUNCT
fuelectenerg-3675	149	1	3.2	3.2	NUM
fuelectenerg-3675	149	2	.	.	PUNCT
fuelectenerg-3675	149	3	calibration	calibration	NOUN
fuelectenerg-3675	149	4	of	of	ADP
fuelectenerg-3675	149	5	large	large	ADJ
fuelectenerg-3675	149	6	solenoid	solenoid	NOUN
fuelectenerg-3675	149	7	the	the	DET
fuelectenerg-3675	149	8	calibration	calibration	NOUN
fuelectenerg-3675	149	9	of	of	ADP
fuelectenerg-3675	149	10	the	the	DET
fuelectenerg-3675	149	11	large	large	ADJ
fuelectenerg-3675	149	12	solenoid	solenoid	NOUN
fuelectenerg-3675	149	13	is	be	AUX
fuelectenerg-3675	149	14	performed	perform	VERB
fuelectenerg-3675	149	15	with	with	ADP
fuelectenerg-3675	149	16	the	the	DET
fuelectenerg-3675	149	17	calibrated	calibrate	VERB
fuelectenerg-3675	149	18	hall	hall	NOUN
fuelectenerg-3675	149	19	sensor	sensor	NOUN
fuelectenerg-3675	149	20	.	.	PUNCT
fuelectenerg-3675	150	1	at	at	ADP
fuelectenerg-3675	150	2	this	this	DET
fuelectenerg-3675	150	3	step	step	NOUN
fuelectenerg-3675	150	4	,	,	PUNCT
fuelectenerg-3675	150	5	dependence	dependence	NOUN
fuelectenerg-3675	150	6	of	of	ADP
fuelectenerg-3675	150	7	the	the	DET
fuelectenerg-3675	150	8	magnetic	magnetic	PROPN
fuelectenerg-3675	150	9	flux	flux	PROPN
fuelectenerg-3675	150	10	density	density	NOUN
fuelectenerg-3675	150	11	generated	generate	VERB
fuelectenerg-3675	150	12	by	by	ADP
fuelectenerg-3675	150	13	the	the	DET
fuelectenerg-3675	150	14	large	large	ADJ
fuelectenerg-3675	150	15	solenoid	solenoid	NOUN
fuelectenerg-3675	150	16	on	on	ADP
fuelectenerg-3675	150	17	its	its	PRON
fuelectenerg-3675	150	18	electric	electric	ADJ
fuelectenerg-3675	150	19	current	current	NOUN
fuelectenerg-3675	150	20	is	be	AUX
fuelectenerg-3675	150	21	examined	examine	VERB
fuelectenerg-3675	150	22	.	.	PUNCT
fuelectenerg-3675	151	1	a	a	DET
fuelectenerg-3675	151	2	final	final	ADJ
fuelectenerg-3675	151	3	result	result	NOUN
fuelectenerg-3675	151	4	of	of	ADP
fuelectenerg-3675	151	5	the	the	DET
fuelectenerg-3675	151	6	calibration	calibration	NOUN
fuelectenerg-3675	151	7	is	be	AUX
fuelectenerg-3675	151	8	bmax	bmax	ADJ
fuelectenerg-3675	151	9	=	=	NOUN
fuelectenerg-3675	151	10	f(imax	f(imax	NOUN
fuelectenerg-3675	151	11	)	)	PUNCT
fuelectenerg-3675	151	12	characteristic	characteristic	NOUN
fuelectenerg-3675	151	13	of	of	ADP
fuelectenerg-3675	151	14	the	the	DET
fuelectenerg-3675	151	15	large	large	ADJ
fuelectenerg-3675	151	16	solenoid	solenoid	NOUN
fuelectenerg-3675	151	17	.	.	PUNCT
fuelectenerg-3675	152	1	the	the	DET
fuelectenerg-3675	152	2	electric	electric	ADJ
fuelectenerg-3675	152	3	current	current	NOUN
fuelectenerg-3675	152	4	of	of	ADP
fuelectenerg-3675	152	5	the	the	DET
fuelectenerg-3675	152	6	large	large	ADJ
fuelectenerg-3675	152	7	solenoid	solenoid	NOUN
fuelectenerg-3675	152	8	is	be	AUX
fuelectenerg-3675	152	9	measured	measure	VERB
fuelectenerg-3675	152	10	using	use	VERB
fuelectenerg-3675	152	11	a	a	DET
fuelectenerg-3675	152	12	shunt	shunt	NOUN
fuelectenerg-3675	152	13	resistor	resistor	NOUN
fuelectenerg-3675	152	14	.	.	PUNCT
fuelectenerg-3675	153	1	the	the	DET
fuelectenerg-3675	153	2	magnetic	magnetic	PROPN
fuelectenerg-3675	153	3	flux	flux	NOUN
fuelectenerg-3675	153	4	density	density	NOUN
fuelectenerg-3675	153	5	is	be	AUX
fuelectenerg-3675	153	6	calculated	calculate	VERB
fuelectenerg-3675	153	7	using	use	VERB
fuelectenerg-3675	153	8	the	the	DET
fuelectenerg-3675	153	9	measured	measure	VERB
fuelectenerg-3675	153	10	output	output	NOUN
fuelectenerg-3675	153	11	voltage	voltage	NOUN
fuelectenerg-3675	153	12	of	of	ADP
fuelectenerg-3675	153	13	hall	hall	NOUN
fuelectenerg-3675	153	14	sensor	sensor	NOUN
fuelectenerg-3675	153	15	and	and	CCONJ
fuelectenerg-3675	153	16	dividing	divide	VERB
fuelectenerg-3675	153	17	it	it	PRON
fuelectenerg-3675	153	18	with	with	ADP
fuelectenerg-3675	153	19	the	the	DET
fuelectenerg-3675	153	20	sensitivity	sensitivity	NOUN
fuelectenerg-3675	153	21	s	s	AUX
fuelectenerg-3675	153	22	obtained	obtain	VERB
fuelectenerg-3675	153	23	in	in	ADP
fuelectenerg-3675	153	24	the	the	DET
fuelectenerg-3675	153	25	previous	previous	ADJ
fuelectenerg-3675	153	26	step	step	NOUN
fuelectenerg-3675	153	27	.	.	PUNCT
fuelectenerg-3675	154	1	the	the	DET
fuelectenerg-3675	154	2	hall	hall	NOUN
fuelectenerg-3675	154	3	sensor	sensor	NOUN
fuelectenerg-3675	154	4	is	be	AUX
fuelectenerg-3675	154	5	placed	place	VERB
fuelectenerg-3675	154	6	in	in	ADP
fuelectenerg-3675	154	7	the	the	DET
fuelectenerg-3675	154	8	middle	middle	NOUN
fuelectenerg-3675	154	9	of	of	ADP
fuelectenerg-3675	154	10	large	large	ADJ
fuelectenerg-3675	154	11	solenoid	solenoid	NOUN
fuelectenerg-3675	154	12	,	,	PUNCT
fuelectenerg-3675	154	13	so	so	SCONJ
fuelectenerg-3675	154	14	that	that	SCONJ
fuelectenerg-3675	154	15	the	the	DET
fuelectenerg-3675	154	16	sensor	sensor	NOUN
fuelectenerg-3675	154	17	surface	surface	NOUN
fuelectenerg-3675	154	18	is	be	AUX
fuelectenerg-3675	154	19	perpendicular	perpendicular	ADJ
fuelectenerg-3675	154	20	to	to	ADP
fuelectenerg-3675	154	21	its	its	PRON
fuelectenerg-3675	154	22	longitudinal	longitudinal	ADJ
fuelectenerg-3675	154	23	axis	axis	NOUN
fuelectenerg-3675	154	24	and	and	CCONJ
fuelectenerg-3675	154	25	the	the	DET
fuelectenerg-3675	154	26	magnetic	magnetic	ADJ
fuelectenerg-3675	154	27	field	field	NOUN
fuelectenerg-3675	154	28	.	.	PUNCT
fuelectenerg-3675	155	1	measurements	measurement	NOUN
fuelectenerg-3675	155	2	are	be	AUX
fuelectenerg-3675	155	3	performed	perform	VERB
fuelectenerg-3675	155	4	with	with	ADP
fuelectenerg-3675	155	5	the	the	DET
fuelectenerg-3675	155	6	increasing	increase	VERB
fuelectenerg-3675	155	7	and	and	CCONJ
fuelectenerg-3675	155	8	the	the	DET
fuelectenerg-3675	155	9	decreasing	decreasing	NOUN
fuelectenerg-3675	155	10	of	of	ADP
fuelectenerg-3675	155	11	the	the	DET
fuelectenerg-3675	155	12	electric	electric	ADJ
fuelectenerg-3675	155	13	current	current	NOUN
fuelectenerg-3675	155	14	in	in	ADP
fuelectenerg-3675	155	15	order	order	NOUN
fuelectenerg-3675	155	16	to	to	PART
fuelectenerg-3675	155	17	examine	examine	VERB
fuelectenerg-3675	155	18	the	the	DET
fuelectenerg-3675	155	19	linearity	linearity	NOUN
fuelectenerg-3675	155	20	of	of	ADP
fuelectenerg-3675	155	21	the	the	DET
fuelectenerg-3675	155	22	characteristic	characteristic	NOUN
fuelectenerg-3675	155	23	.	.	PUNCT
fuelectenerg-3675	156	1	the	the	DET
fuelectenerg-3675	156	2	result	result	NOUN
fuelectenerg-3675	156	3	of	of	ADP
fuelectenerg-3675	156	4	the	the	DET
fuelectenerg-3675	156	5	calibration	calibration	NOUN
fuelectenerg-3675	156	6	of	of	ADP
fuelectenerg-3675	156	7	the	the	DET
fuelectenerg-3675	156	8	large	large	ADJ
fuelectenerg-3675	156	9	solenoid	solenoid	NOUN
fuelectenerg-3675	156	10	is	be	AUX
fuelectenerg-3675	156	11	presented	present	VERB
fuelectenerg-3675	156	12	in	in	ADP
fuelectenerg-3675	156	13	fig	fig	NOUN
fuelectenerg-3675	156	14	.	.	PUNCT
fuelectenerg-3675	157	1	6	6	NUM
fuelectenerg-3675	157	2	.	.	PUNCT
fuelectenerg-3675	157	3	according	accord	VERB
fuelectenerg-3675	157	4	to	to	ADP
fuelectenerg-3675	157	5	the	the	DET
fuelectenerg-3675	157	6	linear	linear	ADJ
fuelectenerg-3675	157	7	fit	fit	NOUN
fuelectenerg-3675	157	8	of	of	ADP
fuelectenerg-3675	157	9	measured	measure	VERB
fuelectenerg-3675	157	10	results	result	NOUN
fuelectenerg-3675	157	11	,	,	PUNCT
fuelectenerg-3675	157	12	the	the	DET
fuelectenerg-3675	157	13	slope	slope	NOUN
fuelectenerg-3675	157	14	of	of	ADP
fuelectenerg-3675	157	15	the	the	DET
fuelectenerg-3675	157	16	b	b	NOUN
fuelectenerg-3675	157	17	=	=	SYM
fuelectenerg-3675	157	18	f(i	f(i	ADJ
fuelectenerg-3675	157	19	)	)	PUNCT
fuelectenerg-3675	157	20	characteristic	characteristic	NOUN
fuelectenerg-3675	157	21	of	of	ADP
fuelectenerg-3675	157	22	large	large	ADJ
fuelectenerg-3675	157	23	solenoid	solenoid	NOUN
fuelectenerg-3675	157	24	is	be	AUX
fuelectenerg-3675	157	25	620	620	NUM
fuelectenerg-3675	157	26	b.	b.	PROPN
fuelectenerg-3675	157	27	koprivica	koprivica	PROPN
fuelectenerg-3675	157	28	,	,	PUNCT
fuelectenerg-3675	157	29	m.	m.	NOUN
fuelectenerg-3675	157	30	šućurović	šućurović	PROPN
fuelectenerg-3675	157	31	,	,	PUNCT
fuelectenerg-3675	157	32	a.	a.	NOUN
fuelectenerg-3675	157	33	milovanović	milovanović	NOUN
fuelectenerg-3675	157	34	around	around	ADP
fuelectenerg-3675	157	35	19.77	19.77	NUM
fuelectenerg-3675	157	36	mt	mt	PROPN
fuelectenerg-3675	157	37	/	/	SYM
fuelectenerg-3675	157	38	a.	a.	NOUN
fuelectenerg-3675	157	39	the	the	DET
fuelectenerg-3675	157	40	linearity	linearity	NOUN
fuelectenerg-3675	157	41	of	of	ADP
fuelectenerg-3675	157	42	this	this	DET
fuelectenerg-3675	157	43	characteristic	characteristic	NOUN
fuelectenerg-3675	157	44	confirms	confirm	VERB
fuelectenerg-3675	157	45	the	the	DET
fuelectenerg-3675	157	46	conclusion	conclusion	NOUN
fuelectenerg-3675	157	47	from	from	ADP
fuelectenerg-3675	157	48	the	the	DET
fuelectenerg-3675	157	49	calibration	calibration	NOUN
fuelectenerg-3675	157	50	of	of	ADP
fuelectenerg-3675	157	51	the	the	DET
fuelectenerg-3675	157	52	hall	hall	NOUN
fuelectenerg-3675	157	53	sensor	sensor	NOUN
fuelectenerg-3675	157	54	that	that	DET
fuelectenerg-3675	157	55	dispersion	dispersion	NOUN
fuelectenerg-3675	157	56	of	of	ADP
fuelectenerg-3675	157	57	measurement	measurement	NOUN
fuelectenerg-3675	157	58	results	result	NOUN
fuelectenerg-3675	157	59	comes	come	VERB
fuelectenerg-3675	157	60	from	from	ADP
fuelectenerg-3675	157	61	the	the	DET
fuelectenerg-3675	157	62	variation	variation	NOUN
fuelectenerg-3675	157	63	of	of	ADP
fuelectenerg-3675	157	64	temperature	temperature	NOUN
fuelectenerg-3675	157	65	of	of	ADP
fuelectenerg-3675	157	66	the	the	DET
fuelectenerg-3675	157	67	shunt	shunt	NOUN
fuelectenerg-3675	157	68	resistor	resistor	NOUN
fuelectenerg-3675	157	69	.	.	PUNCT
fuelectenerg-3675	158	1	the	the	DET
fuelectenerg-3675	158	2	obtained	obtain	VERB
fuelectenerg-3675	158	3	slope	slope	NOUN
fuelectenerg-3675	158	4	can	can	AUX
fuelectenerg-3675	158	5	be	be	AUX
fuelectenerg-3675	158	6	used	use	VERB
fuelectenerg-3675	158	7	in	in	ADP
fuelectenerg-3675	158	8	further	further	ADJ
fuelectenerg-3675	158	9	measurements	measurement	NOUN
fuelectenerg-3675	158	10	in	in	ADP
fuelectenerg-3675	158	11	the	the	DET
fuelectenerg-3675	158	12	calculation	calculation	NOUN
fuelectenerg-3675	158	13	of	of	ADP
fuelectenerg-3675	158	14	the	the	DET
fuelectenerg-3675	158	15	magnetic	magnetic	PROPN
fuelectenerg-3675	158	16	flux	flux	PROPN
fuelectenerg-3675	158	17	density	density	NOUN
fuelectenerg-3675	158	18	generated	generate	VERB
fuelectenerg-3675	158	19	by	by	ADP
fuelectenerg-3675	158	20	the	the	DET
fuelectenerg-3675	158	21	large	large	ADJ
fuelectenerg-3675	158	22	solenoid	solenoid	NOUN
fuelectenerg-3675	158	23	according	accord	VERB
fuelectenerg-3675	158	24	to	to	ADP
fuelectenerg-3675	158	25	the	the	DET
fuelectenerg-3675	158	26	measured	measured	ADJ
fuelectenerg-3675	158	27	current	current	NOUN
fuelectenerg-3675	158	28	.	.	PUNCT
fuelectenerg-3675	159	1	0.0	0.0	NUM
fuelectenerg-3675	159	2	0.2	0.2	NUM
fuelectenerg-3675	159	3	0.4	0.4	NUM
fuelectenerg-3675	159	4	0.6	0.6	NUM
fuelectenerg-3675	159	5	0.8	0.8	NUM
fuelectenerg-3675	159	6	1.0	1.0	NUM
fuelectenerg-3675	159	7	1.2	1.2	NUM
fuelectenerg-3675	159	8	1.4	1.4	NUM
fuelectenerg-3675	159	9	1.6	1.6	NUM
fuelectenerg-3675	159	10	1.8	1.8	NUM
fuelectenerg-3675	159	11	0	0	NUM
fuelectenerg-3675	159	12	5	5	NUM
fuelectenerg-3675	159	13	10	10	NUM
fuelectenerg-3675	159	14	15	15	NUM
fuelectenerg-3675	159	15	20	20	NUM
fuelectenerg-3675	159	16	25	25	NUM
fuelectenerg-3675	159	17	30	30	NUM
fuelectenerg-3675	159	18	35	35	NUM
fuelectenerg-3675	160	1	i	i	PRON
fuelectenerg-3675	160	2	max	max	PROPN
fuelectenerg-3675	161	1	[	[	X
fuelectenerg-3675	161	2	a	a	X
fuelectenerg-3675	161	3	]	]	X
fuelectenerg-3675	161	4	b	b	NOUN
fuelectenerg-3675	161	5	m	m	VERB
fuelectenerg-3675	161	6	ax	ax	NOUN
fuelectenerg-3675	161	7	[	[	PUNCT
fuelectenerg-3675	161	8	m	m	NOUN
fuelectenerg-3675	161	9	t	t	X
fuelectenerg-3675	161	10	]	]	PUNCT
fuelectenerg-3675	161	11	measured	measure	VERB
fuelectenerg-3675	161	12	increasing	increase	VERB
fuelectenerg-3675	161	13	measured	measured	ADJ
fuelectenerg-3675	161	14	decreasing	decrease	VERB
fuelectenerg-3675	161	15	linear	linear	ADJ
fuelectenerg-3675	161	16	fit	fit	ADJ
fuelectenerg-3675	161	17	equation	equation	NOUN
fuelectenerg-3675	161	18	y	y	NOUN
fuelectenerg-3675	161	19	=	=	PUNCT
fuelectenerg-3675	162	1	a	a	DET
fuelectenerg-3675	162	2	+	+	NUM
fuelectenerg-3675	162	3	bx	bx	NOUN
fuelectenerg-3675	162	4	slope	slope	NOUN
fuelectenerg-3675	162	5	(	(	PUNCT
fuelectenerg-3675	162	6	b	b	NOUN
fuelectenerg-3675	162	7	)	)	PUNCT
fuelectenerg-3675	162	8	stand	stand	NOUN
fuelectenerg-3675	162	9	.	.	PUNCT
fuelectenerg-3675	163	1	deviation	deviation	NOUN
fuelectenerg-3675	163	2	adj	adj	PROPN
fuelectenerg-3675	163	3	.	.	PUNCT
fuelectenerg-3675	164	1	r	r	NOUN
fuelectenerg-3675	164	2	-	-	PUNCT
fuelectenerg-3675	164	3	square	square	ADJ
fuelectenerg-3675	164	4	linear	linear	NOUN
fuelectenerg-3675	164	5	fit	fit	VERB
fuelectenerg-3675	164	6	19.768	19.768	NUM
fuelectenerg-3675	164	7	0.0244	0.0244	NUM
fuelectenerg-3675	164	8	0.999	0.999	NUM
fuelectenerg-3675	164	9	fig	fig	NOUN
fuelectenerg-3675	164	10	.	.	PUNCT
fuelectenerg-3675	165	1	6	6	NUM
fuelectenerg-3675	165	2	calibration	calibration	NOUN
fuelectenerg-3675	165	3	of	of	ADP
fuelectenerg-3675	165	4	large	large	ADJ
fuelectenerg-3675	165	5	solenoid	solenoid	NOUN
fuelectenerg-3675	165	6	measurement	measurement	NOUN
fuelectenerg-3675	165	7	results	result	NOUN
fuelectenerg-3675	165	8	and	and	CCONJ
fuelectenerg-3675	165	9	linear	linear	ADJ
fuelectenerg-3675	165	10	fit	fit	ADJ
fuelectenerg-3675	165	11	3.3	3.3	NUM
fuelectenerg-3675	165	12	.	.	PUNCT
fuelectenerg-3675	166	1	calibration	calibration	NOUN
fuelectenerg-3675	166	2	of	of	ADP
fuelectenerg-3675	166	3	pickup	pickup	ADJ
fuelectenerg-3675	166	4	coils	coil	NOUN
fuelectenerg-3675	166	5	in	in	ADP
fuelectenerg-3675	166	6	the	the	DET
fuelectenerg-3675	166	7	third	third	ADJ
fuelectenerg-3675	166	8	step	step	NOUN
fuelectenerg-3675	166	9	of	of	ADP
fuelectenerg-3675	166	10	calibration	calibration	NOUN
fuelectenerg-3675	166	11	,	,	PUNCT
fuelectenerg-3675	166	12	voltages	voltage	NOUN
fuelectenerg-3675	166	13	induced	induce	VERB
fuelectenerg-3675	166	14	in	in	ADP
fuelectenerg-3675	166	15	the	the	DET
fuelectenerg-3675	166	16	pickup	pickup	NOUN
fuelectenerg-3675	166	17	coils	coil	NOUN
fuelectenerg-3675	166	18	l1	l1	PROPN
fuelectenerg-3675	166	19	,	,	PUNCT
fuelectenerg-3675	166	20	l′2	l′2	PROPN
fuelectenerg-3675	166	21	and	and	CCONJ
fuelectenerg-3675	166	22	l′3	l′3	PROPN
fuelectenerg-3675	166	23	(	(	PUNCT
fuelectenerg-3675	166	24	fig	fig	NOUN
fuelectenerg-3675	166	25	.	.	PUNCT
fuelectenerg-3675	166	26	2b	2b	NUM
fuelectenerg-3675	166	27	)	)	PUNCT
fuelectenerg-3675	166	28	and	and	CCONJ
fuelectenerg-3675	166	29	voltages	voltage	NOUN
fuelectenerg-3675	166	30	at	at	ADP
fuelectenerg-3675	166	31	the	the	DET
fuelectenerg-3675	166	32	ends	end	NOUN
fuelectenerg-3675	166	33	of	of	ADP
fuelectenerg-3675	166	34	mutual	mutual	ADJ
fuelectenerg-3675	166	35	pickup	pickup	NOUN
fuelectenerg-3675	166	36	coils	coil	NOUN
fuelectenerg-3675	166	37	l2	l2	NOUN
fuelectenerg-3675	166	38	-	-	PUNCT
fuelectenerg-3675	166	39	l′2	l′2	NOUN
fuelectenerg-3675	166	40	and	and	CCONJ
fuelectenerg-3675	166	41	l3	l3	PROPN
fuelectenerg-3675	166	42	-	-	PUNCT
fuelectenerg-3675	166	43	l′3	l′3	PROPN
fuelectenerg-3675	166	44	are	be	AUX
fuelectenerg-3675	166	45	measured	measure	VERB
fuelectenerg-3675	166	46	in	in	ADP
fuelectenerg-3675	166	47	order	order	NOUN
fuelectenerg-3675	166	48	to	to	PART
fuelectenerg-3675	166	49	calculate	calculate	VERB
fuelectenerg-3675	166	50	calibration	calibration	NOUN
fuelectenerg-3675	166	51	constants	constant	NOUN
fuelectenerg-3675	166	52	for	for	ADP
fuelectenerg-3675	166	53	all	all	DET
fuelectenerg-3675	166	54	pickup	pickup	ADJ
fuelectenerg-3675	166	55	coils	coil	NOUN
fuelectenerg-3675	166	56	.	.	PUNCT
fuelectenerg-3675	167	1	all	all	DET
fuelectenerg-3675	167	2	voltages	voltage	NOUN
fuelectenerg-3675	167	3	have	have	AUX
fuelectenerg-3675	167	4	been	be	AUX
fuelectenerg-3675	167	5	measured	measure	VERB
fuelectenerg-3675	167	6	in	in	ADP
fuelectenerg-3675	167	7	relation	relation	NOUN
fuelectenerg-3675	167	8	to	to	ADP
fuelectenerg-3675	167	9	the	the	DET
fuelectenerg-3675	167	10	ground	ground	NOUN
fuelectenerg-3675	167	11	terminal	terminal	NOUN
fuelectenerg-3675	167	12	of	of	ADP
fuelectenerg-3675	167	13	a	a	DET
fuelectenerg-3675	167	14	data	data	NOUN
fuelectenerg-3675	167	15	acquisition	acquisition	NOUN
fuelectenerg-3675	167	16	card	card	NOUN
fuelectenerg-3675	167	17	.	.	PUNCT
fuelectenerg-3675	168	1	additionally	additionally	ADV
fuelectenerg-3675	168	2	,	,	PUNCT
fuelectenerg-3675	168	3	the	the	DET
fuelectenerg-3675	168	4	voltage	voltage	NOUN
fuelectenerg-3675	168	5	supplied	supply	VERB
fuelectenerg-3675	168	6	to	to	ADP
fuelectenerg-3675	168	7	the	the	DET
fuelectenerg-3675	168	8	large	large	ADJ
fuelectenerg-3675	168	9	solenoid	solenoid	NOUN
fuelectenerg-3675	168	10	ul0	ul0	NOUN
fuelectenerg-3675	168	11	,	,	PUNCT
fuelectenerg-3675	168	12	as	as	ADV
fuelectenerg-3675	168	13	well	well	ADV
fuelectenerg-3675	168	14	as	as	ADP
fuelectenerg-3675	168	15	the	the	DET
fuelectenerg-3675	168	16	electric	electric	ADJ
fuelectenerg-3675	168	17	current	current	NOUN
fuelectenerg-3675	168	18	i	i	PROPN
fuelectenerg-3675	168	19	and	and	CCONJ
fuelectenerg-3675	168	20	the	the	DET
fuelectenerg-3675	168	21	magnetic	magnetic	PROPN
fuelectenerg-3675	168	22	flux	flux	PROPN
fuelectenerg-3675	168	23	density	density	PROPN
fuelectenerg-3675	168	24	b	b	PROPN
fuelectenerg-3675	168	25	(	(	PUNCT
fuelectenerg-3675	168	26	hall	hall	NOUN
fuelectenerg-3675	168	27	sensor	sensor	NOUN
fuelectenerg-3675	168	28	)	)	PUNCT
fuelectenerg-3675	168	29	are	be	AUX
fuelectenerg-3675	168	30	measured	measure	VERB
fuelectenerg-3675	168	31	.	.	PUNCT
fuelectenerg-3675	169	1	thus	thus	ADV
fuelectenerg-3675	169	2	,	,	PUNCT
fuelectenerg-3675	169	3	all	all	DET
fuelectenerg-3675	169	4	quantities	quantity	NOUN
fuelectenerg-3675	169	5	of	of	ADP
fuelectenerg-3675	169	6	interest	interest	NOUN
fuelectenerg-3675	169	7	for	for	ADP
fuelectenerg-3675	169	8	the	the	DET
fuelectenerg-3675	169	9	calibration	calibration	NOUN
fuelectenerg-3675	169	10	of	of	ADP
fuelectenerg-3675	169	11	magnetometer	magnetometer	NOUN
fuelectenerg-3675	169	12	are	be	AUX
fuelectenerg-3675	169	13	measured	measure	VERB
fuelectenerg-3675	169	14	simultaneously	simultaneously	ADV
fuelectenerg-3675	169	15	.	.	PUNCT
fuelectenerg-3675	170	1	measurements	measurement	NOUN
fuelectenerg-3675	170	2	have	have	AUX
fuelectenerg-3675	170	3	been	be	AUX
fuelectenerg-3675	170	4	performed	perform	VERB
fuelectenerg-3675	170	5	at	at	ADP
fuelectenerg-3675	170	6	six	six	NUM
fuelectenerg-3675	170	7	different	different	ADJ
