International Journal of Human and Health Sciences Vol. 05 No. 01 January’21 90 Original Article: Spinal Anaesthesia Induced Hypotension and Related Adverse Effects in Caesarean Section Delivery and Neonatal Outcome: A Comparison of Using Crystalloid Pre-Loading and Co- Loading in Caesarean Patients Taneem Mohammad1, Moinul Hossain Chowdhury2, Shamima Akter1,Mohammad Abdul Karim Miah1,Mohammad Mohsin3, SM Ahsanul Habib4, Arifa Sultana5 Abstract: Background: Volume loading by rapid infusion of crystalloid solution before/during induction of spinal anaesthesia may effectively reduce the incidence of anaesthesia induced hypotension. Objective:To compare the efficacy of crystalloid pre-loading and co-loading to preventhypotension and related adverse effects as well aspoor neonatal outcome in caesarean section delivery under spinal anaesthesia. Methods:This single blinded randomized controlled clinical trial was conducted in the Department of Anaesthesia, Analgesia & Intensive Care, Dhaka Medical College Hospital, Dhaka, between January 2013 and December 2014. A total of 90 patients were selected –45patients of group I received co-loading with Ringer’s lactatesolution, while another 45 patients of group II received a pre-loading of the same fluid.Blood pressure and heart rate were recorded. Ephedrine and adrenaline were administered as needed to treat hypotension.APGAR scores of the newborn were recorded at 1st minute and 5th minute after delivery. Adverse effects like nausea, vomiting, light headedness and shivering was observed all through during operation and post-operative phase in all patients, if any, and recorded.Results:The incidence of hypotension was 17 (37.8%) in group I (co-loading) and 27 (60%) in group II (pre-loading), which was significantly higher in group II (p<0.05).Adverse effects – nausea, vomiting, light headedness and shivering was observed more in group II patients; however, the difference was not statistically significant. In neonates, APGAR score at 1 minute was found ≤7 in 18 (40.0%) from group I, while 28 (62.2%) from group II; the difference was statistically significant (p<0.05). No significant difference was observed in APGAR score at 5 minutes, as found ≤7 in 6 (13.3%) and 3 (6.7%) in group I andgroup II respectively.Conclusion:Severity of hypotension, increased ephedrine requirement and poor APGAR score wereevident in patients who received crystalloid pre-loading group(group II), which meanscrystalloid co-loading group(group I) procedurewas more effective in preventing spinal anaesthesia induced hypotension and secured better neonatal outcome. Keywords: Crystalloid pre-loading, crystalloid co-loading, spinal anaesthesia, hypotension, neonatal outcome, APGAR score. Correspondence to: Dr. Taneem Mohammad, Assistant Professor, Department of Anaesthesia, Analgesia, Palliative and Intensive Care Medicine, Dhaka Medical College Hospital, Dha- ka-1000, Bangladesh. Email: mtaneem@yahoo.com 1. Assistant Professor, Department of Anaesthesia, Analgesia, Palliative and Intensive Care Medicine,Dhaka Medical College Hospital, Dhaka-1000, Bangladesh. 2. Assistant Professor, Department of Anaesthesia and Intensive Care Medicine,Shaheed Tajuddin Ahmad Medical College Hospital,Gazipur-1700, Bangladesh. 3. Assistant Professor, Department of Critical Care Medicine, Dhaka Medical College Hospital, Dhaka-1000, Bangladesh. 4. Senior Registrar, Department of Anaesthesia, ICU and Pain Medicine, Apollo Hospitals, Dhaka-1229, Bangladesh. 