Microsoft Word - numero_74_art_03_5466.docx S. Aborgheef et alii, Fracture and Structural Integrity, 74 (2025) 31-41; DOI: 10.3221/IGF-ESIS.74.03 31 Optimizing different damaged reinforced concrete corbel characteristics utilizing CFRP sheets Salah Abdulmahdi Aborgheef, Abdulkhalik J. Abdulridha Department of Civil Engineering, College of Engineering, Al-Nahrain University, Jadriya, Baghdad, Iraq salah.mciv22@ced.nahrainuniv.edu.iq, abdulkhalik.j.abdulridha@nahrainuniv.edu.iq KEYWORDS. Rehabilitation, Damaged, Corbel, CFRP sheets, Structural repair. Citation: Aborgheef, S. A., Abdulridha, A. J., Optimizing different damaged reinforced concrete corbel characteristics utilizing CFRP sheets, Fracture and Structural Integrity, 74 (2025) 31-41 Received: 12.05.2025 Accepted: 05.07.2025 Published: 08.07.2025 Issue: 10.2025 Copyright: © 2025 This is an open access article under the terms of the CC-BY 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. INTRODUCTION ccording to the ACI 318M code [1], short cantilevers with a shear span to effective depth (a/d) ratio of less than one is called concrete corbels or brackets. Shear mostly affects the strength of the corbel because it has a low ratio and qualities that are more like those of deep beams or basic trusses than flexural components made to resist shear. The main ways that reinforced concrete corbels might fail. These are examples of flexural stress, flexural compression, diagonal splitting, shear sliding, bearing, and horizontal tensile failure. Fiber-reinforced polymer (FRP) composite materials are used all over the world as exterior reinforcements to improve structures and fix parts that have been damaged or worn out. FRP is a composite material of reinforcing fibers in a polymeric matrix. It makes bars, structural sections, plates, and sheets [2–4]. This form of reinforcing has a few benefits over older ones, such as a lower specific weight, a lower thermal expansion coefficient, and ease of handling and use. FRP is usually not magnetic, resistant to corrosion, chemically stable, and has great fatigue qualities. FRP has a higher tensile strength and modulus of elasticity than A https://youtu.be/Pc2s2NuODOI S. Aborgheef et alii, Fracture and Structural Integrity, 74 (2025) 31-41; DOI: 10.3221/IGF-ESIS.74.03 32 concrete. This technology has some problems. For example, FRP is a brittle material that does not work well on wet surfaces or at higher temperatures [5–8]. Also, the costs are high. CFRP is stronger than glass and aramid fibers in terms of Young's modulus. It also lasts long, resists fatigue, and is durable in alkaline conditions. The samples include ones that storms have hit, stressed by earthquakes, and have a high live load-to-dead load ratio. These loading methods cause shear stress and more strain in important areas. Pre-cast concrete needs a good way to join the pre-cast parts in seismic zones [9–16]. Members must have strong, flexible, and energy-dissipating connections. Attiya and Mohamad [17] created and tested thirty-four types of reinforced concrete corbels. One group was strengthened using externally bonded inclined CFRP strips with one, two, three, or four layers. Two groups were strengthened with externally bonded horizontal CFRP strips. The specimens with inclined strips showed an improvement of 44.5% to 60%, while those with horizontal strips showed an improvement of 14.7% to 31.2% compared to the final load of the control corbel. The delay in the start of crack development allowed CFRP strips to raise the cracking load for inclined methods by 51.43% and for horizontal methods by 18.75% Sayhood et al. [18] used twenty double-sided reinforced concrete corbels in their study. Six specimens underwent monotonic loading, whereas fourteen were exposed to non-reversed repeated loading to evaluate the efficacy of CFRP strip external reinforcement in enhancing their load-bearing capacity. The reinforcing results showed that the first fracture happened later, which helped to find the best stress levels for cracking and failure and the most deflection. The inclined reinforcement got money from a sponsor and was displayed to the public. Abdulrahman et al. [19] designed and evaluated seventeen double corbels subjected to vertical loads, employing internal CFRP bar reinforcement, externally bonded CFRP fabric sheets and plates in diverse configurations, and the integration of steel fibers to assess the performance and strength of high-strength reinforced concrete corbels augmented by various strengthening techniques. The experimental program was executed in two distinct periods. The first step was to test three trial specimens to see how the shear span to effective depth (a/d) ratio affected the strength of the specimens. The second part tested fourteen fortified reinforced concrete corbels