id	author	title	date	pages	extension	mime	words	sentence	flesch	summary	cache	txt
gi-2483	Braun, Jaroslav; Dvořáček, Filip; Štroner, Martin	Absolute Baseline for Testing of Electronic Distance Meters	2014	6	.pdf	application/pdf	2386	130	55	Leica Absolute Tracker AT401 (standard deviation of distance measurement: 5 µm, standard deviation of angle measurement: 0.15 mgon), which is designed for very accurate industrial measurements, was used for our purpose. The base is at present used for testing of distance meters instruments useful in indoor industrial measurements and for determining the size of their errors.	cache/gi-2483.pdf	txt/gi-2483.txt