Reem.doc J Bagh College Dentistry Vol. 27(1), March 2015 Evaluation of shear Restorative Dentistry 77 Evaluation of shear bond strength of zirconia to tooth structure after different zirconia surface treatment techniques Reem Mounes Dawood, B.D.S. (1) Adel F. Ibraheem, B.D.S., M.Sc. (2) ABSTRACT Background: This study aimed to evaluate the effect of zirconia different surface treatments (primer, sandblast with 50μmAl2O3, Er,Cr:YSGG laser) on shear bond strength between zirconia surface and resin cement. Material and methods: Sixty presintered Y-TZP zirconia cylinder specimens (IPS e.max ZirCAD, Ivoclar vivadent) will be fabricated and sintered in high temperature furnace of (1500 C for 8 hours) according to manufacturer’s instructions to the selected size and shape of (5mm. in diameter and 6mm in height). All specimens were ground flat using 600.800.1000.1200, aluminum oxide abrasive paper to obtain a standardized surface roughness. Surface roughness values were then recorded in µm using surface roughness tester (profilometer) to obtain a standardized data base line for all samples. The specimens were then randomly divided into three main groups (n=20); group A: no surface treatment (control group), group B: specimens in this group treated with 50μm Al2O3 and group C: specimens in this group treated with Er,Cr:YSGG laser. Sixty sound human premolars were used in this study, after construction of acrylic blocks, the occlusal surface of the teeth were ground flat, with diamond cutting disk to obtain a flat dentine surface . Prior to cementation of zirconia cylinders to tooth specimens subgroups (A1,B1,C1) will receive a coat of metal/zirconia primer and left to react for three minutes, while the subgroups (A2,B2,C2) were left undisturbed. Bonding surface of zirconia cylinder was then luted with SpeedCEM self adhesive resin cement under a static load of 2Kg. placed on the vertical arm of the surveyor and allowed to auto cure for 4minutes.The final cemented specimens were then stored in distilled water at room temperature for 24hours. All specimens were subjected to shear loading force in a universal testing machine at crosshead speed of 1mm/min. The shear bond strength values were analyzed statistically with one-way ANOVA; the fractured surfaces of zirconia cylinders were examined with a stereo-microscope to observe the failure mode. Results: The air borne-particle of 50μm followed by primer application showed significantly the higher bond strength than other groups. Conclusion: Within the limitation of this study, the results showed that sandblasting the bonding surface of zirconium cylinders with 50μmAl2O3 produced the highest values of shear bond strength , also the use of primer enhanced shear bond strength as well. Keyword: Zirconia surface treatments, shear bond strength. (J Bagh Coll Dentistry 2015; 27(1):77-85). INTRODUCTION In recent years, there is increasing demand for metal free restoration due to the increasing interest in aesthetic. Both patients and clinicians have been seeking superior aesthetic metal free tooth colored restorations (1). All ceramic restorations provide the most aesthetic pleasing restorations; significant effort has been made over the years to improve their brittleness and low tensile strength. Zirconium oxide–based materials, especially yttria- tetragonal zirconia polycrystals (Y-TZP), were introduced for prosthetic rehabilitations as a core material for single crowns, conventional and resin-bonded fixed partial dentures (FPDs) (2) and, in dental implantology, as abutments or implants Furthermore the combination of Y-TZP and computer-aided design/computer-aided manufacture (CAD/CAM) systems reduces the number of steps in prosthetic manufacturing and eliminates the variables introduced by the manual procedures of the dental technician. (3) (1) Master Student. Department of Conservative Dentistry, College of Dentistry, University of Baghdad. (2) Professor, Department of Conservative Dentistry, College of Dentistry, University of Baghdad. Y-TZP exhibits