fuelectenerg-3675	170	8	magnetising	magnetising	NOUN
fuelectenerg-3675	170	9	currents	current	NOUN
fuelectenerg-3675	170	10	up	up	ADP
fuelectenerg-3675	170	11	to	to	ADP
fuelectenerg-3675	170	12	around	around	ADP
fuelectenerg-3675	170	13	imax=1.2	imax=1.2	NOUN
fuelectenerg-3675	170	14	a.	a.	NOUN
fuelectenerg-3675	170	15	each	each	DET
fuelectenerg-3675	170	16	signal	signal	NOUN
fuelectenerg-3675	170	17	(	(	PUNCT
fuelectenerg-3675	170	18	its	its	PRON
fuelectenerg-3675	170	19	time	time	NOUN
fuelectenerg-3675	170	20	waveform	waveform	NOUN
fuelectenerg-3675	170	21	)	)	PUNCT
fuelectenerg-3675	170	22	has	have	AUX
fuelectenerg-3675	170	23	been	be	AUX
fuelectenerg-3675	170	24	measured	measure	VERB
fuelectenerg-3675	170	25	1600	1600	NUM
fuelectenerg-3675	170	26	times	time	NOUN
fuelectenerg-3675	170	27	and	and	CCONJ
fuelectenerg-3675	170	28	the	the	DET
fuelectenerg-3675	170	29	averaged	average	VERB
fuelectenerg-3675	170	30	signal	signal	NOUN
fuelectenerg-3675	170	31	has	have	AUX
fuelectenerg-3675	170	32	been	be	AUX
fuelectenerg-3675	170	33	calculated	calculate	VERB
fuelectenerg-3675	170	34	.	.	PUNCT
fuelectenerg-3675	171	1	this	this	PRON
fuelectenerg-3675	171	2	reduces	reduce	VERB
fuelectenerg-3675	171	3	the	the	DET
fuelectenerg-3675	171	4	noise	noise	NOUN
fuelectenerg-3675	171	5	in	in	ADP
fuelectenerg-3675	171	6	all	all	DET
fuelectenerg-3675	171	7	signals	signal	NOUN
fuelectenerg-3675	171	8	to	to	ADP
fuelectenerg-3675	171	9	negligible	negligible	ADJ
fuelectenerg-3675	171	10	levels	level	NOUN
fuelectenerg-3675	171	11	[	[	X
fuelectenerg-3675	171	12	8	8	NUM
fuelectenerg-3675	171	13	]	]	PUNCT
fuelectenerg-3675	171	14	.	.	PUNCT
fuelectenerg-3675	172	1	because	because	SCONJ
fuelectenerg-3675	172	2	this	this	PRON
fuelectenerg-3675	172	3	is	be	AUX
fuelectenerg-3675	172	4	the	the	DET
fuelectenerg-3675	172	5	most	most	ADV
fuelectenerg-3675	172	6	important	important	ADJ
fuelectenerg-3675	172	7	calibration	calibration	NOUN
fuelectenerg-3675	172	8	step	step	NOUN
fuelectenerg-3675	172	9	,	,	PUNCT
fuelectenerg-3675	172	10	it	it	PRON
fuelectenerg-3675	172	11	has	have	AUX
fuelectenerg-3675	172	12	been	be	AUX
fuelectenerg-3675	172	13	repeated	repeat	VERB
fuelectenerg-3675	172	14	five	five	NUM
fuelectenerg-3675	172	15	times	time	NOUN
fuelectenerg-3675	172	16	.	.	PUNCT
fuelectenerg-3675	173	1	finally	finally	ADV
fuelectenerg-3675	173	2	,	,	PUNCT
fuelectenerg-3675	173	3	the	the	DET
fuelectenerg-3675	173	4	mean	mean	ADJ
fuelectenerg-3675	173	5	value	value	NOUN
fuelectenerg-3675	173	6	of	of	ADP
fuelectenerg-3675	173	7	all	all	DET
fuelectenerg-3675	173	8	measurements	measurement	NOUN
fuelectenerg-3675	173	9	has	have	AUX
fuelectenerg-3675	173	10	been	be	AUX
fuelectenerg-3675	173	11	calculated	calculate	VERB
fuelectenerg-3675	173	12	.	.	PUNCT
fuelectenerg-3675	174	1	signals	signal	NOUN
fuelectenerg-3675	174	2	measured	measure	VERB
fuelectenerg-3675	174	3	at	at	ADP
fuelectenerg-3675	174	4	imax=0.39	imax=0.39	NOUN
fuelectenerg-3675	174	5	a	a	PRON
fuelectenerg-3675	174	6	are	be	AUX
fuelectenerg-3675	174	7	presented	present	VERB
fuelectenerg-3675	174	8	in	in	ADP
fuelectenerg-3675	174	9	fig	fig	NOUN
fuelectenerg-3675	174	10	.	.	PUNCT
fuelectenerg-3675	175	1	7	7	X
fuelectenerg-3675	175	2	.	.	X
fuelectenerg-3675	175	3	it	it	PRON
fuelectenerg-3675	175	4	can	can	AUX
fuelectenerg-3675	175	5	be	be	AUX
fuelectenerg-3675	175	6	noticed	notice	VERB
fuelectenerg-3675	175	7	that	that	SCONJ
fuelectenerg-3675	175	8	signals	signal	NOUN
fuelectenerg-3675	175	9	that	that	PRON
fuelectenerg-3675	175	10	represent	represent	VERB
fuelectenerg-3675	175	11	the	the	DET
fuelectenerg-3675	175	12	magnetising	magnetising	PROPN
fuelectenerg-3675	175	13	current	current	NOUN
fuelectenerg-3675	175	14	and	and	CCONJ
fuelectenerg-3675	175	15	the	the	DET
fuelectenerg-3675	175	16	magnetic	magnetic	ADJ
fuelectenerg-3675	175	17	flux	flux	NOUN
fuelectenerg-3675	175	18	density	density	NOUN
fuelectenerg-3675	175	19	are	be	AUX
fuelectenerg-3675	175	20	in	in	ADP
fuelectenerg-3675	175	21	phase	phase	NOUN
fuelectenerg-3675	175	22	,	,	PUNCT
fuelectenerg-3675	175	23	while	while	SCONJ
fuelectenerg-3675	175	24	signal	signal	ADJ
fuelectenerg-3675	175	25	ul1	ul1	PROPN
fuelectenerg-3675	175	26	from	from	ADP
fuelectenerg-3675	175	27	pickup	pickup	PROPN
fuelectenerg-3675	175	28	coil	coil	NOUN
fuelectenerg-3675	175	29	l1	l1	PROPN
fuelectenerg-3675	175	30	is	be	AUX
fuelectenerg-3675	175	31	lagging	lag	VERB
fuelectenerg-3675	175	32	for	for	ADP
fuelectenerg-3675	175	33	π/2	π/2	NUM
fuelectenerg-3675	175	34	.	.	PUNCT
fuelectenerg-3675	176	1	signals	signal	NOUN
fuelectenerg-3675	176	2	ul′2	ul′2	VERB
fuelectenerg-3675	176	3	and	and	CCONJ
fuelectenerg-3675	176	4	ul′3	ul′3	NOUN
fuelectenerg-3675	176	5	from	from	ADP
fuelectenerg-3675	176	6	pickup	pickup	PROPN
fuelectenerg-3675	176	7	coils	coil	NOUN
fuelectenerg-3675	176	8	l′2	l′2	NOUN
fuelectenerg-3675	176	9	and	and	CCONJ
fuelectenerg-3675	176	10	l′3	l′3	NOUN
fuelectenerg-3675	176	11	are	be	AUX
fuelectenerg-3675	176	12	opposite	opposite	ADJ
fuelectenerg-3675	176	13	in	in	ADP
fuelectenerg-3675	176	14	phase	phase	NOUN
fuelectenerg-3675	176	15	with	with	ADP
fuelectenerg-3675	176	16	signal	signal	NOUN
fuelectenerg-3675	176	17	ul1	ul1	PROPN
fuelectenerg-3675	176	18	.	.	PUNCT
fuelectenerg-3675	177	1	the	the	DET
fuelectenerg-3675	177	2	maximum	maximum	NOUN
fuelectenerg-3675	177	3	of	of	ADP
fuelectenerg-3675	177	4	the	the	DET
fuelectenerg-3675	177	5	voltage	voltage	NOUN
fuelectenerg-3675	177	6	induced	induce	VERB
fuelectenerg-3675	177	7	in	in	ADP
fuelectenerg-3675	177	8	a	a	DET
fuelectenerg-3675	177	9	pickup	pickup	NOUN
fuelectenerg-3675	177	10	coil	coil	NOUN
fuelectenerg-3675	177	11	can	can	AUX
fuelectenerg-3675	177	12	be	be	AUX
fuelectenerg-3675	177	13	derived	derive	VERB
fuelectenerg-3675	177	14	as	as	ADP
fuelectenerg-3675	177	15	:	:	PUNCT
fuelectenerg-3675	178	1	max	max	PROPN
fuelectenerg-3675	178	2	max	max	PROPN
fuelectenerg-3675	178	3	0	0	NUM
fuelectenerg-3675	178	4	maxl	maxl	PROPN
fuelectenerg-3675	178	5	l	l	PROPN
fuelectenerg-3675	178	6	lu	lu	PROPN
fuelectenerg-3675	179	1	k	k	PROPN
fuelectenerg-3675	179	2	b	b	PROPN
fuelectenerg-3675	179	3	k	k	PROPN
fuelectenerg-3675	179	4	h	h	NOUN
fuelectenerg-3675	179	5			X
fuelectenerg-3675	179	6			NOUN
fuelectenerg-3675	179	7			NOUN
fuelectenerg-3675	179	8			X
fuelectenerg-3675	179	9	,	,	PUNCT
fuelectenerg-3675	179	10	(	(	PUNCT
fuelectenerg-3675	179	11	6	6	NUM
fuelectenerg-3675	179	12	)	)	PUNCT
fuelectenerg-3675	179	13	calibration	calibration	NOUN
fuelectenerg-3675	179	14	of	of	ADP
fuelectenerg-3675	179	15	ac	ac	PROPN
fuelectenerg-3675	179	16	induction	induction	NOUN
fuelectenerg-3675	179	17	magnetometer	magnetometer	NOUN
fuelectenerg-3675	179	18	621	621	NUM
fuelectenerg-3675	179	19	where	where	SCONJ
fuelectenerg-3675	179	20	kl	kl	PROPN
fuelectenerg-3675	179	21	is	be	AUX
fuelectenerg-3675	179	22	a	a	DET
fuelectenerg-3675	179	23	constant	constant	ADJ
fuelectenerg-3675	179	24	proportional	proportional	NOUN
fuelectenerg-3675	179	25	to	to	ADP
fuelectenerg-3675	179	26	the	the	DET
fuelectenerg-3675	179	27	product	product	NOUN
fuelectenerg-3675	179	28	of	of	ADP
fuelectenerg-3675	179	29	the	the	DET
fuelectenerg-3675	179	30	number	number	NOUN
fuelectenerg-3675	179	31	of	of	ADP
fuelectenerg-3675	179	32	turns	turn	NOUN
fuelectenerg-3675	179	33	and	and	CCONJ
fuelectenerg-3675	179	34	the	the	DET
fuelectenerg-3675	179	35	crosssection	crosssection	NOUN
fuelectenerg-3675	179	36	area	area	NOUN
fuelectenerg-3675	179	37	of	of	ADP
fuelectenerg-3675	179	38	the	the	DET
fuelectenerg-3675	179	39	pickup	pickup	NOUN
fuelectenerg-3675	179	40	coil	coil	NOUN
fuelectenerg-3675	179	41	and	and	CCONJ
fuelectenerg-3675	179	42	ω	ω	PROPN
fuelectenerg-3675	179	43	is	be	AUX
fuelectenerg-3675	179	44	the	the	DET
fuelectenerg-3675	179	45	angular	angular	ADJ
fuelectenerg-3675	179	46	frequency	frequency	NOUN
fuelectenerg-3675	179	47	.	.	PUNCT
fuelectenerg-3675	180	1	since	since	SCONJ
fuelectenerg-3675	180	2	the	the	DET
fuelectenerg-3675	180	3	number	number	NOUN
fuelectenerg-3675	180	4	of	of	ADP
fuelectenerg-3675	180	5	turns	turn	NOUN
fuelectenerg-3675	180	6	are	be	AUX
fuelectenerg-3675	180	7	unknown	unknown	ADJ
fuelectenerg-3675	180	8	for	for	ADP
fuelectenerg-3675	180	9	pickup	pickup	ADJ
fuelectenerg-3675	180	10	coils	coil	NOUN
fuelectenerg-3675	180	11	of	of	ADP
fuelectenerg-3675	180	12	the	the	DET
fuelectenerg-3675	180	13	calibrated	calibrate	VERB
fuelectenerg-3675	180	14	magnetometer	magnetometer	NOUN
fuelectenerg-3675	180	15	,	,	PUNCT
fuelectenerg-3675	180	16	this	this	DET
fuelectenerg-3675	180	17	product	product	NOUN
fuelectenerg-3675	180	18	can	can	AUX
fuelectenerg-3675	180	19	be	be	AUX
fuelectenerg-3675	180	20	calculated	calculate	VERB
fuelectenerg-3675	180	21	from	from	ADP
fuelectenerg-3675	180	22	the	the	DET
fuelectenerg-3675	180	23	measured	measure	VERB
fuelectenerg-3675	180	24	maximums	maximum	NOUN
fuelectenerg-3675	180	25	of	of	ADP
fuelectenerg-3675	180	26	the	the	DET
fuelectenerg-3675	180	27	induced	induced	ADJ
fuelectenerg-3675	180	28	voltage	voltage	NOUN
fuelectenerg-3675	180	29	and	and	CCONJ
fuelectenerg-3675	180	30	the	the	DET
fuelectenerg-3675	180	31	magnetic	magnetic	ADJ
fuelectenerg-3675	180	32	flux	flux	PROPN
fuelectenerg-3675	180	33	density	density	PROPN
fuelectenerg-3675	180	34	.	.	PUNCT
fuelectenerg-3675	181	1	thus	thus	ADV
fuelectenerg-3675	181	2	,	,	PUNCT
fuelectenerg-3675	181	3	the	the	DET
fuelectenerg-3675	181	4	calibration	calibration	NOUN
fuelectenerg-3675	181	5	constant	constant	ADJ
fuelectenerg-3675	181	6	of	of	ADP
fuelectenerg-3675	181	7	the	the	DET
fuelectenerg-3675	181	8	pickup	pickup	NOUN
fuelectenerg-3675	181	9	coil	coil	NOUN
fuelectenerg-3675	181	10	can	can	AUX
fuelectenerg-3675	181	11	be	be	AUX
fuelectenerg-3675	181	12	obtained	obtain	VERB
fuelectenerg-3675	181	13	as	as	ADP
fuelectenerg-3675	181	14	:	:	PUNCT
fuelectenerg-3675	181	15	kl	kl	PART
fuelectenerg-3675	181	16	=	=	NOUN
fuelectenerg-3675	181	17	ulmax	ulmax	ADJ
fuelectenerg-3675	181	18	/	/	SYM
fuelectenerg-3675	181	19	ωbmax	ωbmax	NOUN
fuelectenerg-3675	181	20	.	.	PUNCT
fuelectenerg-3675	182	1	0.00	0.00	NUM
fuelectenerg-3675	182	2	0.02	0.02	NUM
fuelectenerg-3675	182	3	0.04	0.04	NUM
fuelectenerg-3675	182	4	0.06	0.06	NUM
fuelectenerg-3675	182	5	-60	-60	SYM
fuelectenerg-3675	182	6	-40	-40	PROPN
fuelectenerg-3675	182	7	-20	-20	NUM
fuelectenerg-3675	182	8	0	0	NUM
fuelectenerg-3675	182	9	20	20	NUM
fuelectenerg-3675	182	10	40	40	NUM
fuelectenerg-3675	182	11	60	60	NUM
fuelectenerg-3675	182	12	-0.4	-0.4	NUM
fuelectenerg-3675	182	13	-0.3	-0.3	PROPN
fuelectenerg-3675	182	14	-0.2	-0.2	PROPN
fuelectenerg-3675	182	15	-0.1	-0.1	PROPN
fuelectenerg-3675	182	16	0.0	0.0	NUM
fuelectenerg-3675	182	17	0.1	0.1	NUM
fuelectenerg-3675	182	18	0.2	0.2	NUM
fuelectenerg-3675	182	19	0.3	0.3	NUM
fuelectenerg-3675	182	20	0.4	0.4	NUM
fuelectenerg-3675	183	1	-8	-8	NUM
fuelectenerg-3675	184	1	-6	-6	INTJ
fuelectenerg-3675	184	2	-4	-4	INTJ
fuelectenerg-3675	185	1	-2	-2	NOUN
fuelectenerg-3675	185	2	0	0	NUM
fuelectenerg-3675	185	3	2	2	NUM
fuelectenerg-3675	185	4	4	4	NUM
fuelectenerg-3675	185	5	6	6	NUM
fuelectenerg-3675	185	6	8	8	NUM
fuelectenerg-3675	185	7	voltage	voltage	NOUN
fuelectenerg-3675	185	8	current	current	ADJ
fuelectenerg-3675	185	9	magn	magn	NOUN
fuelectenerg-3675	185	10	.	.	PUNCT
fuelectenerg-3675	186	1	flux	flux	PROPN
fuelectenerg-3675	186	2	density	density	PROPN
fuelectenerg-3675	186	3	b	b	PROPN
fuelectenerg-3675	186	4	[	[	PUNCT
fuelectenerg-3675	186	5	m	m	NOUN
fuelectenerg-3675	186	6	t	t	X
fuelectenerg-3675	186	7	]	]	PUNCT
fuelectenerg-3675	187	1	i	i	PRON
fuelectenerg-3675	188	1	[	[	X
fuelectenerg-3675	188	2	a	a	X
fuelectenerg-3675	188	3	]	]	X
fuelectenerg-3675	188	4	u	u	NOUN
fuelectenerg-3675	188	5	l	l	NOUN
fuelectenerg-3675	188	6	0	0	PUNCT
fuelectenerg-3675	188	7	[	[	PUNCT
fuelectenerg-3675	188	8	v	v	X
fuelectenerg-3675	188	9	]	]	PUNCT
fuelectenerg-3675	188	10	t	t	PROPN
fuelectenerg-3675	189	1	[	[	X
fuelectenerg-3675	189	2	s	s	X
fuelectenerg-3675	189	3	]	]	PUNCT
fuelectenerg-3675	189	4	0.00	0.00	NUM
fuelectenerg-3675	189	5	0.01	0.01	NUM
fuelectenerg-3675	189	6	0.02	0.02	NUM
fuelectenerg-3675	189	7	0.03	0.03	NUM
fuelectenerg-3675	189	8	0.04	0.04	NUM
fuelectenerg-3675	189	9	0.05	0.05	NUM
fuelectenerg-3675	189	10	0.06	0.06	NUM
fuelectenerg-3675	189	11	-3	-3	INTJ
fuelectenerg-3675	189	12	-2	-2	INTJ
fuelectenerg-3675	190	1	-1	-1	NOUN
fuelectenerg-3675	190	2	0	0	NUM
fuelectenerg-3675	191	1	1	1	NUM
fuelectenerg-3675	191	2	2	2	NUM
fuelectenerg-3675	191	3	3	3	NUM
fuelectenerg-3675	191	4	u	u	NOUN
fuelectenerg-3675	191	5	l	l	NOUN
fuelectenerg-3675	191	6	1	1	NUM
fuelectenerg-3675	191	7	,	,	PUNCT
fuelectenerg-3675	191	8	u	u	NOUN
fuelectenerg-3675	191	9	l	l	NOUN
fuelectenerg-3675	191	10	'	'	NUM
fuelectenerg-3675	191	11	2	2	NUM
fuelectenerg-3675	191	12	,	,	PUNCT
fuelectenerg-3675	191	13	u	u	NOUN
fuelectenerg-3675	191	14	l	l	NOUN
fuelectenerg-3675	191	15	'	'	NUM
fuelectenerg-3675	191	16	3	3	NUM
fuelectenerg-3675	191	17	[	[	PUNCT
fuelectenerg-3675	191	18	v	v	NOUN
fuelectenerg-3675	191	19	]	]	PUNCT
fuelectenerg-3675	191	20	t	t	NOUN
fuelectenerg-3675	192	1	[	[	X
fuelectenerg-3675	192	2	s	s	X
fuelectenerg-3675	192	3	]	]	X
fuelectenerg-3675	192	4	u	u	NOUN
fuelectenerg-3675	192	5	l1	l1	PROPN
fuelectenerg-3675	192	6	u	u	PROPN
fuelectenerg-3675	192	7	l	l	NOUN
fuelectenerg-3675	192	8	'	'	PART
fuelectenerg-3675	192	9	2	2	NUM
fuelectenerg-3675	192	10	u	u	NOUN
fuelectenerg-3675	192	11	l	l	NOUN
fuelectenerg-3675	192	12	'	'	PUNCT
fuelectenerg-3675	192	13	3	3	NUM
fuelectenerg-3675	192	14	fig	fig	NOUN
fuelectenerg-3675	192	15	.	.	PUNCT
fuelectenerg-3675	193	1	7	7	NUM
fuelectenerg-3675	193	2	calibration	calibration	NOUN
fuelectenerg-3675	193	3	of	of	ADP
fuelectenerg-3675	193	4	pickup	pickup	ADJ
fuelectenerg-3675	193	5	coils	coil	NOUN
fuelectenerg-3675	193	6	measured	measure	VERB
fuelectenerg-3675	193	7	signals	signal	NOUN
fuelectenerg-3675	193	8	table	table	NOUN
fuelectenerg-3675	193	9	1	1	NUM
fuelectenerg-3675	193	10	presents	present	NOUN
fuelectenerg-3675	193	11	results	result	NOUN
fuelectenerg-3675	193	12	of	of	ADP
fuelectenerg-3675	193	13	calibration	calibration	NOUN
fuelectenerg-3675	193	14	of	of	ADP
fuelectenerg-3675	193	15	pickup	pickup	ADJ
fuelectenerg-3675	193	16	coils	coil	NOUN
fuelectenerg-3675	193	17	obtained	obtain	VERB
fuelectenerg-3675	193	18	for	for	ADP
fuelectenerg-3675	193	19	different	different	ADJ
fuelectenerg-3675	193	20	magnetising	magnetising	NOUN
fuelectenerg-3675	193	21	currents	current	NOUN
fuelectenerg-3675	193	22	,	,	PUNCT
fuelectenerg-3675	193	23	containing	contain	VERB
fuelectenerg-3675	193	24	maximums	maximum	NOUN
fuelectenerg-3675	193	25	of	of	ADP
fuelectenerg-3675	193	26	the	the	DET
fuelectenerg-3675	193	27	supply	supply	NOUN
fuelectenerg-3675	193	28	voltage	voltage	NOUN
fuelectenerg-3675	193	29	and	and	CCONJ
fuelectenerg-3675	193	30	electric	electric	ADJ
fuelectenerg-3675	193	31	current	current	NOUN
fuelectenerg-3675	193	32	of	of	ADP
fuelectenerg-3675	193	33	the	the	DET
fuelectenerg-3675	193	34	large	large	ADJ
fuelectenerg-3675	193	35	solenoid	solenoid	NOUN
fuelectenerg-3675	193	36	,	,	PUNCT
fuelectenerg-3675	193	37	maximum	maximum	ADJ
fuelectenerg-3675	193	38	of	of	ADP
fuelectenerg-3675	193	39	the	the	DET
fuelectenerg-3675	193	40	magnetic	magnetic	ADJ
fuelectenerg-3675	193	41	flux	flux	NOUN
fuelectenerg-3675	193	42	density	density	NOUN
fuelectenerg-3675	193	43	measured	measure	VERB
fuelectenerg-3675	193	44	with	with	ADP
fuelectenerg-3675	193	45	hall	hall	PROPN
fuelectenerg-3675	193	46	sensor	sensor	NOUN
fuelectenerg-3675	193	47	,	,	PUNCT
fuelectenerg-3675	193	48	maximum	maximum	NOUN
fuelectenerg-3675	193	49	of	of	ADP
fuelectenerg-3675	193	50	the	the	DET
fuelectenerg-3675	193	51	voltage	voltage	NOUN
fuelectenerg-3675	193	52	induced	induce	VERB
fuelectenerg-3675	193	53	in	in	ADP
fuelectenerg-3675	193	54	the	the	DET
fuelectenerg-3675	193	55	pickup	pickup	NOUN
fuelectenerg-3675	193	56	coil	coil	NOUN
fuelectenerg-3675	193	57	l1	l1	PROPN
fuelectenerg-3675	193	58	and	and	CCONJ
fuelectenerg-3675	193	59	calculated	calculate	VERB
fuelectenerg-3675	193	60	calibration	calibration	NOUN
fuelectenerg-3675	193	61	constants	constant	NOUN
fuelectenerg-3675	193	62	for	for	ADP
fuelectenerg-3675	193	63	all	all	DET
fuelectenerg-3675	193	64	pickup	pickup	ADJ
fuelectenerg-3675	193	65	coils	coil	NOUN
fuelectenerg-3675	193	66	.	.	PUNCT
fuelectenerg-3675	194	1	last	last	ADJ
fuelectenerg-3675	194	2	row	row	NOUN
fuelectenerg-3675	194	3	of	of	ADP
fuelectenerg-3675	194	4	table	table	NOUN
fuelectenerg-3675	194	5	1	1	NUM
fuelectenerg-3675	194	6	gives	give	VERB
fuelectenerg-3675	194	7	averaged	average	VERB
fuelectenerg-3675	194	8	values	value	NOUN
fuelectenerg-3675	194	9	of	of	ADP
fuelectenerg-3675	194	10	the	the	DET
fuelectenerg-3675	194	11	ratio	ratio	NOUN
fuelectenerg-3675	194	12	of	of	ADP
fuelectenerg-3675	194	13	maximums	maximum	NOUN
fuelectenerg-3675	194	14	of	of	ADP
fuelectenerg-3675	194	15	the	the	DET
fuelectenerg-3675	194	16	magnetic	magnetic	ADJ
fuelectenerg-3675	194	17	flux	flux	NOUN
fuelectenerg-3675	194	18	density	density	NOUN
fuelectenerg-3675	194	19	and	and	CCONJ
fuelectenerg-3675	194	20	the	the	DET
fuelectenerg-3675	194	21	magnetising	magnetising	PROPN
fuelectenerg-3675	194	22	current	current	NOUN
fuelectenerg-3675	194	23	,	,	PUNCT
fuelectenerg-3675	194	24	which	which	PRON
fuelectenerg-3675	194	25	is	be	AUX
fuelectenerg-3675	194	26	the	the	DET
fuelectenerg-3675	194	27	calibration	calibration	NOUN
fuelectenerg-3675	194	28	constant	constant	ADJ
fuelectenerg-3675	194	29	of	of	ADP
fuelectenerg-3675	194	30	the	the	DET
fuelectenerg-3675	194	31	large	large	ADJ
fuelectenerg-3675	194	32	solenoid	solenoid	NOUN
fuelectenerg-3675	194	33	l0	l0	NOUN
fuelectenerg-3675	194	34	(	(	PUNCT
fuelectenerg-3675	194	35	step	step	NOUN
fuelectenerg-3675	194	36	two	two	NUM
fuelectenerg-3675	194	37	)	)	PUNCT
fuelectenerg-3675	194	38	and	and	CCONJ
fuelectenerg-3675	194	39	averaged	average	VERB
fuelectenerg-3675	194	40	values	value	NOUN
fuelectenerg-3675	194	41	of	of	ADP
fuelectenerg-3675	194	42	the	the	DET
fuelectenerg-3675	194	43	calibration	calibration	NOUN
fuelectenerg-3675	194	44	constant	constant	ADJ
fuelectenerg-3675	194	45	of	of	ADP
fuelectenerg-3675	194	46	all	all	DET
fuelectenerg-3675	194	47	pickup	pickup	ADJ
fuelectenerg-3675	194	48	coils	coil	NOUN
fuelectenerg-3675	194	49	.	.	PUNCT
fuelectenerg-3675	195	1	622	622	NUM
fuelectenerg-3675	195	2	b.	b.	PROPN
fuelectenerg-3675	195	3	koprivica	koprivica	PROPN
fuelectenerg-3675	195	4	,	,	PUNCT
fuelectenerg-3675	195	5	m.	m.	NOUN
fuelectenerg-3675	195	6	šućurović	šućurović	PROPN