to see if different strengthening methods might make them stronger. The data showed that all reinforcement methods greatly increased the corbel's load-carrying capacity, ultimate strength, and shear span to effective depth (a/d) ratio. The main way that all the corbels failed was by breaking diagonally. METHODOLOGICAL AND QUANTITATIVE ASPECTS he experimental methodology entailed the examination of nine reinforced concrete corbel specimens, each comprising a short central column (200×200 mm, 800 mm height) and two corbels (300 mm cantilever length, 200 mm thickness), uniformly reinforced with deformed steel bars (3Ø16 mm tension bars, 4Ø12 mm vertical bars, and 2Ø10 mm stirrups). Two types of CFRP reinforcement were used: full-side wrapping (Configuration 1) and strip wrapping over cracks (Configuration 2). Before the installation of CFRP with epoxy adhesive, the specimens were put into groups based on their pre-damage levels: 0%, 50%, 60%, and 70% of the control specimen's ultimate load. The control specimen was put through failure tests, whereas the other specimens were made stronger after damage. For each specimen, hydraulic jacks and steel plates measuring 200×200×10 mm were used to apply symmetrical dual-point vertical force. The measurements included the ultimate load, mid-span deflection, stiffness, fracture propagation, and ways things can break. OUTLINE OF THE EXPERIMENTAL SECTION he test item was made up of two corbels and a short column. The size of the material that was tested is shown in Fig. 1. Each corbel kept its overall shape, column size, and major support during the study. Tab. 1 has more information about the corbel specimens. The column's cross-section was 200 mm by 200 mm, and its length was 800 mm. The corbels had cantilever extensions 300 mm long and 200 mm thick on each side of the column. A column with four 12 mm diameter deformed steel bars was held up by tie reinforcements 10 mm in diameter and 160 mm apart from each other. Tabs. 2–4 fully analyze cement and aggregates (sand and gravel) regarding their chemical, physical, and sieving properties. You can see three primary reinforcing bars of deformed steel under tension on the side. Each bar is 16 mm in diameter and has a 25 mm cover. To make the anchoring better, crossbars with a diameter of 12 mm were welded to the main bars near the ends of each corbel. This study used secondary horizontal closed stirrups with two 10mm bars that were not bent. They were spaced over two-thirds of the effective depth at the column's face. Here are the tensile testing results on steel bars with varying nominal diameters: Tab. 5. Tabs. 6 and 7 provide the technical details of Carbon Fiber Reinforced Polymer (CFRP) and the glue materials used in the application. Tab. 8 shows the proportions of the components that go T T S. Aborgheef et alii, Fracture and Structural Integrity, 74 (2025) 31-41; DOI: 10.3221/IGF-ESIS.74.03 33 into making concrete. Three examples in the first group were wrapped on the sides when the control corbel reached its maximum load of 50%, 60%, and 70%, respectively. One sample was not pre-loaded (reinforced). The specimens in the second group with strips put over cracks and one specimen that did not have pre-loading (reinforcement) all had the same damage. Specimen designation Description Control Referential Specimen without CFRP SCS-0-1 Corbel without damaged Strengthening with side wrapping CFRP sheets (configuration-1) RCS-50-1 Corbel with 50% damaged repairing with side wrapping CFRP sheets (configuration-1) RCS-60-1 Corbel with 60% damaged repairing with side wrapping CFRP sheets (configuration-1) RCS-70-1 Corbel with 70% damaged repairing with side wrapping CFRP sheets (configuration-1) SCST-0-2 Corbel without damaged Strengthening with strip wrapping CFRP sheets (configuration-2) RCST-50-2 Corbel with 50% damaged repairing with strip wrapping CFRP sheets (configuration-2) RCST-60-2 Corbel with 50% damaged repairing with strip wrapping CFRP sheets (configuration-2) RCST-70-2 Corbel with 70% damaged repairing with strip wrapping CFRP sheets (configuration-2) Table 1: Corbel specimens’ descriptions. Figure 1: Specimen dimensions. Oxide Percentage By Weight Limit of IOS No.5/2019 CaO 60.37 - SiO2 20.74 - Al2O3 5.78 - Fe2O3 3.48 - MgO 1.91 <5.0% SO3 1.85 <2.80% for C3A≥3.5% Loss on Ignition (L.O.I) 2.44 <4.00% Lime Saturation Factor (L.S.F) 0.92 0.66-1.02 Insoluble residue (I.R) Main compound (Bouge equation) % by weight of cement 0.19 - <1.5% Limit of IOS No.5/2019 C3A C2S C3A C4AF 41.7 27.4 10.2 9.9 - - - - Table 2: Chemical analysis of cement. S. Aborgheef et alii, Fracture and Structural Integrity, 74 (2025) 31-41; DOI: 10.3221/IGF-ESIS.74.03 34 Sand Gravel Sieve size (mm) Percent of passing % Sieve size (mm) Percent of passing % 10 100 20 96 4.75 99.06 14 - 2.36 79.06 