exceptional physical and mechanical properties, such as high flexural strength, fracture toughness, hardness, wear and corrosion resistance in acidic and basic ambient conditions, translucency colour stability, greater effectiveness of diagnostic radiographs (4, 5, 6) and high biocompatibility. Moreover, the polycrystalline structure, which lacks a glass matrix, makes zirconia ceramic more resistant to hydrofluoridric acid etching and, as a consequence, resistant to chemical roughening (7). Reliable cementation of fixed prosthetic restorations represents one of the most sensitive and crucial tasks during the dental treatment with desirable long term clinical success. Because of its particular structure, zirconia restorations require a special conditioning before cementation in order to achieve a strong bond to dentine, as the clinical success of ceramic restorations depends on the cementation process (8). For this reason, different approaches have been used to enhance the bond between the zirconia and resin cements, such as coating methods (9), a selective infiltration-etching technique (10). Phosphate ester monomer, 10- methacryloyloxydecyl dihydrogen phosphate J Bagh College Dentistry Vol. 27(1), March 2015 Evaluation of shear Restorative Dentistry 78 (MDP) based materials (4), Surface roughening by airborne-particle abrasion, and surface roughening by the use of laser. MATERIALS AND METHODS Fabrication of zirconia samples: Sixty zirconia cylinders were milled from Pre- sintered Y-TZP zirconium oxide blocks (IPS e.max ZirCAD, Ivocalr Vivadent),with the dimensions of(19 mm,15.5mm,55mm), each zirconia blank was detached from its fitting pin ,each blank was divided into two halves with a cutting saw, each half was divided longitudinally into four equal parallel sided shaped blank by a cutting saw as well, each part was then glued into the fitting pin Figure (1), the fitting pin was then placed into the designated place in the milling machine. A straight hand piece with a carbide round bur operating at high speed was fixed to the movable member of the milling machine in a way allowing back and forth free movement of it along the zirconia parallel sided blank figure (2), in this way each parallel sided blank was cut into a cylinder shaped blank of 6.25mm in diameter figure (3), Each cylindrical blank was cut by a diamond cutting disk into 3 cylinders, each cylinder was measured 7.5 mm in height figure (4). Figure 1: Parallel sided blank glued on the fitting pin Figure 2: Milling and cutting the zirconium parallel sided blank Figure 3: Cylindrical zirconia blank Figure 4: Cutting cylindrical blank with diamond disk The obtained cylinders were then sintered in tube furnace (Infire HTC speed sintering furnace, Sirona) at 1500 oC for 8 hours including cooling, according to manufacturer’s instructions. During this process a 3-dimensional volumetric J Bagh College Dentistry Vol. 27(1), March 2015 Evaluation of shear Restorative Dentistry 79 shrinkage of the milled cylinder of approximately 20% took place that is why the cylinders were milled approximately 20% larger. Following sintering each zirconia cylinder was measured approximately (5mm in diameter, 6mm in height) figure (5) Figure 5: Final shape and size of the zirconia cylinders The bonding surfaces of zirconia cylinders were then ground flat using a grinding machine and polished consecutively with 600, 800,1000 and 1200-grit silicon carbide abrasive papers under water cooling to obtain standardized surface roughness (11), to facilitate handling the zirconia cylinder during the polishing process a custom made holder was fabricated figure (6). Figure 6: Custom made holder Surface roughness for each sample was then confirmed by the use of the profilometer to ensure standardization. Before the surface treatments, all specimens were ultrasonically cleaned in distilled water for 3 minutes to remove contaminants. Then, the specimens were randomly assigned into three groups of equal size, (n = 20), according to the surface treatments were used. Specimens