fuelectenerg-3675	195	7	,	,	PUNCT
fuelectenerg-3675	195	8	a.	a.	NOUN
fuelectenerg-3675	195	9	milovanović	milovanović	NOUN
fuelectenerg-3675	195	10	obtained	obtain	VERB
fuelectenerg-3675	195	11	calibration	calibration	NOUN
fuelectenerg-3675	195	12	constant	constant	ADJ
fuelectenerg-3675	195	13	for	for	ADP
fuelectenerg-3675	195	14	the	the	DET
fuelectenerg-3675	195	15	large	large	ADJ
fuelectenerg-3675	195	16	solenoid	solenoid	NOUN
fuelectenerg-3675	195	17	is	be	AUX
fuelectenerg-3675	195	18	in	in	ADP
fuelectenerg-3675	195	19	accordance	accordance	NOUN
fuelectenerg-3675	195	20	with	with	ADP
fuelectenerg-3675	195	21	the	the	DET
fuelectenerg-3675	195	22	result	result	NOUN
fuelectenerg-3675	195	23	given	give	VERB
fuelectenerg-3675	195	24	in	in	ADP
fuelectenerg-3675	195	25	fig	fig	NOUN
fuelectenerg-3675	195	26	.	.	PUNCT
fuelectenerg-3675	196	1	6	6	NUM
fuelectenerg-3675	196	2	.	.	NOUN
fuelectenerg-3675	196	3	table	table	NOUN
fuelectenerg-3675	196	4	1	1	NUM
fuelectenerg-3675	196	5	results	result	NOUN
fuelectenerg-3675	196	6	of	of	ADP
fuelectenerg-3675	196	7	pickup	pickup	ADJ
fuelectenerg-3675	196	8	coils	coil	NOUN
fuelectenerg-3675	196	9	calibration	calibration	NOUN
fuelectenerg-3675	196	10	ul0max	ul0max	PROPN
fuelectenerg-3675	196	11	[	[	X
fuelectenerg-3675	196	12	v	v	X
fuelectenerg-3675	196	13	]	]	X
fuelectenerg-3675	196	14	imax	imax	NOUN
fuelectenerg-3675	196	15	[	[	X
fuelectenerg-3675	196	16	a	a	X
fuelectenerg-3675	196	17	]	]	X
fuelectenerg-3675	196	18	bmax	bmax	NOUN
fuelectenerg-3675	196	19	[	[	X
fuelectenerg-3675	196	20	mt	mt	X
fuelectenerg-3675	196	21	]	]	X
fuelectenerg-3675	196	22	bmax	bmax	PROPN
fuelectenerg-3675	196	23	/	/	SYM
fuelectenerg-3675	196	24	imax	imax	PROPN
fuelectenerg-3675	197	1	[	[	X
fuelectenerg-3675	197	2	mt	mt	PROPN
fuelectenerg-3675	197	3	/	/	SYM
fuelectenerg-3675	197	4	a	a	NOUN
fuelectenerg-3675	197	5	]	]	X
fuelectenerg-3675	197	6	ul1max	ul1max	PROPN
fuelectenerg-3675	197	7	[	[	X
fuelectenerg-3675	197	8	v	v	X
fuelectenerg-3675	197	9	]	]	X
fuelectenerg-3675	197	10	kl1	kl1	NOUN
fuelectenerg-3675	197	11	[	[	X
fuelectenerg-3675	197	12	m2	m2	PROPN
fuelectenerg-3675	197	13	]	]	X
fuelectenerg-3675	197	14	kl′2	kl′2	PROPN
fuelectenerg-3675	197	15	=	=	PRON
fuelectenerg-3675	197	16	kl2	kl2	PROPN
fuelectenerg-3675	197	17	[	[	X
fuelectenerg-3675	197	18	m2	m2	PROPN
fuelectenerg-3675	197	19	]	]	X
fuelectenerg-3675	197	20	kl′3	kl′3	PROPN
fuelectenerg-3675	197	21	=	=	NOUN
fuelectenerg-3675	197	22	kl3	kl3	NOUN
fuelectenerg-3675	198	1	[	[	X
fuelectenerg-3675	198	2	m2	m2	PROPN
fuelectenerg-3675	198	3	]	]	X
fuelectenerg-3675	198	4	1	1	NUM
fuelectenerg-3675	198	5	.	.	NOUN
fuelectenerg-3675	198	6	2	2	NUM
fuelectenerg-3675	198	7	.	.	NOUN
fuelectenerg-3675	198	8	3	3	NUM
fuelectenerg-3675	198	9	.	.	NOUN
fuelectenerg-3675	198	10	4	4	NUM
fuelectenerg-3675	198	11	.	.	NOUN
fuelectenerg-3675	198	12	5	5	NUM
fuelectenerg-3675	198	13	.	.	NOUN
fuelectenerg-3675	198	14	6	6	NUM
fuelectenerg-3675	198	15	.	.	X
fuelectenerg-3675	198	16	31.65	31.65	NUM
fuelectenerg-3675	199	1	63.41	63.41	NUM
fuelectenerg-3675	199	2	95.22	95.22	NUM
fuelectenerg-3675	199	3	127.14	127.14	NUM
fuelectenerg-3675	199	4	159.22	159.22	NUM
fuelectenerg-3675	199	5	191.37	191.37	NUM
fuelectenerg-3675	199	6	0.195	0.195	NUM
fuelectenerg-3675	199	7	0.390	0.390	NUM
fuelectenerg-3675	199	8	0.586	0.586	NUM
fuelectenerg-3675	199	9	0.782	0.782	NUM
fuelectenerg-3675	199	10	0.979	0.979	NUM
fuelectenerg-3675	199	11	1.176	1.176	NUM
fuelectenerg-3675	199	12	3.855	3.855	NUM
fuelectenerg-3675	199	13	7.718	7.718	NUM
fuelectenerg-3675	199	14	11.596	11.596	NUM
fuelectenerg-3675	199	15	15.455	15.455	NUM
fuelectenerg-3675	199	16	19.321	19.321	NUM
fuelectenerg-3675	199	17	23.161	23.161	NUM
fuelectenerg-3675	199	18	19.738	19.738	NUM
fuelectenerg-3675	199	19	19.780	19.780	NUM
fuelectenerg-3675	199	20	19.801	19.801	NUM
fuelectenerg-3675	199	21	19.767	19.767	NUM
fuelectenerg-3675	199	22	19.738	19.738	NUM
fuelectenerg-3675	199	23	19.685	19.685	NUM
fuelectenerg-3675	199	24	1.267	1.267	NUM
fuelectenerg-3675	199	25	2.540	2.540	NUM
fuelectenerg-3675	199	26	3.815	3.815	NUM
fuelectenerg-3675	199	27	5.088	5.088	NUM
fuelectenerg-3675	199	28	6.368	6.368	NUM
fuelectenerg-3675	199	29	7.641	7.641	NUM
fuelectenerg-3675	199	30	1.046	1.046	NUM
fuelectenerg-3675	199	31	1.048	1.048	NUM
fuelectenerg-3675	199	32	1.047	1.047	NUM
fuelectenerg-3675	199	33	1.048	1.048	NUM
fuelectenerg-3675	199	34	1.049	1.049	NUM
fuelectenerg-3675	199	35	1.050	1.050	NUM
fuelectenerg-3675	199	36	1.225	1.225	NUM
fuelectenerg-3675	199	37	1.226	1.226	NUM
fuelectenerg-3675	199	38	1.225	1.225	NUM
fuelectenerg-3675	199	39	1.226	1.226	NUM
fuelectenerg-3675	199	40	1.228	1.228	NUM
fuelectenerg-3675	199	41	1.229	1.229	NUM
fuelectenerg-3675	199	42	1.170	1.170	NUM
fuelectenerg-3675	199	43	1.171	1.171	NUM
fuelectenerg-3675	199	44	1.170	1.170	NUM
fuelectenerg-3675	199	45	1.171	1.171	NUM
fuelectenerg-3675	199	46	1.172	1.172	NUM
fuelectenerg-3675	199	47	1.174	1.174	NUM
fuelectenerg-3675	199	48	average	average	NOUN
fuelectenerg-3675	199	49	19.751	19.751	NUM
fuelectenerg-3675	199	50	1.048	1.048	NUM
fuelectenerg-3675	199	51	1.227	1.227	NUM
fuelectenerg-3675	199	52	1.171	1.171	NUM
fuelectenerg-3675	199	53	4	4	NUM
fuelectenerg-3675	199	54	.	.	PUNCT
fuelectenerg-3675	200	1	discussion	discussion	NOUN
fuelectenerg-3675	200	2	of	of	ADP
fuelectenerg-3675	200	3	results	result	NOUN
fuelectenerg-3675	200	4	point	point	NOUN
fuelectenerg-3675	200	5	of	of	ADP
fuelectenerg-3675	200	6	interest	interest	NOUN
fuelectenerg-3675	200	7	and	and	CCONJ
fuelectenerg-3675	200	8	important	important	ADJ
fuelectenerg-3675	200	9	part	part	NOUN
fuelectenerg-3675	200	10	of	of	ADP
fuelectenerg-3675	200	11	calibration	calibration	NOUN
fuelectenerg-3675	200	12	procedure	procedure	NOUN
fuelectenerg-3675	200	13	is	be	AUX
fuelectenerg-3675	200	14	estimation	estimation	NOUN
fuelectenerg-3675	200	15	of	of	ADP
fuelectenerg-3675	200	16	the	the	DET
fuelectenerg-3675	200	17	uncertainty	uncertainty	NOUN
fuelectenerg-3675	200	18	of	of	ADP
fuelectenerg-3675	200	19	performed	perform	VERB
fuelectenerg-3675	200	20	measurements	measurement	NOUN
fuelectenerg-3675	200	21	[	[	X
fuelectenerg-3675	200	22	11	11	NUM
fuelectenerg-3675	200	23	]	]	PUNCT
fuelectenerg-3675	200	24	.	.	PUNCT
fuelectenerg-3675	201	1	calibration	calibration	NOUN
fuelectenerg-3675	201	2	of	of	ADP
fuelectenerg-3675	201	3	hall	hall	NOUN
fuelectenerg-3675	201	4	sensor	sensor	NOUN
fuelectenerg-3675	201	5	is	be	AUX
fuelectenerg-3675	201	6	found	find	VERB
fuelectenerg-3675	201	7	to	to	PART
fuelectenerg-3675	201	8	be	be	AUX
fuelectenerg-3675	201	9	complex	complex	ADJ
fuelectenerg-3675	201	10	and	and	CCONJ
fuelectenerg-3675	201	11	influenced	influence	VERB
fuelectenerg-3675	201	12	by	by	ADP
fuelectenerg-3675	201	13	many	many	ADJ
fuelectenerg-3675	201	14	variables	variable	NOUN
fuelectenerg-3675	201	15	.	.	PUNCT
fuelectenerg-3675	202	1	also	also	ADV
fuelectenerg-3675	202	2	,	,	PUNCT
fuelectenerg-3675	202	3	the	the	DET
fuelectenerg-3675	202	4	uncertainty	uncertainty	NOUN
fuelectenerg-3675	202	5	of	of	ADP
fuelectenerg-3675	202	6	this	this	DET
fuelectenerg-3675	202	7	calibration	calibration	NOUN
fuelectenerg-3675	202	8	influences	influence	VERB
fuelectenerg-3675	202	9	the	the	DET
fuelectenerg-3675	202	10	uncertainty	uncertainty	NOUN
fuelectenerg-3675	202	11	of	of	ADP
fuelectenerg-3675	202	12	other	other	ADJ
fuelectenerg-3675	202	13	two	two	NUM
fuelectenerg-3675	202	14	calibrations	calibration	NOUN
fuelectenerg-3675	202	15	.	.	PUNCT
fuelectenerg-3675	203	1	therefore	therefore	ADV
fuelectenerg-3675	203	2	,	,	PUNCT
fuelectenerg-3675	203	3	it	it	PRON
fuelectenerg-3675	203	4	is	be	AUX
fuelectenerg-3675	203	5	analysed	analyse	VERB
fuelectenerg-3675	203	6	thoroughly	thoroughly	ADV
fuelectenerg-3675	203	7	in	in	ADP
fuelectenerg-3675	203	8	this	this	DET
fuelectenerg-3675	203	9	section	section	NOUN
fuelectenerg-3675	203	10	.	.	PUNCT
fuelectenerg-3675	204	1	in	in	ADP
fuelectenerg-3675	204	2	order	order	NOUN
fuelectenerg-3675	204	3	to	to	PART
fuelectenerg-3675	204	4	achieve	achieve	VERB
fuelectenerg-3675	204	5	the	the	DET
fuelectenerg-3675	204	6	lowest	low	ADJ
fuelectenerg-3675	204	7	possible	possible	ADJ
fuelectenerg-3675	204	8	uncertainty	uncertainty	NOUN
fuelectenerg-3675	204	9	,	,	PUNCT
fuelectenerg-3675	204	10	the	the	DET
fuelectenerg-3675	204	11	calibration	calibration	NOUN
fuelectenerg-3675	204	12	of	of	ADP
fuelectenerg-3675	204	13	hall	hall	NOUN
fuelectenerg-3675	204	14	sensor	sensor	NOUN
fuelectenerg-3675	204	15	is	be	AUX
fuelectenerg-3675	204	16	repeated	repeat	VERB
fuelectenerg-3675	204	17	with	with	ADP
fuelectenerg-3675	204	18	another	another	DET
fuelectenerg-3675	204	19	data	data	NOUN
fuelectenerg-3675	204	20	acquisition	acquisition	NOUN
fuelectenerg-3675	204	21	card	card	NOUN
fuelectenerg-3675	204	22	(	(	PUNCT
fuelectenerg-3675	204	23	ni	ni	PROPN
fuelectenerg-3675	204	24	9205	9205	NUM
fuelectenerg-3675	204	25	)	)	PUNCT
fuelectenerg-3675	204	26	which	which	PRON
fuelectenerg-3675	204	27	has	have	VERB
fuelectenerg-3675	204	28	adjustable	adjustable	ADJ
fuelectenerg-3675	204	29	voltage	voltage	NOUN
fuelectenerg-3675	204	30	ranges	range	NOUN
fuelectenerg-3675	204	31	and	and	CCONJ
fuelectenerg-3675	204	32	better	well	ADJ
fuelectenerg-3675	204	33	absolute	absolute	ADJ
fuelectenerg-3675	204	34	accuracy	accuracy	NOUN
fuelectenerg-3675	204	35	than	than	ADP
fuelectenerg-3675	204	36	ni	ni	PROPN
fuelectenerg-3675	204	37	usb	usb	PROPN
fuelectenerg-3675	204	38	6009	6009	NUM
fuelectenerg-3675	204	39	.	.	PUNCT
fuelectenerg-3675	205	1	voltage	voltage	NOUN
fuelectenerg-3675	205	2	range	range	NOUN
fuelectenerg-3675	205	3	for	for	ADP
fuelectenerg-3675	205	4	measurement	measurement	NOUN
fuelectenerg-3675	205	5	of	of	ADP
fuelectenerg-3675	205	6	hall	hall	NOUN
fuelectenerg-3675	205	7	sensor	sensor	NOUN
fuelectenerg-3675	205	8	voltage	voltage	NOUN
fuelectenerg-3675	205	9	is	be	AUX
fuelectenerg-3675	205	10	set	set	VERB
fuelectenerg-3675	205	11	to	to	ADP
fuelectenerg-3675	205	12	5	5	NUM
fuelectenerg-3675	205	13	v	v	NOUN
fuelectenerg-3675	205	14	and	and	CCONJ
fuelectenerg-3675	205	15	voltage	voltage	NOUN
fuelectenerg-3675	205	16	range	range	NOUN
fuelectenerg-3675	205	17	for	for	ADP
fuelectenerg-3675	205	18	measurements	measurement	NOUN
fuelectenerg-3675	205	19	of	of	ADP
fuelectenerg-3675	205	20	voltage	voltage	NOUN
fuelectenerg-3675	205	21	at	at	ADP
fuelectenerg-3675	205	22	the	the	DET
fuelectenerg-3675	205	23	ends	end	NOUN
fuelectenerg-3675	205	24	of	of	ADP
fuelectenerg-3675	205	25	shunt	shunt	NOUN
fuelectenerg-3675	205	26	resistor	resistor	NOUN
fuelectenerg-3675	205	27	is	be	AUX
fuelectenerg-3675	205	28	set	set	VERB
fuelectenerg-3675	205	29	to	to	ADP
fuelectenerg-3675	205	30	200	200	NUM
fuelectenerg-3675	205	31	mv	mv	PROPN
fuelectenerg-3675	205	32	in	in	ADP
fuelectenerg-3675	205	33	measurements	measurement	NOUN
fuelectenerg-3675	205	34	made	make	VERB
fuelectenerg-3675	205	35	at	at	ADP
fuelectenerg-3675	205	36	magnetic	magnetic	ADJ
fuelectenerg-3675	205	37	flux	flux	NOUN
fuelectenerg-3675	205	38	density	density	NOUN
fuelectenerg-3675	205	39	of	of	ADP
fuelectenerg-3675	205	40	10	10	NUM
fuelectenerg-3675	205	41	mt	mt	PROPN
fuelectenerg-3675	205	42	.	.	PROPN
fuelectenerg-3675	205	43	hall	hall	PROPN
fuelectenerg-3675	205	44	sensor	sensor	PROPN
fuelectenerg-3675	205	45	sensitivity	sensitivity	NOUN
fuelectenerg-3675	205	46	is	be	AUX
fuelectenerg-3675	205	47	calculated	calculate	VERB
fuelectenerg-3675	205	48	as	as	ADP
fuelectenerg-3675	205	49	:	:	PUNCT
fuelectenerg-3675	205	50	max	max	PROPN
fuelectenerg-3675	205	51	max	max	PROPN
fuelectenerg-3675	205	52	max	max	PROPN
fuelectenerg-3675	205	53	0	0	NUM
fuelectenerg-3675	205	54	1	1	NUM
fuelectenerg-3675	205	55	max	max	PROPN
fuelectenerg-3675	205	56	2.5	2.5	NUM
fuelectenerg-3675	205	57	(	(	PUNCT
fuelectenerg-3675	205	58	2.5)h	2.5)h	NUM
fuelectenerg-3675	205	59	hu	hu	NOUN
fuelectenerg-3675	205	60	u	u	AUX
fuelectenerg-3675	205	61	lr	lr	X
fuelectenerg-3675	205	62	s	s	PROPN
fuelectenerg-3675	205	63	b	b	PROPN
fuelectenerg-3675	205	64	n	n	CCONJ
fuelectenerg-3675	205	65	u	u	NOUN
fuelectenerg-3675	205	66			PROPN
fuelectenerg-3675	205	67			PROPN
fuelectenerg-3675	205	68			NUM
fuelectenerg-3675	206	1			NOUN
fuelectenerg-3675	206	2			NOUN
fuelectenerg-3675	206	3	,	,	PUNCT
fuelectenerg-3675	206	4	(	(	PUNCT
fuelectenerg-3675	206	5	7	7	X
fuelectenerg-3675	206	6	)	)	PUNCT
fuelectenerg-3675	206	7	where	where	SCONJ
fuelectenerg-3675	206	8	:	:	PUNCT
fuelectenerg-3675	206	9	uhmax=2.799	uhmax=2.799	PROPN
fuelectenerg-3675	206	10	v	v	NOUN
fuelectenerg-3675	206	11	is	be	AUX
fuelectenerg-3675	206	12	the	the	DET
fuelectenerg-3675	206	13	maximum	maximum	NOUN
fuelectenerg-3675	206	14	of	of	ADP
fuelectenerg-3675	206	15	hall	hall	NOUN
fuelectenerg-3675	206	16	sensor	sensor	NOUN
fuelectenerg-3675	206	17	voltage	voltage	NOUN
fuelectenerg-3675	206	18	,	,	PUNCT
fuelectenerg-3675	206	19	the	the	DET
fuelectenerg-3675	206	20	quiescent	quiescent	ADJ
fuelectenerg-3675	206	21	output	output	NOUN
fuelectenerg-3675	206	22	voltage	voltage	NOUN
fuelectenerg-3675	206	23	of	of	ADP
fuelectenerg-3675	206	24	hall	hall	NOUN
fuelectenerg-3675	206	25	sensor	sensor	NOUN
fuelectenerg-3675	206	26	is	be	AUX
fuelectenerg-3675	206	27	2.5	2.5	NUM
fuelectenerg-3675	206	28	v	v	NOUN
fuelectenerg-3675	206	29	,	,	PUNCT
fuelectenerg-3675	206	30	bmax	bmax	PROPN
fuelectenerg-3675	206	31	is	be	AUX
fuelectenerg-3675	206	32	the	the	DET
fuelectenerg-3675	206	33	maximum	maximum	NOUN
fuelectenerg-3675	206	34	of	of	ADP
fuelectenerg-3675	206	35	magnetic	magnetic	ADJ
fuelectenerg-3675	206	36	flux	flux	NOUN
fuelectenerg-3675	206	37	density	density	PROPN
fuelectenerg-3675	206	38	,	,	PUNCT
fuelectenerg-3675	206	39	l=340	l=340	PRON
fuelectenerg-3675	206	40	mm	mm	PROPN
fuelectenerg-3675	206	41	is	be	AUX
fuelectenerg-3675	206	42	the	the	DET
fuelectenerg-3675	206	43	length	length	NOUN
fuelectenerg-3675	206	44	of	of	ADP
fuelectenerg-3675	206	45	solenoid	solenoid	NOUN
fuelectenerg-3675	206	46	,	,	PUNCT
fuelectenerg-3675	206	47	r=0.00375	r=0.00375	PROPN
fuelectenerg-3675	206	48	ω	ω	PROPN
fuelectenerg-3675	206	49	is	be	AUX
fuelectenerg-3675	206	50	the	the	DET
fuelectenerg-3675	206	51	shunt	shunt	NOUN
fuelectenerg-3675	206	52	resistance	resistance	NOUN
fuelectenerg-3675	206	53	,	,	PUNCT
fuelectenerg-3675	206	54	μ0=4π·10	μ0=4π·10	PROPN
fuelectenerg-3675	206	55	−7	−7	PROPN
fuelectenerg-3675	206	56	h	h	PROPN
fuelectenerg-3675	206	57	/	/	SYM
fuelectenerg-3675	206	58	m	m	PROPN
fuelectenerg-3675	206	59	is	be	AUX
fuelectenerg-3675	206	60	the	the	DET
fuelectenerg-3675	206	61	magnetic	magnetic	ADJ
fuelectenerg-3675	206	62	permeability	permeability	NOUN
fuelectenerg-3675	206	63	of	of	ADP
fuelectenerg-3675	206	64	vacuum	vacuum	PROPN
fuelectenerg-3675	206	65	(	(	PUNCT
fuelectenerg-3675	206	66	air	air	NOUN
fuelectenerg-3675	206	67	)	)	PUNCT
fuelectenerg-3675	206	68	,	,	PUNCT
fuelectenerg-3675	206	69	n1=190	n1=190	NOUN
fuelectenerg-3675	206	70	is	be	AUX
fuelectenerg-3675	206	71	the	the	DET
fuelectenerg-3675	206	72	number	number	NOUN
fuelectenerg-3675	206	73	of	of	ADP
fuelectenerg-3675	206	74	turns	turn	NOUN
fuelectenerg-3675	206	75	of	of	ADP
fuelectenerg-3675	206	76	solenoid	solenoid	NOUN
fuelectenerg-3675	206	77	and	and	CCONJ
fuelectenerg-3675	206	78	umax=0.05369	umax=0.05369	DET
fuelectenerg-3675	206	79	v	v	NOUN
fuelectenerg-3675	206	80	is	be	AUX
fuelectenerg-3675	206	81	the	the	DET
fuelectenerg-3675	206	82	maximum	maximum	NOUN
fuelectenerg-3675	206	83	of	of	ADP
fuelectenerg-3675	206	84	shunt	shunt	NOUN
fuelectenerg-3675	206	85	voltage	voltage	NOUN
fuelectenerg-3675	206	86	.	.	PUNCT
fuelectenerg-3675	207	1	the	the	DET
fuelectenerg-3675	207	2	combined	combined	ADJ
fuelectenerg-3675	207	3	uncertainty	uncertainty	NOUN
fuelectenerg-3675	207	4	of	of	ADP
fuelectenerg-3675	207	5	sensitivity	sensitivity	NOUN
fuelectenerg-3675	207	6	s	s	VERB
fuelectenerg-3675	207	7	is	be	AUX
fuelectenerg-3675	207	8	calculated	calculate	VERB
fuelectenerg-3675	207	9	according	accord	VERB
fuelectenerg-3675	207	10	to	to	ADP
fuelectenerg-3675	207	11	the	the	DET
fuelectenerg-3675	207	12	sensitivity	sensitivity	NOUN
fuelectenerg-3675	207	13	coefficients	coefficient	NOUN
fuelectenerg-3675	207	14	,	,	PUNCT
fuelectenerg-3675	207	15	which	which	PRON
fuelectenerg-3675	207	16	are	be	AUX
fuelectenerg-3675	207	17	obtained	obtain	VERB
fuelectenerg-3675	207	18	as	as	ADP
fuelectenerg-3675	207	19	partial	partial	ADJ
fuelectenerg-3675	207	20	derivatives	derivative	NOUN
fuelectenerg-3675	207	21	of	of	ADP
fuelectenerg-3675	207	22	sensitivity	sensitivity	NOUN
fuelectenerg-3675	207	23	s	s	AUX
fuelectenerg-3675	207	24	expressed	express	VERB
fuelectenerg-3675	207	25	by	by	ADP
fuelectenerg-3675	207	26	(	(	PUNCT
fuelectenerg-3675	207	27	7	7	NUM
fuelectenerg-3675	207	28	)	)	PUNCT
fuelectenerg-3675	207	29	,	,	PUNCT
fuelectenerg-3675	207	30	and	and	CCONJ
fuelectenerg-3675	207	31	absolute	absolute	ADJ
fuelectenerg-3675	207	32	uncertainties	uncertainty	NOUN
fuelectenerg-3675	207	33	of	of	ADP
fuelectenerg-3675	207	34	each	each	DET
fuelectenerg-3675	207	35	independent	independent	ADJ
fuelectenerg-3675	207	36	variable	variable	NOUN
fuelectenerg-3675	207	37	in	in	ADP
fuelectenerg-3675	207	38	(	(	PUNCT
fuelectenerg-3675	207	39	7	7	NUM
fuelectenerg-3675	207	40	)	)	PUNCT
fuelectenerg-3675	207	41	[	[	X
fuelectenerg-3675	207	42	11	11	NUM
fuelectenerg-3675	207	43	,	,	PUNCT
fuelectenerg-3675	207	44	12	12	NUM
fuelectenerg-3675	207	45	]	]	PUNCT
fuelectenerg-3675	207	46	,	,	PUNCT
fuelectenerg-3675	207	47	as	as	ADP
fuelectenerg-3675	207	48	:	:	PUNCT
fuelectenerg-3675	207	49	calibration	calibration	NOUN
fuelectenerg-3675	207	50	of	of	ADP
fuelectenerg-3675	207	51	ac	ac	PROPN
fuelectenerg-3675	207	52	induction	induction	NOUN
fuelectenerg-3675	207	53	magnetometer	magnetometer	NOUN
fuelectenerg-3675	207	54	623	623	NUM
fuelectenerg-3675	207	55			NOUN
fuelectenerg-3675	207	56			PROPN
fuelectenerg-3675	207	57	2	2	NUM
fuelectenerg-3675	207	58	2	2	NUM
fuelectenerg-3675	207	59	2	2	NUM
fuelectenerg-3675	207	60	,	,	PUNCT
fuelectenerg-3675	207	61	1	1	NUM
fuelectenerg-3675	207	62	1	1	NUM
fuelectenerg-3675	208	1	i	i	PRON
fuelectenerg-3675	208	2	i	i	PRON
fuelectenerg-3675	208	3	s	s	VERB
fuelectenerg-3675	208	4	s	s	PROPN
fuelectenerg-3675	208	5	c	c	NOUN
fuelectenerg-3675	208	6	b	b	PROPN
fuelectenerg-3675	208	7	x	x	SYM
fuelectenerg-3675	208	8	x	x	SYM
fuelectenerg-3675	208	9	ii	ii	VERB
fuelectenerg-3675	209	1	i	i	PRON
fuelectenerg-3675	209	2	s	s	VERB
fuelectenerg-3675	209	3	u	u	NOUN
fuelectenerg-3675	209	4	s	s	PROPN
fuelectenerg-3675	209	5	u	u	NOUN
fuelectenerg-3675	209	6	u	u	NOUN
fuelectenerg-3675	209	7	x	x	NOUN