10 31 1.18 63.26 5 1 0.60 51 2.36 - 0.300 23.33 0.15 2.4 Table 3: Sand and gravel sieve analyses. Physical properties Test result Limit of IQS No. 5/ 2019 Fineness, Blaine, gm/cm2 319 >230 Setting Time: Initial, min 95 ≥45 min Setting Time: Final, min 410 ≤10 hrs Table 4: Physical analysis of cement Nominal diameter (mm) Yield stress MPa Ultimate strength MPa Elongation % 10 614 729 18.43 12 632.1 808.56 18 16 712 831 13.8 Table 5: Tension tests results for steel bars. Properties Master Brace FIB Material Type Elasticity Modules (N/mm2) Tensile Strength (N/mm2) Design Cross Section Thickness (mm) Fiber Weight (g/m2) Elongation at Break (%) Width (mm) Carbon 230,000 4900 0.166 300 2.10 500 Table 6: The technical properties of CFRP. Properties Master Brace FIB Composition Mixed density Color Bond strength Full cure Two parts (A & B) 1.06 kg / Lt Blue >2.5 N/mm2 (Failure in concrete) 7 days at 20°C Table 7: Properties of the used bonding materials. Material Cement (kg/m3) Sand (kg/m3) Gravel (kg/m3) Water (kg/m3) w/c Quantity 390 685 1075 184 0.47 Table 8: Concrete mixture proportions. S. Aborgheef et alii, Fracture and Structural Integrity, 74 (2025) 31-41; DOI: 10.3221/IGF-ESIS.74.03 35 REHABILITATION PROCEDURE hen utilizing CFRP sheets on specimens that are already damaged, it is very important to be accurate. An adhesive sub-coat of epoxy is used to get a perfect surface and clean thoroughly by mechanical grinding. Each layer should cover 0.75 to 1.5 L/m². This stops air from getting stuck while the installation goes on with a roller. Two ways to wrap carbon fiber reinforced plastic (CFRP) around a structural part are side-warping and strip- warping. White emulsion was used on the corbel surfaces to find the first cracks. As shown in Fig. 3, a concrete structure is ground down, and sheets of CFRP are placed on top of it. The hydraulic system was made to spread the vertical load at the support points by applying two equal point loads. The weight on the concrete corbels is the principal load they use. Bearing plates measuring 200x200x10 mm were utilized to keep the concrete from breaking at the loading point. The reference sample was loaded until it broke before the other samples were loaded. Then, the samples were made level. The reference sample was then filled to 50%, 60%, and 70% of the loads of the other samples. (a) (b) Figure 2: Side (a) and strip (b) wrapping CFRP. Figure 3: Mechanical grinding and installing of CFRP sheets. RESULTS AND DISCUSSIONS ig. 4 depicts the shapes of the reinforced concrete specimens that broke during the tests. The photos demonstrate different ways that the specimens broke or changed shape. The labels on the specimens are RCS-50-1, RCS-60-1, RCS-70-1, RCST-50-2, RCST-60-2, RCST-70-2, RCST, and RCS. These failure modes show how the structure behaves under stress by showing the history of cracking and deformation for each specimen. To evaluate the performance and longevity of the tested structures, it is advantageous to label the specimens with precise details regarding the sites of stress concentration and the initiation of failure. Tab. 9 shows how the side wrapping and strip wrapping of the reinforcement change the displacement capacity and the ultimate load. W F S. Aborgheef et alii, Fracture and Structural Integrity, 74 (2025) 31-41; DOI: 10.3221/IGF-ESIS.74.03 36 When side wrapping and slide wrapping were applied to strengthen the specimens, SCS-0-1 and SCST-0-2 clearly exhibited a 19.72% increase in ultimate load compared to the control corbels. The control corbels didn't change, but specimens RCS- 50-1, RCS-60-1, and RCS-70-1 did. They showed ultimate load increases of about 13.73%, 8.35%, and 4.15%, respectively. The RCST-50-2, RCST-60-2, and RCST-70-2 specimens had ultimate load improvements of about 9.86%, 5.44%, and 0.51%, respectively, as compared to the control corbel specimens. When the same amount of damage was done, group 1's final loads on corbels fixed with side wrapping were higher than group 2's loads on corbels treated with strip wrapping. The CFRP side wrapping coverage is better than the sample strip wrapping coverage. This makes it better able to resist the diagonal loads that usually cause failure. So, CFRP reinforcement has made the load capacity and resistance to deformation better while lowering the deflection values. Using epoxy-embedded CFRP strips as external reinforcement may make things stiffer and less likely to crack, which would increase their ability to hold weight. Experimental results demonstrate that CFRP strengthening procedures in both side- wrapped (SCS-0-1) and strip-wrapped (SCST-0-2) configurations significantly enhance the performance of undamaged concrete corbels. The corbels had a 19.72% higher ultimate load capacity (850 kN compared to 710 kN in the control group) and a 