grouping Sixty zirconia cylinders were divided into 3 main groups (n=20) according to the surface treatment that had been applied: Group A: 20 zirconia cylinders were left without treatment (control group) Group B: 20 zirconia cylinders were treated with Er,Cr:YSGG laser. Group C : 20 zirconia cylinders were treated with sand blast (50 µm Al2O3). Prior to cementation each group was subdivided into two subgroups one of them received a coat of primer while the other was without treatment Treatment of the bonding surface of the zirconia cylinder: Preparation of zirconia samples before surface treatment: Prior to surface treatment the specimens were cleaned with 70% ethanol by wiping their surfaces with cotton and subsequently cleaning them for five minutes in an ultrasonic bath with ethanol (12). Group A (control group): No treatment was performed to this group and it is considered as the control group. Prior to cementation the specimens were cleaned with 70% ethanol by wiping their surfaces with cotton and subsequently cleaning them for five minutes in an ultrasonic bath with ethanol (12). Group B (Er,Cr:YSGG Laser treatment) An Er, Cr: YSGG laser system (Waterlase MD, Biolase) was used on the bonding surface of each zirconia cylinder. A custom made holder was made especially to keep the distance between the tip of the device and the zirconia bonding surface fixed at 1 mm, Er,Cr: YSGG laser , λ = 2780 nm, pulsed laser-powered hydrokinetics, and the power was 2.5 W with a 6mm quartz core tip (G4, Biolase Technologies Inc., Irvine, CA, Germany) positioned at 1 mm (90°) from the bonding surface of each zirconia cylinder (focused mode) (13). Repetition rate was fixed on 20 Hz., the air and water were adjusted to 50% of the laser unit. Irradiation was done under the supervision of a laser specialist. Each sample was irradiated in a circular motion for 30 sec. to promote homogeneous irradiation and cover the entire sample area figure (7). (14) Then, the specimens were cleaned with 70% ethanol by wiping their surfaces with cotton and subsequently cleaning them for five minutes in an ultrasonic bath with ethanol (12). J Bagh College Dentistry Vol. 27(1), March 2015 Evaluation of shear Restorative Dentistry 80 Figure 7: Er,Cr:YSGG, laser irradiating Zirconia bonding surface Group C (Sand blast treatment) Zirconia cylinders were mounted in a special holder so that the blasting tip is in a straight line with the sample at a distance of 10mm between the surface of the zirconia cylinder and the blasting tip of the airborne-particle hand-piece, The surfaces of the specimens were air particle abraded for 15 s with 50 μm Al2O3 particles at 2.5 bars Then, the specimens were cleaned with 70% ethanol by wiping their surfaces with cotton and subsequently cleaning them for five minutes in an ultrasonic bath with ethanol (12). Figure 7: Placing the blasting tip in a straight line with the zirconium surface Preparation of teeth samples: Teeth selection: Non-carious, un restored sixty, freshly extracted, upper first human premolars, for orthodontic purposes (the patient age range from 13-20years), of comparable size and shape were selected and collected for this study, All teeth were examined under a magnifying eye lens &light from a light curing unit to check for the absence of caries, cracks, fractures, and restoration. Only intact teeth free of defect were selected. The teeth were then cleaned from debris by using slurry of pumice in a rubber cup used with a low speed hand piece, then, washed with distilled water The teeth were stored in normal saline at room temperature until sample preparation. Construction of acrylic blocks: A custom made square rubber mold of (1cm x 1cm x 2cm) was used for construction of acrylic blocks for this study. The root of each tooth was embedded along their long axes in mixed cold cure acrylic to about 3mm. Occlusal to the cementoenamel junction. A dental surveyor was used to position the clinical crown parallel to that of the acrylic resin block. Preparation of teeth A