fuelectenerg-3675	209	8			NUM
fuelectenerg-3675	210	1			NUM
fuelectenerg-3675	210	2			NOUN
fuelectenerg-3675	210	3			NOUN
fuelectenerg-3675	210	4			PROPN
fuelectenerg-3675	210	5			PUNCT
fuelectenerg-3675	211	1			PROPN
fuelectenerg-3675	211	2			ADJ
fuelectenerg-3675	211	3			NOUN
fuelectenerg-3675	211	4			X
fuelectenerg-3675	211	5			X
fuelectenerg-3675	211	6	,	,	PUNCT
fuelectenerg-3675	211	7	(	(	PUNCT
fuelectenerg-3675	211	8	8)	8)	NUM
fuelectenerg-3675	211	9	where	where	SCONJ
fuelectenerg-3675	211	10	xi{uhmax	xi{uhmax	PROPN
fuelectenerg-3675	211	11	,	,	PUNCT
fuelectenerg-3675	211	12	l	l	NOUN
fuelectenerg-3675	211	13	,	,	PUNCT
fuelectenerg-3675	211	14	r	r	NOUN
fuelectenerg-3675	211	15	,	,	PUNCT
fuelectenerg-3675	211	16	n1	n1	NOUN
fuelectenerg-3675	211	17	,	,	PUNCT
fuelectenerg-3675	211	18	umax	umax	ADJ
fuelectenerg-3675	211	19	}	}	PUNCT
fuelectenerg-3675	211	20	,	,	PUNCT
fuelectenerg-3675	211	21	uxi=s/xiub	uxi=s/xiub	NOUN
fuelectenerg-3675	211	22	,	,	PUNCT
fuelectenerg-3675	211	23	xi	xi	NUM
fuelectenerg-3675	211	24	and	and	CCONJ
fuelectenerg-3675	211	25	ub	ub	ADP
fuelectenerg-3675	211	26	,	,	PUNCT
fuelectenerg-3675	211	27	xi	xi	X
fuelectenerg-3675	211	28	is	be	AUX
fuelectenerg-3675	211	29	a	a	DET
fuelectenerg-3675	211	30	type	type	NOUN
fuelectenerg-3675	211	31	b	b	NOUN
fuelectenerg-3675	211	32	standard	standard	ADJ
fuelectenerg-3675	211	33	uncertainty	uncertainty	NOUN
fuelectenerg-3675	211	34	evaluated	evaluate	VERB
fuelectenerg-3675	211	35	as	as	ADP
fuelectenerg-3675	211	36	,	,	PUNCT
fuelectenerg-3675	211	37	3	3	NUM
fuelectenerg-3675	211	38	i	i	PRON
fuelectenerg-3675	211	39	ib	ib	VERB
fuelectenerg-3675	211	40	x	x	PUNCT
fuelectenerg-3675	211	41	xu	xu	PROPN
fuelectenerg-3675	211	42	u	u	X
fuelectenerg-3675	211	43	or	or	CCONJ
fuelectenerg-3675	211	44	,	,	PUNCT
fuelectenerg-3675	211	45	1.960	1.960	NUM
fuelectenerg-3675	211	46	i	i	NOUN
fuelectenerg-3675	211	47	ib	ib	VERB
fuelectenerg-3675	211	48	x	x	PUNCT
fuelectenerg-3675	211	49	xu	xu	PROPN
fuelectenerg-3675	211	50	u	u	PROPN
fuelectenerg-3675	211	51	for	for	ADP
fuelectenerg-3675	211	52	a	a	DET
fuelectenerg-3675	211	53	rectangular	rectangular	ADJ
fuelectenerg-3675	211	54	distribution	distribution	NOUN
fuelectenerg-3675	211	55	or	or	CCONJ
fuelectenerg-3675	211	56	a	a	DET
fuelectenerg-3675	211	57	normal	normal	ADJ
fuelectenerg-3675	211	58	distribution	distribution	NOUN
fuelectenerg-3675	211	59	with	with	ADP
fuelectenerg-3675	211	60	the	the	DET
fuelectenerg-3675	211	61	confidence	confidence	NOUN
fuelectenerg-3675	211	62	level	level	NOUN
fuelectenerg-3675	211	63	of	of	ADP
fuelectenerg-3675	211	64	95	95	NUM
fuelectenerg-3675	211	65	%	%	NOUN
fuelectenerg-3675	211	66	,	,	PUNCT
fuelectenerg-3675	211	67	respectively	respectively	ADV
fuelectenerg-3675	211	68	.	.	PUNCT
fuelectenerg-3675	212	1	sensitivity	sensitivity	NOUN
fuelectenerg-3675	212	2	coefficients	coefficient	NOUN
fuelectenerg-3675	212	3	are	be	AUX
fuelectenerg-3675	212	4	calculated	calculate	VERB
fuelectenerg-3675	212	5	using	use	VERB
fuelectenerg-3675	212	6	values	value	NOUN
fuelectenerg-3675	212	7	of	of	ADP
fuelectenerg-3675	212	8	uhmax	uhmax	PROPN
fuelectenerg-3675	212	9	,	,	PUNCT
fuelectenerg-3675	212	10	l	l	NOUN
fuelectenerg-3675	212	11	,	,	PUNCT
fuelectenerg-3675	212	12	r	r	NOUN
fuelectenerg-3675	212	13	,	,	PUNCT
fuelectenerg-3675	212	14	n1	n1	NOUN
fuelectenerg-3675	212	15	,	,	PUNCT
fuelectenerg-3675	212	16	μ0	μ0	PROPN
fuelectenerg-3675	212	17	and	and	CCONJ
fuelectenerg-3675	212	18	umax	umax	VERB
fuelectenerg-3675	212	19	.	.	PUNCT
fuelectenerg-3675	213	1	their	their	PRON
fuelectenerg-3675	213	2	values	value	NOUN
fuelectenerg-3675	213	3	are	be	AUX
fuelectenerg-3675	213	4	given	give	VERB
fuelectenerg-3675	213	5	in	in	ADP
fuelectenerg-3675	213	6	table	table	NOUN
fuelectenerg-3675	213	7	2	2	NUM
fuelectenerg-3675	213	8	.	.	PUNCT
fuelectenerg-3675	213	9	absolute	absolute	ADJ
fuelectenerg-3675	213	10	uncertainties	uncertainty	NOUN
fuelectenerg-3675	213	11	of	of	ADP
fuelectenerg-3675	213	12	voltages	voltage	NOUN
fuelectenerg-3675	213	13	are	be	AUX
fuelectenerg-3675	213	14	calculated	calculate	VERB
fuelectenerg-3675	213	15	according	accord	VERB
fuelectenerg-3675	213	16	to	to	ADP
fuelectenerg-3675	213	17	the	the	DET
fuelectenerg-3675	213	18	specification	specification	NOUN
fuelectenerg-3675	213	19	for	for	ADP
fuelectenerg-3675	213	20	ni	ni	PROPN
fuelectenerg-3675	213	21	9205	9205	NUM
fuelectenerg-3675	213	22	given	give	VERB
fuelectenerg-3675	213	23	by	by	ADP
fuelectenerg-3675	213	24	the	the	DET
fuelectenerg-3675	213	25	manufacturer	manufacturer	NOUN
fuelectenerg-3675	214	1	[	[	X
fuelectenerg-3675	214	2	13	13	NUM
fuelectenerg-3675	214	3	]	]	PUNCT
fuelectenerg-3675	214	4	,	,	PUNCT
fuelectenerg-3675	214	5	taking	take	VERB
fuelectenerg-3675	214	6	into	into	ADP
fuelectenerg-3675	214	7	account	account	NOUN
fuelectenerg-3675	214	8	three	three	NUM
fuelectenerg-3675	214	9	components	component	NOUN
fuelectenerg-3675	214	10	of	of	ADP
fuelectenerg-3675	214	11	error	error	NOUN
fuelectenerg-3675	214	12	:	:	PUNCT
fuelectenerg-3675	214	13	error	error	NOUN
fuelectenerg-3675	214	14	of	of	ADP
fuelectenerg-3675	214	15	full	full	ADJ
fuelectenerg-3675	214	16	scale	scale	NOUN
fuelectenerg-3675	214	17	,	,	PUNCT
fuelectenerg-3675	214	18	error	error	NOUN
fuelectenerg-3675	214	19	of	of	ADP
fuelectenerg-3675	214	20	reading	reading	NOUN
fuelectenerg-3675	214	21	and	and	CCONJ
fuelectenerg-3675	214	22	noise	noise	NOUN
fuelectenerg-3675	214	23	error	error	NOUN
fuelectenerg-3675	214	24	.	.	PUNCT
fuelectenerg-3675	215	1	the	the	DET
fuelectenerg-3675	215	2	absolute	absolute	ADJ
fuelectenerg-3675	215	3	uncertainty	uncertainty	NOUN
fuelectenerg-3675	215	4	of	of	ADP
fuelectenerg-3675	215	5	the	the	DET
fuelectenerg-3675	215	6	length	length	NOUN
fuelectenerg-3675	215	7	of	of	ADP
fuelectenerg-3675	215	8	solenoid	solenoid	NOUN
fuelectenerg-3675	215	9	is	be	AUX
fuelectenerg-3675	215	10	taken	take	VERB
fuelectenerg-3675	215	11	as	as	ADP
fuelectenerg-3675	215	12	one	one	NUM
fuelectenerg-3675	215	13	half	half	NOUN
fuelectenerg-3675	215	14	of	of	ADP
fuelectenerg-3675	215	15	measuring	measure	VERB
fuelectenerg-3675	215	16	unit	unit	NOUN
fuelectenerg-3675	215	17	.	.	PUNCT
fuelectenerg-3675	216	1	the	the	DET
fuelectenerg-3675	216	2	absolute	absolute	ADJ
fuelectenerg-3675	216	3	uncertainty	uncertainty	NOUN
fuelectenerg-3675	216	4	of	of	ADP
fuelectenerg-3675	216	5	the	the	DET
fuelectenerg-3675	216	6	resistance	resistance	NOUN
fuelectenerg-3675	216	7	is	be	AUX
fuelectenerg-3675	216	8	given	give	VERB
fuelectenerg-3675	216	9	by	by	ADP
fuelectenerg-3675	216	10	the	the	DET
fuelectenerg-3675	216	11	manufacturer	manufacturer	NOUN
fuelectenerg-3675	216	12	as	as	ADP
fuelectenerg-3675	216	13	0.5	0.5	NUM
fuelectenerg-3675	216	14	%	%	NOUN
fuelectenerg-3675	216	15	of	of	ADP
fuelectenerg-3675	216	16	its	its	PRON
fuelectenerg-3675	216	17	rated	rate	VERB
fuelectenerg-3675	216	18	value	value	NOUN
fuelectenerg-3675	216	19	.	.	PUNCT
fuelectenerg-3675	217	1	the	the	DET
fuelectenerg-3675	217	2	absolute	absolute	ADJ
fuelectenerg-3675	217	3	uncertainty	uncertainty	NOUN
fuelectenerg-3675	217	4	of	of	ADP
fuelectenerg-3675	217	5	the	the	DET
fuelectenerg-3675	217	6	number	number	NOUN
fuelectenerg-3675	217	7	of	of	ADP
fuelectenerg-3675	217	8	turns	turn	NOUN
fuelectenerg-3675	217	9	is	be	AUX
fuelectenerg-3675	217	10	equal	equal	ADJ
fuelectenerg-3675	217	11	to	to	ADP
fuelectenerg-3675	217	12	one	one	NUM
fuelectenerg-3675	217	13	turn	turn	NOUN
fuelectenerg-3675	217	14	.	.	PUNCT
fuelectenerg-3675	218	1	all	all	DET
fuelectenerg-3675	218	2	values	value	NOUN
fuelectenerg-3675	218	3	are	be	AUX
fuelectenerg-3675	218	4	given	give	VERB
fuelectenerg-3675	218	5	in	in	ADP
fuelectenerg-3675	218	6	table	table	NOUN
fuelectenerg-3675	218	7	2	2	NUM
fuelectenerg-3675	218	8	.	.	X
fuelectenerg-3675	218	9	rectangular	rectangular	ADJ
fuelectenerg-3675	218	10	distribution	distribution	NOUN
fuelectenerg-3675	218	11	is	be	AUX
fuelectenerg-3675	218	12	assumed	assume	VERB
fuelectenerg-3675	218	13	for	for	ADP
fuelectenerg-3675	218	14	voltages	voltage	NOUN
fuelectenerg-3675	218	15	and	and	CCONJ
fuelectenerg-3675	218	16	resistance	resistance	NOUN
fuelectenerg-3675	218	17	with	with	ADP
fuelectenerg-3675	218	18	coefficient	coefficient	NOUN
fuelectenerg-3675	218	19	of	of	ADP
fuelectenerg-3675	218	20	division	division	NOUN
fuelectenerg-3675	218	21	3	3	NUM
fuelectenerg-3675	218	22	and	and	CCONJ
fuelectenerg-3675	218	23	the	the	DET
fuelectenerg-3675	218	24	normal	normal	ADJ
fuelectenerg-3675	218	25	distribution	distribution	NOUN
fuelectenerg-3675	218	26	is	be	AUX
fuelectenerg-3675	218	27	assumed	assume	VERB
fuelectenerg-3675	218	28	in	in	ADP
fuelectenerg-3675	218	29	the	the	DET
fuelectenerg-3675	218	30	case	case	NOUN
fuelectenerg-3675	218	31	of	of	ADP
fuelectenerg-3675	218	32	length	length	NOUN
fuelectenerg-3675	218	33	and	and	CCONJ
fuelectenerg-3675	218	34	number	number	NOUN
fuelectenerg-3675	218	35	of	of	ADP
fuelectenerg-3675	218	36	turns	turn	NOUN
fuelectenerg-3675	218	37	with	with	ADP
fuelectenerg-3675	218	38	coefficient	coefficient	NOUN
fuelectenerg-3675	218	39	of	of	ADP
fuelectenerg-3675	218	40	division	division	NOUN
fuelectenerg-3675	218	41	1.96	1.96	NUM
fuelectenerg-3675	218	42	(	(	PUNCT
fuelectenerg-3675	218	43	confidence	confidence	NOUN
fuelectenerg-3675	218	44	level	level	NOUN
fuelectenerg-3675	218	45	of	of	ADP
fuelectenerg-3675	218	46	95	95	NUM
fuelectenerg-3675	218	47	%	%	NOUN
fuelectenerg-3675	218	48	at	at	ADP
fuelectenerg-3675	218	49	infinite	infinite	ADJ
fuelectenerg-3675	218	50	degrees	degree	NOUN
fuelectenerg-3675	218	51	of	of	ADP
fuelectenerg-3675	218	52	freedom	freedom	NOUN
fuelectenerg-3675	218	53	)	)	PUNCT
fuelectenerg-3675	218	54	.	.	PUNCT
fuelectenerg-3675	219	1	its	its	PRON
fuelectenerg-3675	219	2	absolute	absolute	ADJ
fuelectenerg-3675	219	3	value	value	NOUN
fuelectenerg-3675	219	4	is	be	AUX
fuelectenerg-3675	219	5	0.174	0.174	NUM
fuelectenerg-3675	219	6	v	v	NOUN
fuelectenerg-3675	219	7	/	/	SYM
fuelectenerg-3675	219	8	t	t	PROPN
fuelectenerg-3675	219	9	and	and	CCONJ
fuelectenerg-3675	219	10	its	its	PRON
fuelectenerg-3675	219	11	relative	relative	ADJ
fuelectenerg-3675	219	12	value	value	NOUN
fuelectenerg-3675	219	13	is	be	AUX
fuelectenerg-3675	219	14	0.58	0.58	NUM
fuelectenerg-3675	219	15	%	%	NOUN
fuelectenerg-3675	219	16	.	.	PUNCT
fuelectenerg-3675	220	1	therefore	therefore	ADV
fuelectenerg-3675	220	2	,	,	PUNCT
fuelectenerg-3675	220	3	standard	standard	ADJ
fuelectenerg-3675	220	4	uncertainty	uncertainty	NOUN
fuelectenerg-3675	220	5	is	be	AUX
fuelectenerg-3675	220	6	0.58	0.58	NUM
fuelectenerg-3675	220	7	%	%	NOUN
fuelectenerg-3675	220	8	.	.	PUNCT
fuelectenerg-3675	221	1	moreover	moreover	ADV
fuelectenerg-3675	221	2	,	,	PUNCT
fuelectenerg-3675	221	3	correction	correction	NOUN
fuelectenerg-3675	221	4	factor	factor	NOUN
fuelectenerg-3675	221	5	k=2	k=2	PROPN
fuelectenerg-3675	221	6	can	can	AUX
fuelectenerg-3675	221	7	be	be	AUX
fuelectenerg-3675	221	8	used	use	VERB
fuelectenerg-3675	221	9	for	for	ADP
fuelectenerg-3675	221	10	calculation	calculation	NOUN
fuelectenerg-3675	221	11	of	of	ADP
fuelectenerg-3675	221	12	expanded	expand	VERB
fuelectenerg-3675	221	13	uncertainty	uncertainty	NOUN
fuelectenerg-3675	221	14	.	.	PUNCT
fuelectenerg-3675	222	1	in	in	ADP
fuelectenerg-3675	222	2	such	such	DET
fuelectenerg-3675	222	3	a	a	DET
fuelectenerg-3675	222	4	case	case	NOUN
fuelectenerg-3675	222	5	,	,	PUNCT
fuelectenerg-3675	222	6	the	the	DET
fuelectenerg-3675	222	7	confidence	confidence	NOUN
fuelectenerg-3675	222	8	level	level	NOUN
fuelectenerg-3675	222	9	is	be	AUX
fuelectenerg-3675	222	10	around	around	ADV
fuelectenerg-3675	222	11	95	95	NUM
fuelectenerg-3675	222	12	%	%	NOUN
fuelectenerg-3675	222	13	and	and	CCONJ
fuelectenerg-3675	222	14	expanded	expand	VERB
fuelectenerg-3675	222	15	uncertainty	uncertainty	NOUN
fuelectenerg-3675	222	16	is	be	AUX
fuelectenerg-3675	222	17	0.35	0.35	NUM
fuelectenerg-3675	222	18	v	v	NOUN
fuelectenerg-3675	222	19	/	/	SYM
fuelectenerg-3675	222	20	t	t	PROPN
fuelectenerg-3675	222	21	or	or	CCONJ
fuelectenerg-3675	222	22	1.17	1.17	NUM
fuelectenerg-3675	222	23	%	%	NOUN
fuelectenerg-3675	222	24	.	.	PUNCT
fuelectenerg-3675	223	1	finally	finally	ADV
fuelectenerg-3675	223	2	,	,	PUNCT
fuelectenerg-3675	223	3	the	the	DET
fuelectenerg-3675	223	4	result	result	NOUN
fuelectenerg-3675	223	5	of	of	ADP
fuelectenerg-3675	223	6	measurement	measurement	NOUN
fuelectenerg-3675	223	7	of	of	ADP
fuelectenerg-3675	223	8	hall	hall	NOUN
fuelectenerg-3675	223	9	sensor	sensor	NOUN
fuelectenerg-3675	223	10	sensitivity	sensitivity	NOUN
fuelectenerg-3675	223	11	can	can	AUX
fuelectenerg-3675	223	12	be	be	AUX
fuelectenerg-3675	223	13	reported	report	VERB
fuelectenerg-3675	223	14	as	as	ADP
fuelectenerg-3675	223	15	:	:	PUNCT
fuelectenerg-3675	223	16	29.77	29.77	NUM
fuelectenerg-3675	223	17	v	v	ADP
fuelectenerg-3675	223	18	t	t	PROPN
fuelectenerg-3675	223	19	0.35	0.35	NUM
fuelectenerg-3675	223	20	v	v	NOUN
fuelectenerg-3675	223	21	ts	ts	ADP
fuelectenerg-3675	223	22			PROPN
fuelectenerg-3675	223	23			PROPN
fuelectenerg-3675	223	24	.	.	PUNCT
fuelectenerg-3675	224	1	(	(	PUNCT
fuelectenerg-3675	224	2	9	9	X
fuelectenerg-3675	224	3	)	)	PUNCT
fuelectenerg-3675	224	4	table	table	NOUN
fuelectenerg-3675	224	5	2	2	NUM
fuelectenerg-3675	224	6	type	type	NOUN
fuelectenerg-3675	224	7	b	b	NOUN
fuelectenerg-3675	224	8	uncertainty	uncertainty	NOUN
fuelectenerg-3675	224	9	for	for	ADP
fuelectenerg-3675	224	10	hall	hall	NOUN
fuelectenerg-3675	224	11	sensor	sensor	NOUN
fuelectenerg-3675	224	12	calibration	calibration	NOUN
fuelectenerg-3675	224	13	at	at	ADP
fuelectenerg-3675	224	14	10	10	NUM
fuelectenerg-3675	224	15	mt	mt	PROPN
fuelectenerg-3675	224	16	variable	variable	ADJ
fuelectenerg-3675	224	17	absolute	absolute	ADJ
fuelectenerg-3675	224	18	uncertainty	uncertainty	NOUN
fuelectenerg-3675	224	19	sensitivity	sensitivity	NOUN
fuelectenerg-3675	224	20	coefficient	coefficient	NOUN
fuelectenerg-3675	224	21	distribution	distribution	NOUN
fuelectenerg-3675	224	22	absolute	absolute	ADJ
fuelectenerg-3675	224	23	standard	standard	ADJ
fuelectenerg-3675	224	24	uncertainty	uncertainty	NOUN
fuelectenerg-3675	224	25	ub	ub	VERB
fuelectenerg-3675	224	26	[	[	X
fuelectenerg-3675	224	27	v	v	NOUN
fuelectenerg-3675	224	28	/	/	SYM
fuelectenerg-3675	224	29	t	t	NOUN
fuelectenerg-3675	224	30	]	]	PUNCT
fuelectenerg-3675	224	31	relative	relative	ADJ
fuelectenerg-3675	224	32	uncertainty	uncertainty	NOUN
fuelectenerg-3675	225	1	[	[	X
fuelectenerg-3675	225	2	%	%	X
fuelectenerg-3675	225	3	]	]	X
fuelectenerg-3675	225	4	uhmax	uhmax	VERB
fuelectenerg-3675	225	5	0.002138	0.002138	NUM
fuelectenerg-3675	225	6	v	v	NUM
fuelectenerg-3675	225	7	99.46	99.46	NUM
fuelectenerg-3675	225	8	1	1	NUM
fuelectenerg-3675	225	9	/	/	SYM
fuelectenerg-3675	225	10	t	t	NOUN
fuelectenerg-3675	225	11	rectangular	rectangular	NOUN
fuelectenerg-3675	225	12	0.12277	0.12277	NUM
fuelectenerg-3675	225	13	0.412	0.412	NUM
fuelectenerg-3675	225	14	l	l	NOUN
fuelectenerg-3675	225	15	0.5·10−3	0.5·10−3	X
fuelectenerg-3675	225	16	m	m	PROPN
fuelectenerg-3675	225	17	87.555	87.555	NUM
fuelectenerg-3675	225	18	v	v	NOUN
fuelectenerg-3675	225	19	/	/	SYM
fuelectenerg-3675	225	20	tm	tm	NOUN
fuelectenerg-3675	225	21	normal	normal	ADJ
fuelectenerg-3675	225	22	(	(	PUNCT
fuelectenerg-3675	225	23	95	95	NUM
fuelectenerg-3675	225	24	%	%	NOUN
fuelectenerg-3675	225	25	)	)	PUNCT
fuelectenerg-3675	225	26	0.02233	0.02233	NUM
fuelectenerg-3675	225	27	0.075	0.075	NUM
fuelectenerg-3675	225	28	r	r	NOUN
fuelectenerg-3675	225	29	0.01875·10−3	0.01875·10−3	NUM
fuelectenerg-3675	225	30	ω	ω	NOUN
fuelectenerg-3675	225	31	7938.32	7938.32	NUM
fuelectenerg-3675	225	32	v	v	NOUN
fuelectenerg-3675	225	33	/	/	SYM
fuelectenerg-3675	225	34	tω	tω	NOUN
fuelectenerg-3675	225	35	rectangular	rectangular	VERB
fuelectenerg-3675	225	36	0.08593	0.08593	NUM
fuelectenerg-3675	225	37	0.289	0.289	NUM
fuelectenerg-3675	225	38	n1	n1	ADJ
fuelectenerg-3675	225	39	1	1	NUM
fuelectenerg-3675	225	40	−0.1567	−0.1567	NUM
fuelectenerg-3675	225	41	v	v	NOUN
fuelectenerg-3675	225	42	/	/	SYM
fuelectenerg-3675	225	43	t	t	NOUN
fuelectenerg-3675	225	44	normal	normal	ADJ
fuelectenerg-3675	225	45	(	(	PUNCT
fuelectenerg-3675	225	46	95	95	NUM
fuelectenerg-3675	225	47	%	%	NOUN
fuelectenerg-3675	225	48	)	)	PUNCT
fuelectenerg-3675	225	49	0.07994	0.07994	NUM
fuelectenerg-3675	226	1	0.268	0.268	NUM
fuelectenerg-3675	226	2	umax	umax	ADJ
fuelectenerg-3675	226	3	0.08953·10−3	0.08953·10−3	PROPN
fuelectenerg-3675	226	4	v	v	ADJ
fuelectenerg-3675	226	5	−554.455	−554.455	NOUN
fuelectenerg-3675	226	6	1	1	NUM
fuelectenerg-3675	226	7	/	/	SYM
fuelectenerg-3675	226	8	t	t	NOUN
fuelectenerg-3675	226	9	rectangular	rectangular	VERB
fuelectenerg-3675	226	10	0.02866	0.02866	NUM
fuelectenerg-3675	226	11	0.096	0.096	NUM
fuelectenerg-3675	226	12	the	the	DET
fuelectenerg-3675	226	13	main	main	ADJ
fuelectenerg-3675	226	14	contribution	contribution	NOUN
fuelectenerg-3675	226	15	to	to	ADP
fuelectenerg-3675	226	16	the	the	DET
fuelectenerg-3675	226	17	measurement	measurement	NOUN
fuelectenerg-3675	226	18	uncertainty	uncertainty	NOUN
fuelectenerg-3675	226	19	comes	come	VERB
fuelectenerg-3675	226	20	from	from	ADP
fuelectenerg-3675	226	21	the	the	DET
fuelectenerg-3675	226	22	measurement	measurement	NOUN
fuelectenerg-3675	226	23	of	of	ADP
fuelectenerg-3675	226	24	output	output	NOUN
fuelectenerg-3675	226	25	voltage	voltage	NOUN
fuelectenerg-3675	226	26	of	of	ADP
fuelectenerg-3675	226	27	hall	hall	NOUN
fuelectenerg-3675	226	28	sensor	sensor	NOUN
fuelectenerg-3675	226	29	.	.	PUNCT
fuelectenerg-3675	227	1	the	the	DET
fuelectenerg-3675	227	2	reason	reason	NOUN
fuelectenerg-3675	227	3	is	be	AUX
fuelectenerg-3675	227	4	a	a	DET
fuelectenerg-3675	227	5	relatively	relatively	ADV
fuelectenerg-3675	227	6	high	high	ADJ
fuelectenerg-3675	227	7	value	value	NOUN
fuelectenerg-3675	227	8	of	of	ADP
fuelectenerg-3675	227	9	the	the	DET
fuelectenerg-3675	227	10	measured	measured	ADJ
fuelectenerg-3675	227	11	voltage	voltage	NOUN
fuelectenerg-3675	227	12	,	,	PUNCT
fuelectenerg-3675	227	13	as	as	ADV
fuelectenerg-3675	227	14	well	well	ADV
fuelectenerg-3675	227	15	as	as	ADP
fuelectenerg-3675	227	16	high	high	ADJ
fuelectenerg-3675	227	17	measuring	measure	VERB
fuelectenerg-3675	227	18	range	range	NOUN
fuelectenerg-3675	227	19	.	.	PUNCT
fuelectenerg-3675	228	1	the	the	DET
fuelectenerg-3675	228	2	absolute	absolute	ADJ
fuelectenerg-3675	228	3	uncertainty	uncertainty	NOUN
fuelectenerg-3675	228	4	ub	ub	ADP
fuelectenerg-3675	228	5	,	,	PUNCT
fuelectenerg-3675	228	6	uhmax	uhmax	PROPN
fuelectenerg-3675	228	7	depends	depend	VERB
fuelectenerg-3675	228	8	on	on	ADP
fuelectenerg-3675	228	9	both	both	DET