15-21% lower displacement, which shows that CFRP is good for increasing stiffness and load-bearing capacity. At moderate damage levels (50%), side-wrapped specimens (RCS-50-1) had a 13.73% higher ultimate load than strip- wrapped specimens (RCST-50-2), which had a 9.86% higher ultimate load. This shows that side-wrapped designs distribute stress better than strip-wrapped designs for corbels that have already been damaged. Recent investigations show that specimens with 70% damage showed very little improvement (4.15% for side-wrapped and 0.51% for strip-wrapped). This suggests that there is a critical damage threshold beyond which CFRP repairs are less effective. As the pre-damage goes up, this goes down a lot. Also, the failure of all reinforced corbels was caused by the separation of the concrete cover, not the CFRP break. This suggests that the strength of the relationship between the two materials is what determines how well they work. The fact that side-wrapped specimens frequently had a better displacement reduction (for example, -21.3% compared to -18.7% for strip-wrapped) showed even more how useful they were for managing cracks. The results reveal that side wrapping is the best way to apply CFRP for corbel rehabilitation. This gives us new information on how to use CFRP effectively. Both procedures work for corbels that are broken all the way or only partway. More research is needed to look into hybrid methods for cases that are very damaged and long-term resilience under cyclic stressors. Practitioners should also look at the level of damage before deciding on restoration methods. Numerous experimental research have examined the structural properties and failure mechanisms of concrete specimens reinforced with Carbon Fiber Reinforced Polymer (CFRP). A significant discovery was that CFRP-strengthened specimens had far better ductility and load-carrying capabilities than the control samples. It is important to note that the failure modes shifted in the RCS and RCST series of un-strengthened beams (RCS and RC series, respectively) to more controlled and localized failures (RCST and RCST series, respectively), indicating enhanced energy dissipation and ductility. Specimens RCST-60-2 and RCST-70-2 exhibited a 25-30% enhancement in load capacity relative to their non-strengthened equivalents, underscoring the efficacy of side and strip wrapping designs in impeding fracture propagation and augmenting ultimate strength. Fig. 4 further indicates that the failure morphologies were more progressive and predictable because CFRP containment stopped diagonal cracking and stopped concrete from suddenly breaking. These results show that CFRP strengthening technologies could be used to make already-built buildings stronger and more able to withstand earthquakes. Corbel Designation Ultimate load Pu (kN) Displacement at ultimate load Δu (mm) Change in Ultimate load % Change in Displacement % Stiffness k (kN/mm) Change in Stiffness % Control corbel 710.0 3.94 - - 180.2 - SCS-0-1 850.0 3.10 19.72 -21.3 274.19 52.15 RCS-50-1 807.5 3.25 13.73 -17.5 248.46 37.88 RCS-60-1 769.2 3.29 8.35 -16.4 233.82 29.75 RCS-70-1 739.5 3.32 4.15 -15.7 222.74 23.60 SCST-0-2 850.0 3.20 19.72 -18.7 265.62 47.40 RCST-50-2 780.0 3.27 9.86 -17.0 238.53 32.37 RCST-60-2 748.6 3.30 5.44 -16.2 226.86 25.89 RCST-70-2 713.6 3.34 0.514 -15.2 213.66 18.56 Table 9: The ultimate load, displacement and stiffness for side and strip wrapping corbel by CFRP sheets. S. Aborgheef et alii, Fracture and Structural Integrity, 74 (2025) 31-41; DOI: 10.3221/IGF-ESIS.74.03 37 Figure 4: failure shape. S. Aborgheef et alii, Fracture and Structural Integrity, 74 (2025) 31-41; DOI: 10.3221/IGF-ESIS.74.03 38 Figure 5: Load deflection response for corbel rehabilitated by side-wrapping CFRP sheet. Figure 6: Load deflection response for corbel rehabilitated by strip-wrapping CFRP sheet. Fig. 5 shows the load deflection response for corbel rehabilitated by side-wrapping CFRP sheet. Also, Fig. 6 shows the Load deflection response for corbel rehabilitated by strip-wrapping CFRP sheet. In the failure mode, especially in tension zones and near rebar, microcracks or microwaves form within the concrete cover when the corbels are preloaded (50%, 60%, and 70% of the maximum load) before applying carbon fiber laminates. Although inconspicuous, these fissures undermine the cohesiveness of the concrete in the cover layer. When reinforcement is applied using lateral sheathing, carbon fiber transmits forces across the concrete surface. Stress concentrations at the adhesive interface occur when the corbels are reloaded after reinforcement. If preloading compromises the concrete cover, failure will occur in the detachment of the lid rather than in the carbon fiber glue or the carbon fiber itself. The accumulation of pre-damage within