id	author	title	date	pages	extension	mime	words	sentence	flesch	summary	cache	txt
hjic-1034	Baldea, M. ; Cristea, V. M.; Agachi, P. S.	A FUZZY LOGIC APPROACH TO THE CONTROL OF THE DRYING PROCESS	2002	4	.pdf	application/pdf	1961	95	54	The behaviour of three investigated control methods (Fuzzy Logic Control- FLC, Model Predictive Control-MPC and PID control) is presented comparatively. For the ramp sections, as in Fig.8 (detail B on Fig.4), the MPC and PID control proved to be less accurate than FL showing a larger offset.	cache/hjic-1034.pdf	txt/hjic-1034.txt