fuelectenerg-3675	228	10	values	value	NOUN
fuelectenerg-3675	228	11	.	.	PUNCT
fuelectenerg-3675	229	1	calculated	calculate	VERB
fuelectenerg-3675	229	2	uncertainty	uncertainty	NOUN
fuelectenerg-3675	229	3	refers	refer	VERB
fuelectenerg-3675	229	4	only	only	ADV
fuelectenerg-3675	229	5	to	to	ADP
fuelectenerg-3675	229	6	the	the	DET
fuelectenerg-3675	229	7	measurements	measurement	NOUN
fuelectenerg-3675	229	8	performed	perform	VERB
fuelectenerg-3675	229	9	at	at	ADP
fuelectenerg-3675	229	10	10	10	NUM
fuelectenerg-3675	229	11	mt	mt	PROPN
fuelectenerg-3675	229	12	.	.	PROPN
fuelectenerg-3675	230	1	whole	whole	ADJ
fuelectenerg-3675	230	2	calculation	calculation	NOUN
fuelectenerg-3675	230	3	described	describe	VERB
fuelectenerg-3675	230	4	need	need	VERB
fuelectenerg-3675	230	5	to	to	PART
fuelectenerg-3675	230	6	be	be	AUX
fuelectenerg-3675	230	7	repeated	repeat	VERB
fuelectenerg-3675	230	8	to	to	PART
fuelectenerg-3675	230	9	obtain	obtain	VERB
fuelectenerg-3675	230	10	uncertainty	uncertainty	NOUN
fuelectenerg-3675	230	11	for	for	ADP
fuelectenerg-3675	230	12	other	other	ADJ
fuelectenerg-3675	230	13	values	value	NOUN
fuelectenerg-3675	230	14	of	of	ADP
fuelectenerg-3675	230	15	magnetic	magnetic	ADJ
fuelectenerg-3675	230	16	flux	flux	NOUN
fuelectenerg-3675	230	17	density	density	PROPN
fuelectenerg-3675	230	18	.	.	PUNCT
fuelectenerg-3675	231	1	the	the	DET
fuelectenerg-3675	231	2	results	result	NOUN
fuelectenerg-3675	231	3	of	of	ADP
fuelectenerg-3675	231	4	the	the	DET
fuelectenerg-3675	231	5	calibration	calibration	NOUN
fuelectenerg-3675	231	6	can	can	AUX
fuelectenerg-3675	231	7	be	be	AUX
fuelectenerg-3675	231	8	used	use	VERB
fuelectenerg-3675	231	9	in	in	ADP
fuelectenerg-3675	231	10	further	further	ADJ
fuelectenerg-3675	231	11	measurements	measurement	NOUN
fuelectenerg-3675	231	12	with	with	ADP
fuelectenerg-3675	231	13	a	a	DET
fuelectenerg-3675	231	14	magnetometer	magnetometer	NOUN
fuelectenerg-3675	231	15	to	to	PART
fuelectenerg-3675	231	16	shorten	shorten	VERB
fuelectenerg-3675	231	17	the	the	DET
fuelectenerg-3675	231	18	time	time	NOUN
fuelectenerg-3675	231	19	needed	need	VERB
fuelectenerg-3675	231	20	for	for	ADP
fuelectenerg-3675	231	21	measurement	measurement	NOUN
fuelectenerg-3675	231	22	and	and	CCONJ
fuelectenerg-3675	231	23	calculation	calculation	NOUN
fuelectenerg-3675	231	24	.	.	PUNCT
fuelectenerg-3675	232	1	they	they	PRON
fuelectenerg-3675	232	2	can	can	AUX
fuelectenerg-3675	232	3	be	be	AUX
fuelectenerg-3675	232	4	used	use	VERB
fuelectenerg-3675	232	5	in	in	ADP
fuelectenerg-3675	232	6	different	different	ADJ
fuelectenerg-3675	232	7	624	624	NUM
fuelectenerg-3675	232	8	b.	b.	PROPN
fuelectenerg-3675	232	9	koprivica	koprivica	PROPN
fuelectenerg-3675	232	10	,	,	PUNCT
fuelectenerg-3675	232	11	m.	m.	NOUN
fuelectenerg-3675	232	12	šućurović	šućurović	PROPN
fuelectenerg-3675	232	13	,	,	PUNCT
fuelectenerg-3675	232	14	a.	a.	NOUN
fuelectenerg-3675	232	15	milovanović	milovanović	PROPN
fuelectenerg-3675	232	16	ways	way	NOUN
fuelectenerg-3675	232	17	.	.	PUNCT
fuelectenerg-3675	233	1	at	at	ADP
fuelectenerg-3675	233	2	first	first	ADV
fuelectenerg-3675	233	3	,	,	PUNCT
fuelectenerg-3675	233	4	the	the	DET
fuelectenerg-3675	233	5	calibration	calibration	NOUN
fuelectenerg-3675	233	6	constant	constant	ADJ
fuelectenerg-3675	233	7	of	of	ADP
fuelectenerg-3675	233	8	the	the	DET
fuelectenerg-3675	233	9	large	large	ADJ
fuelectenerg-3675	233	10	solenoid	solenoid	NOUN
fuelectenerg-3675	233	11	can	can	AUX
fuelectenerg-3675	233	12	be	be	AUX
fuelectenerg-3675	233	13	used	use	VERB
fuelectenerg-3675	233	14	for	for	ADP
fuelectenerg-3675	233	15	calculation	calculation	NOUN
fuelectenerg-3675	233	16	of	of	ADP
fuelectenerg-3675	233	17	the	the	DET
fuelectenerg-3675	233	18	time	time	NOUN
fuelectenerg-3675	233	19	waveform	waveform	NOUN
fuelectenerg-3675	233	20	of	of	ADP
fuelectenerg-3675	233	21	the	the	DET
fuelectenerg-3675	233	22	magnetic	magnetic	ADJ
fuelectenerg-3675	233	23	field	field	NOUN
fuelectenerg-3675	233	24	generated	generate	VERB
fuelectenerg-3675	233	25	by	by	ADP
fuelectenerg-3675	233	26	the	the	DET
fuelectenerg-3675	233	27	large	large	ADJ
fuelectenerg-3675	233	28	solenoid	solenoid	NOUN
fuelectenerg-3675	233	29	from	from	ADP
fuelectenerg-3675	233	30	the	the	DET
fuelectenerg-3675	233	31	measured	measure	VERB
fuelectenerg-3675	233	32	electric	electric	ADJ
fuelectenerg-3675	233	33	current	current	ADJ
fuelectenerg-3675	233	34	i(t	i(t	NOUN
fuelectenerg-3675	233	35	)	)	PUNCT
fuelectenerg-3675	233	36	,	,	PUNCT
fuelectenerg-3675	233	37	as	as	ADP
fuelectenerg-3675	233	38	h(t)=19.77i(t)/μ0	h(t)=19.77i(t)/μ0	PROPN
fuelectenerg-3675	233	39	.	.	PUNCT
fuelectenerg-3675	234	1	as	as	ADP
fuelectenerg-3675	234	2	a	a	DET
fuelectenerg-3675	234	3	consequence	consequence	NOUN
fuelectenerg-3675	234	4	,	,	PUNCT
fuelectenerg-3675	234	5	the	the	DET
fuelectenerg-3675	234	6	hall	hall	NOUN
fuelectenerg-3675	234	7	sensor	sensor	NOUN
fuelectenerg-3675	234	8	may	may	AUX
fuelectenerg-3675	234	9	be	be	AUX
fuelectenerg-3675	234	10	excluded	exclude	VERB
fuelectenerg-3675	234	11	from	from	ADP
fuelectenerg-3675	234	12	the	the	DET
fuelectenerg-3675	234	13	measurement	measurement	NOUN
fuelectenerg-3675	234	14	setup	setup	NOUN
fuelectenerg-3675	234	15	.	.	PUNCT
fuelectenerg-3675	235	1	additionally	additionally	ADV
fuelectenerg-3675	235	2	,	,	PUNCT
fuelectenerg-3675	235	3	the	the	DET
fuelectenerg-3675	235	4	magnetic	magnetic	ADJ
fuelectenerg-3675	235	5	field	field	NOUN
fuelectenerg-3675	235	6	can	can	AUX
fuelectenerg-3675	235	7	be	be	AUX
fuelectenerg-3675	235	8	also	also	ADV
fuelectenerg-3675	235	9	calculated	calculate	VERB
fuelectenerg-3675	235	10	from	from	ADP
fuelectenerg-3675	235	11	the	the	DET
fuelectenerg-3675	235	12	integral	integral	ADJ
fuelectenerg-3675	235	13	of	of	ADP
fuelectenerg-3675	235	14	measured	measure	VERB
fuelectenerg-3675	235	15	voltage	voltage	NOUN
fuelectenerg-3675	235	16	ul1(t	ul1(t	NOUN
fuelectenerg-3675	235	17	)	)	PUNCT
fuelectenerg-3675	235	18	of	of	ADP
fuelectenerg-3675	235	19	the	the	DET
fuelectenerg-3675	235	20	pickup	pickup	NOUN
fuelectenerg-3675	235	21	coil	coil	NOUN
fuelectenerg-3675	235	22	l1	l1	PROPN
fuelectenerg-3675	235	23	as	as	ADP
fuelectenerg-3675	235	24	h(t)=−ul1(t−t/4)/(μ0ωkl1	h(t)=−ul1(t−t/4)/(μ0ωkl1	NOUN
fuelectenerg-3675	235	25	)	)	PUNCT
fuelectenerg-3675	235	26	,	,	PUNCT
fuelectenerg-3675	235	27	ω=2π	ω=2π	NOUN
fuelectenerg-3675	235	28	/	/	SYM
fuelectenerg-3675	235	29	t	t	NOUN
fuelectenerg-3675	235	30	(	(	PUNCT
fuelectenerg-3675	235	31	in	in	ADP
fuelectenerg-3675	235	32	the	the	DET
fuelectenerg-3675	235	33	case	case	NOUN
fuelectenerg-3675	235	34	of	of	ADP
fuelectenerg-3675	235	35	sinusoidal	sinusoidal	ADJ
fuelectenerg-3675	235	36	excitation	excitation	NOUN
fuelectenerg-3675	235	37	current	current	ADJ
fuelectenerg-3675	235	38	)	)	PUNCT
fuelectenerg-3675	235	39	.	.	PUNCT
fuelectenerg-3675	236	1	thus	thus	ADV
fuelectenerg-3675	236	2	,	,	PUNCT
fuelectenerg-3675	236	3	the	the	DET
fuelectenerg-3675	236	4	shunt	shunt	NOUN
fuelectenerg-3675	236	5	resistor	resistor	NOUN
fuelectenerg-3675	236	6	for	for	ADP
fuelectenerg-3675	236	7	current	current	ADJ
fuelectenerg-3675	236	8	measurement	measurement	NOUN
fuelectenerg-3675	236	9	can	can	AUX
fuelectenerg-3675	236	10	be	be	AUX
fuelectenerg-3675	236	11	also	also	ADV
fuelectenerg-3675	236	12	excluded	exclude	VERB
fuelectenerg-3675	236	13	from	from	ADP
fuelectenerg-3675	236	14	the	the	DET
fuelectenerg-3675	236	15	measurement	measurement	NOUN
fuelectenerg-3675	236	16	setup	setup	NOUN
fuelectenerg-3675	236	17	.	.	PUNCT
fuelectenerg-3675	237	1	calibration	calibration	NOUN
fuelectenerg-3675	237	2	constants	constant	NOUN
fuelectenerg-3675	237	3	of	of	ADP
fuelectenerg-3675	237	4	other	other	ADJ
fuelectenerg-3675	237	5	four	four	NUM
fuelectenerg-3675	237	6	pickup	pickup	NOUN
fuelectenerg-3675	237	7	coils	coil	NOUN
fuelectenerg-3675	237	8	can	can	AUX
fuelectenerg-3675	237	9	be	be	AUX
fuelectenerg-3675	237	10	used	use	VERB
fuelectenerg-3675	237	11	in	in	ADP
fuelectenerg-3675	237	12	calculations	calculation	NOUN
fuelectenerg-3675	237	13	of	of	ADP
fuelectenerg-3675	237	14	time	time	NOUN
fuelectenerg-3675	237	15	waveforms	waveform	NOUN
fuelectenerg-3675	237	16	of	of	ADP
fuelectenerg-3675	237	17	the	the	DET
fuelectenerg-3675	237	18	magnetic	magnetic	ADJ
fuelectenerg-3675	237	19	flux	flux	PROPN
fuelectenerg-3675	237	20	density	density	PROPN
fuelectenerg-3675	237	21	b	b	PROPN
fuelectenerg-3675	237	22	and	and	CCONJ
fuelectenerg-3675	237	23	the	the	DET
fuelectenerg-3675	237	24	magnetisation	magnetisation	NOUN
fuelectenerg-3675	237	25	m	m	X
fuelectenerg-3675	237	26	of	of	ADP
fuelectenerg-3675	237	27	the	the	DET
fuelectenerg-3675	237	28	ferromagnetic	ferromagnetic	ADJ
fuelectenerg-3675	237	29	sample	sample	NOUN
fuelectenerg-3675	237	30	.	.	PUNCT
fuelectenerg-3675	238	1	similar	similar	ADJ
fuelectenerg-3675	238	2	to	to	ADP
fuelectenerg-3675	238	3	expression	expression	NOUN
fuelectenerg-3675	238	4	(	(	PUNCT
fuelectenerg-3675	238	5	2	2	NUM
fuelectenerg-3675	238	6	)	)	PUNCT
fuelectenerg-3675	238	7	,	,	PUNCT
fuelectenerg-3675	238	8	in	in	ADP
fuelectenerg-3675	238	9	the	the	DET
fuelectenerg-3675	238	10	case	case	NOUN
fuelectenerg-3675	238	11	when	when	SCONJ
fuelectenerg-3675	238	12	ferromagnetic	ferromagnetic	ADJ
fuelectenerg-3675	238	13	sample	sample	NOUN
fuelectenerg-3675	238	14	is	be	AUX
fuelectenerg-3675	238	15	placed	place	VERB
fuelectenerg-3675	238	16	inside	inside	ADP
fuelectenerg-3675	238	17	the	the	DET
fuelectenerg-3675	238	18	pickup	pickup	NOUN
fuelectenerg-3675	238	19	coil	coil	NOUN
fuelectenerg-3675	238	20	l2	l2	NOUN
fuelectenerg-3675	238	21	,	,	PUNCT
fuelectenerg-3675	238	22	the	the	DET
fuelectenerg-3675	238	23	following	follow	VERB
fuelectenerg-3675	238	24	expression	expression	NOUN
fuelectenerg-3675	238	25	can	can	AUX
fuelectenerg-3675	238	26	be	be	AUX
fuelectenerg-3675	238	27	used	use	VERB
fuelectenerg-3675	238	28	:	:	PUNCT
fuelectenerg-3675	238	29	2	2	NUM
fuelectenerg-3675	238	30	2	2	NUM
fuelectenerg-3675	238	31	2	2	NUM
fuelectenerg-3675	238	32	0	0	NUM
fuelectenerg-3675	239	1	d	d	NOUN
fuelectenerg-3675	239	2	d	d	PROPN
fuelectenerg-3675	239	3	d	d	X
fuelectenerg-3675	239	4	d	d	X
fuelectenerg-3675	239	5	s	s	PROPN
fuelectenerg-3675	239	6	l	l	NOUN
fuelectenerg-3675	239	7	l	l	NOUN
fuelectenerg-3675	239	8	l	l	NOUN
fuelectenerg-3675	239	9	s	s	NOUN
fuelectenerg-3675	239	10	m	m	VERB
fuelectenerg-3675	239	11	h	h	NOUN
fuelectenerg-3675	239	12	u	u	X
fuelectenerg-3675	239	13	k	k	PROPN
fuelectenerg-3675	239	14	s	s	PROPN
fuelectenerg-3675	239	15	t	t	PROPN
fuelectenerg-3675	239	16	t	t	PROPN
fuelectenerg-3675	239	17			NOUN
fuelectenerg-3675	240	1			PROPN
fuelectenerg-3675	240	2			PROPN
fuelectenerg-3675	240	3			PROPN
fuelectenerg-3675	240	4			PROPN
fuelectenerg-3675	240	5			PUNCT
fuelectenerg-3675	240	6			PROPN
fuelectenerg-3675	240	7			PROPN
fuelectenerg-3675	240	8			PROPN
fuelectenerg-3675	240	9			NOUN
fuelectenerg-3675	240	10	,	,	PUNCT
fuelectenerg-3675	240	11	(	(	PUNCT
fuelectenerg-3675	240	12	10	10	NUM
fuelectenerg-3675	240	13	)	)	PUNCT
fuelectenerg-3675	240	14	where	where	SCONJ
fuelectenerg-3675	240	15	ul2	ul2	SCONJ
fuelectenerg-3675	240	16	is	be	AUX
fuelectenerg-3675	240	17	the	the	DET
fuelectenerg-3675	240	18	measured	measure	VERB
fuelectenerg-3675	240	19	voltage	voltage	NOUN
fuelectenerg-3675	240	20	of	of	ADP
fuelectenerg-3675	240	21	the	the	DET
fuelectenerg-3675	240	22	pickup	pickup	ADJ
fuelectenerg-3675	240	23	coil	coil	NOUN
fuelectenerg-3675	240	24	l2	l2	NOUN
fuelectenerg-3675	240	25	,	,	PUNCT
fuelectenerg-3675	240	26	sl2	sl2	PROPN
fuelectenerg-3675	240	27	=	=	PRON
fuelectenerg-3675	240	28	πrp	πrp	ADJ
fuelectenerg-3675	240	29	2	2	NUM
fuelectenerg-3675	240	30	is	be	AUX
fuelectenerg-3675	240	31	the	the	DET
fuelectenerg-3675	240	32	cross	cross	ADJ
fuelectenerg-3675	240	33	-	-	ADJ
fuelectenerg-3675	240	34	section	section	ADJ
fuelectenerg-3675	240	35	area	area	NOUN
fuelectenerg-3675	240	36	and	and	CCONJ
fuelectenerg-3675	240	37	rp=7.5	rp=7.5	PROPN
fuelectenerg-3675	240	38	mm	mm	PROPN
fuelectenerg-3675	240	39	is	be	AUX
fuelectenerg-3675	240	40	the	the	DET
fuelectenerg-3675	240	41	inner	inner	ADJ
fuelectenerg-3675	240	42	radius	radius	NOUN
fuelectenerg-3675	240	43	of	of	ADP
fuelectenerg-3675	240	44	the	the	DET
fuelectenerg-3675	240	45	pickup	pickup	ADJ
fuelectenerg-3675	240	46	coil	coil	NOUN
fuelectenerg-3675	240	47	.	.	PUNCT
fuelectenerg-3675	241	1	the	the	DET
fuelectenerg-3675	241	2	magnetisation	magnetisation	NOUN
fuelectenerg-3675	241	3	of	of	ADP
fuelectenerg-3675	241	4	the	the	DET
fuelectenerg-3675	241	5	sample	sample	NOUN
fuelectenerg-3675	241	6	can	can	AUX
fuelectenerg-3675	241	7	be	be	AUX
fuelectenerg-3675	241	8	obtained	obtain	VERB
fuelectenerg-3675	241	9	by	by	ADP
fuelectenerg-3675	241	10	integration	integration	NOUN
fuelectenerg-3675	241	11	of	of	ADP
fuelectenerg-3675	241	12	this	this	DET
fuelectenerg-3675	241	13	voltage	voltage	NOUN
fuelectenerg-3675	241	14	and	and	CCONJ
fuelectenerg-3675	241	15	by	by	ADP
fuelectenerg-3675	241	16	substituting	substitute	VERB
fuelectenerg-3675	241	17	the	the	DET
fuelectenerg-3675	241	18	magnetic	magnetic	ADJ
fuelectenerg-3675	241	19	field	field	NOUN
fuelectenerg-3675	241	20	expressed	express	VERB
fuelectenerg-3675	241	21	over	over	ADP
fuelectenerg-3675	241	22	the	the	DET
fuelectenerg-3675	241	23	voltage	voltage	NOUN
fuelectenerg-3675	241	24	ul1	ul1	PROPN
fuelectenerg-3675	241	25	as	as	ADP
fuelectenerg-3675	241	26	:	:	PUNCT
fuelectenerg-3675	241	27	2	2	NUM
fuelectenerg-3675	241	28	2	2	NUM
fuelectenerg-3675	241	29	20	20	NUM
fuelectenerg-3675	241	30	0	0	NUM
fuelectenerg-3675	241	31	1	1	NUM
fuelectenerg-3675	241	32	d	d	NOUN
fuelectenerg-3675	241	33	t	t	NOUN
fuelectenerg-3675	241	34	l	l	NOUN
fuelectenerg-3675	241	35	l	l	NOUN
fuelectenerg-3675	241	36	s	s	PART
fuelectenerg-3675	241	37	l	l	NOUN
fuelectenerg-3675	241	38	s	s	PART
fuelectenerg-3675	241	39	m	m	VERB
fuelectenerg-3675	241	40	u	u	NOUN
fuelectenerg-3675	241	41	t	t	NOUN
fuelectenerg-3675	241	42	h	h	NOUN
fuelectenerg-3675	241	43	s	s	PART
fuelectenerg-3675	242	1	k	k	PROPN
fuelectenerg-3675	242	2			NOUN
fuelectenerg-3675	242	3			PROPN
fuelectenerg-3675	242	4			PROPN
fuelectenerg-3675	242	5			VERB
fuelectenerg-3675	242	6			PROPN
fuelectenerg-3675	242	7			PROPN
fuelectenerg-3675	242	8			PROPN
fuelectenerg-3675	242	9			PROPN
fuelectenerg-3675	242	10			PROPN
fuelectenerg-3675	242	11			NOUN
fuelectenerg-3675	242	12			PUNCT
fuelectenerg-3675	242	13	.	.	PUNCT
fuelectenerg-3675	243	1	(	(	PUNCT
fuelectenerg-3675	243	2	11	11	NUM
fuelectenerg-3675	243	3	)	)	PUNCT
fuelectenerg-3675	243	4	on	on	ADP
fuelectenerg-3675	243	5	the	the	DET
fuelectenerg-3675	243	6	other	other	ADJ
fuelectenerg-3675	243	7	hand	hand	NOUN
fuelectenerg-3675	243	8	,	,	PUNCT
fuelectenerg-3675	243	9	the	the	DET
fuelectenerg-3675	243	10	voltage	voltage	NOUN
fuelectenerg-3675	243	11	u2	u2	NOUN
fuelectenerg-3675	243	12	between	between	ADP
fuelectenerg-3675	243	13	points	point	NOUN
fuelectenerg-3675	243	14	2	2	NUM
fuelectenerg-3675	243	15	and	and	CCONJ
fuelectenerg-3675	243	16	4	4	NUM
fuelectenerg-3675	243	17	(	(	PUNCT
fuelectenerg-3675	243	18	fig	fig	NOUN
fuelectenerg-3675	243	19	.	.	PUNCT
fuelectenerg-3675	243	20	2b	2b	NOUN
fuelectenerg-3675	243	21	)	)	PUNCT
fuelectenerg-3675	243	22	can	can	AUX
fuelectenerg-3675	243	23	be	be	AUX
fuelectenerg-3675	243	24	obtained	obtain	VERB
fuelectenerg-3675	243	25	using	use	VERB
fuelectenerg-3675	243	26	only	only	ADV
fuelectenerg-3675	243	27	the	the	DET
fuelectenerg-3675	243	28	magnetisation	magnetisation	NOUN
fuelectenerg-3675	243	29	:	:	PUNCT
fuelectenerg-3675	243	30	2	2	NUM
fuelectenerg-3675	243	31	2	2	NUM
fuelectenerg-3675	243	32	2	2	NUM
fuelectenerg-3675	243	33	0	0	NUM
fuelectenerg-3675	243	34	d	d	NOUN
fuelectenerg-3675	243	35	d	d	PROPN
fuelectenerg-3675	243	36	s	s	PROPN
fuelectenerg-3675	243	37	l	l	NOUN
fuelectenerg-3675	243	38	l	l	NOUN
fuelectenerg-3675	243	39	s	s	NOUN
fuelectenerg-3675	243	40	m	m	VERB
fuelectenerg-3675	243	41	u	u	ADJ
fuelectenerg-3675	243	42	k	k	PROPN
fuelectenerg-3675	243	43	s	s	PROPN
fuelectenerg-3675	243	44	t	t	PROPN
fuelectenerg-3675	243	45			PROPN
fuelectenerg-3675	243	46			PROPN
fuelectenerg-3675	243	47	.	.	PUNCT
fuelectenerg-3675	244	1	(	(	PUNCT
fuelectenerg-3675	244	2	12	12	NUM
fuelectenerg-3675	244	3	)	)	PUNCT
fuelectenerg-3675	244	4	the	the	DET
fuelectenerg-3675	244	5	magnetisation	magnetisation	NOUN
fuelectenerg-3675	244	6	of	of	ADP
fuelectenerg-3675	244	7	the	the	DET
fuelectenerg-3675	244	8	sample	sample	NOUN
fuelectenerg-3675	244	9	is	be	AUX
fuelectenerg-3675	244	10	obtained	obtain	VERB
fuelectenerg-3675	244	11	by	by	ADP
fuelectenerg-3675	244	12	the	the	DET
fuelectenerg-3675	244	13	integration	integration	NOUN
fuelectenerg-3675	244	14	of	of	ADP
fuelectenerg-3675	244	15	(	(	PUNCT
fuelectenerg-3675	244	16	12	12	NUM
fuelectenerg-3675	244	17	)	)	PUNCT
fuelectenerg-3675	244	18	,	,	PUNCT
fuelectenerg-3675	244	19	as	as	SCONJ
fuelectenerg-3675	244	20	:	:	SYM
fuelectenerg-3675	244	21	2	2	NUM
fuelectenerg-3675	244	22	2	2	NUM
fuelectenerg-3675	244	23	2	2	NUM
fuelectenerg-3675	244	24	0	0	NUM
fuelectenerg-3675	244	25	0	0	NUM
fuelectenerg-3675	244	26	1	1	NUM
fuelectenerg-3675	244	27	d	d	NOUN
fuelectenerg-3675	244	28	t	t	NOUN
fuelectenerg-3675	244	29	l	l	NOUN
fuelectenerg-3675	244	30	l	l	NOUN
fuelectenerg-3675	244	31	s	s	X
fuelectenerg-3675	244	32	s	s	NOUN
fuelectenerg-3675	244	33	m	m	VERB
fuelectenerg-3675	244	34	u	u	NOUN
fuelectenerg-3675	245	1	t	t	NOUN
fuelectenerg-3675	245	2	k	k	PROPN
fuelectenerg-3675	245	3	s	s	PROPN
fuelectenerg-3675	245	4			PROPN
fuelectenerg-3675	245	5			NOUN
fuelectenerg-3675	245	6			NOUN
fuelectenerg-3675	245	7			PUNCT
fuelectenerg-3675	245	8	.	.	PUNCT
fuelectenerg-3675	246	1	(	(	PUNCT
fuelectenerg-3675	246	2	13	13	NUM
fuelectenerg-3675	246	3	)	)	PUNCT
fuelectenerg-3675	246	4	the	the	DET
fuelectenerg-3675	246	5	magnetic	magnetic	PROPN
fuelectenerg-3675	246	6	flux	flux	NOUN
fuelectenerg-3675	246	7	density	density	NOUN
fuelectenerg-3675	246	8	of	of	ADP
fuelectenerg-3675	246	9	the	the	DET
fuelectenerg-3675	246	10	sample	sample	NOUN
fuelectenerg-3675	246	11	can	can	AUX
fuelectenerg-3675	246	12	be	be	AUX
fuelectenerg-3675	246	13	calculated	calculate	VERB
fuelectenerg-3675	246	14	using	use	VERB
fuelectenerg-3675	246	15	(	(	PUNCT
fuelectenerg-3675	246	16	11	11	NUM
fuelectenerg-3675	246	17	)	)	PUNCT
fuelectenerg-3675	246	18	or	or	CCONJ
fuelectenerg-3675	246	19	(	(	PUNCT
fuelectenerg-3675	246	20	13	13	NUM
fuelectenerg-3675	246	21	)	)	PUNCT
fuelectenerg-3675	246	22	and	and	CCONJ
fuelectenerg-3675	246	23	previously	previously	ADV
fuelectenerg-3675	246	24	calculated	calculate	VERB
fuelectenerg-3675	246	25	h(t	h(t	PROPN