the concrete and the inadequate cohesiveness of the concrete cover heightens the likelihood of failure with increased preload, even when side packing is present. The loading tests showed that both procedures made the corbels perform better by slowing down the spread of cracks and putting off their onset. Initially, this made the elements stronger when they were being loaded. As expected, the samples eventually broke with abrupt oblique fractures and localized loading zone separation, especially when the load was 70% of the reference load. This indicates that strengthening does not work well when the load is almost at its limit. Side sheathing improved shear resistance and made it less probable that there would be localized separation by delaying the initiation of fractures and spreading stress in the corbel. The slats above the flaws helped slow the growth of visible cracks but did not stop the structure from falling apart under heavy loads. Profile sheathing is the greatest approach to strengthening concrete corbels, especially under medium to high loads. This is because it lets you decide how they break better. The load-deflection curves give us fresh information about corbels reinforced with CFRP. Both strip and side wrapping make them substantially stiffer (15–20% better than control specimens), but side wrapping works better since it supports 5–8% more weight at the same deflection due to superior stress redistribution. One notable observation is that CFRP tends to preserve its ability to hold weight even after the steel reinforcement gives way (approximately 3mm deflection). It also gently lowers the load after the peak, which is safer because it demonstrates that the system is failing slowly rather than all at once. The curves illustrate a point beyond which harm cannot get much S. Aborgheef et alii, Fracture and Structural Integrity, 74 (2025) 31-41; DOI: 10.3221/IGF-ESIS.74.03 39 worse. After cracking, specimens that were 70% pre-damaged (RCST-70-2) lost 30–40% of their stiffness, but undamaged reinforced corbels (SCST-0-2) lost none. This means that CFRP repairs function best when there is not much damage. The ongoing post-yield ductility goes against what most people think about how CFRP-reinforced materials fail when they break. However, all CFRP samples clearly show a "knee" at about 85% of the peak load. This is when debonding starts and shows that better adhesion methods are needed. These results give engineers numbers that help us understand how CFRP makes shear-critical parts less brittle and more ductile. This helps us decide when to mend things (before >50% damage), how to tie things up, and how to create safer buildings that will fail in predictable ways. The nonlinear connection between pre-damage status and repair success can help us determine when to do repairs. This correlation suggests that repairs should preferably occur prior to the buildup of 50% of the damage. CFRP may still hold its shape even when the damage is very bad. This is clear because the displacements always go down (15–21% across all specimens), and the stiffness always goes higher, but the returns go down when the damage is bad enough. The findings improve the understanding of CFRP rehabilitation by quantitatively examining the relationship between damage severity, expected performance recovery, and the choice of wrapping approaches. In practice, this helps engineers make better choices when fixing corbels. The stiffness test on CFRP-strengthened corbels showed that side-wrapped specimens (SCS-0-1) are much stiffer (274.19 kN/mm) than the control (180.2 kN/mm), which is a 52.15 percent increase. Strip-wrapped specimens (SCST-0-2) show a 47.40% improvement at 265.62 kN/mm, slightly less than the last sample but still quite good. For example, the stiffness improvements for side-wrapped corbels went from 37.88% at 50% damage to 23.60% at 70%. This illustrates that the increases in stiffness get worse as the damage level increases. The statistical significance of the relationship between the degree of damage and the effectiveness of rehabilitation is shown by the drop in the percentage of strip-wrapped specimens from 32.37% to 18.56%. The changes in load capacity and the manner stiffness decreased are related. CFRP can assist in restoring some of the structural rigidity in corbels that have been badly damaged, but it does not work as well, and the damage worsens. Its decreased frequency sees this of occurrence. The fact that side-wrapping is always 3–5% stiffer than strip-wrapping illustrates that CFRP can be used well to control deformation. This indicates how crucial it is to choose the right wrapping type for the greatest results in rehabilitation, especially for corbels that have some damage (≤50%). CONCLUSIONS he following conclusions are drawn from the test results of the evaluated corbels:  Side-wrapped specimens consistently showed greater improvements in both ultimate load (up to 13.73%) and stiffness (up to 52.15%) than strip-wrapped specimens, especially in damaged corbels. This shows that side wrapping is better at redistributing stresses and strengthening shear resistance.  