5. Senior Registrar, Department of Obstetrics & Gynaecology, Apollo Hospitals, Dhaka-1229, Bangladesh. International Journal of Human and Health Sciences Vol. 05 No. 01 January’21 Page : 90-95 DOI: http://dx.doi.org/10.31344/ijhhs.v5i1.240 Introduction: Spinal anaesthesia has become a commonly used technique for elective and emergency caesarean section operation, as it is relatively cheaper, easily administered and rapidly acting technique, havinggood quality of sensory and motor block1,2. It helps the mother remain awake for the birth and comfortable afterwards as well 91 International Journal of Human and Health Sciences Vol. 05 No. 01 January’21 as avoids complications and risks associated with general anaesthesia3,4. However, spinal anaesthesia is also not without disadvantages;it is associated with high incidence of hypotension, which is more common and profound in pregnant population that can result in both maternal and neonatal morbidities2-5.Spinal anaesthesia causes sympathetic blockade and this reduces blood pressure by systemic vascular resistance and venodilatation in the lower extremity of the body, which becomes more aggravated in pregnancy by the effect of gravid uterus and associated aorto-caval compression2,5,6.Moreover, increased sensitivity to spinal anaesthetics in pregnancy due to higher progesterone levels, hypotension induce more nausea and vomiting, cardiovascular collapse and loss of consciousness in the mother2,6. Besides, prolonged hypotension can cause fetal hypoxia and acidosis resulting in a possibility of lower APGAR score in newborns due to consequence ofreductionin uterine blood flow, which is ultimately pressure dependent6.Hence, prevention of episodes of hypotension due to spinal anaesthesia for caesarean section operation always remains as an important issue for an anaesthesiologist. The practice of volume loadingapparently reduce the high incidence of hypotension in obstetric patients, as first introduced over 50 years back7. Though some of the earlier studies demonstrated immense success of crystalloid preloading8,9, the results of those studies have been questioned by the other investigators10-12. In the recent past, co- loading has generated interest for the prevention of spinal-induced hypotension and suggested that it is more rational approach for the prevention of post spinal hypotension13,14. Co-loading might be physiologically more appropriate because the maximum effect can be achieved during the time of the block and possibly increase intravascular volume expansion during vasodilatation from the sympathetic blockade and limit fluid redistribution and excretion13,14.Hence, present study was designed to compare the efficacy of crystalloid pre-loading and co-loading to prevent spinal anaesthesia induced hypotensionand related adverse effects in caesarean section delivery and neonatal outcome in those two groups. Methods: This single blinded randomized controlled clinical trial was conducted in the Department of Anaesthesia, Analgesia,Palliative and Intensive Care Medicine Care, Dhaka Medical College Hospital, Dhaka, from January 2013 to December 2014.Our study population was all the patients admitted in Department ofObstetrics &Gynaecology in the same hospital who underwent caesarean section operation.However, convenient sampling technique was adopted. The patients were selected after fulfilling the following inclusion and exclusion criteria: Inclusion criteria: 1. Patients(pregnant women) with singleton, uncomplicated pregnancy who underwent caesarean section done under spinal anaesthesia. Exclusion criteria: 1. Patients with congenital heart disease, chronic hypertension, gestational hypertension, pre-eclampsia, eclampsia; 2. Patients contraindicated for spinal anaesthesia; and 3. Patients refused to participate in the study. After fulfilling the inclusion and exclusion criteria, finally 90 pregnant women were allocated into two groups with 45 in each group. They were grouped by odd and even number and allocated to receive either crystalloid pre-loading or co-loading during caesarean section operation. The co-loading group was named group-I and pre-loading group was named group-II. Group II (pre-loading) received of 20ml/kg of Ringers lactate solution over a period of 20minutes before spinal anaesthesia and group I (co-loading) received20ml/kg of Ringers lactate solution after the spinal anaesthesia by pressurized infusion