This is an open access article under the terms of a license that permits non-commercial use, provided the original work is properly cited. © 2021 The Authors. Société Internationale d'Urologie Journal, published by the Société Internationale d'Urologie, Canada. The Right Instrument for the Right Purpose: Spreading the Use of Small Caliber Ureteroscope for the Inspection of the Male and Female Urethra Sanjay B. Kulkarni,1 Marco Bandini,1,2,3 Amey Patil,1 Shreyas Bhadranavar,1 Vipin Sharma,1 Sandeep Bafna,1 Shreeranga L. Yatam,1 Guido Barbagli,3 Francesco Montorsi,2 Pankaj M. Joshi1 1Kulkarni Reconstructive Urology Center, Pune, India 2Unit of Urology, Urological Research Institute (URI), San Raffaele Hospital, Vita-Salute San Raffaele University, Milan, Italy 3Center for Reconstructive Urethral Surgery, Arezzo, Rome, Milan, Italy Abstract The inspection of the urethra in patients with documented or suspected urethral stricture should be carried out with small caliber ureteroscope of 6/7.5Ch. Different from flexible cystoscope (16Ch) or resectoscope (26Ch), small caliber ureteroscope allows a comprehensive evaluation of the stricture, including its length and the status of the mucosa in its proximity, without injuring or overstretching the urethra. With a small caliber ureteroscope it is also possible to cross the stricture, allowing the evaluation of the proximal urethra, the external urethral sphincter, and the bladder. A 6/7.5Ch ureteroscope also allows estimation of the real caliber of the stricture, providing a useful landmark for further treatment decisions. As members of the reconstructive urology community and experts in the field of urethroplasty, it is our duty not only to discover new surgical techniques[1] but also to provide advice that can change our daily practice to the advantage of our patients. In this regard, we are honored to share our view of the correct management of patients with urethral stricture. We believe the assessment of patients with urethral stricture starts with the appropriate and judicious evaluation of the urethra. In a patient complaining of poor flow, when the urethrogram shows a narrowing along the urethra, the choice of the right endoscopic instrument for inspection is pivotal. Based on our long experience of urethroplasty and urethral disease management, we recommend the use of a small caliber ureteroscope to inspect the urethra. Specifically, a 6/7.5Ch ureteroscope; the first digit refers to the size of the ureteroscope at the tip and the second to the size of the instrument at the base. The normal caliber of the bulbar urethra is 30Ch[2], which means that the diameter is around 1cm. A resectoscope, which is commonly adopted for transurethral resection of the prostate, is 26Ch, and f lexible cystoscopes are approximately 16Ch. According to Smith et al.[3], urethral strictures become symptomatic (ie, require dilatation and antibiotic treatment) when the urine flow is below 7mL/min, which corresponds approximately to a urethral caliber below 16Ch. In other words, when patients come for initial evaluation, the urethral lumen, at the level of the stricture, typically does not allow “common” instruments to go across the stricture (Figure 1). This is an open access article under the terms of a license that permits non-commercial use, provided the original work is properly cited. © 2021 The Authors. Société Internationale d'Urologie Journal, published by the Société Internationale d'Urologie, Canada. Key Words Competing Interests Article Information Small caliber instrument, education, urethra; ureteroscope, reconstructive urology None declared. Received on April 21, 2021 Accepted on May 19, 2021 Soc Int Urol J.2021;2(4):259–263 DOI: 10.48083/NVKO4969 SIUJ.ORG SIUJ • Volume 2, Number 4 • July 2021 259 BRIEF COMMUNICATION mailto:bandini.marco%40hsr.it?subject=SIUJ http://www.siuj.org Kulkarni’s �ow-chart for bulbar urethral stricture 1) Post-TURP 2) Obese patients 3) Young sexually active male Redo-case with stricture >7ch Circumferantial mobilization and Barbagli dorsal or ventral onlay In complex cases In straightforward cases Stricture > 3Ch Kulkarni one-side dissection with dorsal onlay BMG Asopa Ventral Onlay Urethral stricture length <5mm: • mucosa-to-mucosa anastomosis with/without opposite side BMG augmentation Urethral stricture length 5 -15mm: • double face augmented BMG urethroplasty • augmented non-transecting anastomotic urethroplasty Augmented anastomotic urethroplasty Urethral stricture length >15mm 2-stages Graft + Flap If failure Non-traumaticObliterated stricture (<3Ch) Anastomotic urethroplastyPost-traumatic