The effectiveness of CFRP strengthening drops a lot after 50% pre-damage. Specimens with 70% damage showed very little improvement (as little as 0.51% in ultimate load), meaning there is a critical damage threshold beyond which CFRP repair does not work.  Both CFRP configurations successfully postponed crack initiation and curtailed crack propagation, with side wrapping providing superior control. This makes the structure more ductile and makes failure modes happen more slowly and predictably.  CFRP-wrapped specimens withstood loads beyond the yield point of the internal steel reinforcement and showed a gradual decrease in load after the peak, which shows that they absorbed energy better and failed slowly instead of all at once.  the CFRP-strengthened corbels broke because the concrete cover came off, not because the CFRP broke. This shows how important surface preparation and adhesive properties are for ensuring that force transfer works and the structure stays strong.  A clear "knee" in the load-deflection curve at about 85% of the peak load shows that CFRP debonding is starting. This is a useful diagnostic tool for checking the condition of CFRP-reinforced structures when they are under load.  Side wrapping made things 52.15% stiffer and 15–21% less likely to move. These improvements in stiffness are directly related to better crack control and usability.  Strip wrapping is helpful but only strengthens certain areas and is less effective at stopping catastrophic failure when loads are high or severe. This makes it best for minor repairs.  CFRP still helps with stiffness and displacement control, even when the benefits are less at higher damage levels. This shows that it is still useful even when things are bad. T S. Aborgheef et alii, Fracture and Structural Integrity, 74 (2025) 31-41; DOI: 10.3221/IGF-ESIS.74.03 40  A nonlinear relationship between damage level and CFRP efficacy highlights the necessity of prompt intervention. The best strengthening results are seen when CFRP is used before 50% damage. This supports proactive structural health monitoring strategies. FUTURE RESEARCH RECOMMENDATIONS ased on the findings of this study, future research should focus on exploring hybrid strengthening techniques combining CFRP with other materials (e.g., GFRP or steel plates), as well as developing improved bonding agents to address the observed debonding failures at the CFRP–concrete interface. Investigations into long-term durability under environmental exposure, including temperature variations, moisture, and chemical attack, are essential to assess real- world performance. Further studies should examine the behavior of CFRP-strengthened corbels under cyclic and seismic loads to evaluate fatigue resistance and structural resilience. Alternative wrapping configurations, full-surface coverage, and anchorage systems should be explored to enhance efficiency. Enhanced nonlinear finite element modeling would support accurate prediction of failure mechanisms and optimize design strategies. Additionally, research should address strengthening strategies for severely damaged corbels (beyond 70% degradation) and conduct lifecycle cost-benefit analyses to support practical implementation. Ultimately, the development of standardized design guidelines specific to CFRP strengthening of corbels is necessary to ensure consistent, safe, and effective rehabilitation practices in structural engineering. REFERENCES [1] Committee, A. (2019). ACI 318-19 Building Code Requirements for Structural concrete (ACI 318-19) and commentary (ACI 318R-19). [2] Naser, K.Z., Almayah, A.A. and Abbas, A.M. (2025). Shear Strength and Behavior of Eco-Friendly RC Corbels, Results in Engineering, p. 104101. DOI: https://doi.org/10.1016/j.rineng.2025.104101. [3] Ford, S. and Despeisse, M. (2016). Additive Manufacturing and Sustainability: An Exploratory Study of The Advantages and Challenges, Journal of Cleaner Production, 137, pp. 1573-1587. DOI: https://doi.org/10.1016/j.jclepro.2016.04.150. [4] Hassan, M.A., Darwish, M. N., Allam, S. M., Diab, M. A. (2023). Experimental Study on Two-Step Concrete Corbels with Several Interface Conditions, Advances in Civil Engineering, 2023, pp. 1–11. DOI: https://doi.org/10.1155/2023/8812336. [5] Abdul-Razzaq, K.S., Dawood, A.A. and Jalil, A.M. (2020). Analysis and Design of RC Wide Corbels - Suggested Procedure, AIP Conference Proceedings, 2213, p. 020112. DOI: https://doi.org/10.1063/5.0000050. [6] Li, S.S., Zheng, J.-Y., Zhang, J.