pump. In the operation theatre, blood pressure, heart rate was measured, heart and lung were examined and recorded. The anaesthesia procedure was explained to the patient. Intravenous access was secured with 18G IV cannula. Ringer’s lactate fluid was infused at the rate of 5 drops per minute to keep the cannula patent and monitoring of electrocardiogram and pulse oximetry was applied.The patients of group II (pre-load) received 20ml/kgRinger’s lactate solution over a period of 20 minutes before spinal anaesthesia. Spinal anaesthesia was conducted with the patient in the right lateral position. With all aseptic preparation, the skin and subcutaneous tissue were infiltrated with local anaesthetics. Spinal anaesthesia was given using 2.5 ml of 0.5% of hyperbaric bupivacaine, injected slowly over 12 seconds at the L2-3 or L3-4 level with a 25G Quincke needle.Patients of group I (co- load) received same Ringers lactate fluid load of International Journal of Human and Health Sciences Vol. 05 No. 01 January’21 92 20ml/kg fluid by pressurized infusion pump after observing the free flow of cerebrospinal fluid. After spinal anaesthesia injection, dressing was applied and immediately put into supine position. Urinary catheter was inserted in all patients, and a wedge was placed for 15 degree left lateral tilt. Once the fluid bolus was given, infusion rate decreased to a maintenance rate of 100ml/hour. The quality of the sensory block was assessed by swab soaked in alcohol. Surgery was proceeded after confirmation of block to T4 level.Blood pressure and heart rate were recorded in both the groups with 3-minute intervals from the beginning of the subarachnoid block for the first 20 minutes, and then with 5-minute intervals up to one hour. Spinal anaesthesia induced hypotension was defined as a decrease in the systolic arterial pressure (SAP)>20% from the baseline reading or a decrease of SAP to less than 80 mmHg as an absolute value. Hypotension was treated by bolus doses of ephedrine (5mg). If the systolic arterial blood pressure decreases to less than 80 mm of Hg or less than 80% of the calculated baseline value, 5 mg ephedrine doses were administered until systolic arterial pressure recovered to normal limit. The patients who did not respond with ephedrine, inj. adrenaline was given in doses of 10µg. After delivery of the baby, all patients received 10 IU of Inj. oxytocin bolus and 20 IU was mixed in the Ringer’s lactate solution, which was infused slowly. APGAR scores of the newborn were recorded at 1st minuteand 5th minute after delivery. Adverse effects like nausea, vomiting, light headedness andshivering was observed all through during operation and post-operative phase in all patients, if any, and recorded. Statistical analyses were done using the SPSS version 19.0 for Windows (SPSS Inc., Chicago, Illinois, USA). The mean values were calculated for continuous variables. The qualitative observations were counted by frequencies and expressed in percentages. Chi-Square test was used to analyze the categorical variables, while Student t-test was used for continuous variables. P values <0.05 was considered as statistically significant. Results: Most of the patients belonged to age group ≤30 years in both trial groups. The mean age was 24.4±4.4 years in group I (co-loading) and 25.5±4.0 years in group II (pre-loading). Mean age difference was not statistically significant between the groups (Table 1).The incidence of hypotension was 17(37.8%) in group I (co-loading) and 27(60%) in group II (pre-loading), which was significantly higher in group II(p<0.05) (Table 2).Ephedrine was required in 17 cases (37.8%) in group I and 27 cases (60%) in group II.Mean ephedrine required was 9.2±3.6 mg in group I and 11.5±4.3 mg in group II. The difference was statistically significant (p<0.05) (Table 3). Adrenaline was administeredin 1 case (2.2%) in group I and in 2 cases (4.4%) in group II.However, the difference was not statistically