fuelectenerg-3675	246	26	)	)	PUNCT
fuelectenerg-3675	246	27	,	,	PUNCT
fuelectenerg-3675	246	28	according	accord	VERB
fuelectenerg-3675	246	29	to	to	ADP
fuelectenerg-3675	246	30	well	well	ADV
fuelectenerg-3675	246	31	-	-	PUNCT
fuelectenerg-3675	246	32	known	know	VERB
fuelectenerg-3675	246	33	relation	relation	NOUN
fuelectenerg-3675	246	34	:	:	PUNCT
fuelectenerg-3675	246	35	0	0	NUM
fuelectenerg-3675	246	36	(	(	PUNCT
fuelectenerg-3675	246	37	)	)	PUNCT
fuelectenerg-3675	246	38	b	b	X
fuelectenerg-3675	246	39	m	m	VERB
fuelectenerg-3675	246	40	h	h	ADJ
fuelectenerg-3675	246	41			NOUN
fuelectenerg-3675	246	42			PUNCT
fuelectenerg-3675	246	43	.	.	PUNCT
fuelectenerg-3675	247	1	(	(	PUNCT
fuelectenerg-3675	247	2	14	14	NUM
fuelectenerg-3675	247	3	)	)	PUNCT
fuelectenerg-3675	247	4	similar	similar	ADJ
fuelectenerg-3675	247	5	expressions	expression	NOUN
fuelectenerg-3675	247	6	can	can	AUX
fuelectenerg-3675	247	7	be	be	AUX
fuelectenerg-3675	247	8	used	use	VERB
fuelectenerg-3675	247	9	for	for	ADP
fuelectenerg-3675	247	10	other	other	ADJ
fuelectenerg-3675	247	11	pickup	pickup	NOUN
fuelectenerg-3675	247	12	coils	coil	NOUN
fuelectenerg-3675	247	13	in	in	ADP
fuelectenerg-3675	247	14	the	the	DET
fuelectenerg-3675	247	15	case	case	NOUN
fuelectenerg-3675	247	16	when	when	SCONJ
fuelectenerg-3675	247	17	the	the	DET
fuelectenerg-3675	247	18	ferromagnetic	ferromagnetic	ADJ
fuelectenerg-3675	247	19	sample	sample	NOUN
fuelectenerg-3675	247	20	is	be	AUX
fuelectenerg-3675	247	21	placed	place	VERB
fuelectenerg-3675	247	22	inside	inside	ADP
fuelectenerg-3675	247	23	these	these	DET
fuelectenerg-3675	247	24	coils	coil	NOUN
fuelectenerg-3675	247	25	.	.	PUNCT
fuelectenerg-3675	248	1	however	however	ADV
fuelectenerg-3675	248	2	,	,	PUNCT
fuelectenerg-3675	248	3	the	the	DET
fuelectenerg-3675	248	4	above	above	ADJ
fuelectenerg-3675	248	5	analysis	analysis	NOUN
fuelectenerg-3675	248	6	may	may	AUX
fuelectenerg-3675	248	7	lead	lead	VERB
fuelectenerg-3675	248	8	to	to	ADP
fuelectenerg-3675	248	9	measurement	measurement	NOUN
fuelectenerg-3675	248	10	errors	error	NOUN
fuelectenerg-3675	248	11	caused	cause	VERB
fuelectenerg-3675	248	12	by	by	ADP
fuelectenerg-3675	248	13	two	two	NUM
fuelectenerg-3675	248	14	effects	effect	NOUN
fuelectenerg-3675	248	15	.	.	PUNCT
fuelectenerg-3675	249	1	the	the	DET
fuelectenerg-3675	249	2	first	first	ADJ
fuelectenerg-3675	249	3	one	one	NOUN
fuelectenerg-3675	249	4	is	be	AUX
fuelectenerg-3675	249	5	related	relate	VERB
fuelectenerg-3675	249	6	to	to	ADP
fuelectenerg-3675	249	7	the	the	DET
fuelectenerg-3675	249	8	shape	shape	NOUN
fuelectenerg-3675	249	9	of	of	ADP
fuelectenerg-3675	249	10	the	the	DET
fuelectenerg-3675	249	11	excitation	excitation	NOUN
fuelectenerg-3675	249	12	current	current	ADJ
fuelectenerg-3675	249	13	.	.	PUNCT
fuelectenerg-3675	250	1	as	as	ADV
fuelectenerg-3675	250	2	soon	soon	ADV
fuelectenerg-3675	250	3	as	as	SCONJ
fuelectenerg-3675	250	4	the	the	DET
fuelectenerg-3675	250	5	ferromagnetic	ferromagnetic	ADJ
fuelectenerg-3675	250	6	sample	sample	NOUN
fuelectenerg-3675	250	7	is	be	AUX
fuelectenerg-3675	250	8	placed	place	VERB
fuelectenerg-3675	250	9	inside	inside	ADP
fuelectenerg-3675	250	10	a	a	DET
fuelectenerg-3675	250	11	pickup	pickup	NOUN
fuelectenerg-3675	250	12	coil	coil	NOUN
fuelectenerg-3675	250	13	,	,	PUNCT
fuelectenerg-3675	250	14	for	for	ADP
fuelectenerg-3675	250	15	the	the	DET
fuelectenerg-3675	250	16	same	same	ADJ
fuelectenerg-3675	250	17	excitation	excitation	NOUN
fuelectenerg-3675	250	18	voltage	voltage	NOUN
fuelectenerg-3675	250	19	,	,	PUNCT
fuelectenerg-3675	250	20	the	the	DET
fuelectenerg-3675	250	21	magnetising	magnetise	VERB
fuelectenerg-3675	250	22	current	current	NOUN
fuelectenerg-3675	250	23	will	will	AUX
fuelectenerg-3675	250	24	change	change	VERB
fuelectenerg-3675	250	25	by	by	ADP
fuelectenerg-3675	250	26	some	some	DET
fuelectenerg-3675	250	27	amount	amount	NOUN
fuelectenerg-3675	250	28	.	.	PUNCT
fuelectenerg-3675	251	1	this	this	DET
fuelectenerg-3675	251	2	change	change	NOUN
fuelectenerg-3675	251	3	may	may	AUX
fuelectenerg-3675	251	4	be	be	AUX
fuelectenerg-3675	251	5	large	large	ADJ
fuelectenerg-3675	251	6	and	and	CCONJ
fuelectenerg-3675	251	7	the	the	DET
fuelectenerg-3675	251	8	shape	shape	NOUN
fuelectenerg-3675	251	9	of	of	ADP
fuelectenerg-3675	251	10	the	the	DET
fuelectenerg-3675	251	11	current	current	NOUN
fuelectenerg-3675	251	12	may	may	AUX
fuelectenerg-3675	251	13	be	be	AUX
fuelectenerg-3675	251	14	significantly	significantly	ADV
fuelectenerg-3675	251	15	distorted	distort	VERB
fuelectenerg-3675	251	16	from	from	ADP
fuelectenerg-3675	251	17	sinusoidal	sinusoidal	NOUN
fuelectenerg-3675	251	18	.	.	PUNCT
fuelectenerg-3675	252	1	the	the	DET
fuelectenerg-3675	252	2	level	level	NOUN
fuelectenerg-3675	252	3	of	of	ADP
fuelectenerg-3675	252	4	influence	influence	NOUN
fuelectenerg-3675	252	5	depends	depend	VERB
fuelectenerg-3675	252	6	on	on	ADP
fuelectenerg-3675	252	7	material	material	ADJ
fuelectenerg-3675	252	8	calibration	calibration	NOUN
fuelectenerg-3675	252	9	of	of	ADP
fuelectenerg-3675	252	10	ac	ac	PROPN
fuelectenerg-3675	252	11	induction	induction	NOUN
fuelectenerg-3675	252	12	magnetometer	magnetometer	NOUN
fuelectenerg-3675	252	13	625	625	NUM
fuelectenerg-3675	252	14	characteristics	characteristic	NOUN
fuelectenerg-3675	252	15	.	.	PUNCT
fuelectenerg-3675	253	1	this	this	DET
fuelectenerg-3675	253	2	effect	effect	NOUN
fuelectenerg-3675	253	3	can	can	AUX
fuelectenerg-3675	253	4	be	be	AUX
fuelectenerg-3675	253	5	overcome	overcome	VERB
fuelectenerg-3675	253	6	by	by	ADP
fuelectenerg-3675	253	7	digital	digital	ADJ
fuelectenerg-3675	253	8	feedback	feedback	NOUN
fuelectenerg-3675	253	9	based	base	VERB
fuelectenerg-3675	253	10	on	on	ADP
fuelectenerg-3675	253	11	computer	computer	NOUN
fuelectenerg-3675	253	12	,	,	PUNCT
fuelectenerg-3675	253	13	as	as	SCONJ
fuelectenerg-3675	253	14	it	it	PRON
fuelectenerg-3675	253	15	has	have	AUX
fuelectenerg-3675	253	16	been	be	AUX
fuelectenerg-3675	253	17	discussed	discuss	VERB
fuelectenerg-3675	253	18	thoroughly	thoroughly	ADV
fuelectenerg-3675	253	19	in	in	ADP
fuelectenerg-3675	253	20	the	the	DET
fuelectenerg-3675	253	21	literature	literature	NOUN
fuelectenerg-3675	254	1	[	[	X
fuelectenerg-3675	254	2	11	11	NUM
fuelectenerg-3675	254	3	]	]	PUNCT
fuelectenerg-3675	254	4	.	.	PUNCT
fuelectenerg-3675	255	1	the	the	DET
fuelectenerg-3675	255	2	second	second	ADJ
fuelectenerg-3675	255	3	effect	effect	NOUN
fuelectenerg-3675	255	4	also	also	ADV
fuelectenerg-3675	255	5	may	may	AUX
fuelectenerg-3675	255	6	appear	appear	VERB
fuelectenerg-3675	255	7	after	after	ADP
fuelectenerg-3675	255	8	insertion	insertion	NOUN
fuelectenerg-3675	255	9	of	of	ADP
fuelectenerg-3675	255	10	the	the	DET
fuelectenerg-3675	255	11	ferromagnetic	ferromagnetic	ADJ
fuelectenerg-3675	255	12	sample	sample	NOUN
fuelectenerg-3675	255	13	inside	inside	ADP
fuelectenerg-3675	255	14	pickup	pickup	PROPN
fuelectenerg-3675	255	15	coil	coil	NOUN
fuelectenerg-3675	255	16	.	.	PUNCT
fuelectenerg-3675	256	1	the	the	DET
fuelectenerg-3675	256	2	magnetic	magnetic	ADJ
fuelectenerg-3675	256	3	field	field	NOUN
fuelectenerg-3675	256	4	inside	inside	ADP
fuelectenerg-3675	256	5	the	the	DET
fuelectenerg-3675	256	6	pickup	pickup	NOUN
fuelectenerg-3675	256	7	coil	coil	NOUN
fuelectenerg-3675	256	8	with	with	ADP
fuelectenerg-3675	256	9	ferromagnetic	ferromagnetic	ADJ
fuelectenerg-3675	256	10	sample	sample	NOUN
fuelectenerg-3675	256	11	will	will	AUX
fuelectenerg-3675	256	12	be	be	AUX
fuelectenerg-3675	256	13	distorted	distort	VERB
fuelectenerg-3675	256	14	,	,	PUNCT
fuelectenerg-3675	256	15	as	as	ADV
fuelectenerg-3675	256	16	well	well	ADV
fuelectenerg-3675	256	17	as	as	ADP
fuelectenerg-3675	256	18	surrounding	surround	VERB
fuelectenerg-3675	256	19	magnetic	magnetic	ADJ
fuelectenerg-3675	256	20	field	field	NOUN
fuelectenerg-3675	256	21	.	.	PUNCT
fuelectenerg-3675	257	1	this	this	DET
fuelectenerg-3675	257	2	distortion	distortion	NOUN
fuelectenerg-3675	257	3	might	might	AUX
fuelectenerg-3675	257	4	reach	reach	VERB
fuelectenerg-3675	257	5	other	other	ADJ
fuelectenerg-3675	257	6	pickup	pickup	NOUN
fuelectenerg-3675	257	7	coils	coil	NOUN
fuelectenerg-3675	257	8	and	and	CCONJ
fuelectenerg-3675	257	9	disrupt	disrupt	VERB
fuelectenerg-3675	257	10	the	the	DET
fuelectenerg-3675	257	11	air	air	NOUN
fuelectenerg-3675	257	12	flux	flux	PROPN
fuelectenerg-3675	257	13	compensation	compensation	PROPN
fuelectenerg-3675	257	14	,	,	PUNCT
fuelectenerg-3675	257	15	which	which	PRON
fuelectenerg-3675	257	16	would	would	AUX
fuelectenerg-3675	257	17	be	be	AUX
fuelectenerg-3675	257	18	no	no	ADV
fuelectenerg-3675	257	19	longer	long	ADV
fuelectenerg-3675	257	20	effective	effective	ADJ
fuelectenerg-3675	257	21	as	as	SCONJ
fuelectenerg-3675	257	22	it	it	PRON
fuelectenerg-3675	257	23	was	be	AUX
fuelectenerg-3675	257	24	for	for	ADP
fuelectenerg-3675	257	25	the	the	DET
fuelectenerg-3675	257	26	empty	empty	ADJ
fuelectenerg-3675	257	27	coils	coil	NOUN
fuelectenerg-3675	257	28	.	.	PUNCT
fuelectenerg-3675	258	1	this	this	DET
fuelectenerg-3675	258	2	problem	problem	NOUN
fuelectenerg-3675	258	3	can	can	AUX
fuelectenerg-3675	258	4	be	be	AUX
fuelectenerg-3675	258	5	solved	solve	VERB
fuelectenerg-3675	258	6	numerically	numerically	ADV
fuelectenerg-3675	258	7	in	in	ADP
fuelectenerg-3675	258	8	such	such	DET
fuelectenerg-3675	258	9	a	a	DET
fuelectenerg-3675	258	10	way	way	NOUN
fuelectenerg-3675	258	11	that	that	PRON
fuelectenerg-3675	258	12	the	the	DET
fuelectenerg-3675	258	13	compensating	compensating	NOUN
fuelectenerg-3675	258	14	voltage	voltage	NOUN
fuelectenerg-3675	258	15	is	be	AUX
fuelectenerg-3675	258	16	calculated	calculate	VERB
fuelectenerg-3675	258	17	using	use	VERB
fuelectenerg-3675	258	18	measured	measure	VERB
fuelectenerg-3675	258	19	magnetic	magnetic	ADJ
fuelectenerg-3675	258	20	field	field	NOUN
fuelectenerg-3675	258	21	[	[	X
fuelectenerg-3675	258	22	11	11	NUM
fuelectenerg-3675	258	23	]	]	PUNCT
fuelectenerg-3675	258	24	.	.	PUNCT
fuelectenerg-3675	259	1	this	this	DET
fuelectenerg-3675	259	2	voltage	voltage	NOUN
fuelectenerg-3675	259	3	needs	need	VERB
fuelectenerg-3675	259	4	to	to	PART
fuelectenerg-3675	259	5	be	be	AUX
fuelectenerg-3675	259	6	subtracted	subtract	VERB
fuelectenerg-3675	259	7	from	from	ADP
fuelectenerg-3675	259	8	the	the	DET
fuelectenerg-3675	259	9	measured	measure	VERB
fuelectenerg-3675	259	10	voltage	voltage	NOUN
fuelectenerg-3675	259	11	induced	induce	VERB
fuelectenerg-3675	259	12	in	in	ADP
fuelectenerg-3675	259	13	the	the	DET
fuelectenerg-3675	259	14	pickup	pickup	NOUN
fuelectenerg-3675	259	15	coil	coil	NOUN
fuelectenerg-3675	259	16	,	,	PUNCT
fuelectenerg-3675	259	17	for	for	ADP
fuelectenerg-3675	259	18	example	example	NOUN
fuelectenerg-3675	259	19	ul2	ul2	VERB
fuelectenerg-3675	259	20	in	in	ADP
fuelectenerg-3675	259	21	(	(	PUNCT
fuelectenerg-3675	259	22	10	10	NUM
fuelectenerg-3675	259	23	)	)	PUNCT
fuelectenerg-3675	259	24	.	.	PUNCT
fuelectenerg-3675	260	1	consequently	consequently	ADV
fuelectenerg-3675	260	2	,	,	PUNCT
fuelectenerg-3675	260	3	the	the	DET
fuelectenerg-3675	260	4	magnetic	magnetic	ADJ
fuelectenerg-3675	260	5	field	field	NOUN
fuelectenerg-3675	260	6	needs	need	VERB
fuelectenerg-3675	260	7	to	to	PART
fuelectenerg-3675	260	8	be	be	AUX
fuelectenerg-3675	260	9	measured	measure	VERB
fuelectenerg-3675	260	10	accurately	accurately	ADV
fuelectenerg-3675	260	11	to	to	PART
fuelectenerg-3675	260	12	obtain	obtain	VERB
fuelectenerg-3675	260	13	effective	effective	ADJ
fuelectenerg-3675	260	14	air	air	NOUN
fuelectenerg-3675	260	15	flux	flux	PROPN
fuelectenerg-3675	260	16	compensation	compensation	PROPN
fuelectenerg-3675	260	17	.	.	PUNCT
fuelectenerg-3675	261	1	for	for	ADP
fuelectenerg-3675	261	2	these	these	DET
fuelectenerg-3675	261	3	reasons	reason	NOUN
fuelectenerg-3675	261	4	,	,	PUNCT
fuelectenerg-3675	261	5	the	the	DET
fuelectenerg-3675	261	6	analysis	analysis	NOUN
fuelectenerg-3675	261	7	given	give	VERB
fuelectenerg-3675	261	8	by	by	ADP
fuelectenerg-3675	261	9	equations	equation	NOUN
fuelectenerg-3675	261	10	(	(	PUNCT
fuelectenerg-3675	261	11	10	10	NUM
fuelectenerg-3675	261	12	)	)	PUNCT
fuelectenerg-3675	261	13	to	to	ADP
fuelectenerg-3675	261	14	(	(	PUNCT
fuelectenerg-3675	261	15	14	14	NUM
fuelectenerg-3675	261	16	)	)	PUNCT
fuelectenerg-3675	261	17	need	need	VERB
fuelectenerg-3675	261	18	to	to	PART
fuelectenerg-3675	261	19	be	be	AUX
fuelectenerg-3675	261	20	validated	validate	VERB
fuelectenerg-3675	261	21	through	through	ADP
fuelectenerg-3675	261	22	numerous	numerous	ADJ
fuelectenerg-3675	261	23	experiments	experiment	NOUN
fuelectenerg-3675	261	24	in	in	ADP
fuelectenerg-3675	261	25	which	which	PRON
fuelectenerg-3675	261	26	different	different	ADJ
fuelectenerg-3675	261	27	magnetic	magnetic	ADJ
fuelectenerg-3675	261	28	materials	material	NOUN
fuelectenerg-3675	261	29	should	should	AUX
fuelectenerg-3675	261	30	be	be	AUX
fuelectenerg-3675	261	31	used	use	VERB
fuelectenerg-3675	261	32	.	.	PUNCT
fuelectenerg-3675	262	1	also	also	ADV
fuelectenerg-3675	262	2	,	,	PUNCT
fuelectenerg-3675	262	3	dimensions	dimension	NOUN
fuelectenerg-3675	262	4	of	of	ADP
fuelectenerg-3675	262	5	magnetic	magnetic	ADJ
fuelectenerg-3675	262	6	samples	sample	NOUN
fuelectenerg-3675	262	7	need	need	VERB
fuelectenerg-3675	262	8	to	to	PART
fuelectenerg-3675	262	9	be	be	AUX
fuelectenerg-3675	262	10	varied	varied	ADJ
fuelectenerg-3675	262	11	,	,	PUNCT
fuelectenerg-3675	262	12	as	as	ADV
fuelectenerg-3675	262	13	well	well	ADV
fuelectenerg-3675	262	14	as	as	ADP
fuelectenerg-3675	262	15	frequency	frequency	NOUN
fuelectenerg-3675	262	16	of	of	ADP
fuelectenerg-3675	262	17	excitation	excitation	NOUN
fuelectenerg-3675	262	18	current	current	ADJ
fuelectenerg-3675	262	19	and	and	CCONJ
fuelectenerg-3675	262	20	its	its	PRON
fuelectenerg-3675	262	21	shape	shape	NOUN
fuelectenerg-3675	262	22	(	(	PUNCT
fuelectenerg-3675	262	23	sinusoidal	sinusoidal	NOUN
fuelectenerg-3675	262	24	,	,	PUNCT
fuelectenerg-3675	262	25	triangular	triangular	NOUN
fuelectenerg-3675	262	26	and	and	CCONJ
fuelectenerg-3675	262	27	other	other	ADJ
fuelectenerg-3675	262	28	)	)	PUNCT
fuelectenerg-3675	262	29	.	.	PUNCT
fuelectenerg-3675	263	1	the	the	DET
fuelectenerg-3675	263	2	main	main	ADJ
fuelectenerg-3675	263	3	purpose	purpose	NOUN
fuelectenerg-3675	263	4	of	of	ADP
fuelectenerg-3675	263	5	the	the	DET
fuelectenerg-3675	263	6	calibrated	calibrate	VERB
fuelectenerg-3675	263	7	magnetometer	magnetometer	NOUN
fuelectenerg-3675	263	8	is	be	AUX
fuelectenerg-3675	263	9	to	to	PART
fuelectenerg-3675	263	10	obtain	obtain	VERB
fuelectenerg-3675	263	11	instantly	instantly	ADV
fuelectenerg-3675	263	12	the	the	DET
fuelectenerg-3675	263	13	hysteresis	hysteresis	NOUN
fuelectenerg-3675	263	14	loop	loop	NOUN
fuelectenerg-3675	263	15	of	of	ADP
fuelectenerg-3675	263	16	some	some	DET
fuelectenerg-3675	263	17	ferromagnetic	ferromagnetic	ADJ
fuelectenerg-3675	263	18	sample	sample	NOUN
fuelectenerg-3675	263	19	from	from	ADP
fuelectenerg-3675	263	20	calculated	calculate	VERB
fuelectenerg-3675	263	21	time	time	NOUN
fuelectenerg-3675	263	22	waveforms	waveform	NOUN
fuelectenerg-3675	263	23	of	of	ADP
fuelectenerg-3675	263	24	the	the	DET
fuelectenerg-3675	263	25	magnetic	magnetic	ADJ
fuelectenerg-3675	263	26	flux	flux	NOUN
fuelectenerg-3675	263	27	density	density	NOUN
fuelectenerg-3675	263	28	(	(	PUNCT
fuelectenerg-3675	263	29	or	or	CCONJ
fuelectenerg-3675	263	30	magnetisation	magnetisation	NOUN
fuelectenerg-3675	263	31	)	)	PUNCT
fuelectenerg-3675	263	32	and	and	CCONJ
fuelectenerg-3675	263	33	the	the	DET
fuelectenerg-3675	263	34	magnetic	magnetic	ADJ
fuelectenerg-3675	263	35	field	field	NOUN
fuelectenerg-3675	263	36	.	.	PUNCT
fuelectenerg-3675	264	1	it	it	PRON
fuelectenerg-3675	264	2	can	can	AUX
fuelectenerg-3675	264	3	be	be	AUX
fuelectenerg-3675	264	4	used	use	VERB
fuelectenerg-3675	264	5	for	for	ADP
fuelectenerg-3675	264	6	parallel	parallel	ADJ
fuelectenerg-3675	264	7	comparison	comparison	NOUN
fuelectenerg-3675	264	8	of	of	ADP
fuelectenerg-3675	264	9	the	the	DET
fuelectenerg-3675	264	10	hysteresis	hysteresis	NOUN
fuelectenerg-3675	264	11	loops	loop	VERB
fuelectenerg-3675	264	12	up	up	ADP
fuelectenerg-3675	264	13	to	to	PART
fuelectenerg-3675	264	14	four	four	NUM
fuelectenerg-3675	264	15	samples	sample	NOUN
fuelectenerg-3675	264	16	.	.	PUNCT
fuelectenerg-3675	265	1	samples	sample	NOUN
fuelectenerg-3675	265	2	can	can	AUX
fuelectenerg-3675	265	3	be	be	AUX
fuelectenerg-3675	265	4	made	make	VERB
fuelectenerg-3675	265	5	from	from	ADP
fuelectenerg-3675	265	6	different	different	ADJ
fuelectenerg-3675	265	7	materials	material	NOUN
fuelectenerg-3675	265	8	with	with	ADP
fuelectenerg-3675	265	9	the	the	DET
fuelectenerg-3675	265	10	same	same	ADJ
fuelectenerg-3675	265	11	dimensions	dimension	NOUN
fuelectenerg-3675	265	12	or	or	CCONJ
fuelectenerg-3675	265	13	from	from	ADP
fuelectenerg-3675	265	14	one	one	NUM
fuelectenerg-3675	265	15	material	material	NOUN
fuelectenerg-3675	265	16	with	with	ADP
fuelectenerg-3675	265	17	different	different	ADJ
fuelectenerg-3675	265	18	dimensions	dimension	NOUN
fuelectenerg-3675	265	19	.	.	PUNCT
fuelectenerg-3675	266	1	if	if	SCONJ
fuelectenerg-3675	266	2	all	all	DET
fuelectenerg-3675	266	3	samples	sample	NOUN
fuelectenerg-3675	266	4	are	be	AUX
fuelectenerg-3675	266	5	made	make	VERB
fuelectenerg-3675	266	6	from	from	ADP
fuelectenerg-3675	266	7	one	one	NUM
fuelectenerg-3675	266	8	material	material	NOUN
fuelectenerg-3675	266	9	and	and	CCONJ
fuelectenerg-3675	266	10	have	have	VERB
fuelectenerg-3675	266	11	the	the	DET
fuelectenerg-3675	266	12	same	same	ADJ
fuelectenerg-3675	266	13	dimensions	dimension	NOUN
fuelectenerg-3675	266	14	,	,	PUNCT
fuelectenerg-3675	266	15	one	one	NUM
fuelectenerg-3675	266	16	sample	sample	NOUN
fuelectenerg-3675	266	17	can	can	AUX
fuelectenerg-3675	266	18	be	be	AUX
fuelectenerg-3675	266	19	used	use	VERB
fuelectenerg-3675	266	20	as	as	ADP
fuelectenerg-3675	266	21	a	a	DET
fuelectenerg-3675	266	22	reference	reference	NOUN
fuelectenerg-3675	266	23	sample	sample	NOUN
fuelectenerg-3675	266	24	while	while	SCONJ
fuelectenerg-3675	266	25	the	the	DET
fuelectenerg-3675	266	26	others	other	NOUN
fuelectenerg-3675	266	27	can	can	AUX
fuelectenerg-3675	266	28	be	be	AUX
fuelectenerg-3675	266	29	checked	check	VERB
fuelectenerg-3675	266	30	against	against	ADP
fuelectenerg-3675	266	31	the	the	DET
fuelectenerg-3675	266	32	reference	reference	NOUN
fuelectenerg-3675	266	33	and	and	CCONJ
fuelectenerg-3675	266	34	classified	classify	VERB
fuelectenerg-3675	266	35	according	accord	VERB
fuelectenerg-3675	266	36	to	to	ADP
fuelectenerg-3675	266	37	the	the	DET
fuelectenerg-3675	266	38	predefined	predefine	VERB
fuelectenerg-3675	266	39	criteria	criterion	NOUN