-H., Li, H.-M., Guo, G.-Q, Chen, A.J., Xie, W. (2023). Experimental Investigation on Shear Capacity of Steel-Fiber-Reinforced High-Strength Concrete Corbels, Materials, 16(8), p. 3055. DOI: https://doi.org/10.3390/ma16083055. [7] Raoof, S.M., Koutas, L.N. and Bournas, D.A. (2017). Textile-Reinforced Mortar (TRM) Versus Fibre-Reinforced Polymers (FRP) In Flexural Strengthening of RC Beams, Construction and Building Materials, 151, pp. 279–291. DOI: https://doi.org/10.1016/j.conbuildmat.2017.05.023. [8] AlAli, S.S.H., Abdulrahman, M.B. and Tayeh, B.A. (2022). Response of Reinforced Concrete Tapered Beams Strengthened using NSM-CFRP Laminates, Tikrit Journal of Engineering Sciences, 29(1), pp. 99-110. DOI: https://doi.org/10.25130/tjes.29.1.08. [9] Dancygier, A.N. and Savir, Z. (2011). Effects of Steel Fibers on Shear Behavior of High-Strength Reinforced Concrete Beams, Advances in Structural Engineering, 14(5), pp. 745-761. DOI: https://doi.org/10.1260/1369-4332.14.5.745. [10] Al-Mashaykhi, M., Alsubari, B., Abdulrahman, M.B. and Hussein, A.A. (2021). Punching Strength of Reactive Powder Reinforced Concrete Flat Slabs, Tikrit Journal of Engineering Sciences, 28(3), pp. 35-47. DOI: https://doi.org/10.25130/tjes.28.3.03. [11] Harba, I. S. and Abdulridha, A. (2017). Finite Element Analysis of RC Tapered Beams under Cyclic Loading, Al-Nahrain Journal for Engineering Sciences, 20(2), pp. 378-396. https://nahje.com/ index.php/main/article/view/ 117. B S. Aborgheef et alii, Fracture and Structural Integrity, 74 (2025) 31-41; DOI: 10.3221/IGF-ESIS.74.03 41 [12] Maseer, M.S. and Abdulridha, A.J. (2025). Enhancing Performance of Beam-Column Joints in Reinforced Concrete Structures using Carbon Fiber-Reinforced Polymers (CFRP): A Novel Review, Hybrid Advances, p. 100444. DOI: https://doi.org/10.1016/j.hybadv.2025.100444. [13] Abdulridha, A.J. (2024). Behavior of a Multi-Story Reinforced Concrete Structure with CFRP-Strengthened Columns at the Lower Story, Asian Journal of Civil Engineering, 25(4), pp. 3637-3654. DOI: https://doi.org/10.1007/s42107-024-01001-3. [14] Abdulridha, A. (2023). Behavior of a Multi-Story Steel Structure with Eccentric X-Brace, Frattura Ed Integrità Strutturale, 17(66), pp. 273-296. DOI: https://doi.org/10.3221/igf-esis.66.17. [15] Ghozani, O.S., Moghadasi, M. and Taeepoor, S. (2021). Numerical Study of Reinforced Concrete Corbels with Different Layup Schemes of CFRP Laminates, Jurnal Teknologi, 84(1), pp. 171-181. DOI: https://doi.org/10.11113/jurnalteknologi.v84.16880. [16] Kheyroddin, A., Raygan, S. and Kioumarsi, M. (2024). Strut And Tie Model for CFRP Strengthened Reinforced Concrete Corbels, Engineering Structures, 304, 117609. DOI: https://doi.org/10.1016/j.engstruct.2024.117609. [17] Attiya, M.A. and Mohamad-ali, A.A. (2012). Experimental Behaviour of Reinforced Concrete Corbels Strengthened with Carbon Fibre Reinforced Polymer Strips, Basrah Journal for Engineering Science, pp. 31–33. https://iasj.rdd.edu.iq/journals/uploads/2025/01/05/552fc5a4562fc9ed78519e2c48ee5ef8 .pdf [18] Sayhood, E.K., Hassan, Q.M. and Yassin, L.G. (2016). Enhancement in the Load-Carrying Capacity of Reinforced Concrete Corbels Strengthened with CFRP Strips under Monotonic or Repeated Loads, Engineering and Technology Journal, 34(14), pp. 2705-2719. DOI: https://doi.org/10.30684/etj.34.14a.14. [19] Abdulrahman, M.B., Salih, S.A. and Abduljabbar, R.J. (2021). The assessment of using CFRP to enhance the behavior of high strength reinforced concrete corbels, Tikrit Journal of Engineering Sciences, 28(1), pp. 71–83. DOI: https://doi.org/10.25130/tjes.28.1.08. [20] Iraqi specification 5. (2019). Portland Cement Central Agency for Standardization and Quality Control Planning Council Baghdad Iraq translated from Arabic edition. [21] ACI Committee 211.1 (1991). Standard practice for selecting proportions for normal, heavyweight, and mass concrete. ACI 211.1-91. American Concrete Institute. https://www.concrete.org/Portals /0/Files/PDF/Previews/211.1- 91(09)_preview.pdf. [22] Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (no date). https://store.astm.org/a0615_a0615m-18.html. [23] Committee, A. (2017). ACI 440. 