Different sizes of bulbar urethra 30Ch 26Ch 16Ch 7Ch 3Ch Guidewire Resectoscope Flexible cystoscope Small caliber ureteroscope (6/7.5Ch) 0Ch FIGURE 1. The choice of the correct instrument according to the different sizes of urethra. Kulkarni’s flow chart for urethroplasty techniques according to stricture characteristics 2 SIUJ • Volume 2, Number 4 • July 2021 SIUJ.ORG BRIEF COMMUNICATION http://www.siuj.org The 6/7.5Ch ureteroscope was introduced into urological practice more than 10 years ago. Since then, it has been employed mainly for stone management[4] and/or pediatric urolog y[5], and its use has not been popularized among reconstructive urologists. Nonetheless, we believe that small caliber ureteroscope should become the gold standard for the inspection of the urethra in patients referred for stricture management. First and foremost, it decreases the risk of injuring the urethra. Indeed, the 6/7.5Ch ureteroscope allows the surgeon to navigate the urethra away from the urethral walls, preventing accidental injury of the mucosa. It also avoids trauma to the surrounding spongy tissue, preventing over-distension and stretching. Second, a sma ll ca liber ureteroscope may a llow close-up visualization of the stricture and may enable visualization across the length of the stricture. This second aspect is very important, especially for planning the subsequent t reat ment. Indeed, ret rog rade a nd a nterog rade urethrograms may underestimate the real complexity of the stricture (Video 1). In particular, retrograde and anterograde urethrograms may not always give a realistic representation of either the extension or the severity of the urethral stricture. Moreover, urethrograms do not provide information on the status of the mucosa across and in proximity to the stricture (Figure 2). Assessing the real length of the stricture and the status of the surrounding mucosa is pivotal in patients with lichen sclerosus or any non-traumatic etiologies, which may involve longer segments of the urethra. Surgical decision- making may change considerably depending on the length of the stricture or the aspect of the forthcoming urethral mucosa. For instance, the choice of end-to-end anastomosis, augmented urethroplasty, or stricturoplasty can be made only with knowledge of the extension of the stricture and the status of the urethra before and after the stricture. This vital information can be acquired only with a full inspection of the urethral lumen. In our experience, the estimation of stricture length is more accurate when it is carried out with the endoscopic view rather than urethrograms. Indeed, the endoscopic findings more frequently match with the surgical view. Only with the use of these small caliber instruments does the surgeon have the advantage of a comprehensive evaluation of the urethra for planning the correct treatment. Third, only small ureteroscope may give access to false passage or fistulae encountered during the inspection of the urethra with minimal risk of extravasation or perforation. The latter is extremely important in patients referred for redo surgery, pelvic fracture urethral injury, or stricture related to infection with concomitant abscess. Fourth, with a small caliber ureteroscope it is possible to cross the stricture reaching the proximal urethra and the bladder. This opportunity is of paramount importance, especially VIDEO 1. Patient with distal anastomotic stenosis after dorsal onlay BMG urethroplasty. The 6/7.5Ch ureteroscope was able to cross the stricture and to allow the inspection of the proximal urethra 3SIUJ.ORG SIUJ • Volume 2, Number 4 • July 2021 The Right Instrument for the Right Purpose: Spreading the Use of Small Caliber Ureteroscope http://www.siuj.org to rule out the presence of stones or neoplasms, which can radically change the management of the patient. The use of small caliber ureteroscope is particularly advantageous in female patients. To rule out the presence of stricture in women, the inspection of the urethra must be carried out with great care and attention because the female urethra is short, poorly distensible, and has great mobility. Larger caliber instruments are inappropriate for this task because they do not allow a comprehensive evaluation of the length and severity of the stricture. Indeed, larger caliber instrument may be unable to enter the meatus when fibrotic or, when the stricture is more proximal, they may overstretch the urethra, hiding the presence of the stenosis and its extension. Last but not least, small caliber instruments provide a useful calibration of the urethral lumen to determine the most appropriate urethroplasty technique. According to our personal flow chart (Figure. 