fuelectenerg-3675	266	40	.	.	PUNCT
fuelectenerg-3675	267	1	the	the	DET
fuelectenerg-3675	267	2	magnetometer	magnetometer	NOUN
fuelectenerg-3675	267	3	can	can	AUX
fuelectenerg-3675	267	4	operate	operate	VERB
fuelectenerg-3675	267	5	with	with	ADP
fuelectenerg-3675	267	6	different	different	ADJ
fuelectenerg-3675	267	7	frequencies	frequency	NOUN
fuelectenerg-3675	267	8	of	of	ADP
fuelectenerg-3675	267	9	the	the	DET
fuelectenerg-3675	267	10	magnetising	magnetising	NOUN
fuelectenerg-3675	267	11	current	current	NOUN
fuelectenerg-3675	267	12	and	and	CCONJ
fuelectenerg-3675	267	13	with	with	ADP
fuelectenerg-3675	267	14	different	different	ADJ
fuelectenerg-3675	267	15	shapes	shape	NOUN
fuelectenerg-3675	267	16	of	of	ADP
fuelectenerg-3675	267	17	its	its	PRON
fuelectenerg-3675	267	18	time	time	NOUN
fuelectenerg-3675	267	19	waveform	waveform	NOUN
fuelectenerg-3675	267	20	.	.	PUNCT
fuelectenerg-3675	268	1	it	it	PRON
fuelectenerg-3675	268	2	should	should	AUX
fuelectenerg-3675	268	3	be	be	AUX
fuelectenerg-3675	268	4	taken	take	VERB
fuelectenerg-3675	268	5	into	into	ADP
fuelectenerg-3675	268	6	account	account	NOUN
fuelectenerg-3675	268	7	that	that	SCONJ
fuelectenerg-3675	268	8	the	the	DET
fuelectenerg-3675	268	9	voltage	voltage	NOUN
fuelectenerg-3675	268	10	induced	induce	VERB
fuelectenerg-3675	268	11	in	in	ADP
fuelectenerg-3675	268	12	pickup	pickup	ADJ
fuelectenerg-3675	268	13	coils	coil	NOUN
fuelectenerg-3675	268	14	should	should	AUX
fuelectenerg-3675	268	15	not	not	PART
fuelectenerg-3675	268	16	exceed	exceed	VERB
fuelectenerg-3675	268	17	a	a	DET
fuelectenerg-3675	268	18	voltage	voltage	NOUN
fuelectenerg-3675	268	19	range	range	NOUN
fuelectenerg-3675	268	20	of	of	ADP
fuelectenerg-3675	268	21	the	the	DET
fuelectenerg-3675	268	22	data	data	NOUN
fuelectenerg-3675	268	23	acquisition	acquisition	NOUN
fuelectenerg-3675	268	24	card	card	NOUN
fuelectenerg-3675	268	25	(	(	PUNCT
fuelectenerg-3675	268	26	usually	usually	ADV
fuelectenerg-3675	268	27	10	10	NUM
fuelectenerg-3675	268	28	v	v	NOUN
fuelectenerg-3675	268	29	)	)	PUNCT
fuelectenerg-3675	268	30	.	.	PUNCT
fuelectenerg-3675	269	1	the	the	DET
fuelectenerg-3675	269	2	induced	induce	VERB
fuelectenerg-3675	269	3	voltage	voltage	NOUN
fuelectenerg-3675	269	4	increases	increase	NOUN
fuelectenerg-3675	269	5	with	with	ADP
fuelectenerg-3675	269	6	the	the	DET
fuelectenerg-3675	269	7	increasing	increasing	NOUN
fuelectenerg-3675	269	8	of	of	ADP
fuelectenerg-3675	269	9	the	the	DET
fuelectenerg-3675	269	10	frequency	frequency	NOUN
fuelectenerg-3675	269	11	of	of	ADP
fuelectenerg-3675	269	12	the	the	DET
fuelectenerg-3675	269	13	magnetising	magnetising	PROPN
fuelectenerg-3675	269	14	current	current	NOUN
fuelectenerg-3675	269	15	.	.	PUNCT
fuelectenerg-3675	270	1	sometimes	sometimes	ADV
fuelectenerg-3675	270	2	,	,	PUNCT
fuelectenerg-3675	270	3	it	it	PRON
fuelectenerg-3675	270	4	is	be	AUX
fuelectenerg-3675	270	5	necessary	necessary	ADJ
fuelectenerg-3675	270	6	to	to	PART
fuelectenerg-3675	270	7	use	use	VERB
fuelectenerg-3675	270	8	voltage	voltage	NOUN
fuelectenerg-3675	270	9	dividers	divider	NOUN
fuelectenerg-3675	270	10	to	to	PART
fuelectenerg-3675	270	11	keep	keep	VERB
fuelectenerg-3675	270	12	the	the	DET
fuelectenerg-3675	270	13	induced	induced	ADJ
fuelectenerg-3675	270	14	voltage	voltage	NOUN
fuelectenerg-3675	270	15	in	in	ADP
fuelectenerg-3675	270	16	the	the	DET
fuelectenerg-3675	270	17	desired	desire	VERB
fuelectenerg-3675	270	18	range	range	NOUN
fuelectenerg-3675	270	19	.	.	PUNCT
fuelectenerg-3675	271	1	at	at	ADP
fuelectenerg-3675	271	2	very	very	ADV
fuelectenerg-3675	271	3	low	low	ADJ
fuelectenerg-3675	271	4	frequencies	frequency	NOUN
fuelectenerg-3675	271	5	(	(	PUNCT
fuelectenerg-3675	271	6	below	below	ADP
fuelectenerg-3675	271	7	1	1	NUM
fuelectenerg-3675	271	8	hz	hz	NOUN
fuelectenerg-3675	271	9	)	)	PUNCT
fuelectenerg-3675	271	10	,	,	PUNCT
fuelectenerg-3675	271	11	the	the	DET
fuelectenerg-3675	271	12	amplitude	amplitude	NOUN
fuelectenerg-3675	271	13	of	of	ADP
fuelectenerg-3675	271	14	the	the	DET
fuelectenerg-3675	271	15	induced	induced	ADJ
fuelectenerg-3675	271	16	voltage	voltage	NOUN
fuelectenerg-3675	271	17	is	be	AUX
fuelectenerg-3675	271	18	relatively	relatively	ADV
fuelectenerg-3675	271	19	small	small	ADJ
fuelectenerg-3675	271	20	which	which	PRON
fuelectenerg-3675	271	21	results	result	VERB
fuelectenerg-3675	271	22	in	in	ADP
fuelectenerg-3675	271	23	a	a	DET
fuelectenerg-3675	271	24	deterioration	deterioration	NOUN
fuelectenerg-3675	271	25	of	of	ADP
fuelectenerg-3675	271	26	the	the	DET
fuelectenerg-3675	271	27	signal	signal	NOUN
fuelectenerg-3675	271	28	-	-	PUNCT
fuelectenerg-3675	271	29	tonoise	tonoise	NOUN
fuelectenerg-3675	271	30	ratio	ratio	NOUN
fuelectenerg-3675	271	31	.	.	PUNCT
fuelectenerg-3675	272	1	in	in	ADP
fuelectenerg-3675	272	2	such	such	ADJ
fuelectenerg-3675	272	3	cases	case	NOUN
fuelectenerg-3675	272	4	,	,	PUNCT
fuelectenerg-3675	272	5	averaging	average	VERB
fuelectenerg-3675	272	6	of	of	ADP
fuelectenerg-3675	272	7	measured	measured	ADJ
fuelectenerg-3675	272	8	signals	signal	NOUN
fuelectenerg-3675	272	9	is	be	AUX
fuelectenerg-3675	272	10	useful	useful	ADJ
fuelectenerg-3675	272	11	[	[	X
fuelectenerg-3675	272	12	8	8	NUM
fuelectenerg-3675	272	13	]	]	SYM
fuelectenerg-3675	272	14	.	.	PUNCT
fuelectenerg-3675	273	1	5	5	X
fuelectenerg-3675	273	2	.	.	X
fuelectenerg-3675	273	3	conclusion	conclusion	NOUN
fuelectenerg-3675	273	4	the	the	DET
fuelectenerg-3675	273	5	paper	paper	NOUN
fuelectenerg-3675	273	6	gives	give	VERB
fuelectenerg-3675	273	7	a	a	DET
fuelectenerg-3675	273	8	brief	brief	ADJ
fuelectenerg-3675	273	9	description	description	NOUN
fuelectenerg-3675	273	10	of	of	ADP
fuelectenerg-3675	273	11	ac	ac	PROPN
fuelectenerg-3675	273	12	induction	induction	PROPN
fuelectenerg-3675	273	13	magnetometer	magnetometer	NOUN
fuelectenerg-3675	273	14	,	,	PUNCT
fuelectenerg-3675	273	15	its	its	PRON
fuelectenerg-3675	273	16	construction	construction	NOUN
fuelectenerg-3675	273	17	and	and	CCONJ
fuelectenerg-3675	273	18	working	working	NOUN
fuelectenerg-3675	273	19	principle	principle	NOUN
fuelectenerg-3675	273	20	,	,	PUNCT
fuelectenerg-3675	273	21	and	and	CCONJ
fuelectenerg-3675	273	22	emphasises	emphasise	VERB
fuelectenerg-3675	273	23	its	its	PRON
fuelectenerg-3675	273	24	rising	rise	VERB
fuelectenerg-3675	273	25	importance	importance	NOUN
fuelectenerg-3675	273	26	in	in	ADP
fuelectenerg-3675	273	27	complex	complex	ADJ
fuelectenerg-3675	273	28	measurements	measurement	NOUN
fuelectenerg-3675	273	29	with	with	ADP
fuelectenerg-3675	273	30	ferromagnetic	ferromagnetic	ADJ
fuelectenerg-3675	273	31	materials	material	NOUN
fuelectenerg-3675	273	32	.	.	PUNCT
fuelectenerg-3675	274	1	the	the	DET
fuelectenerg-3675	274	2	paper	paper	NOUN
fuelectenerg-3675	274	3	describes	describe	VERB
fuelectenerg-3675	274	4	a	a	DET
fuelectenerg-3675	274	5	calibration	calibration	NOUN
fuelectenerg-3675	274	6	procedure	procedure	NOUN
fuelectenerg-3675	274	7	of	of	ADP
fuelectenerg-3675	274	8	ac	ac	PROPN
fuelectenerg-3675	274	9	induction	induction	NOUN
fuelectenerg-3675	274	10	magnetometer	magnetometer	NOUN
fuelectenerg-3675	274	11	.	.	PUNCT
fuelectenerg-3675	275	1	it	it	PRON
fuelectenerg-3675	275	2	has	have	AUX
fuelectenerg-3675	275	3	been	be	AUX
fuelectenerg-3675	275	4	performed	perform	VERB
fuelectenerg-3675	275	5	on	on	ADP
fuelectenerg-3675	275	6	the	the	DET
fuelectenerg-3675	275	7	coil	coil	NOUN
fuelectenerg-3675	275	8	systems	system	NOUN
fuelectenerg-3675	275	9	of	of	ADP
fuelectenerg-3675	275	10	ferrotester	ferrotester	NOUN
fuelectenerg-3675	275	11	2738	2738	NUM
fuelectenerg-3675	275	12	/	/	SYM
fuelectenerg-3675	275	13	s-3	s-3	NOUN
fuelectenerg-3675	275	14	.	.	PUNCT
fuelectenerg-3675	276	1	initially	initially	ADV
fuelectenerg-3675	276	2	,	,	PUNCT
fuelectenerg-3675	276	3	measurements	measurement	NOUN
fuelectenerg-3675	276	4	have	have	AUX
fuelectenerg-3675	276	5	been	be	AUX
fuelectenerg-3675	276	6	performed	perform	VERB
fuelectenerg-3675	276	7	on	on	ADP
fuelectenerg-3675	276	8	the	the	DET
fuelectenerg-3675	276	9	large	large	ADJ
fuelectenerg-3675	276	10	-	-	PUNCT
fuelectenerg-3675	276	11	diameter	diameter	NOUN
fuelectenerg-3675	276	12	multilayer	multilayer	NOUN
fuelectenerg-3675	276	13	solenoid	solenoid	NOUN
fuelectenerg-3675	276	14	in	in	ADP
fuelectenerg-3675	276	15	order	order	NOUN
fuelectenerg-3675	276	16	to	to	PART
fuelectenerg-3675	276	17	investigate	investigate	VERB
fuelectenerg-3675	276	18	a	a	DET
fuelectenerg-3675	276	19	homogeneity	homogeneity	NOUN
fuelectenerg-3675	276	20	of	of	ADP
fuelectenerg-3675	276	21	the	the	DET
fuelectenerg-3675	276	22	generated	generate	VERB
fuelectenerg-3675	276	23	magnetic	magnetic	ADJ
fuelectenerg-3675	276	24	field	field	NOUN
fuelectenerg-3675	276	25	.	.	PUNCT
fuelectenerg-3675	277	1	it	it	PRON
fuelectenerg-3675	277	2	has	have	AUX
fuelectenerg-3675	277	3	been	be	AUX
fuelectenerg-3675	277	4	found	find	VERB
fuelectenerg-3675	277	5	that	that	SCONJ
fuelectenerg-3675	277	6	the	the	DET
fuelectenerg-3675	277	7	variation	variation	NOUN
fuelectenerg-3675	277	8	of	of	ADP
fuelectenerg-3675	277	9	the	the	DET
fuelectenerg-3675	277	10	magnetic	magnetic	ADJ
fuelectenerg-3675	277	11	field	field	NOUN
fuelectenerg-3675	277	12	in	in	ADP
fuelectenerg-3675	277	13	the	the	DET
fuelectenerg-3675	277	14	homogeneity	homogeneity	NOUN
fuelectenerg-3675	277	15	zone	zone	NOUN
fuelectenerg-3675	277	16	was	be	AUX
fuelectenerg-3675	277	17	less	less	ADJ
fuelectenerg-3675	277	18	than	than	ADP
fuelectenerg-3675	277	19	1	1	NUM
fuelectenerg-3675	277	20	%	%	NOUN
fuelectenerg-3675	277	21	of	of	ADP
fuelectenerg-3675	277	22	its	its	PRON
fuelectenerg-3675	277	23	maximum	maximum	ADJ
fuelectenerg-3675	277	24	value	value	NOUN
fuelectenerg-3675	277	25	.	.	PUNCT
fuelectenerg-3675	278	1	this	this	DET
fuelectenerg-3675	278	2	homogeneity	homogeneity	NOUN
fuelectenerg-3675	278	3	zone	zone	NOUN
fuelectenerg-3675	278	4	covers	cover	VERB
fuelectenerg-3675	278	5	one	one	NUM
fuelectenerg-3675	278	6	third	third	NOUN
fuelectenerg-3675	278	7	of	of	ADP
fuelectenerg-3675	278	8	the	the	DET
fuelectenerg-3675	278	9	solenoid	solenoid	ADJ
fuelectenerg-3675	278	10	volume	volume	NOUN
fuelectenerg-3675	278	11	(	(	PUNCT
fuelectenerg-3675	278	12	its	its	PRON
fuelectenerg-3675	278	13	central	central	ADJ
fuelectenerg-3675	278	14	part	part	NOUN
fuelectenerg-3675	278	15	)	)	PUNCT
fuelectenerg-3675	278	16	.	.	PUNCT
fuelectenerg-3675	279	1	the	the	DET
fuelectenerg-3675	279	2	calibration	calibration	NOUN
fuelectenerg-3675	279	3	constant	constant	ADJ
fuelectenerg-3675	279	4	of	of	ADP
fuelectenerg-3675	279	5	the	the	DET
fuelectenerg-3675	279	6	large	large	ADJ
fuelectenerg-3675	279	7	solenoid	solenoid	NOUN
fuelectenerg-3675	279	8	has	have	AUX
fuelectenerg-3675	279	9	been	be	AUX
fuelectenerg-3675	279	10	determined	determine	VERB
fuelectenerg-3675	279	11	using	use	VERB
fuelectenerg-3675	279	12	measurements	measurement	NOUN
fuelectenerg-3675	279	13	.	.	PUNCT
fuelectenerg-3675	280	1	further	far	ADV
fuelectenerg-3675	280	2	,	,	PUNCT
fuelectenerg-3675	280	3	using	use	VERB
fuelectenerg-3675	280	4	numerous	numerous	ADJ
fuelectenerg-3675	280	5	measurements	measurement	NOUN
fuelectenerg-3675	280	6	the	the	DET
fuelectenerg-3675	280	7	calibration	calibration	NOUN
fuelectenerg-3675	280	8	constants	constant	NOUN
fuelectenerg-3675	280	9	for	for	ADP
fuelectenerg-3675	280	10	all	all	DET
fuelectenerg-3675	280	11	investigated	investigate	VERB
fuelectenerg-3675	280	12	pickup	pickup	NOUN
fuelectenerg-3675	280	13	coils	coil	NOUN
fuelectenerg-3675	280	14	have	have	AUX
fuelectenerg-3675	280	15	been	be	AUX
fuelectenerg-3675	280	16	determined	determine	VERB
fuelectenerg-3675	280	17	.	.	PUNCT
fuelectenerg-3675	281	1	626	626	NUM
fuelectenerg-3675	281	2	b.	b.	PROPN
fuelectenerg-3675	281	3	koprivica	koprivica	PROPN
fuelectenerg-3675	281	4	,	,	PUNCT
fuelectenerg-3675	281	5	m.	m.	NOUN
fuelectenerg-3675	281	6	šućurović	šućurović	PROPN
fuelectenerg-3675	281	7	,	,	PUNCT
fuelectenerg-3675	281	8	a.	a.	NOUN
fuelectenerg-3675	281	9	milovanović	milovanović	NOUN
fuelectenerg-3675	281	10	a	a	DET
fuelectenerg-3675	281	11	detailed	detailed	ADJ
fuelectenerg-3675	281	12	calculation	calculation	NOUN
fuelectenerg-3675	281	13	of	of	ADP
fuelectenerg-3675	281	14	measurement	measurement	NOUN
fuelectenerg-3675	281	15	uncertainty	uncertainty	NOUN
fuelectenerg-3675	281	16	of	of	ADP
fuelectenerg-3675	281	17	hall	hall	NOUN
fuelectenerg-3675	281	18	sensor	sensor	NOUN
fuelectenerg-3675	281	19	sensitivity	sensitivity	NOUN
fuelectenerg-3675	281	20	is	be	AUX
fuelectenerg-3675	281	21	also	also	ADV
fuelectenerg-3675	281	22	presented	present	VERB
fuelectenerg-3675	281	23	in	in	ADP
fuelectenerg-3675	281	24	the	the	DET
fuelectenerg-3675	281	25	paper	paper	NOUN
fuelectenerg-3675	281	26	.	.	PUNCT
fuelectenerg-3675	282	1	it	it	PRON
fuelectenerg-3675	282	2	has	have	AUX
fuelectenerg-3675	282	3	been	be	AUX
fuelectenerg-3675	282	4	found	find	VERB
fuelectenerg-3675	282	5	that	that	SCONJ
fuelectenerg-3675	282	6	the	the	DET
fuelectenerg-3675	282	7	relative	relative	ADJ
fuelectenerg-3675	282	8	expanded	expand	VERB
fuelectenerg-3675	282	9	uncertainty	uncertainty	NOUN
fuelectenerg-3675	282	10	amounts	amount	VERB
fuelectenerg-3675	282	11	1.08	1.08	NUM
fuelectenerg-3675	282	12	%	%	NOUN
fuelectenerg-3675	282	13	at	at	ADP
fuelectenerg-3675	282	14	magnetic	magnetic	ADJ
fuelectenerg-3675	282	15	flux	flux	NOUN
fuelectenerg-3675	282	16	density	density	NOUN
fuelectenerg-3675	282	17	of	of	ADP
fuelectenerg-3675	282	18	10	10	NUM
fuelectenerg-3675	282	19	mt	mt	PROPN
fuelectenerg-3675	282	20	.	.	PUNCT
fuelectenerg-3675	283	1	the	the	DET
fuelectenerg-3675	283	2	possible	possible	ADJ
fuelectenerg-3675	283	3	ways	way	NOUN
fuelectenerg-3675	283	4	to	to	PART
fuelectenerg-3675	283	5	use	use	VERB
fuelectenerg-3675	283	6	a	a	DET
fuelectenerg-3675	283	7	calibrated	calibrate	VERB
fuelectenerg-3675	283	8	magnetometer	magnetometer	NOUN
fuelectenerg-3675	283	9	for	for	ADP
fuelectenerg-3675	283	10	future	future	ADJ
fuelectenerg-3675	283	11	measurements	measurement	NOUN
fuelectenerg-3675	283	12	have	have	AUX
fuelectenerg-3675	283	13	been	be	AUX
fuelectenerg-3675	283	14	described	describe	VERB
fuelectenerg-3675	283	15	.	.	PUNCT
fuelectenerg-3675	284	1	the	the	DET
fuelectenerg-3675	284	2	method	method	NOUN
fuelectenerg-3675	284	3	for	for	ADP
fuelectenerg-3675	284	4	determining	determine	VERB
fuelectenerg-3675	284	5	time	time	NOUN
fuelectenerg-3675	284	6	waveforms	waveform	NOUN
fuelectenerg-3675	284	7	of	of	ADP
fuelectenerg-3675	284	8	the	the	DET
fuelectenerg-3675	284	9	magnetic	magnetic	ADJ
fuelectenerg-3675	284	10	field	field	NOUN
fuelectenerg-3675	284	11	and	and	CCONJ
fuelectenerg-3675	284	12	the	the	DET
fuelectenerg-3675	284	13	magnetic	magnetic	ADJ
fuelectenerg-3675	284	14	flux	flux	NOUN
fuelectenerg-3675	284	15	density	density	NOUN
fuelectenerg-3675	284	16	(	(	PUNCT
fuelectenerg-3675	284	17	or	or	CCONJ
fuelectenerg-3675	284	18	magnetisation	magnetisation	NOUN
fuelectenerg-3675	284	19	)	)	PUNCT
fuelectenerg-3675	284	20	from	from	ADP
fuelectenerg-3675	284	21	the	the	DET
fuelectenerg-3675	284	22	measured	measure	VERB
fuelectenerg-3675	284	23	voltage	voltage	NOUN
fuelectenerg-3675	284	24	induced	induce	VERB
fuelectenerg-3675	284	25	in	in	ADP
fuelectenerg-3675	284	26	pickup	pickup	NOUN
fuelectenerg-3675	284	27	coils	coil	NOUN
fuelectenerg-3675	284	28	and	and	CCONJ
fuelectenerg-3675	284	29	the	the	DET
fuelectenerg-3675	284	30	calibration	calibration	NOUN
fuelectenerg-3675	284	31	constants	constant	NOUN
fuelectenerg-3675	284	32	has	have	AUX
fuelectenerg-3675	284	33	been	be	AUX
fuelectenerg-3675	284	34	presented	present	VERB
fuelectenerg-3675	284	35	.	.	PUNCT
fuelectenerg-3675	285	1	a	a	DET
fuelectenerg-3675	285	2	hysteresis	hysteresis	NOUN
fuelectenerg-3675	285	3	loop	loop	NOUN
fuelectenerg-3675	285	4	of	of	ADP
fuelectenerg-3675	285	5	a	a	DET
fuelectenerg-3675	285	6	ferromagnetic	ferromagnetic	ADJ
fuelectenerg-3675	285	7	sample	sample	NOUN
fuelectenerg-3675	285	8	can	can	AUX
fuelectenerg-3675	285	9	be	be	AUX
fuelectenerg-3675	285	10	easily	easily	ADV
fuelectenerg-3675	285	11	obtained	obtain	VERB
fuelectenerg-3675	285	12	from	from	ADP
fuelectenerg-3675	285	13	these	these	DET
fuelectenerg-3675	285	14	waveforms	waveform	NOUN
fuelectenerg-3675	285	15	.	.	PUNCT
fuelectenerg-3675	286	1	the	the	DET
fuelectenerg-3675	286	2	magnetometer	magnetometer	NOUN
fuelectenerg-3675	286	3	can	can	AUX
fuelectenerg-3675	286	4	be	be	AUX
fuelectenerg-3675	286	5	used	use	VERB
fuelectenerg-3675	286	6	for	for	ADP
fuelectenerg-3675	286	7	simultaneous	simultaneous	ADJ
fuelectenerg-3675	286	8	testing	testing	NOUN
fuelectenerg-3675	286	9	of	of	ADP
fuelectenerg-3675	286	10	four	four	NUM
fuelectenerg-3675	286	11	samples	sample	NOUN
fuelectenerg-3675	286	12	of	of	ADP
fuelectenerg-3675	286	13	one	one	NUM
fuelectenerg-3675	286	14	material	material	NOUN
fuelectenerg-3675	286	15	or	or	CCONJ
fuelectenerg-3675	286	16	different	different	ADJ
fuelectenerg-3675	286	17	materials	material	NOUN
fuelectenerg-3675	286	18	.	.	PUNCT
fuelectenerg-3675	287	1	two	two	NUM
fuelectenerg-3675	287	2	side	side	ADJ
fuelectenerg-3675	287	3	effects	effect	NOUN
fuelectenerg-3675	287	4	that	that	PRON
fuelectenerg-3675	287	5	can	can	AUX
fuelectenerg-3675	287	6	produce	produce	VERB
fuelectenerg-3675	287	7	errors	error	NOUN
fuelectenerg-3675	287	8	in	in	ADP
fuelectenerg-3675	287	9	such	such	ADJ
fuelectenerg-3675	287	10	measurements	measurement	NOUN
fuelectenerg-3675	287	11	were	be	AUX
fuelectenerg-3675	287	12	discussed	discuss	VERB
fuelectenerg-3675	287	13	.	.	PUNCT
fuelectenerg-3675	288	1	some	some	DET
fuelectenerg-3675	288	2	practical	practical	ADJ
fuelectenerg-3675	288	3	notes	note	NOUN
fuelectenerg-3675	288	4	on	on	ADP
fuelectenerg-3675	288	5	the	the	DET
fuelectenerg-3675	288	6	measurements	measurement	NOUN
fuelectenerg-3675	288	7	with	with	ADP
fuelectenerg-3675	288	8	the	the	DET
fuelectenerg-3675	288	9	calibrated	calibrate	VERB
fuelectenerg-3675	288	10	magnetometer	magnetometer	NOUN
fuelectenerg-3675	288	11	at	at	ADP
fuelectenerg-3675	288	12	different	different	ADJ
fuelectenerg-3675	288	13	frequencies	frequency	NOUN
fuelectenerg-3675	288	14	of	of	ADP
fuelectenerg-3675	288	15	the	the	DET
fuelectenerg-3675	288	16	magnetising	magnetising	NOUN
fuelectenerg-3675	288	17	current	current	NOUN
fuelectenerg-3675	288	18	have	have	AUX
fuelectenerg-3675	288	19	been	be	AUX
fuelectenerg-3675	288	20	also	also	ADV
fuelectenerg-3675	288	21	given	give	VERB
fuelectenerg-3675	288	22	in	in	ADP
fuelectenerg-3675	288	23	the	the	DET
fuelectenerg-3675	288	24	paper	paper	NOUN
fuelectenerg-3675	288	25	.	.	PUNCT
fuelectenerg-3675	289	1	acknowledgement	acknowledgement	NOUN