standardized occlusal surface reduction was obtained for all samples by using a surveyor; straight hand piece with a diamond cutting disc operating at high speed was adapted to the horizontal arm of the surveyor in such a way so that the long axis of the disc was kept parallel to the long axis of the tooth. The movable table of the surveyor was adapted by using a special mold to hold each sample during cutting procedure to secure each specimen in such way so that the long axis of each clinical crown was parallel to the shaft of the cutting disk. Thus, the long axis of the bur will be kept parallet to the long axis of the tooth sample all the way during occlusal surface reduction. For each tooth sample the occlusal surface was reduced to the depth of the central groove with diamond disc using high speed hand piece, with copious water cooling, to expose the upper part of the peripheral dentine surface, a new cutting disc was used every (5) teeth Then the dentin surface was prepared with 240, 400, and 600 grit aluminum oxide abrasive papers, respectively under running tap water for 10 seconds each to obtain a polished surface (15) The teeth were kept hydrated in distilled water as this storage solution will not alter the permeability of dentine (16). The storage solution was stored in the refrigerator (17). After that the teeth specimens were distributed evenly among the six subgroups. Bonding of zirconia cylinder to tooth surface In order to have a standardized bonding procedure, an adhesive tape with a 5mm hole in diameter was fixed on the dentine surface of each prepared tooth to restrict the bonding area to a diameter of 5 mm. Prior to cementation a coat of Metal zirconia primer was applied to the bonding surface of the subgroups (A2,B2,C2) of zirconia cylinder (18) with a microbrush and left to react for 180 J Bagh College Dentistry Vol. 27(1), March 2015 Evaluation of shear Restorative Dentistry 81 seconds according to manufacturer‘s instructions, and dried with water and oil free air. Speed CEM (Ivoclar Vivadent) self curing resin cement was used as a luting agent in this study, it was automixed and dispensed using disposable mixing tips supplied with the cement kit and applied directly as a thin, even layer onto the zirconia cylinder bonding side. The bonding side of zirconia was then seated onto its respective area on the bonding surface of the prepared tooth with finger pressure .For standardization, a dental surveyor was used during cementation procedure ,tooth sample was secured by using a special mold to hold each tooth sample to the movable table of the surveyor, the upper part of the vertical arm of the surveyor was used to apply a static load of 2 Kg. to the zirconium block during bonding procedure to the tooth, this load is used to avoid any internal cement gaps (19) and to standardize the cementation process. Excess cement was then removed using cotton pellet, light polymerization was carried out for 20 sec. per surface at 1200mW/cm2 (following the manufacturer’s instructions. Then each cemented specimen was kept under the load for 4 minutes according to the manufacturer’s instructions, and kept for one hour to bench set for complete curing. One hour after cementation, specimens were stored in distilled water in a dark container at room temperature for 24hours (20). Shear bond strength test The specimens were attached to a universal testing machine, (Tinius Olsen, H50KT, UK).and subjected to a shear force using a stainless steel chiseled-shaped rod with across head at a crosshead speed of 1mm/min until failure occurred. The tested specimens were placed in the lower part (jaw) of the testing machine. While the acrylic block was held in a horizontal position in such a way that the long axis of the chisel shaped rod is placed parallel to the occlusal surface of the tooth, The chisel end of the rod was positioned at the interface between the tooth surface and the zirconia cylinder interface, so that distance between chisel and the interface was 0.1 mm to avoid a cantilever effect