significant (p>0.05) (Table 3).Among the side effects of hypotension, nausea and vomiting werereported by14(31.1%) and 3 (6.7%) in group I, while 12(26.7%) and9(20.0%) ingroup II respectively. Light headedness wasreported by 10(22.2%) and 11(24.4%), while shivering was reported by 9(20.0%) and 12(26.7%) of group I and group II respectively.However, the difference was not statistically significant among the variables between two groups(p>0.05) (Table 4).In the neonates, APGAR score at 1 minute was found ≤7 in 18(40.0%) from group I, while 28(62.2%) from group II, which was statistically significant (p<0.05). APGAR score at 5 minutes was found ≤7 in 6(13.3%) from group I, while in 3(6.7%) from group II. The difference was not statistically significant (p>0.05) (Table 5). Table 1: Distribution of the study patients by age (n=90) Age (years) Group-I (n1=45) Group-II (n2=45) P value 0.211NS Frequency % Frequency % ≤30 38 84.4 37 82.2 >30 7 15.6 8 17.8 Mean±SD 24.4±4.4(18-35) 25.5±4.0 (19-36) Figures in the parentheses indicate range. NS = not significant; P value reached from unpaired Student-t test. Table 2: Distribution of the study patients by hypotension (n=90) Hypotension Group-I (n1=45) Group-II (n2=45) P value Frequency % Frequency % 0.034S No hypotension 28 62.2 18 40.0 Hypotension occurred 17 37.8 27 60.0 S = significant; P value reached from Chi-square test. 93 International Journal of Human and Health Sciences Vol. 05 No. 01 January’21 Table 3: Ephedrine and adrenaline requirement in management of hypotension (n=90) Medication Group I Group II P value Ephedrine Requirement 17 (37.8%) 27 (60.0%) 0.006S Mean Ephedrine Requirement (mg) 9.2±3.6 11.5±4.3 0.007 S Adrenaline Requirement 1 (2.2%) 2 (4.4%) 0.500NS Figures in the parentheses indicate percentage. S = significant, NS = not significant; P value reached from unpaired Student-t test. Table 4: Distribution adverse effects of hypotension (n=90) Complications Group-I (n1=45) Group-II (n2=45) P value Frequency % Frequency % Nausea Present 14 31.1 12 26.7 0.641NS Absent 31 68.9 33 73.3 Vomiting Present 3 6.7 9 20.0 0.062NS Absent 42 93.3 36 80.0 Light headedness Present 10 22.2 11 24.4 0.803NS Absent 35 77.8 34 75.6 Shivering Present 9 20.0 12 26.7 0.454NS Absent 36 80.0 33 73.3 NS = not significant; P value reached from Chi-square test. Table 5: Neonatal outcome by APGAR score (n=90) APGAR score Group-I (n1=45) Group-II (n2=45) P value Frequency % Frequency % 1 minute ≤7 18 40.0 28 62.2 0.034S >7 27 60.0 17 37.8 5 minutes ≤7 6 13.3 3 6.7 0.242NS >7 39 86.7 42 93.3 S = significant, NS = not significant; P value reached from Chi-square test. Discussion: In this present study, most of the patients belonged to age ≤30 years in both groups. The mean age was 24.4±4.4 years in group I (co-loading group) and 25.5±4.0 years in group II (pre-loading group). The difference was not statistically significant (p>0.05) between two groups. Dyer et al.14 reported mean age 26.8±4.9 and 27.4±6.0 years for pre-load and co-load respectively, while Jacob et al.15 found mean age 26.9±2.4 years in co-load and 26.7±2.6 years in pre-load group. Oh et al.16 showed the mean age of patients in co-load group 33.7±4.0 years as compared to 33.5±3.5 years in pre-load group. The differences were not statistically significant in those studies and the results were found similar toour study. In this present study, we observed episodes of hypotension more in group II (pre-loading) in comparison to group I (co-loading), which was statistically significant. Mojica et al.13 conducted a randomized clinical trial to evaluate the efficacy of crystalloids in preventing spinal-induced hypotension (SIH) and cardiovascular side effects (CVSE) in a group of surgical patients. The incidence of SIH was similar in all treatment groups. However, compared to placebo, crystalloid administration at the time of spinal block resulted in a significant reduction in the proportion of patients developing