fuelectenerg-3675	289	2	:	:	PUNCT
fuelectenerg-3675	289	3	this	this	DET
fuelectenerg-3675	289	4	paper	paper	NOUN
fuelectenerg-3675	289	5	has	have	AUX
fuelectenerg-3675	289	6	been	be	AUX
fuelectenerg-3675	289	7	supported	support	VERB
fuelectenerg-3675	289	8	by	by	ADP
fuelectenerg-3675	289	9	scientific	scientific	ADJ
fuelectenerg-3675	289	10	project	project	NOUN
fuelectenerg-3675	289	11	tr	tr	VERB
fuelectenerg-3675	289	12	33016	33016	NUM
fuelectenerg-3675	289	13	,	,	PUNCT
fuelectenerg-3675	289	14	financed	finance	VERB
fuelectenerg-3675	289	15	by	by	ADP
fuelectenerg-3675	289	16	the	the	DET
fuelectenerg-3675	289	17	ministry	ministry	PROPN
fuelectenerg-3675	289	18	of	of	ADP
fuelectenerg-3675	289	19	education	education	PROPN
fuelectenerg-3675	289	20	,	,	PUNCT
fuelectenerg-3675	289	21	science	science	NOUN
fuelectenerg-3675	289	22	and	and	CCONJ
fuelectenerg-3675	289	23	technological	technological	ADJ
fuelectenerg-3675	289	24	development	development	NOUN
fuelectenerg-3675	289	25	of	of	ADP
fuelectenerg-3675	289	26	the	the	DET
fuelectenerg-3675	289	27	republic	republic	NOUN
fuelectenerg-3675	289	28	of	of	ADP
fuelectenerg-3675	289	29	serbia	serbia	PROPN
fuelectenerg-3675	289	30	.	.	PUNCT
fuelectenerg-3675	290	1	references	reference	NOUN
fuelectenerg-3675	290	2	[	[	X
fuelectenerg-3675	290	3	1	1	NUM
fuelectenerg-3675	290	4	]	]	PUNCT
fuelectenerg-3675	290	5	b.	b.	PROPN
fuelectenerg-3675	290	6	koprivica	koprivica	PROPN
fuelectenerg-3675	290	7	,	,	PUNCT
fuelectenerg-3675	290	8	m.	m.	NOUN
fuelectenerg-3675	290	9	šućurović	šućurović	PROPN
fuelectenerg-3675	290	10	,	,	PUNCT
fuelectenerg-3675	290	11	n.	n.	PROPN
fuelectenerg-3675	290	12	jevtić	jevtić	PROPN
fuelectenerg-3675	290	13	,	,	PUNCT
fuelectenerg-3675	290	14	a.	a.	NOUN
fuelectenerg-3675	290	15	milovanović	milovanović	NOUN
fuelectenerg-3675	290	16	,	,	PUNCT
fuelectenerg-3675	290	17	"	"	PUNCT
fuelectenerg-3675	290	18	measurement	measurement	NOUN
fuelectenerg-3675	290	19	of	of	ADP
fuelectenerg-3675	290	20	magnetic	magnetic	ADJ
fuelectenerg-3675	290	21	flux	flux	NOUN
fuelectenerg-3675	290	22	density	density	NOUN
fuelectenerg-3675	290	23	of	of	ADP
fuelectenerg-3675	290	24	large	large	ADJ
fuelectenerg-3675	290	25	-	-	PUNCT
fuelectenerg-3675	290	26	diameter	diameter	NOUN
fuelectenerg-3675	290	27	multilayer	multilayer	NOUN
fuelectenerg-3675	290	28	solenoid	solenoid	NOUN
fuelectenerg-3675	290	29	"	"	PUNCT
fuelectenerg-3675	290	30	,	,	PUNCT
fuelectenerg-3675	290	31	in	in	ADP
fuelectenerg-3675	290	32	proceedings	proceeding	NOUN
fuelectenerg-3675	290	33	of	of	ADP
fuelectenerg-3675	290	34	the	the	DET
fuelectenerg-3675	290	35	13th	13th	ADJ
fuelectenerg-3675	290	36	international	international	ADJ
fuelectenerg-3675	290	37	conference	conference	NOUN
fuelectenerg-3675	290	38	on	on	ADP
fuelectenerg-3675	290	39	applied	applied	ADJ
fuelectenerg-3675	290	40	electromagnetics	electromagnetic	NOUN
fuelectenerg-3675	290	41	(	(	PUNCT
fuelectenerg-3675	290	42	пес	пес	ADJ
fuelectenerg-3675	290	43	2017	2017	NUM
fuelectenerg-3675	290	44	)	)	PUNCT
fuelectenerg-3675	290	45	,	,	PUNCT
fuelectenerg-3675	290	46	niš	niš	NOUN
fuelectenerg-3675	290	47	,	,	PUNCT
fuelectenerg-3675	290	48	serbia	serbia	PROPN
fuelectenerg-3675	290	49	,	,	PUNCT
fuelectenerg-3675	290	50	2017	2017	NUM
fuelectenerg-3675	290	51	,	,	PUNCT
fuelectenerg-3675	290	52	p.	p.	PROPN
fuelectenerg-3675	290	53	o5	o5	PROPN
fuelectenerg-3675	290	54	-	-	PUNCT
fuelectenerg-3675	290	55	2	2	NUM
fuelectenerg-3675	290	56	.	.	PUNCT
fuelectenerg-3675	291	1	[	[	X
fuelectenerg-3675	291	2	2	2	NUM
fuelectenerg-3675	291	3	]	]	X
fuelectenerg-3675	291	4	h.	h.	PROPN
fuelectenerg-3675	291	5	gavrila	gavrila	PROPN
fuelectenerg-3675	291	6	,	,	PUNCT
fuelectenerg-3675	291	7	v.	v.	PROPN
fuelectenerg-3675	291	8	manescu	manescu	PROPN
fuelectenerg-3675	291	9	(	(	PUNCT
fuelectenerg-3675	291	10	paltanea	paltanea	NOUN
fuelectenerg-3675	291	11	)	)	PUNCT
fuelectenerg-3675	291	12	,	,	PUNCT
fuelectenerg-3675	291	13	g.	g.	PROPN
fuelectenerg-3675	291	14	paltanea	paltanea	PROPN
fuelectenerg-3675	291	15	,	,	PUNCT
fuelectenerg-3675	291	16	g.	g.	PROPN
fuelectenerg-3675	291	17	scutaru	scutaru	PROPN
fuelectenerg-3675	291	18	,	,	PUNCT
fuelectenerg-3675	291	19	i.	i.	PROPN
fuelectenerg-3675	291	20	peter	peter	PROPN
fuelectenerg-3675	291	21	,	,	PUNCT
fuelectenerg-3675	291	22	"	"	PUNCT
fuelectenerg-3675	291	23	new	new	ADJ
fuelectenerg-3675	291	24	trends	trend	NOUN
fuelectenerg-3675	291	25	in	in	ADP
fuelectenerg-3675	291	26	energy	energy	NOUN
fuelectenerg-3675	291	27	efficient	efficient	ADJ
fuelectenerg-3675	291	28	electrical	electrical	ADJ
fuelectenerg-3675	291	29	machines	machine	NOUN
fuelectenerg-3675	291	30	"	"	PUNCT
fuelectenerg-3675	291	31	,	,	PUNCT
fuelectenerg-3675	291	32	procedia	procedia	PROPN
fuelectenerg-3675	291	33	engineering	engineering	NOUN
fuelectenerg-3675	291	34	,	,	PUNCT
fuelectenerg-3675	291	35	vol	vol	NOUN
fuelectenerg-3675	291	36	.	.	PROPN
fuelectenerg-3675	291	37	181	181	NUM
fuelectenerg-3675	291	38	,	,	PUNCT
fuelectenerg-3675	291	39	pp	pp	ADJ
fuelectenerg-3675	291	40	.	.	PUNCT
fuelectenerg-3675	292	1	568	568	NUM
fuelectenerg-3675	292	2	-	-	SYM
fuelectenerg-3675	292	3	574	574	NUM
fuelectenerg-3675	292	4	,	,	PUNCT
fuelectenerg-3675	292	5	2017	2017	NUM
fuelectenerg-3675	292	6	.	.	PUNCT
fuelectenerg-3675	293	1	[	[	X
fuelectenerg-3675	293	2	3	3	X
fuelectenerg-3675	293	3	]	]	X
fuelectenerg-3675	293	4	f.	f.	PROPN
fuelectenerg-3675	293	5	béron	béron	PROPN
fuelectenerg-3675	293	6	,	,	PUNCT
fuelectenerg-3675	293	7	g.	g.	PROPN
fuelectenerg-3675	293	8	soares	soares	PROPN
fuelectenerg-3675	293	9	,	,	PUNCT
fuelectenerg-3675	293	10	k.	k.	PROPN
fuelectenerg-3675	293	11	r.	r.	PROPN
fuelectenerg-3675	293	12	pirota	pirota	PROPN
fuelectenerg-3675	293	13	,	,	PUNCT
fuelectenerg-3675	293	14	"	"	PUNCT
fuelectenerg-3675	293	15	first	first	ADJ
fuelectenerg-3675	293	16	-	-	PUNCT
fuelectenerg-3675	293	17	order	order	NOUN
fuelectenerg-3675	293	18	reversal	reversal	NOUN
fuelectenerg-3675	293	19	curves	curve	NOUN
fuelectenerg-3675	293	20	acquired	acquire	VERB
fuelectenerg-3675	293	21	by	by	ADP
fuelectenerg-3675	293	22	a	a	DET
fuelectenerg-3675	293	23	high	high	ADJ
fuelectenerg-3675	293	24	precision	precision	NOUN
fuelectenerg-3675	293	25	ac	ac	PROPN
fuelectenerg-3675	293	26	induction	induction	PROPN
fuelectenerg-3675	293	27	magnetometer	magnetometer	NOUN
fuelectenerg-3675	293	28	"	"	PUNCT
fuelectenerg-3675	293	29	,	,	PUNCT
fuelectenerg-3675	293	30	review	review	NOUN
fuelectenerg-3675	293	31	of	of	ADP
fuelectenerg-3675	293	32	scientific	scientific	ADJ
fuelectenerg-3675	293	33	instruments	instrument	NOUN
fuelectenerg-3675	293	34	,	,	PUNCT
fuelectenerg-3675	293	35	vol	vol	NOUN
fuelectenerg-3675	293	36	.	.	PROPN
fuelectenerg-3675	293	37	82	82	NUM
fuelectenerg-3675	293	38	,	,	PUNCT
fuelectenerg-3675	293	39	no	no	INTJ
fuelectenerg-3675	293	40	.	.	NOUN
fuelectenerg-3675	293	41	6	6	NUM
fuelectenerg-3675	293	42	,	,	PUNCT
fuelectenerg-3675	293	43	p.	p.	NOUN
fuelectenerg-3675	293	44	063904	063904	NUM
fuelectenerg-3675	293	45	,	,	PUNCT
fuelectenerg-3675	293	46	june	june	PROPN
fuelectenerg-3675	293	47	2011	2011	NUM
fuelectenerg-3675	293	48	.	.	PUNCT
fuelectenerg-3675	294	1	[	[	X
fuelectenerg-3675	294	2	4	4	X
fuelectenerg-3675	294	3	]	]	PUNCT
fuelectenerg-3675	294	4	m.	m.	NOUN
fuelectenerg-3675	294	5	rivas	rivas	PROPN
fuelectenerg-3675	294	6	,	,	PUNCT
fuelectenerg-3675	294	7	p.	p.	PROPN
fuelectenerg-3675	294	8	gorria	gorria	PROPN
fuelectenerg-3675	294	9	,	,	PUNCT
fuelectenerg-3675	294	10	c.	c.	PROPN
fuelectenerg-3675	294	11	muñoz	muñoz	PROPN
fuelectenerg-3675	294	12	-	-	PUNCT
fuelectenerg-3675	294	13	gómez	gómez	NOUN
fuelectenerg-3675	294	14	,	,	PUNCT
fuelectenerg-3675	294	15	j.c	j.c	PROPN
fuelectenerg-3675	294	16	.	.	PROPN
fuelectenerg-3675	294	17	martínez	martínez	PROPN
fuelectenerg-3675	294	18	-	-	PUNCT
fuelectenerg-3675	294	19	garcía	garcía	ADJ
fuelectenerg-3675	294	20	,	,	PUNCT
fuelectenerg-3675	294	21	"	"	PUNCT
fuelectenerg-3675	294	22	quasistatic	quasistatic	ADJ
fuelectenerg-3675	294	23	ac	ac	ADJ
fuelectenerg-3675	294	24	forc	forc	NOUN
fuelectenerg-3675	294	25	measurements	measurement	NOUN
fuelectenerg-3675	294	26	for	for	ADP
fuelectenerg-3675	294	27	soft	soft	ADJ
fuelectenerg-3675	294	28	magnetic	magnetic	ADJ
fuelectenerg-3675	294	29	materials	material	NOUN
fuelectenerg-3675	294	30	and	and	CCONJ
fuelectenerg-3675	294	31	their	their	PRON
fuelectenerg-3675	294	32	differential	differential	ADJ
fuelectenerg-3675	294	33	interpretation	interpretation	NOUN
fuelectenerg-3675	294	34	"	"	PUNCT
fuelectenerg-3675	294	35	,	,	PUNCT
fuelectenerg-3675	294	36	ieee	ieee	NOUN
fuelectenerg-3675	294	37	transactions	transaction	NOUN
fuelectenerg-3675	294	38	on	on	ADP
fuelectenerg-3675	294	39	magnetics	magnetic	NOUN
fuelectenerg-3675	294	40	,	,	PUNCT
fuelectenerg-3675	294	41	vol	vol	NOUN
fuelectenerg-3675	294	42	.	.	PROPN
fuelectenerg-3675	295	1	53	53	NUM
fuelectenerg-3675	295	2	,	,	PUNCT
fuelectenerg-3675	295	3	no	no	INTJ
fuelectenerg-3675	295	4	.	.	NOUN
fuelectenerg-3675	295	5	11	11	NUM
fuelectenerg-3675	295	6	,	,	PUNCT
fuelectenerg-3675	295	7	p.	p.	NOUN
fuelectenerg-3675	295	8	2003606	2003606	NUM
fuelectenerg-3675	295	9	,	,	PUNCT
fuelectenerg-3675	295	10	nov	nov	PROPN
fuelectenerg-3675	295	11	.	.	PROPN
fuelectenerg-3675	295	12	2017	2017	NUM
fuelectenerg-3675	295	13	.	.	PUNCT
fuelectenerg-3675	296	1	[	[	X
fuelectenerg-3675	296	2	5	5	NUM
fuelectenerg-3675	296	3	]	]	X
fuelectenerg-3675	296	4	k.l	k.l	PROPN
fuelectenerg-3675	296	5	.	.	PROPN
fuelectenerg-3675	296	6	kaiser	kaiser	PROPN
fuelectenerg-3675	296	7	,	,	PUNCT
fuelectenerg-3675	296	8	electromagnetic	electromagnetic	ADJ
fuelectenerg-3675	296	9	compatibility	compatibility	NOUN
fuelectenerg-3675	296	10	handbook	handbook	NOUN
fuelectenerg-3675	296	11	,	,	PUNCT
fuelectenerg-3675	296	12	crc	crc	NOUN
fuelectenerg-3675	296	13	press	press	PROPN
fuelectenerg-3675	296	14	,	,	PUNCT
fuelectenerg-3675	296	15	new	new	PROPN
fuelectenerg-3675	296	16	york	york	PROPN
fuelectenerg-3675	296	17	,	,	PUNCT
fuelectenerg-3675	296	18	usa	usa	PROPN
fuelectenerg-3675	296	19	,	,	PUNCT
fuelectenerg-3675	296	20	2004	2004	NUM
fuelectenerg-3675	296	21	.	.	PUNCT
fuelectenerg-3675	297	1	[	[	X
fuelectenerg-3675	297	2	6	6	NUM
fuelectenerg-3675	297	3	]	]	X
fuelectenerg-3675	297	4	iec	iec	PROPN
fuelectenerg-3675	297	5	60404	60404	NUM
fuelectenerg-3675	297	6	-	-	SYM
fuelectenerg-3675	297	7	2	2	NUM
fuelectenerg-3675	297	8	edition	edition	NOUN
fuelectenerg-3675	297	9	3.1	3.1	NUM
fuelectenerg-3675	297	10	,	,	PUNCT
fuelectenerg-3675	297	11	"	"	PUNCT
fuelectenerg-3675	297	12	magnetic	magnetic	ADJ
fuelectenerg-3675	297	13	materials	material	NOUN
fuelectenerg-3675	297	14	–	–	PUNCT
fuelectenerg-3675	297	15	part	part	NOUN
fuelectenerg-3675	297	16	2	2	NUM
fuelectenerg-3675	297	17	:	:	PUNCT
fuelectenerg-3675	297	18	methods	method	NOUN
fuelectenerg-3675	297	19	of	of	ADP
fuelectenerg-3675	297	20	measurement	measurement	NOUN
fuelectenerg-3675	297	21	of	of	ADP
fuelectenerg-3675	297	22	the	the	DET
fuelectenerg-3675	297	23	magnetic	magnetic	ADJ
fuelectenerg-3675	297	24	properties	property	NOUN
fuelectenerg-3675	297	25	of	of	ADP
fuelectenerg-3675	297	26	electrical	electrical	ADJ
fuelectenerg-3675	297	27	steel	steel	NOUN
fuelectenerg-3675	297	28	strip	strip	NOUN
fuelectenerg-3675	297	29	and	and	CCONJ
fuelectenerg-3675	297	30	sheet	sheet	NOUN
fuelectenerg-3675	297	31	by	by	ADP
fuelectenerg-3675	297	32	means	mean	NOUN
fuelectenerg-3675	297	33	of	of	ADP
fuelectenerg-3675	297	34	an	an	DET
fuelectenerg-3675	297	35	epstein	epstein	PROPN
fuelectenerg-3675	297	36	frame	frame	NOUN
fuelectenerg-3675	297	37	"	"	PUNCT
fuelectenerg-3675	297	38	,	,	PUNCT
fuelectenerg-3675	297	39	iec	iec	PROPN
fuelectenerg-3675	297	40	,	,	PUNCT
fuelectenerg-3675	297	41	geneva	geneva	PROPN
fuelectenerg-3675	297	42	,	,	PUNCT
fuelectenerg-3675	297	43	switzerland	switzerland	PROPN
fuelectenerg-3675	297	44	,	,	PUNCT
fuelectenerg-3675	297	45	june	june	PROPN
fuelectenerg-3675	297	46	2008	2008	NUM
fuelectenerg-3675	297	47	.	.	PUNCT
fuelectenerg-3675	298	1	[	[	X
fuelectenerg-3675	298	2	7	7	X
fuelectenerg-3675	298	3	]	]	X
fuelectenerg-3675	298	4	national	national	ADJ
fuelectenerg-3675	298	5	instruments	instrument	NOUN
fuelectenerg-3675	298	6	:	:	PUNCT
fuelectenerg-3675	298	7	“	"	PUNCT
fuelectenerg-3675	298	8	ni	ni	PROPN
fuelectenerg-3675	298	9	6009	6009	NUM
fuelectenerg-3675	298	10	low	low	ADJ
fuelectenerg-3675	298	11	-	-	PUNCT
fuelectenerg-3675	298	12	cost	cost	NOUN
fuelectenerg-3675	298	13	,	,	PUNCT
fuelectenerg-3675	298	14	bus	bus	NOUN
fuelectenerg-3675	298	15	-	-	PUNCT
fuelectenerg-3675	298	16	powered	power	VERB
fuelectenerg-3675	298	17	multifunction	multifunction	NOUN
fuelectenerg-3675	298	18	daq	daq	PROPN
fuelectenerg-3675	298	19	for	for	ADP
fuelectenerg-3675	298	20	usb	usb	PRON
fuelectenerg-3675	298	21	”	"	PUNCT
fuelectenerg-3675	298	22	,	,	PUNCT
fuelectenerg-3675	298	23	austin	austin	PROPN
fuelectenerg-3675	298	24	,	,	PUNCT
fuelectenerg-3675	298	25	usa	usa	PROPN
fuelectenerg-3675	298	26	,	,	PUNCT
fuelectenerg-3675	298	27	2014	2014	NUM
fuelectenerg-3675	298	28	.	.	PUNCT
fuelectenerg-3675	299	1	[	[	X
fuelectenerg-3675	299	2	8	8	X
fuelectenerg-3675	299	3	]	]	PUNCT
fuelectenerg-3675	299	4	s.	s.	PROPN
fuelectenerg-3675	299	5	zurek	zurek	PROPN
fuelectenerg-3675	299	6	,	,	PUNCT
fuelectenerg-3675	299	7	t.	t.	PROPN
fuelectenerg-3675	299	8	kutrowski	kutrowski	PROPN
fuelectenerg-3675	299	9	,	,	PUNCT
fuelectenerg-3675	299	10	a.j	a.j	PROPN
fuelectenerg-3675	299	11	.	.	PROPN
fuelectenerg-3675	299	12	moses	moses	PROPN
fuelectenerg-3675	299	13	,	,	PUNCT
fuelectenerg-3675	299	14	p.	p.	PROPN
fuelectenerg-3675	299	15	anderson	anderson	PROPN
fuelectenerg-3675	299	16	,	,	PUNCT
fuelectenerg-3675	299	17	"	"	PUNCT
fuelectenerg-3675	299	18	measurements	measurement	NOUN
fuelectenerg-3675	299	19	at	at	ADP
fuelectenerg-3675	299	20	very	very	ADV
fuelectenerg-3675	299	21	low	low	ADJ
fuelectenerg-3675	299	22	flux	flux	NOUN
fuelectenerg-3675	299	23	density	density	NOUN
fuelectenerg-3675	299	24	and	and	CCONJ
fuelectenerg-3675	299	25	power	power	NOUN
fuelectenerg-3675	299	26	frequencies	frequency	NOUN
fuelectenerg-3675	299	27	"	"	PUNCT
fuelectenerg-3675	299	28	,	,	PUNCT
fuelectenerg-3675	299	29	journal	journal	NOUN
fuelectenerg-3675	299	30	of	of	ADP
fuelectenerg-3675	299	31	electrical	electrical	ADJ
fuelectenerg-3675	299	32	engineering	engineering	NOUN
fuelectenerg-3675	299	33	,	,	PUNCT
fuelectenerg-3675	299	34	vol	vol	NOUN
fuelectenerg-3675	299	35	.	.	PROPN
fuelectenerg-3675	299	36	59	59	NUM
fuelectenerg-3675	299	37	,	,	PUNCT
fuelectenerg-3675	299	38	no	no	INTJ
fuelectenerg-3675	299	39	.	.	NOUN
fuelectenerg-3675	300	1	7	7	NUM
fuelectenerg-3675	300	2	/	/	SYM
fuelectenerg-3675	300	3	s	s	PROPN
fuelectenerg-3675	300	4	,	,	PUNCT
fuelectenerg-3675	300	5	pp	pp	ADJ
fuelectenerg-3675	300	6	.	.	PUNCT
fuelectenerg-3675	301	1	7	7	NUM
fuelectenerg-3675	301	2	-	-	SYM
fuelectenerg-3675	301	3	10	10	NUM
fuelectenerg-3675	301	4	,	,	PUNCT
fuelectenerg-3675	301	5	2008	2008	NUM
fuelectenerg-3675	301	6	.	.	PUNCT
fuelectenerg-3675	302	1	[	[	X
fuelectenerg-3675	302	2	9	9	NUM
fuelectenerg-3675	302	3	]	]	SYM
fuelectenerg-3675	302	4	ss49e	ss49e	NOUN
fuelectenerg-3675	302	5	linear	linear	PROPN
fuelectenerg-3675	302	6	hall	hall	PROPN
fuelectenerg-3675	302	7	effect	effect	PROPN
fuelectenerg-3675	302	8	sensor	sensor	NOUN
fuelectenerg-3675	302	9	.	.	PUNCT
fuelectenerg-3675	303	1	available	available	ADJ
fuelectenerg-3675	303	2	at	at	ADP
fuelectenerg-3675	303	3	:	:	PUNCT
fuelectenerg-3675	303	4	https://www.addicore.com/ss49e-linear-hall-sensorp/ad316.htm	https://www.addicore.com/ss49e-linear-hall-sensorp/ad316.htm	X
fuelectenerg-3675	303	5	.	.	PUNCT
fuelectenerg-3675	304	1	[	[	X
fuelectenerg-3675	304	2	10	10	NUM
fuelectenerg-3675	304	3	]	]	X
fuelectenerg-3675	304	4	https://www.originlab.com/doc/origin-help/lr-algorithm#adj._r-square	https://www.originlab.com/doc/origin-help/lr-algorithm#adj._r-square	PROPN
fuelectenerg-3675	304	5	.	.	PUNCT
fuelectenerg-3675	305	1	[	[	X
fuelectenerg-3675	305	2	11	11	NUM
fuelectenerg-3675	305	3	]	]	PUNCT
fuelectenerg-3675	305	4	s.	s.	PROPN
fuelectenerg-3675	305	5	zurek	zurek	PROPN
fuelectenerg-3675	305	6	,	,	PUNCT
fuelectenerg-3675	305	7	characterisation	characterisation	NOUN
fuelectenerg-3675	305	8	of	of	ADP
fuelectenerg-3675	305	9	soft	soft	ADJ
fuelectenerg-3675	305	10	magnetic	magnetic	ADJ
fuelectenerg-3675	305	11	materials	material	NOUN
fuelectenerg-3675	305	12	under	under	ADP
fuelectenerg-3675	305	13	rotational	rotational	ADJ
fuelectenerg-3675	305	14	magnetisation	magnetisation	NOUN
fuelectenerg-3675	305	15	,	,	PUNCT
fuelectenerg-3675	305	16	crc	crc	NOUN
fuelectenerg-3675	305	17	press	press	PROPN
fuelectenerg-3675	305	18	,	,	PUNCT
fuelectenerg-3675	305	19	london	london	PROPN
fuelectenerg-3675	305	20	,	,	PUNCT
fuelectenerg-3675	305	21	uk	uk	PROPN
fuelectenerg-3675	305	22	,	,	PUNCT
fuelectenerg-3675	305	23	2018	2018	NUM
fuelectenerg-3675	305	24	.	.	PUNCT
fuelectenerg-3675	306	1	[	[	X
fuelectenerg-3675	306	2	12	12	NUM
fuelectenerg-3675	306	3	]	]	X
fuelectenerg-3675	306	4	jcgm	jcgm	PROPN
fuelectenerg-3675	306	5	100	100	NUM
fuelectenerg-3675	306	6	,	,	PUNCT
fuelectenerg-3675	306	7	evaluation	evaluation	NOUN
fuelectenerg-3675	306	8	of	of	ADP
fuelectenerg-3675	306	9	measurement	measurement	NOUN
fuelectenerg-3675	306	10	data	datum	NOUN
fuelectenerg-3675	306	11	,	,	PUNCT
fuelectenerg-3675	306	12	guide	guide	VERB
fuelectenerg-3675	306	13	to	to	ADP
fuelectenerg-3675	306	14	the	the	DET
fuelectenerg-3675	306	15	expression	expression	NOUN
fuelectenerg-3675	306	16	of	of	ADP
fuelectenerg-3675	306	17	uncertainty	uncertainty	NOUN
fuelectenerg-3675	306	18	in	in	ADP
fuelectenerg-3675	306	19	measurement	measurement	NOUN
fuelectenerg-3675	306	20	,	,	PUNCT
fuelectenerg-3675	306	21	joint	joint	ADJ
fuelectenerg-3675	306	22	committee	committee	NOUN
fuelectenerg-3675	306	23	for	for	ADP
fuelectenerg-3675	306	24	guides	guide	NOUN
fuelectenerg-3675	306	25	in	in	ADP
fuelectenerg-3675	306	26	metrology	metrology	NOUN
fuelectenerg-3675	306	27	,	,	PUNCT
fuelectenerg-3675	306	28	2008	2008	NUM
fuelectenerg-3675	306	29	.	.	PUNCT
fuelectenerg-3675	307	1	[	[	X
fuelectenerg-3675	307	2	13	13	NUM
fuelectenerg-3675	307	3	]	]	X
fuelectenerg-3675	307	4	national	national	ADJ
fuelectenerg-3675	307	5	instruments	instrument	NOUN
fuelectenerg-3675	307	6	,	,	PUNCT
fuelectenerg-3675	307	7	ni	ni	PROPN
fuelectenerg-3675	307	8	9205	9205	NUM
fuelectenerg-3675	307	9	,	,	PUNCT
fuelectenerg-3675	307	10	datasheet	datasheet	PROPN
fuelectenerg-3675	307	11	,	,	PUNCT
fuelectenerg-3675	307	12	2015	2015	NUM
fuelectenerg-3675	307	13	.	.	PUNCT