on the adhesive surface (21). The specimen was secured tightly in place so that to ensure that the zirconia cylinder was always at 90 degree to the vertical plane, the specimens were stressed to failure. The Shear bond test values were calculated from this measurement and expressed in MPa. Fig. (2-26). Shear strength [MPa] = maximum force [N] / bonding area [mm2]. Light Microscope Examination The fractured specimens were examined after debonding to determine the mode of failure. The specimens were examined under light microscope (BioVision line, Italy) at magnification of 40 X to evaluate the fracture pattern. Failure modes were classified into: 1. Adhesive failure: If more than 75% of the zirconia cylinder surface was visible. 2. Cohesive failure: If more than 75% of the zirconia cylinder surface was covered with resin. All other cases were classified as mixed failures. RESULTS Descriptive statistics A total of 60 measurements of shear bond strength from six groups were recorded for six different surface treatments (Appendix I). The means and standard deviations of shear bond strength with minimum and maximum values for each group are shown in Table (1). Table 1: Descriptive statistics of the shear bond strength of different zirconia surface treatment. Groups Descriptive statistics Mean S.D. Min. Max. No treatment without primer A1 1.66 0.29 1.12 2.06 No treatment with primer A2 2.77 0.23 2.45 3.06 Laser without primer B1 4.68 0.32 4.13 5.07 Laser with primer B2 5.72 0.28 5.2 6.04 Sand blast without primer C1 7.25 0.38 6.63 7.79 Sand blast with primer C2 8.40 0.52 7.64 9.08 Table (1) shows the lowest mean of shear bond strength was detected in group A1 (1.66±0.29), while the highest mean (8.40±0.52) was detected in group C2. Figure 8: Bar-chart showing the mean values of the shear bond strength of the six groups. J Bagh College Dentistry Vol. 27(1), March 2015 Evaluation of shear Restorative Dentistry 82 Inferential statistics Within the single group (Effect of primer) To see whether there is statistically significant difference within the group (between the subgroups), Student’s t-test was applied Table (2). Table 2: Student’s t -test. Tested groups Comparison d.f.=18 t-test p-value A1 VS. A2 9.57 0.000(HS) B1 vs .B2 7.74 0.000(HS) C1 vs.C2 5.6 0.000(HS) *P≤0.05 Significant(S), P≤0.01 Highly significant (HS), P≤0.001 very Highly significant (VHS) t-test showed that group A1that there is statistically high significant difference between the subgroups according to the application of primer. Among the groups (Effect of the surface treatment) To see whether the difference in the mean value for the subgroups (A1,B1,C1) were statistically significant or not, one way (ANOVA) test was applied in Table (3). Table 3: One way-ANOVA between and within groups (A1,B1,C1). Sum of Squares d.f Mean Square F- test p- value Between Groups 156.40 2 78.20 708.0 9 0.000 (HS) Within Groups 2.98 27 0.11 Total 159.38 29 Table (3) shows that the difference in shear bond strength for the groups (A1,B1,C1)were statistically highly significant. To examine the source of the difference Among the subgroups (A1, B1,C1). Further analysis of these subgroups was performed using LSD test table (4). Table 4: LSD test among (A1,B1,C1) subgroups Groups Mean Difference p-value A1 B1 -3.02 0.000 (HS) C1 -5.59 0.000 (HS) B1 C1 -2.57 0.000 (HS) Table (4) shows that there is highly significant difference between subgroups. And to see whether the difference in the mean value for the groups (A2,B2,C2) were statistically significant or not, one way (ANOVA) test was applied in Table (5). Table 5: One way-ANOVA between and within groups(A2,B2,C2) Sum of Squares d.f. Mean Square F-test p-value Between Groups 158.21 2 79.10 584.6 9 0.000 (HS) Within Groups 3.65 27 0.14 Total 161.86 29 Table (5) shows that the difference in shear bond strength for the groups (A2, B2, C2) was statistically highly significant. To examine the source of the difference among these groups (A2, B2, C2) Further analysis of these subgroups was performed using