CVSE from 9.9% to 2.3% (P<0.05). Administration of crystalloids at the time of spinal block seems to be effective because it provides additional intravascular fluids during the period of highest risk of CVSE after spinal anesthesia13. Dyer et al.14 reported 84% hypotension in the pre- load group and 60% in the co-load group. Jacob et al.15 reported that 60% of patients in the pre- loading group developed hypotension. Previous studies using 15 ml/kg of lactated Ringer’s as pre-load in the obstetric population reported the incidence of hypotension as 55%, as studied by Gajraj et al.17 and 45.5%, as found by Tercanli et al.18. However, Oh et al.16 studied comparing systolic blood pressure between the two groups at baseline, with 1 minute interval and found that hypotension occurred in 83% cases in pre-loading group and 53% in the co-loading group, which was statistically significant (P=0.026). We observed adverse effects like nausea, vomiting, light headedness and shivering more in group II patients; however, the difference was not statistically significant.Conversely, Jacob et al.15 observed significant difference – nausea19 vs. 10 and vomiting 14 vs. 6 in pre-load and co-load International Journal of Human and Health Sciences Vol. 05 No. 01 January’21 94 respectively (P<0.05), while Oh et al.16observed nausea 60% and 27% respectively. Dyer et al.14 reported that the co-load group required a lower median dose (P=0.03) and a lower median number(P=0.04) of ephedrine doses for the treatment of maternal hypotension pre- delivery. Nevertheless, there was no difference in either the total cumulative dose, or in the total number of doses of ephedrine between groups. Jacob et al.15 showed that the mean number of doses of ephedrine required 2.6 vs. 1.8 and the total dose of ephedrine used 14.2 mg vs. 12.6 mg in pre-load andco-load respectively which were statistically significant. Oh et al.16 reported that smaller dose of ephedrine (7.5 mg) required in the co-load group than the pre-load group (15 mg). Evidence suggested that neonatal outcomes in terms of APGAR score was not statistically significant between pre-load and co-load groupsas recorded at birth, 1 minute and 5 minutes after birth, despite a difference in the episodes of hypotension among the groups15, unlike the findings of the present study. This reflects previous experience that transient decreases in blood pressure rapidly treated by vasopressor do not usually affect the fetal outcome19. Limitations of the study: This was a single-centre trial. The study population was selected from an urban hospital for a short period of time in Dhaka city. Hence, the results of the study may not be generalized and does notnecessarily reflect the overall picture of the country.Small sample size was another limitation of the present study.The lack of a control group or placebo group precluded determination of an absolute reduction in the incidence of hypotension (as we did not include a placebofor ethical reasons). Moreover, the study did not investigate the correlation between umbilical artery pH and spinal-delivery interval, uterine incision-delivery interval and duration of hypotension.APGAR score was taken for rapid evaluation of neonatal (fetal) outcome in place of umbilical blood pH and blood gas status as the same was not readily available in the Department ofObstetrics &Gynaecology facility. Conclusion: In summary, severity of hypotension, increased ephedrine requirement and poor APGAR score were evident in patients who received crystalloid pre-load, which means crystalloid co- loadprocedure was more effective in preventing spinal anaesthesia induced hypotension and secured better neonatal outcome. Further studies with larger sample and multi-centre trials along with high technical back up are recommended. Conflict of interest:None declared. Ethical approval issue: The study was approved by the Ethical Review Committee of Dhaka Medical College, Dhaka, Bangladesh. Funding statement: No funding. Authors’ contribution: Conceptand study design: TM; Data collection and compilation: TM, MHC, SA, MAKM, MM, SMAH, AS; Data analysis: TM, SMAH; Critical writing, revision and finalizing the manuscript: TM, MHC, SA, MAKM, MM, SMAH, AS. 95 International Journal of Human and Health Sciences Vol. 05 No. 01 January’21 References: 1. Shibli KU, Russell IF. A survey of anaesthetic techniques used for caesarean section in the UK in 1997. Int J ObstetAnesth. 