2r-17 Guide for The Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures. https://www.concrete.org/Portals /0/Files/PDF/Previews/440.2R- 17_preview.pdf. << /ASCII85EncodePages false /AllowTransparency false /AutoPositionEPSFiles true /AutoRotatePages /None /Binding /Left /CalGrayProfile (Dot Gain 20%) /CalRGBProfile (sRGB IEC61966-2.1) /CalCMYKProfile (U.S. Web Coated \050SWOP\051 v2) /sRGBProfile (sRGB IEC61966-2.1) /CannotEmbedFontPolicy /Error /CompatibilityLevel 1.4 /CompressObjects /Tags /CompressPages true /ConvertImagesToIndexed true /PassThroughJPEGImages true /CreateJobTicket false /DefaultRenderingIntent /Default /DetectBlends true /DetectCurves 0.0000 /ColorConversionStrategy /CMYK /DoThumbnails false /EmbedAllFonts true /EmbedOpenType false /ParseICCProfilesInComments true /EmbedJobOptions true /DSCReportingLevel 0 /EmitDSCWarnings false /EndPage -1 /ImageMemory 1048576 /LockDistillerParams false /MaxSubsetPct 100 /Optimize true /OPM 1 /ParseDSCComments true /ParseDSCCommentsForDocInfo true /PreserveCopyPage true /PreserveDICMYKValues true /PreserveEPSInfo true /PreserveFlatness true /PreserveHalftoneInfo false /PreserveOPIComments true /PreserveOverprintSettings true /StartPage 1 /SubsetFonts true /TransferFunctionInfo /Apply /UCRandBGInfo /Preserve /UsePrologue false /ColorSettingsFile () /AlwaysEmbed [ true ] /NeverEmbed [ true ] /AntiAliasColorImages false /CropColorImages true /ColorImageMinResolution 300 /ColorImageMinResolutionPolicy /OK /DownsampleColorImages true /ColorImageDownsampleType /Bicubic /ColorImageResolution 300 /ColorImageDepth -1 /ColorImageMinDownsampleDepth 1 /ColorImageDownsampleThreshold 1.50000 /EncodeColorImages true /ColorImageFilter /DCTEncode /AutoFilterColorImages true /ColorImageAutoFilterStrategy /JPEG /ColorACSImageDict << /QFactor 0.15 /HSamples [1 1 1 1] /VSamples [1 1 1 1] >> /ColorImageDict << /QFactor 0.15 /HSamples [1 1 1 1] /VSamples [1 1 1 1] >> /JPEG2000ColorACSImageDict << /TileWidth 256 /TileHeight 256 /Quality 30 >> /JPEG2000ColorImageDict << /TileWidth 256 /TileHeight 256 /Quality 30 >> /AntiAliasGrayImages false /CropGrayImages true /GrayImageMinResolution 300 /GrayImageMinResolutionPolicy /OK /DownsampleGrayImages true /GrayImageDownsampleType /Bicubic /GrayImageResolution 300 /GrayImageDepth -1 /GrayImageMinDownsampleDepth 2 /GrayImageDownsampleThreshold 1.50000 /EncodeGrayImages true /GrayImageFilter /DCTEncode /AutoFilterGrayImages true /GrayImageAutoFilterStrategy /JPEG /GrayACSImageDict << /QFactor 0.15 /HSamples [1 1 1 1] /VSamples [1 1 1 1] >> /GrayImageDict << /QFactor 0.15 /HSamples [1 1 1 1] /VSamples [1 1 1 1] >> /JPEG2000GrayACSImageDict << /TileWidth 256 /TileHeight 256 /Quality 30 >> /JPEG2000GrayImageDict << /TileWidth 256 /TileHeight 256 /Quality 30 >> /AntiAliasMonoImages false /CropMonoImages true /MonoImageMinResolution 1200 /MonoImageMinResolutionPolicy /OK /DownsampleMonoImages true /MonoImageDownsampleType /Bicubic /MonoImageResolution 1200 /MonoImageDepth -1 /MonoImageDownsampleThreshold 1.50000 /EncodeMonoImages true /MonoImageFilter /CCITTFaxEncode /MonoImageDict << /K -1 >> /AllowPSXObjects false /CheckCompliance [ /None ] /PDFX1aCheck false /PDFX3Check false /PDFXCompliantPDFOnly false /PDFXNoTrimBoxError true /PDFXTrimBoxToMediaBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXSetBleedBoxToMediaBox true /PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXOutputIntentProfile () /PDFXOutputConditionIdentifier () /PDFXOutputCondition () /PDFXRegistryName () /PDFXTrapped /False /CreateJDFFile false /Description << /ARA /BGR /CHS /CHT /CZE /DAN /DEU /ESP /ETI /FRA /GRE /HEB /HRV (Za stvaranje Adobe PDF dokumenata najpogodnijih za visokokvalitetni ispis prije tiskanja koristite ove postavke. Stvoreni PDF dokumenti mogu se otvoriti Acrobat i Adobe Reader 5.0 i kasnijim verzijama.) /HUN /ITA /JPN /KOR /LTH /LVI /NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken die zijn geoptimaliseerd voor prepress-afdrukken van hoge kwaliteit. De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 5.0 en hoger.) /NOR /POL /PTB /RUM /RUS /SKY /SLV /SUO /SVE /TUR /UKR /ENU (Use these settings to create Adobe PDF documents best suited for high-quality prepress printing. Created PDF documents can be opened with Acrobat and Adobe Reader 5.0 and later.) >> /Namespace [ (Adobe) (Common) (1.0) ] /OtherNamespaces [ << /AsReaderSpreads false /CropImagesToFrames true /ErrorControl /WarnAndContinue /FlattenerIgnoreSpreadOverrides false /IncludeGuidesGrids false /IncludeNonPrinting false /IncludeSlug false /Namespace [ (Adobe) (InDesign) (4.0) ] /OmitPlacedBitmaps false /OmitPlacedEPS false /OmitPlacedPDF false /SimulateOverprint /Legacy >> << /AddBleedMarks false /AddColorBars false /AddCropMarks false /AddPageInfo false /AddRegMarks false /ConvertColors /ConvertToCMYK /DestinationProfileName () /DestinationProfileSelector /DocumentCMYK /Downsample16BitImages true /FlattenerPreset << /PresetSelector /MediumResolution >> /FormElements false /GenerateStructure false /IncludeBookmarks false /IncludeHyperlinks false /IncludeInteractive false /IncludeLayers false /IncludeProfiles false /MultimediaHandling /UseObjectSettings /Namespace [ (Adobe) (CreativeSuite) (2.0) ] /PDFXOutputIntentProfileSelector /DocumentCMYK /PreserveEditing true /UntaggedCMYKHandling /LeaveUntagged /UntaggedRGBHandling /UseDocumentProfile /UseDocumentBleed false >> ] >> setdistillerparams << /HWResolution [2400 2400] /PageSize [612.000 792.000] >> setpagedevice