LSD test, Table (6). Table 6: LSD test among (A2,B2,C2) subgroups Groups Mean Difference p-value A2 B2 -2.95 0.000 (HS) C2 -5.62 0.000 (HS) B2 C2 -2.68 0.000 (HS) Table (6) shows that there is highly significant difference between the subgroups Mode of failures The results of failure mode after shear bond testing as observed with a stereomicroscope are summarized in table (7). Table 7: Modes of failures Groups Subgroups Adhesive failure Cohesive failure Mixed Failure No. % No. % No. % Group A A1 2 20 4 40 4 40 A2 1 10 5 50 4 40 Group B B1 1 10 6 60 3 30 B2 - 8 80 2 20 Group C C1 - 8 80 2 20 C2 - 9 90 1 10 This table shows that the predominant mode of failure for the sub groups (C2, C1, B2, B1) was cohesive failure as shown in the Fig (9) Adhesive failure was observed in the subgroups (A1, A2, B1) as shown in Fig. (10) Mixed failure occurred in all subgroups in low percentage as shown in fig(11) J Bagh College Dentistry Vol. 27(1), March 2015 Evaluation of shear Restorative Dentistry 83 Figure 9: Adhesive failure Figure 10: Mixed failure Figure 11: Cohesive failure DISCUSSION Effect of primer The results of this study showed that treatment of the bonding surface of zirconia with metal zirconia surface prior to cementation to tooth surface significantly improve bond strength and this is clearly shown when comparing subgroups (A2,B2,C2) with the subgroups (A1,B1,C1). This can be explained by the fact that phosphonate or phosphate monomers which are the main constituens in metal/zirconia primer, Phosphate monomers bond to zirconia by forming covalent bonds (Zr-O-P covalent bond) with its surface and have polymerizable resin terminal ends that copolymerize with the resin cements. Furthermore, the surface wetting theory recognizes a key role to the wetting capacity of the primer for improved adhesion. According to this theory the viscosity of the metal/zirconia primer would assist zirconia surface wetting, thus promoting physical adhesion. That could be attributed to phosphonate or phosphate monomers that is the main element in metal/zirconia primer, Phosphate monomers bond to zirconia by forming covalent bonds (Zr-O-P covalent bond) with zirconia bonding surface and have polymerizable resin terminal ends that copolymerize with the resin cements. This was clearly shown in this study when there was increased bonding strength of zirconia surface to dentine surface when using SpeedCEM self-adhesive luting resin cement containing a functional phosphate monomer with metal/zirconia primer that containes phosphate monomer as well The result of this study agrees with others (22- 29) whom stated that the metal primes that contain phosphate monomers, are effective for improving bond strengths between zirconia and resin cements. The effect Er,Cr:YSGG laser treatment The result of this study shows that using of Er,Cr:YSGG laser on the bonding surface of zirconia surface resulted in significantly enhanced shear bond strengths compared with the control group, probably because of the surface roughness and irregularities on the zirconia bonding surface that enhance the interlocking with the resin cements. This result is in agreement with Cavalcanti et al. (30), whom concluded that laser irradiation on zirconia bonding surface significantly increase shear bond strength due to surface roughness. However the result disagrees with Ersu et al., (31) and Aboushelib et al.(32). Whom concluded that lasers are not effective to improve the bond strength between ZrO2 and resin cement, this can Resin Composite Zirconia bonding surface Resin Composite Zirconia bonding surface Zirconia bonding surface Resin Composite J Bagh College Dentistry Vol. 27(1), March 2015 Evaluation of shear Restorative Dentistry 84 be explained by the fact that the authors in their study used different laser parameters. However the result of this study showed lower bond strength values accompanied with sandblast treatment. Effect of sandblast treatment Treating the bonding surface of zirconia with 50 µmAl2O3 Resulted in high values of shear bond