2000;9(3):160-7. 2. Birnbach DJ, Brown IM. Anesthesia for obstetrics. In: Miller RD, Cohen NH, Eriksson LI, Fleisher LA, Wiener-Kronish JP, Young WL. eds. Miller’s Anesthesia. 8th ed. Philadelphia: Elsevier/Churchill Livingstone; 2005. 3. Hawkins JL, Koonin LM, Palmer SK, Gibbs CP. Anesthesia-related deaths during obstetric delivery in the United States, 1979-1990. Anesthesiology. 1997;86(2):277-84. 4. At A, So O. Failed spinal anaesthesia for caesarean section. J West Afr Coll Surg. 2011;1(4):1-17. 5. Van De Velde M. Spinal anesthesia in the obstetric patient: prevention and treatment of hypotension. Acta Anaesthesiol Belg. 2006;57(4):383‐6. 6. Maayan-Metzger A, Schushan-Eisen I, Todris L, Etchin A, Kuint J. Maternal hypotension during elective cesarean section and short-term neonatal outcome. Am J Obstet Gynecol. 2010;202(1):56. e1‐5. 7. Greiss FC, Crandell DL. Therapy for hypotension induced by spinal anesthesia during pregnancy: observations on gravid ewes. JAMA. 1965;191(10):793-796. 8. Wollman SB, Marx GF. Acute hydration for prevention of hypotension of spinal anesthesia in parturients. Anesthesiology. 1968;29(2):374‐80. 9. Clark RB, Thompson DS, Thompson CH. Prevention of spinal hypotension associated with Cesarean section. Anesthesiology. 1976;45(6):670‐4. 10. Rout C, Rocke DA. Spinal hypotension associated with Cesarean section: will preload ever work? Anesthesiology. 1999;91(6):1565‐7. 11. Tamilselvan P, Fernando R, Bray J, Sodhi M, Columb M. The effects of crystalloid and colloid preload on cardiac output in the parturient undergoing planned cesarean delivery under spinal anesthesia: a randomized trial. AnesthAnalg. 2009;109(6):1916‐21. 12. McDonald S, Fernando R, Ashpole K, Columb M. Maternal cardiac output changes after crystalloid or colloid coload following spinal anesthesia for elective cesarean delivery: a randomized controlled trial. AnesthAnalg. 2011;113(4):803‐10. 13. Mojica JL, Meléndez HJ, Bautista LE. The timing of intravenous crystalloid administration and incidence of cardiovascular side effects during spinal anesthesia: the results from a randomized controlled trial. AnesthAnalg. 2002;94(2):432-7. 14. Dyer RA, Farina Z, Joubert IA, du Toit P, Meyer M, Torr G, et al. Crystalloid preload versus rapid crystalloid administration after induction of spinal anaesthesia (coload) for elective caesarean section. Anaesth Intensive Care. 2004;32(3):351-7. 15. Jacob JJ, Williams A, Verghese M, Afzal L. Crystalloid preload versus crystalloid coload for parturients undergoing cesarean section under spinal anesthesia. J ObstetAnaesthCrit Care. 2012;2(1):10- 15. 16. Oh A-Y, Hwang J-W, Song I-A, Kim M-H, Ryu J-H, Park H-P, et al. Influence of the timing of administration of crystalloid on maternal hypotension during spinal anesthesia for cesarean delivery: preload versus coload. BMC Anesthesiol. 2014;14:36. 17. Gajraj NM, Victory RA, Pace NA, Van Elstraete AC, Wallace DH. Comparison of an ephedrine infusion with crystalloid administration for prevention of hypotension during spinal anesthesia. AnesthAnalg. 1993;76(5):1023‐1026. 18. Tercanli S, Schneider M, Visca E, Hösli I, Troeger C, Peukert R, et al. Influence of volume preloading on uteroplacental and fetal circulation during spinal anaesthesia for caesarean section in uncomplicated singleton pregnancies. Fetal Diagn Ther. 2002;17(3):142-146. 19. Macarthur A. Solving the problem of spinal induced hypertension in obstetric anaesthesia. CanJ Anaesth. 2002;49(6):536-9.