1), a stricture which allows only a 6/7.5Ch ureteroscope can be approached with augmented urethroplasty following the Barbagli[6] or Kulkarni[7] principles. Conversely, an obliterated or semi-obliterated stricture (<3 Ch) can be repaired with anastomotic urethroplasty when secondary to trauma, or with non-transecting approaches (including double face[8], mucosa-to-mucosa[9], augmented non- transecting anastomotic urethroplasty[10]), graft plus flap or two-stage urethroplasty when secondary to non- traumatic etiologies. Finally, we acknowledge that the use of small caliber ureteroscope can be challenging at the beginning because of the difficulties of handling and maneuvering this long and thin instrument, as well as the suboptimal view. However, we believe that the great benefit derived from its use justifies the effort needed for the learning curve. In summary, we suggest that all reconstructive urologists dealing with urethroplasty consider discontinuing the use of flexible or rigid cystoscopes with caliber above 16Ch. Instead, we recommend they embrace a small caliber ureteroscope (6/7.5Ch) for the evaluation of the urethra in patients, male or female, with a confirmed or suspected diagnosis of urethral stricture, before surgery. FIGURE 2. Examples of retrograde urethrograms where length and characteristics of the strictures cannot be assessed without endoscopic inspection 4 SIUJ • Volume 2, Number 4 • July 2021 SIUJ.ORG BRIEF COMMUNICATION http://www.siuj.org References 1. Barbagli G, Bandini M, Balò S, Sansalone S, Butnaru D, Lazzeri M. Surgical treatment of bulbar urethral strictures: tips and tricks. Int Braz J Urol.2020;46:511– 8. https://doi.org/10.1590/S1677-5538. IBJU.2020.99.04. 2. Brandes SB, Morey AF, eds. Advanced male urethral and genital reconstructive surgery.2004; SpringerLink. Available at: https:// link.springer.com/book/10.1007%2F978-1-4614-7708-2. Accessed April 15, 2021. 3. Smith JC. The measurement and significance of the urinary flow rate. Br J Urol.1966;38:701– 6. ht tps://doi.org/10.1111/j.14 6 4 - 410x.1966.tb09783.x. 4. Francesca F, Scattoni V, Nava L, Pompa P, Grasso M, Rigatti P. Failures and complications of transurethral ureteroscopy in 297 cases: conventional rigid instruments vs. small caliber semirigid ureteroscopes. Eur Urol.1995;28:112– 5. ht tps://doi. org/10.1159/000475032. 5. Zhu J, Phillips T M, Mathews RI. Operative management of pediatric urolithiasis. Indian J Urol.2010;26:536 – 43. https://doi. org/10.4103/0970-1591.74454. 6. Barbagli G, Montorsi F, Guaz zoni G, L archer A , F ossati N, Sansalone S, et al. Ventral oral mucosal onlay graft urethroplasty in nontraumatic bulbar urethral strictures: surgical technique and multivariable analysis of result s in 214 p atient s. Eur Urol.2013;64:440–7. https://doi.org/10.1016/j.eururo.2013.05.046. 7. Kulkarni S, Barbagli G, Sansalone S, Lazzeri M. One-sided anterior urethroplasty: a new dorsal onlay graft technique. BJU Int.2009; 104:1150–5. https://doi.org/10.1111/j.1464-410X.2009.08590.x. 8. Palminteri E, Manzoni G, Berdondini E, Di Fiore F, Testa G, Poluzzi M, et al. Combined dorsal plus ventral double buccal mucosa graft in bulbar urethral reconstruction. Eur Urol.2008;53:81–9. https:// doi.org/10.1016/j.eururo.2007.05.033. 9. Andrich DE, Mundy AR. Non-transecting anastomotic bulbar urethroplast y: a preliminar y repor t. BJU Int.2012;109:1090 – 4. https://doi.org/10.1111/j.1464-410X.2011.10508.x. 10. Welk BK, Kodama RT. The augmented nontransected anastomotic urethroplast y for the treatment of bulbar urethral strictures. Urology.2012;79:917–21. https://doi.org/10.1016/j.urology.2011.12.008. 5SIUJ.ORG SIUJ • Volume 2, Number 4 • July 2021 The Right Instrument for the Right Purpose: Spreading the Use of Small Caliber Ureteroscope https://link.springer.com/book/10.1007%2F978-1-4614-7708-2 https://link.springer.com/book/10.1007%2F978-1-4614-7708-2 https://link.springer.com/book/10.1007%2F978-1-4614-7708-2 https://link.springer.com/book/10.1007%2F978-1-4614-7708-2 https://doi.org/10.1111/j.1464-410x.1966.tb09783. https://doi.org/10.1111/j.1464-410x.1966.tb09783. https://doi.org/10.1159/000475032 https://doi.org/10.1159/000475032 https://doi.org/10.4103/0970-1591.74454 https://doi.org/10.4103/0970-1591.74454 https://doi.org/10.1016/j.eururo.2013.05.046 https://doi.org/10.1111/j.1464-410X.2009.08590.x https://doi.org/10.1016/j.eururo.2007.05.033 https://doi.org/10.1016/j.eururo.2007.05.033 https://doi.org/10.1111/j.1464-410X.2011.10508.x https://doi.org/10.1016/j.urology.2011.12.008 http://www.siuj.org