strength when comparing it to laser treatment, that may be attributed to the fact that treating zirconia bonding surface with sandblast increases surface roughness and undercuts. The result of this study agrees with Cavalcanti et al. 2009(30) who showed an increase in bond strength after air-abrasion with 50 µmAl2O3 And disagrees with de Oyague et al. (33) Who concluded that air-abrasion on the bonding surface of zirconia substrate did not produce higher bond strength, even though the substrate surface became rougher than the control group, probably because of different grain size, or different pressure used in the study. Furthermore, the result of this study shows that treating zirconia bonding surface with 50 µm Al2O3 produced significant enhancement in bonding strength when comparing it with other treatment subgroups. Effect of primer with other surface treatments The result of this study has showed that using sandblast with primer give us the highest mean of shear bond strength when comparing it with other subgroups, this could be explained by the fact that using multifunctional methods ,which mix the ability to create a rough surface for micromechanical interlocking and increase the surface area to establish chemical bond with reactive substances .This was clearly shown in this study when metal/zirconia primer was applied to the zirconia bonding surface of the subgroups (A2,B2,C2) after air abrasion and Er,Cr:YSGG laser treatment, and high significant difference was noticed among these subgroups, when comparing them with subgroups (A1,B1,C1). The result is an agreement with Yang et al. (34), whom stated that the combination of primers and air-abrasion methods tend to produce better bond strength, especially in long term durations. Mode of failure Studying the results of examining of bonding surface of zirconia, by using stereomicroscope at 40X magnification, table (7) highly support the result of this study. Studying table (7) shows that mode of failures when using sandblasting treatment was mostly cohesive failure and this indicates that sandblasting the boding surface of zirconia creates high bonding to resin cement. REFERENCES 1. Cavalcanti AN, Foxton RM, Watson TF, Oliveira MT, Giannini M and Marchi GM. Bond strength of resin cements to a zirconia ceramic with different surface treatments. Operative Dentistry 2009; 34(3): 280–287. 2. Kansu G, Aydin AK. Evaluation of the biocompatibility of various dental alloys: Part I Toxic potentials. Eur J Prosthodont Restor Dent 1996; 4: 129–36. 3. Blatz MB. Long-term clinical success of all-ceramic posterior restorations. Quintessence Int 2002; 33:415– 26. 4. Raigrodski AJ. Contemporary materials and technologies for all-ceramic fixed partial dentures: A review of the literature. J Prosthet Dent 2004; 92: 557–62. 5. Odman P, Andersson B. Procera AllCeram crowns followed for 5-10.5 years: a prospective clinical study. Int J Prosthodont 2001;14: 504–509. 6. Pjetursson BE, Sailer I, Zwahlen M, Hämmerle CH. A systematic review of the survival and complication rates of all-ceramic and metal–ceramic reconstructions after an observation period of at least 3 years. Part I. Single crowns. Clin Oral Implants Res 2007; 18:73– 85. 7. Guazzato M, Quach L, Albakry M, Swain MV. Influence of surface and heat treatments on the flexural strength of Y-TZP dental ceramic. J Dent 2005; 33: 9–18. 8. Borges GA, Sophr AM, De Goes MF, Sobrinho LC, Chan DCN. Effect of etching and airborne particle abrasion on the microstructure of different dental ceramics. J Prosthet Dent 2003; 89: 479–488. 9. Zawta C. Fixed partial dentures with an all-ceramic system: A case report. Quintessence Int 2001; 32: 351–358 10. Toksavul S, Türkün M, Toman M. Esthetic enhancement of ceramic crown with zirconia dowel and cores: A clinical report. J Prosthet Dent 2004: 92: 116–9. 11. Akın H, Zeynep O, Omer K, Ender K, Ali KO. Shear bond strength of resin cement to zirconia ceramic after aluminum oxide sandblasting and various laser treatments. Photomed Laser Surg 2011; 29(12): 797– 802 12. Fischer J, Grohmann P and Stawarczyk B. Effect of Zirconia Surface Treatments on the Shear Strength of Zirconia/Veneering Ceramic Composites. Dent Mater J 2008; 27(3): 448-54 13. Alessandra G, Pérsio VM, José AR, Silvia CLH, Alberto B, Jamil AS. Thermal effects on zirconia substrate after Er,Cr:YSGG irradiation. 2013; 42(6): 439-43 14. Stubinger S, Homann F, Etter C, Wieland M, Sader R. Effect of Er:YAG, CO2 and Diode Laser Irradiation on surface properties of zirconia Endosseous Dental Implants. Lasers in Surgery and Medicine 2008; 40: 223-8. 15. Farrokh A, Mohsen M, Soheil S, Nazanin B. Shear bond strength of three self-adhesive resin cements to dentin. Indian J Dent Res 2012; 23:221-5 16. Goodis HE, Marshall GW Jr, White JM, Geel L, Hornberger B, Marshall SJ. Storage effects on dentin J Bagh College Dentistry Vol. 27(1), March 2015 Evaluation of shear Restorative Dentistry 85 permeability and shear bond strengths. Dent Mater 1993; 9(2): 79-84 17. ElGuindy JF, Mostafa DH, ElAgroudi MA. Margin assessment and fracture resistance of adhesively luted ceramic crowns. J Am Sc 2010; 6(11): 264-73. 18. Attia A, Lehmann F, Kern M. Influence of surface conditioning and cleaning methods on resin bonding to zirconia ceramic. Dent Mater 2011; 27: 207-13. 19. Beuer F, Aggstaller H, Edelhoff D, Gernet W. Effect of preparation design on the fracture resistance of zirconia crown copings. Dent Mater J 2008; 27(3): 362-7. 20. Kassem AS, Atta O, El-Mowafy O. Fatigue resistance and microleakage of CAD/CAM ceramic and composite molar crowns. J Prosthodont 2012; 21: 28- 32 21. Piwowarczyk A, Lauer HC, Sorensen JA. The shear bond strength between luting cements and zirconia ceramics after two pre-treatments. Oper Dent 2005; 30: 382–8. 22. Lehmann F and Kern M. Durability of resin bonding to Zirconia ceramic using different primers. J Adhes Dent 2009; 11: 479-483. 23. Kitayama S, Nikaido T, Ikeda M, Alireza S and Miura H et al. Internal coating of zirconia restoration with silica-based ceramic improves bonding of resin cement to dental zirconia ceramic. Biomed Mater Eng 2010; 20: 77-87. 24. Magne P,ParanhosMPG and Burnett LH. New Zirconia primer improves bond strength of resin-based cements. Dent Mater 2010; 26: 345-52. 25. Takeuchi K, Fujishima A, Manabe A, Kuriyama Sand Hotta Y, et al. Combination treatment of tribochemical treatment and phosphoric acid ester monomer of Zirconia ceramics enhances the bonding durability of resin-based luting cements. Dent Mater J 2010; 29: 316-323. 26. Ural C, Kulunk T, Kulunk S, Kurt M and Baba S. Determination of resin bond strength to Zirconia ceramic surface using different primers. Acta Odontol Scand 2010; 69: 48-53. 27. Cura C, Ozcan M,Isik G and Saracoglu A. Comparison of alternative adhesive cementation concepts for Zirconia ceramic: Glaze layer vs. Zirconia primer. J Adhes Dent 2011; 14: 75-82. 28. Azimian F, Klosa K and Kern M. Evaluation of a new universal primer for ceramics and alloys. J Adhes Dent 2011; 13: 561–7. 29. Koizumi H, Nakayama D, Komine F, Blatz MB and Matsumura H. Bonding of resin-based luting cements to Zirconia with and without the use of ceramic priming agents. J Adhes Dent 2012; 14(4): 385 -92. 30. Cavalcanti AN, Foxton RM, Watson TF, Oliveira MT, Giannini M, Marchi GM. Bond strength of resin cements to a zirconia ceramic with different surface treatments. Operative Dentistry 2009; 34(3): 280–7. 31. ErsuB, Yuzugullu B, RuyaYazici A and Canay S. Surface roughness and bond strengths of glass- iniltrated alumina-ceramics prepared using various surface treatments. J Dentistry 2009; 37(11): 848–56. 32. Aboushelib MN, Feilzer AJ, Kleverlaan CJ. Bonding to zirconia using a new surface treatment. J Prosthodontics 2010; 19(5): 340–6. 33. de Oyague RC, Monticelli F, Toledano M, Osorio E, Ferrari M and Osorio R. Influence of surface treatments and resin Oxide ceramic. Dental Materials 2009; 25(2): 172–9. 34. Yang B, Barloi A, Kern M. Influence of air-abrasion on zirconia ceramic bonding using an adhesive composite resin. Dent Mater J 2010; 26(1):44–50.